Search NASA⌕ Search

SEARCH · Search NASA

Results for “Aberrated probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Aberrated electron probes for magnetic spectroscopy with atomic resolution: Theory and practical aspects

It was recently proposed that electron magnetic circular dichroism (EMCD) can be measured in scanning transmission electron microscopy (STEM) with atomic resolution by tuning the phase distribution of a electron beam. Here, we describe the theoretical and practical aspects for the detection of out-of-plane and in-plane magnetization utilizing atomic size electron probes. Here we present the calculated optimized astigmatic probes and discuss how to achieve them experimentally.

47 OTHER INSTRUMENTATION↗

Electron ptychography achieves atomic-resolution limits set by lattice vibrations

Transmission electron microscopes use electrons with wavelengths of a few picometers, potentially capable of imaging individual atoms in solids at a resolution ultimately set by the intrinsic size of an atom. However, owing to lens aberrations and multiple scattering of electrons in the sample, the image resolution is reduced by a factor of 3 to 10. By inversely solving the multiple scattering problem and overcoming the electron-probe aberrations using electron ptychography, we demonstrate an instrumental blurring of less than 20 picometers and a linear phase response in thick samples. The measured widths of atomic columns are limited by thermal fluctuations of the atoms. As a result, our method is also capable of locating embedded atomic dopant atoms in all three dimensions with subnanometer precision from only a single projection measurement.

42 ENGINEERING↗

Probing interfacial electronic structures in atomic layer LaMnO{sub3} and SrTiO{sub 3} superlattices.

The interfacial electronic structure characterization of a m x (LaMnO{sub 3})/n x (SrTiO{sub 3}) superlattice based on scanning transmission electron microscopy and electron energy loss spectroscopy. Evidence of interfacial band alignment and electron transfer are presented based on the observation of O K edge of individual transition metal and oxygen atomic columns. Electron probe aberration correction was essential for the high spatial resolution mapping of interfacial electronic states.

36 MATERIALS SCIENCE↗

Electron-beam-induced-current and active secondary-electron voltage-contrast with aberration-corrected electron probes

The ability to map out electrostatic potentials in materials is critical for the development and the design of nanoscale electronic and spintronic devices in modern industry. Electron holography has been an important tool for revealing electric and magnetic field distributions in microelectronics and magnetic-based memory devices, however, its utility is hindered by several practical constraints, such as charging artifacts and limitations in sensitivity and in field of view. In this article, we report electron-beam-induced-current (EBIC) and secondary-electron voltage-contrast (SE-VC) with an aberration-corrected electron probe in a transmission electron microscope (TEM), as complementary techniques to electron holography, to measure electric fields and surface potentials, respectively. These two techniques were applied to ferroelectric thin films, multiferroic nanowires, and single crystals. Electrostatic potential maps obtained by off-axis electron holography were compared with EBIC and SE-VC to show that these techniques can be used as a complementary approach to validate quantitative results obtained from electron holography analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detecting magnetic ordering with atomic size electron probes

While magnetism originates at the atomic scale, the existing spectroscopic techniques sensitive to magnetic signals only produce spectra with spatial resolution on a larger scale. However, recently, it has been theoretically argued that atomic size electron probes with customized phase distributions can detect magnetic circular dichroism. Here, we report a direct experimental real-space detection of magnetic circular dichroism in aberration-corrected scanning transmission electron microscopy (STEM). Using an atomic size-aberrated electron probe with a customized phase distribution, we reveal the checkerboard antiferromagnetic ordering of Mn moments in LaMnAsO by observing a dichroic signal in the Mn L-edge. The novel experimental setup presented here, which can easily be implemented in aberration-corrected STEM, opens new paths for probing dichroic signals in materials with unprecedented spatial resolution.

36 MATERIALS SCIENCE↗

Atomic-Resolution Imaging with a Sub-50-pm Electron Probe

Using a highly coherent focused electron probe in a fifth-order aberration-corrected transmission electron microscope, we report on resolving a crystal spacing less than 50 pm. Based on the geometrical source size and residual coherent and incoherent axial lens aberrations, an electron probe is calculated, which is theoretically capable of resolving an ideal 47 pm spacing with 29% contrast. Our experimental data show the 47 pm spacing of a Ge <114> crystal imaged with 11%-18% contrast at a 60%-95% confidence level, providing the first direct evidence for sub-50-pm resolution in annular dark-field scanning transmission electron microscopy imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Induction of chromosome aberrations in human cells by charged particles

Chromosome aberrations induced by high-energy charged particles in normal human lymphocytes and human fibroblasts have been investigated. The charged particles included 250 MeV/nucleon protons, 290 MeV/nucleon carbon ions and 1 GeV/nucleon iron ions. The energies of the charged particles were higher than in most of the studies reported in the literature. Lymphocytes were stimulated to grow immediately after irradiation, while fibroblasts were incubated at 37 degrees C for 24 h for repair. Chromosomes were collected at the first mitosis after irradiation and chromosome aberrations were scored using the fluorescence in situ hybridization (FISH) technique with a whole-chromosome 4 probe. Chromosome aberrations were classified as reciprocal exchanges, incomplete exchanges, deletions and complex exchanges. The relative biological effectiveness (RBE) for each type of aberration was calculated by dividing a dose of 4 Gy by the dose of the charged particles producing the same effect as 4 Gy of gamma rays. Results of this study showed that complex aberrations have the highest RBE for radiation of high linear energy transfer (LET) for human lymphocytes, but for fibroblasts, the greatest effect was for incomplete exchanges. For both lymphocytes and fibroblasts, iron ions induced a similar fraction of aberrant cells.

