Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acoustic focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Acoustic focusing of microplastics in microfabricated and steel tube devices: An experimental study on the effects from particle size and medium density

The contamination of aquatic systems with microplastics is becoming a severe threat to living organisms. Microplastics found in the environment consist of a wide range of particle sizes thus give rise to several challenges to current purification methods. Acoustic focusing has been utilized as a particle concentrating method in biological and non-biological applications. In this study, we investigate the feasibility of using acoustic focusing technology to isolate microplastics in aqueous samples and find that a two-stage mechanism is essential to concentrate microplastics of wide size ranges of the same material. We demonstrate for the first time experimentally that when the particle size is comparable to the resonance wavelength, they deviate from typical pressure nodal focusing and show pressure antinodal focusing. Further, we have expanded microplastics isolation beyond microfluidic systems and demonstrate their extraction capabilities relatively at higher flow rates using microplastics of polystyrene, polyethylene, and polymethyl methacrylate ranging from 6 µm to 300 µm diameter and in devices fabricated with cylindrical steel tubes. We could extract 70% of microplastics smaller than 180 µm and 82% of microplastics greater than 180 µm in diameter from an aqueous sample at a flow rate of 12 mL/min. In conclusion, we demonstrate that small microplastics focus on acoustic pressure nodes regardless of the medium density. However, focusing of large microplastics of the same material depends on the medium density.

42 ENGINEERING↗

Polymer coating of glass microballoons levitated in a focused acoustic field

Inertial confinement fusion (ICF) glass microballoons (GMBs) levitated in a focusing radiator acoustic device can be coated with liquid materials by deploying the liquid into the levitation field with a stepped-horn atomizer. The GMB can be forced to the center of the coating liquid with a strong acoustically generated centering force. Water solutions of organic polymers, UV-curable liquid organic monomers, and paraffin waxes have been used to prepare solid coatings on the surface of GMBs using this technique.

Young, A. T.↗

Photoacoustic cell using elliptical acoustic focusing

A photoacoustic cell has been developed in the form of an elliptical cylinder in which essentially all the acoustic energy generated by a laser beam passing down one axis is focused onto a cylindrical acoustic tranducer located along the other axis. Preliminary measurements on a liquid-filled cell of this design show high sensitivity and a notably clean impulse response. A similar design may be useful for photoacoustic measurements in vapors as well.

Heritier, J.-M.↗

Time-reversed nonlinear acoustics for wellbore integrity characterization

A pulsed sinusoidal acoustic signal transmitted through a subsurface volume of a wellbore may be detected. A time-reversed acoustic signal of the pulsed sinusoidal acoustic signal may be transmitted through the subsurface volume of the wellbore. Transmission of the time-reversed acoustic signal through the subsurface volume of the wellbore may result in generation of focused acoustic signal in the subsurface volume of the wellbore. The focused acoustic signal in the subsurface volume of the wellbore may be detected, and the integrity of the wellbore may be determined based on the focused acoustic signal in the subsurface volume of the wellbore.

Ulrich, II, Timothy James↗

Lamb Wave Focusing Transducer for Efficient Coupling to Wavelength-Scale Structures in Thin Piezoelectric Films

This study describes the theoretical and experimental investigation of interdigitated transducers (IDTs) capable of producing focused acoustical beams in thin film piezo-electric materials. A mathematical formalism describing focused acoustical beams, Lamb beams, is presented and related to their optical counterparts in two- and three-dimensions. A novel Fourier domain transducer design methodology was developed and utilized to produce near diffraction limited focused beams with in a thin film AlN membrane. The properties of the acoustic beam formed by the transducer were studied by means of Doppler vibrometry implemented with a scanning confocal balanced homodyne interferometer. Fourier domain modal analysis confirmed that 85% of the acoustical power was delivered to the targeted focused beam which was constituted from the lowest order symmetric mode, while 2% was delivered unintentionally to the beam formed from the anti-symmetric mode, and the remaining power was isotropically scattered. The transmission properties of the acoustic beams as they interact with devices with wavelength scale features were also studied, demonstrating minimal insertion loss for devices in which a subwavelength, pinhole apertures was included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

Damage detection in a laboratory-scale wellbore applying Time Reversal and Nonlinear Elastic Wave Spectroscopy (TR NEWS)

We report Time Reversal and Nonlinear Elastic Wave Spectroscopy (TR-NEWS) has been used to focus acoustic energy, and make measurements correlated with damage in a variety of industrial materials. Most studies using TR-NEWS have focused on relatively small objects and may have multiple acoustic sources. In Earth, within energy extraction and carbon sequestration settings, the structure and scale of wellbores makes acoustic focusing challenging, as has been demonstrated through numerical simulations. This paper explores the feasibility of applying TR NEWS for damage detection in wellbores by constructing a laboratory-scale wellbore, and using TR to focus and make dynamic linear and nonlinear elastic measurements on it. During successive cycles of localized mechanical damage induced in the sample, the hysteretic nonlinear elastic parameter α increased with progressive mechanical damage. In addition to these strain-dependent changes in α, the width and peak amplitude of the time reversal focused energy changed near the damage site.

