Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absorptiometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Material Identification Using Dual Energy X-ray Absorptiometry

Two implementations of dual energy X-ray absorptiometry were studied to identify materials using X-ray attenuation data taken with the Digital Radiography and Computed Tomography (DRCT) systems that were developed for the Recovered Chemical Materiel Directorate (RCMD). Maitrejean et al.’s approach utilizes eigen effects through Principal Component Analysis, while Osipov et al.’s approach proposed a physics-based method. Both approaches approximate mass attenuation coefficients of materials as a linear combination of basis functions (eigen effects) or physics-based equations. A set of coefficients {a 1 , a 2 , a 3 } or {B, D} were found by parameter optimization in EXCEL Solver. The identification parameters, {$\frac{a_{2}}{a_{1}}$, $\frac{a_{3}}{a_{1}}$} or estimated effective atomic number $\hat{Z}$ from {B, D}, were calculated to identify material of an aluminum 8 step wedge and a steel 8 step wedge in X-ray radiography images taken by a DRCT system. Maitrejean et al.’s approach was unable to provide reliable $\frac{a_{3}}{a_{1}}$ ratio values for identification of materials. Osipov et al.’s approach was found to be more robust in identify materials with a semi-empirical formula derived from test results in this study.

36 MATERIALS SCIENCE↗

Body surface area equations for physically active men and women

Abstract Objectives To improve predictive formulae for estimating body surface area (BSA) in healthy men and women using a modern three‐dimensional scanner technology. Methods Body surface areas were obtained from a convenience sample of 1267 US Marines (464 women and 803 men) using a whole body surface scanner (Size Stream SS20). The reliability of SS20 measures of total and regional BSA within participants was compared across triplicate scans. We then derived a series of formulae to estimate SS20‐measured BSA using various combinations of sex, height, and mass. We also assessed relationships between percent body fat measured by dual‐energy x‐ray absorptiometry and sex‐specific formulae errors in Marines. Results Body surface areas recorded by the SS20 were highly reliable whether measured for the total body or by region (ICC ≥ .962). Formulae estimates of BSA from sex, height, and mass were precise (root‐mean‐square deviation, 0.031 m 2 ). Errors from the Marine Corps formulae were positively associated with percent body fat for men ( p = .001) but not women ( p = .843). Conclusions Clinicians, military leaders, and researchers can use the newly developed BSA formulae for precise estimates in healthy physically active men and women. Users should be aware that height‐ and mass‐based BSA estimates are less accurate for individuals with extremely low or high percent body fat.

Looney, David P.↗

Development and cross‐validation of a circumference‐based predictive equation to estimate body fat in an active population

Abstract Objective The U.S. Army uses sex‐specific circumference‐based prediction equations to estimate percent body fat (%BF) to evaluate adherence to body composition standards. The equations are periodically evaluated to ensure that they continue to accurately assess %BF in a diverse population. The objective of this study was to develop and validate alternative field expedient equations that may improve upon the current Army Regulation (AR) body fat (%BF) equations. Methods Body size and composition were evaluated in a representatively sampled cohort of 1904 active‐duty Soldiers (1261 Males, 643 Females), using dual‐energy X‐ray absorptiometry (%BF DXA ), and circumferences obtained with 3D imaging and manual measurements. Sex stratified linear prediction equations for %BF were constructed using internal cross validation with %BF DXA as the criterion measure. Prediction equations were evaluated for accuracy and precision using root mean squared error, bias, and intraclass correlations. Equations were externally validated in a convenient sample of 1073 Soldiers. Results Three new equations were developed using one to three circumference sites. The predictive values of waist, abdomen, hip circumference, weight and height were evaluated. Changing from a 3‐site model to a 1‐site model had minimal impact on measurements of model accuracy and performance. Male‐specific equations demonstrated larger gains in accuracy, whereas female‐specific equations resulted in minor improvements in accuracy compared to existing AR equations. Equations performed similarly in the second external validation cohort. Conclusions The equations developed improved upon the current AR equation while demonstrating robust and consistent results within an external population. The 1‐site waist circumference‐based equation utilized the abdominal measurement, which aligns with associated obesity related health outcomes. This could be used to identify individuals at risk for negative health outcomes for earlier intervention.

