Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spin-squeezing-enhanced dual-species atom interferometric accelerometer employing large momentum transfer for precision test of the equivalence principle

Here, we theoretically investigate the feasibility of applying spin squeezing to a light pulse atom interferometer in the presence of large momentum transfer using off resonant Raman transitions, in order to enhance the sensitivity of accelerometry close to the Heisenberg limit. We also show how to implement this scheme in a dual-species atom interferometer for a precision test of the equivalence principle by measuring the Eötvös parameter, and to identify the spin squeezing protocol that is best suited for such an experiment. For a space borne platform in low Earth orbit, such a scheme may eventually enable the measurement of the Eötvös parameter with a sensitivity of the order of 10 -20 within 150 days when 10 5 atoms are employed in each cycle of the experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Accelerometer Drift Study

Accelerometers are energy transducers that convert mechanical energy into an electrical signal. That electrical signal is proportional to the amount of mechanical stress the accelerometer was subjected to. Knowing this proportionality allows the electrical signal to be interpreted as an acceleration. There are three types of sensing technologies utilized in capacitors: piezoelectric, piezoresistive and capacitive. In this study, all of the accelerometers utilized are of the piezoelectric type and purchased from one particular vendor, MEGGITT. The piezoelectric effect is the phenomena by which a material generates an electrical charge when subjected to a mechanical stress. A piezoelectric accelerometer will not generate an electrical charge when placed in a static acceleration field because no stress will be placed on the piezoelectric element. However if the acceleration field is dynamic, the piezoelectric element will generate an electrical charge. So the types of accelerations these accelerometers are measuring are dynamic in nature, such as vibrations. Knowledge of dynamic acceleration is useful in characterizing the structural response of some object. The sensitivity of an accelerometer is the ratio of its electrical output to mechanical input. The more sensitive an accelerometer is, the greater the value of the electrical output to a given mechanical input. An accelerometer’s sensitivity is known to drift over time. The objective of this study is to quantify this drift. Questions to answer are: Does the accelerometer become more or less sensitive over time and by how much. This is important to understand because this will establish a time frame of when readings from the accelerometer can be utilized. The larger this time frame is the better because that would preclude the need to purchase accelerometers frequently, which saves on costs. This would further bolster the relationship between MEGGITT and LANL if it is found that MEGGITT produces accelerometers that can be used for a relatively long period of time. This would create less uncertainty in picking a vendor for accelerometers.

42 ENGINEERING↗

Method and apparatus for determining a normal combustion characteristic for an internal combustion engine from an accelerometer signal

The method comprises operating a calibration engine, and collecting combustion characteristic data and reference accelerometer signals, which are correlated with each other and stored in a calibration table. The calibration table can be used by an engine to determine a real-time normal combustion characteristic when the engine is operating by collecting a real-time accelerometer sensor signal and cross correlating with the correlated data stored in the calibration table. Accordingly, the apparatus comprises a calibration engine comprising a calibration sensor, a reference accelerometer sensor and a data storage device for storing the collected calibration data that is correlated with the collected reference accelerometer signals, and an engine equipped with an accelerometer sensor, a calibration table and an electronic engine controller programmed to receive real-time accelerometer signals and cross correlate them with reference accelerometer signals to determine a real-time normal combustion characteristic.

Huang, Jian↗

A Comprehensive Analysis of Real-World Accelerometer Data Quality in a Global Smartphone-based Seismic Network

The proliferation of low-cost sensors in smartphones has facilitated numerous applications; however, large-scale deployments often encounter performance issues. Sensing heterogeneity, which refers to varying data quality due to factors such as device differences and user behaviors, presents a significant challenge. In this research, we perform an extensive analysis of 3-axis accelerometer data from the MyShake system, a global seismic network utilizing smartphones. We systematically evaluate the quality of approximately 22 million 3-axis acceleration waveforms from over 81 thousand smartphone devices worldwide, using metrics that represent sampling rate and noise level. We explore a broad range of factors influencing accelerometer data quality, including smartphone and accelerometer manufacturers, phone specifications (release year, RAM, battery), geolocation, and time. Our findings indicate that multiple factors affect data quality, with accelerometer model and smartphone specifications being the most critical. In addition, we examine the influence of data quality on earthquake parameter estimation and show that removing low-quality accelerometer data enhances the accuracy of earthquake magnitude estimation.

58 GEOSCIENCES↗

Microcantilevers with embedded accelerometers for dynamic atomic force microscopy

The measurement of the intermittent interaction between an oscillating nanotip and the sample surface is a key challenge in dynamic Atomic Force Microscopy (AFM). Accelerometers integrated onto AFM cantilevers can directly measure this interaction with minimal cantilever modification but have been difficult to realize. Here, we design and fabricate high frequency bandwidth accelerometers on AFM cantilevers to directly measure the tip acceleration in commercial AFM systems. We demonstrate a simple way of calibrating such accelerometers and present experiments using amplitude modulated AFM on freshly cleaved mica samples in water to study the response of the accelerometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lunar accelerometer network gravitational observatory (LANGO)