58 GEOSCIENCES↗

Acoustophoretic Additive Manufacturing for Scalable 3D Battery Electrodes

This project focused on investigating two acoustic-based processing methods: a nozzle-based printhead and a chamber that map to two different battery electrode architectures: (1) a line-pattern electrode and (2) a grid-pattern electrode. These two parallel manufacturing and electrode geometry explorations were proposed for the project to understand the process space of acoustic-based manufacturing methods to fabricate patterned battery electrodes. This two-path exploration also allowed us to de-risk the overall project and not rely on a single process for creating patterned electrodes. This project consisted of six high-level tasks aimed at transitioning the concept of acoustic focusing for battery electrodes from a technology readiness level (TRL) of 1 to 3 by project conclusion. Overall, we believe we have developed a practical and high-impact processing method that is chemistry agnostic and suitable for large-area fabrication of both 3D LIBs and other functional material systems where structuring on the scale of tens of microns has the potential to break conventional bulk material trade-offs in performance. In the case of batteries for electric vehicles, structuring 3D LIBs with our acoustic process breaks traditional energy and power trade-offs observed with conventional flat battery packs.

25 ENERGY STORAGE↗

Downhole nonlinear acoustics measurements in rock formations using dynamic acoustic elasticity and time reversal

Apparatus and methods for measurement of pore pressure in rock formations through an open, or cemented and/or cased, borehole are described. Such measurements are achieved using the Dynamic Acoustic Elasticity (DAE) method for characterizing nonlinear parameters by perturbing a selected rock formation volume with a High Amplitude, Low Frequency (HALF) acoustic strain wave, and probing this volume using a Low Amplitude, High Frequency (LAHF) acoustic wave. Time reversal techniques may be employed for focusing acoustic energy Into the formation in the vicinity of the pipe or open hole.

Goodman, Harvey Edwin↗

Time-reversed nonlinear acoustic downhole pore pressure measurements

Apparatus (10) and methods for measurement of pore pressure in rock formations through a metal borehole casing (32) after a well is cased and cemented, are described. Such measurements may be accomplished by using the Dynamic Acoustic Elasticity (DAE) method for characterizing nonlinear parameters by perturbing a selected rock formation region with a High Amplitude, Low Frequency (HALF) acoustic strain wave, and probing this region using a Low Amplitude, High Frequency (LAHF) acoustic wave (18), (22). Time reversal techniques (36) may be employed for focusing acoustic energy into the formation in the vicinity of the pipe or open hole. The change in wave speed of the probe pulses as the HALF induced strain wave oscillation propagates through the formation, as a function of the induced strain, may be used to determine the nonlinear elastic parameters α, β, δ, and A of the pore pressure, from which the pore pressure may be determined in the region of the HALF wave.

Goodman, Harvey E.↗

Using time reversal with long duration broadband noise signals to achieve high amplitude and a desired spectrum at a target location

Time Reversal (TR) is a signal processing technique that can be used to focus acoustic waves to a specific location in space, with most applications aiming to create an impulsive focus. Here, this study instead aims to focus long-duration noise signals using TR. This paper seeks to generate higher amplitude noise at a desired location over an existing method of broadcasting equalized noise. Additionally, this paper explores various characteristics associated with focusing long duration noise using TR. The dependence of the focal amplitude on the duration of the focused signal is explored as well as the implications of using multiple sources when focusing noise. The focal amplitude decreases with longer duration and then levels off when the duration exceeds a few seconds. Coherent addition of focused noise is observed if all loudspeakers have coherent noise signals convolved with their reversed impulse responses. Lastly, focusing noise with a desired spectrum is explored.

42 ENGINEERING↗

Arctic Ocean Hydroacoustics

As the Arctic warms and loses its perennial ice cover, it is becoming more attractive for a variety of human uses. Hydroacoustic monitoring of this activity will grow in importance over the coming years and decades. Changes to the physical environment affect acoustic propagation and noise, with ramifications for our ability to detect and locate events and activities of interest. In this report, we use two long-term data sets from the Beaufort Sea, western Arctic Ocean, to determine how acoustic propagation conditions and seismic source detections are impacted by the changing environment: 1) oceanographic observations from ice-tethered profilers, and 2) passive acoustic recordings from a hydrophone. We find that changes to Beaufort Sea thermohaline stratification is stabilizing a subsurface duct, leading to more focused acoustic energy arrivals. Detections of catalogued submarine earthquakes show geographic differences in signal strength between seismic and acoustic waves. Signal strength increases with earthquake magnitude, but relationships to other source and path factors are less clear. Ambient noise also has clear seasonal patterns in the Arctic, with relatively low noise in the spring, higher noise near 1 Hz in summer, and higher noise near 10 Hz in winter. Climate change is expected to modify these seasonal noise patterns, impacting event detection. Future work will further investigate the mechanisms of ice effects on sound and couple acoustic modeling to an Earth System Model.