Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Generation and propagation of an electromagnetic pulse in the Trigger experiment and its possible role in electron acceleration

Instruments onboard the Trigger payload detected a large-amplitude, low-frequency, electric field pulse which was observed with a time delay consistent only with an electromagnetic wave. A model for this perturbation is constructed, and the associated field-aligned current is calculated as a function of altitude. This experiment may simulate the acceleration mechanism which results in the formation of auroral arcs, and possibly even other events in cosmic plasmas.

Kelley, M. C.↗

Design of a Low-Cost, Submersible, Digital Holographic Microscope for in Situ Microbial Imaging

The methodologies for studying marine microbiology typically consist of utilizing instrumentation within a laboratory. This typically requires extracting a sample from its place of origin prior to examination, which may be days after collection. Oftentimes, the solution is to bring the lab to the ocean, which may be costly and provide further limitations for a sterile and stable laboratory environment. Here we present a low-cost, submersible, digital holographic microscope (DHM) designed to image marine microorganisms (such as bacteria and plankton) in their natural underwater environment. Our instrument eliminates the need to transport samples and allows for instantaneous data collection of microbes in-situ. The DHM achieves sub-micron spatial resolution and is paired with artificial intelligence for the detection and tracking of specimens to reduce the overall collected data. This instrument also aims to reduce the cost of manufacturing and field expenses relative to marine microbiological research. “Off the shelf” components were selected in the design process of this instrument which allows us to achieve precise results without sacrificing data quality. The DHM itself costs under one thousand dollars and features a low-cost high-resolution camera, the Arducam MT9J001. Included in the design were five main subsystems: optical, mechanical, electrical, power, and machine learning. Our on board computer and artificial intelligence consist of a Raspberry Pi 4 (8 Gb) and Google Coral USB Tensorflow accelerator. Instrument testing has successfully proven our abilities of data acquisition for at least two hours in depths of at least forty meters below sea level. Additionally, our artificial intelligence system is currently capable of tracking up to ten areas of interest in a fraction of a second with over ninety percent confidence via the neural net driven by the tensor cores on the Google Coral. Furthermore, we have demonstrated the versatility of our instrument by mounting it on an ocean-going ROV, the BlueRov2 by BlueRobotics. Our tests on the BlueRov2 exemplified the cost-effective nature of a submersible and reusable instrument that can be implemented in moderate environments and on most vessels.

Wallace, James Kent↗

Physics through the 1990s: Elementary-particle physics

The volume begins with a non-mathematical discussion of the motivation behind, and basic ideas of, elementary-particle physics theory and experiment. The progress over the past two decades with the quark model and unification of the electromagnetic and weak interactions is reviewed. Existing theoretical problems in the field, such as the origin of mass and the unification of the fundamental forces, are detailed, along with experimental programs to test the new theories. Accelerators, instrumentation, and detectors are described for both current and future facilities. Interactions with other areas of both theoretical and applied physics are presented. The sociology of the field is examined regarding the education of graduate students, the organization necessary in large-scale experiments, and the decision-making process involved in high-cost experiments. Finally, conclusions and recommendations for maintaining US excellence in theory and experiment are given. Appendices list both current and planned accelerators, and present statistical data on the US elementary-particle physics program. A glossary is included.

Source record↗

Physics through the 1990s: Nuclear physics

The volume begins with a non-mathematical introduction to nuclear physics. A description of the major advances in the field follows, with chapters on nuclear structure and dynamics, fundamental forces in the nucleus, and nuclei under extreme conditions of temperature, density, and spin. Impacts of nuclear physics on astrophysics and the scientific and societal benefits of nuclear physics are then discussed. Another section deals with scientific frontiers, describing research into the realm of the quark-gluon plasma; the changing description of nuclear matter, specifically the use of the quark model; and the implications of the standard model and grand unified theories of elementary-particle physics; and finishes with recommendations and priorities for nuclear physics research facilities, instrumentation, accelerators, theory, education, and data bases. Appended are a list of national accelerator facilities, a list of reviewers, a bibliography, and a glossary.