NASA Center JSC↗

Calculation of integrated intensities in aberration-corrected Z-contrast images

Inclusion of spatial incoherence has been shown to give quantitative agreement between non-aberration-corrected high-angle annular dark-field scanning transmission electron microscopy images and theoretical simulations. Here we show that, using the same approach, a significant improvement in the correlation between calculated and experimental normalized integrated intensities is obtained in the InAsP ternary semiconductor alloy, but residual discrepancies remain. We have demonstrated, in good agreement with experimental intensities obtained in calibrated samples, that normalized integrated intensities show a low dependence on the sample thickness over a wide range of thickness values. This behaviour does not occur in conventional (non-aberration-corrected) images and constitutes a powerful tool for straightforward interpretation of high-resolution images in terms of atomic column-resolved compositional maps.

36 MATERIALS SCIENCE↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

Relaxing Direct Ptychography Sampling Requirements via Parallax Imaging Insights

Direct ptychography enables the retrieval of information encoded in the phase of an electron wave passing through a thin sample by deconvolving the interference effects of a converged probe with known aberrations. Under the weak phase object approximation, this permits the optimal transfer of information using noniterative techniques. However, the achievable resolution of the technique is traditionally limited by the probe step size—setting stringent Nyquist sampling requirements. At the same time, parallax imaging has emerged as a dose-efficient phase technique which relaxes sampling requirements and enables scan-upsampling. Here, we formulate parallax imaging as a quadratic approximation to part of the direct ptychography kernel and use this insight to enable upsampling in direct ptychography. We validate our analytical results numerically using simulated and experimental reconstructions.

direct ptychography, parallax imaging, scan Nyquis↗

Presence and spatial distribution of interfacial electronic states in LaMnO{sub 3}-SrMnO{sub 3} superlattices.

We report direct evidence of interfacial states at the onset of O K edge confined to a spatial distance of 1 unit-cell full-width at half maximum at the sharp interfaces between epitaxial films of LaMnO{sub 3} and SrMnO{sub 3} from electron energy-loss spectroscopy (EELS) measurements. The interfacial states are sensitive to interface sharpness; at rough interfaces with interfacial steps of 1-2 unit cells in height, experimental data shows a reduction, or suppression, of the interfacial states. The EELS measurements were performed using a fine electron probe obtained by electron lens aberration correction. By scanning the electron probe across the interface, we are able to map the spatial distribution of the interfacial states across interfaces at high resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Performance DNA Probes for Perinatal Detection of Numerical Chromosome Aberrations

Human reproduction is a tightly controlled process of stepwise evolution with multiple, mostly yet unknown milestones and checkpoints. Healthy halpoid gametes have to be produced by the parents, which will fuse to form the diploid zygote that implants in the female uterus and grows to become first an embryo, then a fetus and finally matures into a newborn. There are several known risk factors that interfere with normal production of gametes, spermatocytes or oocytes, and often cause embryonic mortality and fetal demise at an early stage. Yet some embryos with chomosomal abnormalities can develop beyond the critical first trimester of pregnancy and, while those with supernumary chromosomes in their hyperdiploid cells will be spontaneously aborted, a small fraction of fetuses with an extra chromosome continues to grow to term and will be delivered as a liveborn baby. While minor clinical symptoms displayed by children with trisomies are manageable for many parents, the burden of caring for a child with numerical chromosome abnormalities can be overwhelming to partners or individual families. It also poses a significant financial burden to the society and poses ethical dilemma. In this communication, we will review the progress that has been made in the development of molecular techniques to test individual fetal cells for chromosomal imbalances. We will focus our discussion on the direct visualization of chromosome-specific DNA sequences in live or fixed specimens using fluorescence in situ hybridization (FISH) and, more specifically, talk about the groundbreaking progress that in recent years has been achieved towards an improved diagnosis with novel, chromosome-specific DNA probes.

Fluorescence in situ hybridization (FISH)↗

Evolutionary determination of experimental parameters for ptychographical imaging

The Ptychographical Iterative Engine (PIE) algorithm is a recently developed novel method of Coherent Diffractive Imaging (CDI) that uses multiple overlapping diffraction patterns to reconstruct an image. This method has successfully produced high quality reconstructions at both optical and X-ray wavelengths but the need for accurate knowledge of the probe positions is currently a limiting factor in the production of high resolution reconstructions at electron wavelengths. This paper examines the shape of the search landscape for producing optimal image reconstructions in the specific case of electron microscopy and then shows how evolutionary search methods can be used to reliably determine experimental parameters in the electron microscopy case (such as the spherical aberration in the probe and the probe positions).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The importance of temporal and spatial incoherence in quantitative interpretation of 4D-STEM

Recent developments in pixelated detectors, when combined with aberration correction of probe forming optics have greatly enhanced the field of scanning electron diffraction. Differential phase contrast is now routine and deep learning has been proposed as a method to extract maximum information from diffraction patterns. This study examines the effects of temporal and spatial incoherence on convergent beam electron diffraction patterns and demonstrates that simple center of mass measurements cannot be naively interpreted. The inclusion of incoherence in deep learning data sets is also discussed.

36 MATERIALS SCIENCE↗