Taylor, Kathryn M.↗

Criterion validity of wrist accelerometry for assessing energy intake via the intake-balance technique

Background: Intake-balance assessments measure energy intake (EI) by summing energy expenditure (EE) with concurrent change in energy storage (ΔES). Prior work has not examined the validity of such calculations when EE is estimated via open-source techniques for research-grade accelerometry devices. The purpose of this study was to test the criterion validity of accelerometry-based intake-balance methods for a wrist-worn ActiGraph device. Methods: Healthy adults (n = 24) completed two 14-day measurement periods while wearing an ActiGraph accelerometer on the non-dominant wrist. During each period, criterion values of EI were determined based on ΔES measured by dual X-ray absorptiometry and EE measured by doubly labeled water. A total of 11 prediction methods were tested, 8 derived from the accelerometer and 3 from non-accelerometry methods (e.g., diet recall; included for comparison). Group-level validity was assessed through mean bias, while individual-level validity was assessed through mean absolute error, mean absolute percentage error, and Bland–Altman analysis. Results: Mean bias for the three best accelerometry-based methods ranged from -167 to 124 kcal/day, versus -104 to 134 kcal/day for the non-accelerometry-based methods. The same three accelerometry-based methods had mean absolute error of 323–362 kcal/day and mean absolute percentage error of 18.1-19.3%, versus 353–464 kcal/day and 19.5-24.4% for the non-accelerometry-based methods. All 11 methods demonstrated systematic bias in the Bland–Altman analysis. Conclusions: Accelerometry-based intake-balance methods have promise for advancing EI assessment, but ongoing refinement is necessary. We provide an R package to facilitate implementation and refinement of accelerometry-based methods in future research (see paulhibbing.com/IntakeBalance).

60 APPLIED LIFE SCIENCES↗

Male Runners With Lower Energy Availability Have Impaired Skeletal Integrity Compared to Nonathletes

Abstract Context Female athletes, particularly runners, with insufficient caloric intake for their energy expenditure [low energy availability (EA) or relative energy deficiency] are at risk for impaired skeletal integrity. Data are lacking in male runners. Objective To determine whether male runners at risk for energy deficit have impaired bone mineral density (BMD), microarchitecture, and estimated strength. Design Cross-sectional. Setting Clinical research center. Participants 39 men (20 runners, 19 controls), ages 16–30 years. Main Outcome Measures Areal BMD (dual-energy x-ray absorptiometry); tibia and radius volumetric BMD and microarchitecture (high-resolution peripheral quantitative computed tomography); failure load (microfinite element analysis); serum testosterone, estradiol, leptin; energy availability. Results Mean age (24.5 ± 3.8 y), lean mass, testosterone, and estradiol levels were similar; body mass index, percent fat mass, leptin, and lumbar spine BMD Z-score (−1.4 ± 0.8 vs −0.8 ± 0.8) lower (P < .05); and calcium intake and running mileage higher (P ≤ .01) in runners vs controls. Runners with EA <median had lower lumbar spine (−1.5 ± 0.7, P = .028), while runners with EA ≥median had higher hip (0.3 ± 0.7 vs −0.4 ± 0.5, P = .002), BMD Z-scores vs controls. After adjusting for calcium intake and running mileage, runners with EA <median had lower mean tibial total and trabecular volumetric BMD, trabecular bone volume fraction, cortical porosity, and apparent modulus vs controls (P < .05). Appendicular lean mass and serum estradiol (R ≥ 0.45, P ≤ .046), but not testosterone, were positively associated with tibial failure load among runners. Conclusions Despite weight-bearing activity, skeletal integrity is impaired in male runners with lower caloric intake relative to exercise energy expenditure, which may increase bone stress injury risk. Lower estradiol and lean mass are associated with lower tibial strength in runners.

