Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accident tolerant fuel cladding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Semi-integral LOCA test of cold-spray chromium coated zircaloy-4 accident tolerant fuel cladding

Enhancing the accident tolerance of PWRs came under serious consideration following the 2011 Fukushima Daiichi nuclear power plant events. While the current nuclear fuels are based on mature technology and have an excellent operational record, further enhancing their strength through accident tolerant fuel (ATF) research and development continues to be of interest. Particularly, the chromium coated clad ATF technology represents an evolutionary change to improve the high temperature performance of existing Zircaloy claddings. Additionally, despite several years of investigation of coated cladding, the integral loss of coolant accident (LOCA) performance of chromium coated cladding has had little attention. In this work, cold-spray chromium coated zircaloy-4 claddings are evaluated using EDF's semi-integral LOCA test facility. Results show that the chromium coating induces a reduced ballooning and burst and an increased burst temperature in the investigated conditions. However, these tests exhibit limited benefits concerning the post-quench behavior of the coated specimens which occurs in the last stage of a prototypical LOCA scenario.

36 MATERIALS SCIENCE↗

The response of accident tolerant fuel cladding to LOCA burst testing: A comparative study of leading concepts

Accident tolerant fuel claddings seek to improve safety margins during loss-of-coolant accident (LOCA) scenarios by reducing cladding steam oxidation rates, hydrogen production, delaying or mitigating cladding burst, and reducing cladding deformation. After rapid and extensive progress in recent years, Cr coated Zr-based alloys, ferritic FeCrAl, and SiC/SiC ceramic matrix composites (CMCs) have emerged as the most promising cladding concepts, but there are few studies comparing the accident tolerance of all three concepts simultaneously. Here, in this study, LOCA burst testing has been conducted on Cr high impulse power magnetron sputtered Zry-4 (Cr/Zry-4), C26M (FeCrAl), and SiC/SiC SiGA (CMC). Experimental observations indicate Cr/Zry-4 burst at higher temperatures than Zry-4 however the effectiveness of the coating on mitigating ZrO 2 formation via Cr 2 O 3 formation depended on physical proximity to the burst opening. No dramatic improvement in diametrical strain nor opening geometry was observed. C26M burst at higher temperatures than Zry-4 at lower pressures, exhibiting small amounts of strain and smaller openings, and formed slow-growing Al 2 O 3 regardless of location. The CMCs did not burst or show any macroscopic signs of deformation, all the way up to an internal cladding pressure of 15.2 MPa. High temperature expanding Nb plug testing indicated that CMC room temperature strength may persist up to 1650°C, with an approximately 40% loss of strength at 1900°C. CMC steam oxidation was also compared to reference chemically vapor deposited SiC up to 1700°C, and CMCs were found to oxidize at slightly accelerated rates that were still orders of magnitude lower than bare Zry-4. Projected H 2 generation during LOCA burst testing showed that when accounting for cladding burst exposing inner diameters to steam, Cr coated Zry-4 reduced H 2 generation by a factor of two compared with bare Zry-4, while both C26M and SiC/SiC reduced H 2 generation by orders of magnitude relative to bare Zry-4.

36 MATERIALS SCIENCE↗

Investigations on the Thermal-hydraulic Behavior of Accident Tolerant Fuel Cladding Materials

Since the 2011 Fukushima accident, significant research has been devoted to developing accident-tolerant fuel (ATF) cladding materials. These investigations have mostly focused on the ability to resist runaway steam oxidation and retain mechanical strength and structural integrity under thermal shocks. However, much remains unknown about the materials’ thermal-hydraulic behavior, particularly under light-water reactor (LWR) operating conditions. Two phenomena that determine safety margins in both normal and off-normal operating conditions - i.e., the critical heat flux (CHF) and Leidenfrost point (LFP) temperature - have not been investigated thoroughly for ATF materials. Surface properties, such as wettability and roughness, are known to influence pool and flow boiling CHF, as well as the LFP temperature. However, little is known about the surface wettability of ATF materials, particularly at LWR pressure and temperature. Little has been done on flow-boiling CHF and quenching heat transfer, especially for droplet quenching. Nonetheless, it is known that CHF in transient conditions, e.g., an exponentially escalating power transient, can be significantly different from that expected in steady-state operation. Very few studies have investigated transient CHF, either on ATF materials or under LWR pressure and temperature. The thorough understanding of transient CHF under prototypical reactor conditions will benefit not only the deployment of ATF but also the upcoming national efforts to study transient ATF behavior in the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory. In summary, as a part of ATF development efforts, there is an urgent need to understand how and how much these materials may affect two-phase heat transfer phenomena in nuclear reactor conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Steam oxidation of chromium corrosion barrier coatings for sic-based accident tolerant fuel cladding

