SEARCH · Search NASA
Results for “Accelerators,ACCPHY, XFEL”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Polarization control in an X-ray free-electron laser
X-ray free-electron lasers are unique sources of high-brightness coherent radiation. However, existing devices supply only linearly polarized light, precluding studies of chiral dynamics. A device called the Delta undulator has been installed at the Linac Coherent Light Source (LCLS) to provide tunable polarization. With a reverse tapered planar undulator line to pre-microbunch the beam and the novel technique of beam diverting, hundreds of microjoules of circularly polarized X-ray pulses are produced at 500–1,200 eV. These X-ray pulses are tens of femtoseconds long, have a degree of circular polarization of 0.98 –0.04 +0.02 at 707 eV and may be scanned in energy. We also present a new two-colour X-ray pump–X-ray probe operating mode for the LCLS. As a result, energy differences of ΔE/E = 2.4% are supported, and the second pulse can be adjusted to any elliptical polarization. In this mode, the pointing, timing, intensity and wavelength of the two pulses can be modified.
Compact Laser-Plasma-Accelerator-Driven Free-Electron Laser using a Transverse Gradient Undulator
Abstract Not Provided
Microbunching-instability-induced sidebands in a seeded free-electron laser
Not Available
Beam shaping to improve the free-electron laser performance at the Linac Coherent Light Source
Not Available
Longitudinal dynamics of twin electron bunches in the Linac Coherent Light Source
Not Available
Time-resolved imaging of the microbunching instability and energy spread at the Linac Coherent Light Source
Not Available
Soft x-ray self-seeding simulation methods and their application for the Linac Coherent Light Source
Not Available
Generalized Representation of Electric Fields in Sheet Beam Klystron Gaps
Abstract Not Provided
Developing Sheet Beam Klystron Simulation Capability in AJDISK
Abstract Not Provided
Microbunching phenomena in LCLS-II
The microbunching instability has long been recognized as a potential limiting factor to the performance of X-ray FELs. It is of particular relevance in LCLS-II due, in part, to a layout that includes a long bypass beamline between the Linac and the undulators. Here we focus on two aspects of the instability that highlight the importance of 3D effects.
Echo-enabled harmonics up to the 75th order from precisely tailored electron beams
The production of coherent radiation at ever shorter wavelengths has been a long-standing challenge since the invention of lasers1, 2 and the subsequent demonstration of frequency doubling3. Modern X-ray free-electron lasers (FELs) use relativistic electrons to produce intense X-ray pulses on few-femtosecond timescales4, 5, 6. However, the shot noise that seeds the amplification produces pulses with a noisy spectrum and limited temporal coherence. To produce stable transform-limited pulses, a seeding scheme called echo-enabled harmonic generation (EEHG) has been proposed7, 8, which harnesses the highly nonlinear phase mixing of the celebrated echo phenomenon9 to generate coherent harmonic density modulations in the electron beam with conventional lasers. Here, we report on a demonstration of EEHG up to the 75th harmonic, where 32 nm light is produced from a 2,400 nm laser. We also demonstrate that individual harmonic amplitudes are controlled by simple adjustment of the phase mixing. Results show the potential of laser-based manipulations to achieve precise control over the coherent spectrum in future X-ray FELs for new science10, 11.
Preliminary Conceptual Design Report for the FACET-II Project at SLAC National Accelerator Laboratory
Plasma wakefield acceleration has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider is the focus of FACET, a National User Facility at SLAC. The existing FACET National User Facility uses part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and positrons. FACET-II is a new test facility to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. It is the only facility in the world with high energy positron beams. FACET-II provides a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique. It will synergistically pursue accelerator science that is vital to the future of both advanced acceleration techniques for High Energy Physics, ultra-high brightness beams for Basic Energy Science, and novel radiation sources for a wide variety of applications. The design parameters for FACET-II are set by the requirements of the plasma wakefield experimental program. To drive the plasma wakefield requires a high peak current, in excess of 10kA. To reach this peak current, the electron and positron design bunch size is 10μ by 10μ transversely with a bunch length of 10μ. This is more than 200 times better than what has been achieved at the existing FACET. The beam energy is 10 GeV, set by the Linac length available and the repetition rate is up to 30 Hz. The FACET-II project is scheduled to be constructed in three major stages. Components of the project discussed in detail include the following: electron injector, bunch compressors and linac, the positron system, the Sector 20 sailboat and W chicanes, and experimental area and infrastructure.
Cancellation of RF Coupler-Induced Emittance Due to Astigmatism
It is well-known that the electron beam quality required for applications such as FEL’s and ultra-fast electron diffraction can be degraded by the asymmetric fields introduced by the RF couplers of superconducting linacs. This effect is especially troublesome in the injector where the low energy beam from the gun is captured into the first high gradient accelerator section. Unfortunately modifying the established cavity design is expensive and time consuming, especially considering that only one or two sections are needed for an injector. Instead, it is important to analyze the coupler fields to understand their characteristics and help find less costly solutions for their cancellation and mitigation. This paper finds the RF coupler-induced emittance for short bunches is mostly due to the transverse spatial sloping or tilt of the field, rather than the field’s time-dependence. It is shown that the distorting effects of the coupler can be canceled with a static (DC) quadrupole lens rotated about the z-axis.
A new storage-ring light source
A recently proposed technique in storage ring accelerators is applied to provide potential high-power sources of photon radiation. The technique is based on the steady-state microbunching (SSMB) mechanism. As examples of this application, one may consider a high-power DUV photon source for research in atomic and molecular physics or a high-power EUV radiation source for industrial lithography. A less challenging proof-of-principle test to produce IR radiation using an existing storage ring is also considered.
Design and Implementation of Automatic Cavity Resonance Frequency Measurement and Tuning Procedure for FLASH and European XFEL Cryogenic Modules
Abstract Not Provided