With ground-based interferometers detecting hundreds of gravitational-wave (GW) events, GW astronomy has continued to blossom. U.S. and European scientists are developing plans to construct third-generation ground-based interferometers. ESA has proceeded through the mission formulation phase of space-based interferometer in a lower-frequency band, 10 –4 –0.1 Hz. Despite all these exciting developments, there is still a missing frequency band, 0.1–10 Hz. This mid-frequency band is rich with interesting astrophysical events. Coalescence and merger of intermediate-mass black holes (IMBHs) will occur in this frequency band. Coalescing stellar-mass BHs will pass through this frequency band days before they reach the frequency band of LIGO and Virgo. Detection of such signals would enable a mid-frequency detector to issue an advance notice to the high-frequency GW detectors, as well as to optical, x-ray and γ-ray telescopes. We propose Lunar Accelerometer Network Gravitational Observatory (LANGO) to detect GWs in this frequency band. In the first phase (LANGO 1), we propose to deploy four ambient-temperature (250 K) accelerometers in the tetrahedral or in a square configuration on the hemisphere facing the Earth. After successful operation at 250 K, LANGO would be upgraded to a cryogenic (4 K) version with over two orders of magnitude increased sensitivity (LANGO 2), with coherent rejection of seismic noise implemented. LANGO is a full-tensor detector, capable of determining the source direction and wave polarization. Each test mass (TM) is suspended as a pendulum with resonance frequency ∼ 0.01 Hz, thus is only weakly coupled to the lunar surface horizontally. LANGO is designed to detect the relative motion of globally separated, nearly free, TMs by using the Moon as a large quiet platform. LANGO 1 and 2 accelerometers aim at sensitivities ⩽ 10 –11 m s –2 Hz –1/2 and ⩽ 10 –13 m s –2 Hz –1/2 in the horizontal axes over the frequency band of 1 mHz–10 Hz, which yield GW sensitivities 1.1 x 10 -21 Hz -1/2 and 3.8 x 10 -24 Hz -1/2 at 1 Hz, respectively. The LANGO accelerometers will be 10 3 –10 5 times more sensitive than Apollo seismometers. With such sensitivity, LANGO will also make great contribution to the advancement of lunar geophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Method and apparatus for using an accelerometer signal to detect misfiring in an internal combustion engine

The method comprises operating an engine and collecting a real-time accelerometer signal from an accelerometer sensor. The real-time accelerometer signal is digitized and filtered to isolate data in a frequency range associated with combustion to produce a filtered signal data set. The filtered signal data set is integrated to produce an integrated signal data set, and misfire is detected by comparing the integrated signal data set with a predetermined reference data set associated with the same operating point. The apparatus is a control system for an engine that comprises an accelerometer sensor mounted to the engine; a look-up table in which is stored predetermined reference data sets, in association with predetermined operating conditions; and an electronic controller programmed to carry out the foregoing method.

33 ADVANCED PROPULSION SYSTEMS↗

Piezoelectric accelerometers for ultrahigh temperature application

High temperature sensors are of major importance to aerospace and energy related industries. In this letter, a high temperature monolithic compression-mode piezoelectric accelerometer was fabricated using YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) single crystals. The performance of the sensor was tested as function of temperature up to 1000 deg. C and over a frequency range of 100-600 Hz. The accelerometer prototype was found to possess sensitivity of 2.4+-0.4 pC/g, across the measured temperature and frequency range, indicating a low temperature coefficient. Furthermore, the sensor exhibited good stability over an extended dwell time at 900 deg. C, demonstrating that YCOB piezoelectric accelerometers are promising candidates for high temperature sensing applications.

36 MATERIALS SCIENCE↗

Piezoelectric Shaker Development for High Frequency Calibration of Accelerometers

Calibration of vibration transducers requires sinusoidal motion over a wide frequency range with low distortion and low cross-axial motion. Piezoelectric shakers are well suited to generate such motion and are suitable for use with laser interferometric methods at frequencies of 3 kHz and above. An advantage of piezoelectric shakers is the higher achievable accelerations and displacement amplitudes as compared to electro-dynamic (ED) shakers. Typical commercial ED calibration shakers produce maximum accelerations from 100 m/s{sup 2} to 500 m/s{sup 2}. Very large ED shakers may produce somewhat higher accelerations but require large amplifiers and expensive cooling systems to dissipate heat. Due to the limitations in maximum accelerations by ED shakers at frequencies above 5 kHz, the amplitudes of the generated sinusoidal displacement are frequently below the resolution of laser interferometers used in primary calibration methods. This limits the usefulness of ED shakers in interferometric based calibrations at higher frequencies.Small piezoelectric shakers provide much higher acceleration and displacement amplitudes for frequencies above 5 kHz, making these shakers very useful for accelerometer calibrations employing laser interferometric measurements, as will be shown in this paper. These piezoelectric shakers have been developed and used at NIST for many years for high frequency calibration of accelerometers. This paper documents the construction and performance of a new version of these shakers developed at NIST for the calibration of accelerometers over the range of 3 kHz to 30 kHz and possibly higher. Examples of typical calibration results are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybridizing matter-wave and classical accelerometers

We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performance without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely, the dead times between consecutive measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

ACCELEROMETERS IN FLOW FIELDS: A STRUCTURAL ANALYSIS OF THE CHOPPED DUMMY INPILE TUBE

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s2 in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerometers in flow fields: a structural analysis of the chopped dummy in-pile tube

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s{sup 2} in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design. (authors)

42 ENGINEERING↗

A modified Hopkinson pressure bar experiment to evaluate a damped piezoresistive MEMS accelerometer.