SiC-based materials are currently being considered for accident tolerant fuel (ATF) cladding, however, there are concerns regarding hydrothermal corrosion rates and hermeticity. These issues may be addressed with the utilization of a Cr corrosion barrier coating (CBC) but the interaction of Cr with SiC under loss of coolant accident (LOCA) conditions needs to be investigated. In the present work, Cr coatings were deposited onto chemically vapor deposited (CVD) SiC with either high power impulse magnetron sputtering (HiPIMS), cathodic arc (CA), or a combination of both. Annealing and steam thermogravimetric analysis (TGA) was used to study reaction product formation with and without oxidation. Additionally, after 1200 °C annealing, formation of a Cr x C y carbide layer at the ambient interface and a Cr x Si y C z silicide layer at the SiC interface was observed. After 1200 °C TGA exposure, similar carbide and silicide layers were observed but with a Cr 2 O 3 outer reaction layer and a Si and O rich interfacial layer forming between the carbide and silicide layers. Initial mass gain of the coatings during the 1200 °C TGA exposure was parabolic and were similar to reported rates of chromia formation. Mass gain behavior and observed transitions in chromia microstructure indicate that metallic Cr may be consumed within the first ~1 h at 1200 °C and that subsequent chromia formation occurs at the expense of the underlying Cr carbide layer. Overall, the results show no detrimental impact of Cr coatings on the steam oxidation resistance of SiC up to 4 h at 1200 °C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical heat flux on zircaloy and accident tolerant fuel cladding under prototypical conditions of pressurized and boiling water reactors

First of a kind high spatial and temporal resolution temperature measurements of Pressurized Water Reactor and Boiling Water Reactor simulated fuel pins (high heat flux cosine profile heaters) in annular rod type geometry during nucleate boiling, departure from nucleate boiling and re-wetting has been performed. Distributed fiber optic measurements of the cladding axial temperature with spatial resolutions down to 2.5 mm axially at up to three equally spaced azimuthal locations per rod have demonstrated the similarities and differences of the different accident tolerant fuel cladding materials. These experiments show the performance of accident tolerant cladding with a precise measurement of the location and evolution of dryout followed by the re-wetting phenomena (see supplementary time history of a critical heat flux event). Experimental parameters varied coolant mass fluxes from 1695 to 2712 kg/m 2 s, pressures from 10 to 20 MPa, and inlet subcooling from 10 to 55 °C. It was found that the coatings and different material have little effect on the value of the critical heat flux. Any discrepancies between the local critical heat flux verified among the cladding material are attributed to different departure from nucleate boiling phenomena captured during the experiment with the high-resolution optical fiber temperature data. Substantial differences in the performance of the different cladding material to survive a critical heat flux event were however observed by post-test X-ray and optical inspection. External evident damage and internal cracks to the simulated fuel pin having the bare zircaloy cladding were observed in regions associated with the occurrence of the critical heat flux for longer periods. Such damages were associated with zirconium oxidation, and not noticed on the Cr coated zircaloy or FeCrAl claddings. These results indicate that the use of FeCrAl or a Cr coated zircaloy as cladding in Pressurized Water Reactor and Boiling Water Reactor may increase the survivability of the cladding material for short transients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent progresses on thermal–hydraulics evaluations of accident tolerant fuel cladding materials