Haines, Melanie S. (ORCID:0000000310024754)↗

Artificial Intelligence for Accelerating Nuclear Applications, Science, and Technology

Artificial intelligence (AI) and machine learning (ML) methods have had significant impacts in science and technology in recent years. These methods for generating models from datasets or logic-based algorithms that emulate aspects of human performance can similarly accelerate the fields of nuclear applications, science, and technology toward the IAEA goals of contributing to peace, health, and prosperity. In order to accomplish advances with AI in general and ML in particular across these fields, IAEA can play a significant role by establishing, hosting and curating centralised resources, including databases, adhering to FAIR (findable, accessible, interoperable and reusable) principles and Open Science best practices, providing stewardship of data sharing, supporting training efforts and development of relevant workforces, as well as enabling connections among the scientific, technology, mathematics, AI and ethics communities. Many areas can benefit from the use of AI in the realm of nuclear applications. In human health, these areas include clinical research, epidemiology, nutrition, medical imaging, radiotherapy and education of health professionals. AI-based tools are also being used to facilitate different clinical tasks in imaging, computer-assisted diagnosis in mammography and lung cancer screening programmes, and dose prediction in nuclear medicine procedures. ML methods in particular may also increase the efficiency and accuracy of the analysis of computerised tomography and dual-energy absorptiometry scans for body composition and bone analysis. The application of AI methods to nuclear and related technologies in food and agriculture can lead to significant advances and improved efficiency in the optimisation of agricultural production, food product development, management of supply chains, food safety and food authenticity control. In the water and environmental sector, AI can help inform policies to mitigate the world’s water problems. The application of AI techniques to hydrology and environmental sciences is expected to improve patterns identification and enable model predictions under a changing climate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

The 300 Marines: characterizing the US Marines with perfect scores on their physical and combat fitness tests

Few US Marines earn perfect 300 scores on both their Physical Fitness Test (PFT) and Combat Fitness Test (CFT). The number 300 invokes the legendary 300 Spartans that fought at the Battle of Thermopylae, which inspired high physical fitness capabilities for elite ground forces ever since. Purpose: Determine distinguishing characteristics of the “300 Marines” (perfect PFT and CFT scores) that may provide insights into the physical and physiological requirements associated with this capability. These tests have been refined over time to reflect physical capabilities associated with Marine Corps basic rifleman performance. Materials and methods: Data were analyzed from US Marines, including 497 women (age, 29 ± 7 years; height 1.63 ± 0.07 m; body mass, 67.4 ± 8.4 kg) and 1,224 men (30 ± 8 years; 1.77 ± 0.07 m; 86.1 ± 11.1 kg). Marines were grouped by whether they earned perfect 300 scores on both the PFT and CFT (300 Marines) or not. We analyzed group differences in individual fitness test events and body composition (dual-energy x-ray absorptiometry). Results: Only 2.5% (n = 43) of this sample earned perfect PFT and CFT scores (n = 21 women; n = 22 men). Compared to sex-matched peers, 300 Marines performed more pull-ups, with faster three-mile run, maneuver-under-fire, and movement-to-contact times (each p < 0.001); 300 Marines of both sexes had lower fat mass, body mass index, and percent body fat (each p < 0.001). The lower percent body fat was explained by greater lean mass (p = 0.041) but similar body mass (p = 0.085) in women, whereas men had similar lean mass (p = 0.618), but lower total body mass (p = 0.025). Conclusion: Marines earning perfect PFT and CFT scores are most distinguished from their peers by their maneuverability, suggesting speed and agility capabilities. While both sexes had considerably lower percent body fat than their peers, 300 Marine women were relatively more muscular while men were lighter.

60 APPLIED LIFE SCIENCES↗