Source record↗

Structural dynamic model obtained from flight use with piloted simulation and handling qualities analysis

The ability to use flight data to determine an aircraft model with structural dynamic effects suitable for piloted simulation. and handling qualities analysis has been developed. This technique was demonstrated using SR-71 flight test data. For the SR-71 aircraft, the most significant structural response is the longitudinal first-bending mode. This mode was modeled as a second-order system, and the other higher order modes were modeled as a time delay. The distribution of the modal response at various fuselage locations was developed using a uniform beam solution, which can be calibrated using flight data. This approach was compared to the mode shape obtained from the ground vibration test, and the general form of the uniform beam solution was found to be a good representation of the mode shape in the areas of interest. To calibrate the solution, pitch-rate and normal-acceleration instrumentation is required for at least two locations. With the resulting structural model incorporated into the simulation, a good representation of the flight characteristics was provided for handling qualities analysis and piloted simulation.

Powers, Bruce G.↗

Space experiments with particle accelerators (SEPAC): Description of instrumentation

SEPAC (Space Experiments with Particle Accelerators) flew on Spacelab 1 (SL 1) in November and December 1983. SEPAC is a joint U.S.-Japan investigation of the interaction of electron, plasma, and neutral beams with the ionosphere, atmosphere and magnetosphere. It is scheduled to fly again on Atlas 1 in August 1990. On SL 1, SEPAC used an electron accelerator, a plasma accelerator, and neutral gas source as active elements and an array of diagnostics to investigate the interactions. For Atlas 1, the plasma accelerator will be replaced by a plasma contactor and charge collection devices to improve vehicle charging meutralization. This paper describes the SEPAC instrumentation in detail for the SL 1 and Atlas 1 flights and includes a bibliography of SEPAC papers.

Taylor, W. W. L.↗

A Flight Evaluation of an Airborne Physiological Instrumentation System, Including Preliminary Results Under Conditions of Varying Accelerations

A physiological instrumentation system capable of recording the electrocardiogram, pulse rate, respiration rate, and systolic and diastolic blood pressures during flight has been developed. This instrumentation system was designed for use during control studies at varied levels of acceleration in order to monitor the well-being of the pilot and at the same time to obtain data for study of the relationships between his various physiological functions and his performance capability. Flights, made in a T-33 aircraft, demonstrated the ability of the system to obtain the desired physiological data in flight. The data obtained in these flights, although limited in nature, indicate a slowing of the pulse rate under the subgravity conditions of brief duration. There appeared to be a proportional nearly in-phase relationship between pulse rate and acceleration. A decrease in diastolic blood pressure together with an increase in pulse pressure was noted during subgravity conditions and an elevation of the diastolic pressure together with a decrease in pulse pressure du-ring increased accelerations. No change worthy of note was seen in the records of the systolic blood pressure, the respiration rate, or the electrocardiogram over the range of acceleration studied (0 to 3 g).

Smedal, Harald A.↗

Space Experiments with Particle Accelerators (SEPAC)

The space experiments with particle accelerators (SEPAC) instruments consist of an electron accelerator, a plasma accelerator, a neutral gas (N2) release device, particle and field diagnostic instruments, and a low light level television system. These instruments are used to accomplish multiple experiments: to study beam particle interactions and other plasma processes; as probes to investigate magnetospheric processes; and as perturbation devices to study energy coupling mechanisms in the magnetosphere, ionosphere, and upper atmosphere.

Roberts, W. T.↗

Instrument Records And Plays Back Acceleration Signals

Small, battery-powered, hand-held instrument feeds power to accelerometer and records time-varying component of output for 15 seconds in analog form. No power needed to maintain content of memory; memory chip removed after recording and stored indefinitely. Recorded signal plays back at any time up to several years later. Principal advantages: compactness, portability, and low cost.

Bozeman, Richard J.↗

Miniature Ion-Mobility Spectrometer

The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to generate a moderate electric field. Positive ions leaving the membrane holes would be accelerated in this electric field. The resulting flux of ions away from the ionization membrane would create a partial vacuum that would draw more of the gas medium through the membrane. The figure depicts a filter electrode and detector electrodes located along the sides of a drift tube downstream from the accelerator electrode. These electrodes would apply a transverse AC electric field superimposed on a ramped DC electric field. The AC field would effect differential transverse dispersal of ions. At a given instant of time, the trajectories of most of the ions would be bent toward the electrodes, causing most of the ions to collide with the electrodes and thereby become neutralized. The DC field would partly counteract the dispersive effect of the AC field, straightening the trajectories of a selected species of ions; the selection would vary with the magnitude of the applied DC field. The straightening of the trajectories of the selected ions would enable them to pass into the region between the detector electrodes. Depending on the polarity of the voltage applied to the detector electrodes, the electric field between the detector electrodes would draw the selected ions to one of these electrodes. Hence, the current collected by one of the detector electrodes would be a measure of the abundance of ions of the selected species. The ramping of the filter- electrode DC voltage would sweep the selection of ions through the spectrum of ionic species.