Thermal–hydraulics (T-H) experiments have been on the progress to evaluate boiling heat transfer characteristics of accident tolerant fuel (ATF) candidates for further supporting the core-loading of these advanced ATF concepts in light water reactors (LWRs). Here this study covers recent experimental studies of ATF claddings and summarizes some significant results. Recent T-H experimental results of ATF cladding candidates demonstrated that the material thermal–physical properties have pronounced effects on critical heat flux (CHF). Such effects have not been well resolved in the current physics-governing models. These effects of cladding materials on CHF could be potentially rationalized by the material-conjugated boiling heat transfer, where the material-dominated heat conduction competes with the flow boiling-dominated heat convection. As progressively increasing the mass flux and/or liquid subcooling, CHF differences between different materials gradually decrease, which is in agreement with the recent T-H experimental results of ATF claddings. This is because the dominance of heat convection over heat conduction is primarily improved by liquid subcooling and/or mass flow rate. It is noteworthy that surface oxidization of claddings may have unknown impacts on T-H performances because the formation of oxide layers on cladding surfaces introduces variations of material thermal–physical properties and then changes the surface morphological features, which results in some difficulties in evaluating the thermal safety margins of ATF claddings.

36 MATERIALS SCIENCE↗

Grid-to-rod fretting wear study of SiC/SiC composite accident-tolerant fuel claddings using an autoclave fretting bench test

Grid-to-rod-fretting (GTRF) in pressurized water reactors (PWRs) is known to cause wear and surface damage on the fuel claddings, potentially leading to radioactive leakage. One of the accident-tolerant fuel (ATF) concepts is to use advanced cladding materials that could withstand higher temperatures. Here, we investigated the wear behavior of candidate silicon carbide (SiC)-based composite claddings with different levels of surface finish in fretting against a commercial ZIRLO alloy grid using a unique bench-scale autoclave GTRF rig. The experiments mimicked the environment in an industrial full-assembly PWR simulator. Fretting tests were conducted with a realistic load (~0.5 N) in deionized water under a pressure of 20–23 bar at 204 °C for 100 h. While the SiC/SiC composite claddings showed significantly higher wear resistance than the commercial ZIRLO alloy cladding as expected, the smoother versions experienced surprisingly higher wear than the much softer counterface, ZIRLO grid. The wear mechanism of the SiC/SiC cladding was attributed to the SiC wear debris that was trapped at the fretting interface causing both 3-body and 2-body (embedded into the grid surface) abrasion of the cladding. Rougher SiC/SiC claddings had less material loss but caused more wear on the ZIRLO grid. Finally, pre-oxidized ZIRLO grid showed better compatibility with the SiC/SiC cladding to protect both the cladding and grid as a result of reduced wear debris trapping.

36 MATERIALS SCIENCE↗

Effects of Cr/Zircaloy-4 coating qualities for enhanced accident tolerant fuel cladding

Cr-coated zirconium alloys represent a modern approach to enhance cladding safety during accident scenarios. Two high-power impulse magnetron sputtered Cr-coated Zry-4 systems were subjected to simulated loss-of-coolant accident conditions to investigate cladding performance. The first Cr-coating (4.8 µm thick) was deposited onto Zry-4 cladding and exhibited through-thickness cracking while the second Cr-coating (6.8 µm thick) was deposited with improved deposition parameters onto polished Zry-4 and exhibited no cracking. During burst testing, the coating with a higher density of defects failed to consistently reduce oxidation and exhibited similar burst behavior as Zry-4. In contrast, the second Cr-coating reduced ZrO 2 formation through formation of Cr 2 O 3 and displayed enhanced burst temperatures by ~80 °C compared to Zry-4. Utilizing an empirical relation for burst behavior of zirconium alloys, the 6.8 µm Cr/Zry-4 system displayed enhanced burst temperatures equivalent to an effective 0.464 mm increase in Zry-4 wall thickness, highlighting the value of continuous Cr coatings for accident scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of the effects of neutron irradiation on first-generation corrosion mitigation coatings on SiC for accident-tolerant fuel cladding