We conducted a series of modified Hopkinson pressure bar (HPB) experiments to evaluate a new, damped, high-shock accelerometer that has recently been developed by PCB Piezotronics Inc. Pulse shapers were used to create a long duration, non-dispersive stress pulse in an aluminum bar that interacted with a tungsten disk at the end of the incident bar. We measured stress at the aluminum bar-disk interface with a quartz gage and measured acceleration at the free-end of the disk with an Endevco brand 7270A and the new PCB 3991 accelerometers. The rise-time of the incident stress pulse in the aluminum bar was long enough and the disk length short enough so that the response of the disk can be approximated closely as rigid-body motion; an experimentally verified analytical model has been shown previously to support this assumption. Since the cross-sectional area and mass of the disk were known, we calculated acceleration of the rigid-disk from the quartz-gage force measurement and Newton's Second Law of Motion. Comparisons of accelerations calculated from the quartz-gage data and measured acceleration data show excellent agreement for acceleration pulses with the PCB accelerometer for peak amplitudes between 4,000 and 40,000 Gs , rise times as short as 40 microsec, and pulse durations between 150 and 320 microsec.

47 OTHER INSTRUMENTATION↗

Distributed Accelerometer IMU-2: An Interim Development Report

This report details the development of DAIMU-2, a MEMS accelerometer-based Gyro-Free Inertial Measurement Unit (GF-IMU). Previously, a GF-IMU called the Distributed Accelerometer IMU (DAIMU) was developed at LLNL using traditional analog accelerometers. This project leverages the experience gained from DAIMU and recent advances in sensor and embedded systems technology to develop DAIMU-2. The report introduces the theory and mathematics of a GF-IMU, followed by the design of an Unscented Kalman Filter (UKF) and simulation results. Finally, the DAIMU-2 prototypes developed to date are presented. After approximately one year of development work, the project was suspended, to be resumed in the future. Because of this, some efforts were partially completed, and this report attempts to indicate areas where further work is needed. MATLAB files, drawings, and other design documents have been archived for future project resumption.

42 ENGINEERING↗

Feasibility of an Accelerometer-Based Structural Health Monitoring System for the LANL Blast Tube

A modeling- and simulation-based study was conducted on the feasibility of implementing an accelerometer-based SHM system on the Los Alamos National Laboratory blast tube. A blast tube experiment was modeled using the Abaqus explicit finite element solver. A custom user subroutine was written to apply test-like pressure loading to the inside surface of the blast tube. The subroutine applies analytically defined pressure loads derived from tracer output taken from a Compressible Flow Computational Fluid Dynamics Solver model of the blast tube. Five unique versions of the model were created: an undamaged reference model at 65°F was used as the baseline and compared to equivalent models at 10°F and 100°F. These three models were compared to models with small damage at the reference temperature. The two types of damage considered were a radial (circumferential) crack in the main tube body and a longitudinal crack in the supports. Acceleration outputs were extracted from accelerometer bodies included in the model and were post processed using a variety of standard SHM techniques. Different potential features signaling failure were extracted and compared using statistical methods in the time and frequency domains. A method was identified that clearly shows that differences in structural response resulting from the modeled damage can be differentiated from the structural response resulting from changing environmental conditions. However, the amount of damage applied to create observable differences in the accelerometer data was so large that simpler methods of damage detection would be more cost effective in locating damage.

42 ENGINEERING↗

Micromachined force-balance feedback accelerometer with optical displacement detection

An accelerometer includes a proof mass and a frame that are formed in a handle layer of a silicon-on-an-insulator (SOI). The proof mass is separated from the frame by a back-side trench that defines a boundary of the proof mass. The accelerometer also includes a reflector coupled to a top surface of the proof mass. An optical detector is located above the reflector at the device side. The accelerometer further includes at least one suspension spring. The suspension spring has a handle anchor that extends downwards from the device side to the handle layer to mechanically support upward and downward movement of the proof mass relative to a top surface of the proof mass.

42 ENGINEERING↗

Launch accelerometer for model rocket

Systems and methods of detecting launch of a model rocket are described herein. A mechanically implemented launch accelerometer may be disposed on a model rocket. The launch accelerometer may detect acceleration of the rocket by a mass of the launch accelerometer moving relative to the rocket and against a spring force based on the rocket acceleration. The mass may comprise a first electrical contact that may contact a second electrical contact when the mass is accelerated beyond a threshold, which is indicative of launch of the rocket. The contact between the first electrical contact and the second electrical contact may complete an electrical circuit. Furthermore, at least one pin may lock the mass in a position allowing the electrical circuit to remain complete.

Boyson, Jonathan M.↗