Hartley, Frank T.↗

Instrument automatically selects peak acceleration signal from several accelerometers

Solid state circuit selects the highest of several ac accelerometer signals and gates this signal to an output amplifier, preserving all the frequency information in the peak signal. If the amplitudes of the accelerometer signals change with time, the circuit will continually switch to the highest signal, rejecting the smaller signals.

Chapman, C. P.↗

OARE and SAMS on STS-94/MSL-1

Four microgravity acceleration measurement instruments were included on MSL-1 to measure the accelerations and vibrations to which science experiments were exposed during their operation on the mission. The data were processed and presented to the principal investigators in a variety of formats to aid their assessment of the microgravity environment during their experiment operations. Two accelerometer systems managed by the NASA Lewis Research Center (LeRC) supported the MSL-1 mission: the Orbital Acceleration Research Experiment (OARE), and the Space Acceleration Measurement System (SAMS). In addition, the Microgravity Measurement Assembly (MMA) and the Quasi- Steady Acceleration Measurement (QSAM) system, both sponsored by the Microgravity Research Division, collected acceleration data as a part of the MSL-1 mission. The NIMA was funded and designed by the European Space Agency in the Netherlands (ESA/ESTEC), and the QSAM system was funded and designed by the German Space Agency (DLR). The Principal Investigator Microgravity Services (PIMS) project at the NASA Lewis Research Center (LeRC) supports Principal Investigators (PIs) of the Microgravity science community as they evaluate the effects of acceleration on their experiments. PIMS primary responsibility is to support NASA-sponsored investigators in the area of acceleration data analysis and interpretation. A mission summary report was prepared and published by PIMS in order to furnish interested experiment investigators with a guide for evaluating the acceleration environment during the MSL-1 mission.

Moskowitz, Milton↗

Space experiments with particle accelerators: SEPAC

The SEPAC instruments consist of an electron accelerator, a plasma accelerator, a neutral gas (N2) release device, particle and field diagnostic instruments, and a low light level television system. These instruments are used to accomplish multiple experiments: to study beam-particle interactions and other plasma processes; as probes to investigate magnetospheric processes; and as perturbation devices to study energy coupling mechanisms in the magnetosphere, ionosphere, and upper atmosphere.

Roberts, B.↗

Feasibility of miniaturized instrumentation of the inflatable sphere for temperature, pressure and acceleration measurement

The feasibility of instrumenting the inflatable passive sphere (presently used to provide upper atmosphere density measurements) with miniaturized thermistors, pressure transducers, and accelerometers was analyzed. Data from the sensors must be transmitted by an onboard telemetry system to a ground receiving station. To assure a sufficiently slow fall velocity for the sphere the additional mass of the sensor and telemetry hardware must be less than 100 grams. Other constraints that must be satisfied by the sensor and telemetry systems include the ability to withstand a 150 g launch acceleration, the ability to function in both high and low temperature and pressure environments and be sufficiently small to be packaged within the body of a 3.81 cm diameter dart. A differential transducer that will measure the difference between ambient and internal sphere pressures is recommended. The application of each type of measurement relative to its ability to monitor sphere malfunction and to provide additional meteorological data is considered.

Luers, J. K.↗

A feasibility study of a hypersonic real-gas facility

A four month feasibility study of a hypersonic real-gas free flight test facility for NASA Langley Research Center (LARC) was performed. The feasibility of using a high-energy electromagnetic launcher (EML) to accelerate complex models (lifting and nonlifting) in the hypersonic, real-gas facility was examined. Issues addressed include: design and performance of the accelerator; design and performance of the power supply; design and operation of the sabot and payload during acceleration and separation; effects of high current, magnetic fields, temperature, and stress on the sabot and payload; and survivability of payload instrumentation during acceleration, flight, and soft catch.

Gully, J. H.↗