In this work, high purity SiC and SiC/SiC composites coated with commercial TiN, Cr, CrN, or CrN/Cr multilayer coatings were irradiated in Ar or flowing PWR water in the Massachusetts Institute of Technology Nuclear Reactor Laboratory (MITR). Irradiation in Ar was performed in the core. In the water environment, identical samples were placed in one of three different locations: in-core, providing exposure to neutron damage and radiolysis-affected water; above-core, where samples were exposed to radiolysis-affected water but not neutron damage, or outside of the core, where samples were exposed to the coolant water without the effects of radiation. Radiation in Ar revealed significant cracking of all but the TiN coatings, attributed to differential swelling between the coating and substrate. Lattice swelling was not observed in any of the coatings, but 0.2% void swelling was observed in the Cr coating. All of the coatings failed during water exposures in the core. Likewise, CrN/Cr spalled in each condition. Cr was protective, except under radiation damage as a result of cracking, and TiN severely degraded in the core with no coating was found following exposure. A SiC/coating ATF cladding system is anticipated to perform adequately following improvements in coating ductility and purity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Permeation in FeCrAl APMT Alloy for Accident Tolerant Fuel Cladding

Iron-chromium-aluminum (FeCrAl) alloys such as APMT (advanced powder metallurgy tubing) are candidate materials to replace zirconium alloys for the light water reactor fuel cladding. This alloy meets the requirements to be a material more tolerant of high-temperature accidents than the current zirconium alloys. One concern is that the use of FeCrAl may result in an increase in tritium presence in the coolant compared to the current design. The aim of the current research was to obtain effective diffusion coefficients (D eff ) for hydrogen through APMT using the Devanathan-Stachurski cell. Results showed that at 30°C the D eff value was 2.8 × 10 -8 cm 2 /s. Results also showed a linear relationship between the permeated hydrogen flux and the inverse of the test specimen thickness, which demonstrated the validity of the permeation measurements.

36 MATERIALS SCIENCE↗

Hydrothermal corrosion of 2nd generation FeCrAl alloys for accident tolerant fuel cladding

As part of an effort to develop advanced fuel cladding for use in light water reactors, several FeCrAl alloys have been developed at Oak Ridge National Laboratory. A second generation of these alloys bearing additional alloying elements over the previously tested model alloys were tested in boiling water reactor (BWR) conditions to determine their resistance to hydrothermal corrosion. Coupons with alloy compositions Fe–10Cr–6Al–2Mo, Fe–13Cr–5Al–2Mo, Fe–13Cr–6Al–2Mo, Fe–13Cr–7Al–2Mo, and Fe–13Cr–5Al–2Mo–1Nb were tested in normal water chemistry (NWC) and hydrogen water chemistry (HWC) for 9 months in continuously refreshing autoclaves. Commercial FeCrAl alloy APMT and Zircaloy-2 were also tested for comparison. Among samples exposed to HWC, Fe–13Cr–7Al–2Mo performed worst with an average mass loss of 1.3 mg/cm2 over 9 months. This mass loss represents an estimated thickness loss of approximately 60 μm over 6 years. Samples exposed to NWC had very small mass losses of less than 0.15 mg/cm2 or mass gains up to 0.05 mg/cm2. Based on the results of this testing, the 2nd generation FeCrAl alloys tested exhibit low wall thickness loss and are suitable in terms of corrosion resistance for use as LWR cladding in BWR-HWC and BWR-NWC under normal operating conditions.

Raiman, Stephen↗

Hydrothermal Corrosion of First-Generation Dual-Purpose Coatings on Silicon Carbide for Accident-Tolerant Fuel Cladding

In this study, four different commercial coatings, TiN, Cr, CrN, and Cr/CrN (multilayer) were deposited by physical vapor deposition (PVD) on high resistivity chemical vapor deposited (CVD) SiC for the dual purpose of corrosion mitigation and fission gas hermeticity. The coatings were exposed for up to 2600 hours in flowing high temperature (288-350°C), high purity, liquid water with dissolved hydrogen (0.15-3ppm) or dissolved oxygen (1-2ppm). The Cr/CrN coatings did not adhere well and spalled quickly during exposure. In oxygenated conditions, none of the coatings were protective . CrN coatings spalled preferentially at defect sites, but reacted slowly enough in the absence of defects to potentially be chemically protective. TiN coatings fully oxidized within a few hundred hours and spalled. In hydrogen, all the coatings were chemically stable. Coating failures were identified and attributed to localized spallation, potentially related to coating defects. Coating improvements are recommended to reduce spallation and improve coating protection for future generations of dual-purpose coatings.

36 MATERIALS SCIENCE↗