Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acoustic radiation pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ultrasonic analyte concentration and application in flow cytometry

The present invention includes an apparatus and corresponding method for concentrating analytes within a fluid flowing through a tube using acoustic radiation pressure. The apparatus includes a function generator that outputs a radio frequency electrical signal to a transducer that transforms the radio frequency electric signal to an acoustic signal and couples the acoustic signal to the tube. The acoustic signal is converted within the tube to acoustic pressure that concentrates the analytes within the fluid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Empirical Acoustic Source Model for Chemical Explosions in Air

Chemical explosions generate pressure disturbances in air that radiate as nonlinear shock waves near the source and transition into acoustic waves with distance. Because low-frequency acoustic waves generally travel large distances without significant loss of energy, they are often used for explosion monitoring and yield estimation. However, quantitative relationships between acoustic energy and explosion yields are required for accurate yield estimation. Here, we develop an empirical acoustic source model for chemical explosions from experimental data. The empirical model returns the acoustic pressure waveform for the detonation of 1 kg of trinitrotoluene, which is conventionally used to represent the explosive release of 4.184 MJ of explosion energy. The full-waveform model can be used to predict acoustic signals for an arbitrary yield of a high-explosive detonation based on the standard scaling law and to estimate acoustic energies in a specific frequency range. We evaluate the accuracy of the acoustic source model independently by estimating the yield of other explosive events that are not included in the model development. Finally, statistical characteristics of the model and their implications for the uncertainty quantification of estimated yields are discussed.

58 GEOSCIENCES↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Applied Acoustics Lab Overview [Slides]

The lab of applied acoustics described focuses on development of instrumentation, methods and sensors with a focus on difficult and challenging conditions (high pressure, high temperature, corrosive media, radiation, etc.).

42 ENGINEERING↗

Aerodynamic-whistles-based ultrasonic tone generators for bat deterrence

Novel ultrasonic bat deterrents based on aerodynamic whistles are proposed and investigated experimentally and numerically for their ability to generate ultrasound. The baseline deterrent, a single-whistle design inspired by Beeken [“Fluid ultrasonic generator,” U.S. patent 3,432,804 (1969)], is examined first. It consists of two resonating cavities/chambers. The whistle is “powered” by a regulated high-pressure air supply, and the performance of the whistle is examined for a range of supply pressures. Far-field acoustic measurements in the 20 Hz–50 kHz frequency range are made in an anechoic chamber. The noise measurements are supplemented with two- and three-dimensional unsteady Reynolds-averaged Navier–Stokes (uRANS) simulations to investigate the mechanisms of ultrasound generation. The Ffowcs Williams–Hawkings acoustic analogy is used with the three-dimensional uRANS results to predict the far-field radiation. The far-field acoustic predictions are in good agreement with the measurements in the anechoic chamber. The peak frequency (fundamental) of the radiated ultrasound of the baseline deterrent is approximately 23 kHz. Harmonics and a sub-harmonic of the fundamental tone are also observed. The numerical simulations show that the two resonating chambers of the baseline deterrent operate out-of-phase and Helmholtz resonance determines the whistling frequency over the range of supply air pressure considered. A six-whistle deterrent targeting a broad spectral coverage in the 20–50 kHz frequency range is designed, fabricated, and tested in the anechoic chamber. Each whistle in the deterrent is obtained by geometrically scaling the baseline whistle. Measurements show that the six-whistle ultrasound deterrent generates ultrasound with six dominant peaks in the designed frequency range when the supply air pressure exceeds 5 psig. The proposed ultrasound devices can be used for a variety of purposes including bat deterrence at wind turbines.

42 ENGINEERING↗

Metamorphism-facilitated faulting in deforming orthopyroxene: Implications for global intermediate-depth seismicity

Significance The exothermic metamorphic reaction in orthopyroxene (Opx), a major component of oceanic lithospheric mantle, is shown to trigger brittle failure in laboratory deformation experiments under conditions where garnet exsolution takes place. The reaction product is an extremely fine-grained material, forming narrow reaction zones that are mechanically weak, thereby facilitating macroscopic faulting. Oceanic subduction zones are characterized by two separate bands of seismicity, known as the double seismic zone. The upper band of seismicity, located in the oceanic crust, is well explained by dehydration-induced mechanical instability. Our newly discovered metamorphism-induced mechanical instability provides an alternative physical mechanism for earthquakes in the lower band of seismicity (located in the oceanic lithospheric mantle), with no requirement of hydration/dehydration processes.

58 GEOSCIENCES↗

Vessel Rupture Thresholds for Vessel–Bubble Interactions Using an Earthworm Vasculature Model

Intravenous microbubble oscillation in the presence of ultrasound has the potential to yield a wide range of therapeutic benefits. However, the likelihood of vessel damage caused by mechanical effects has not been quantified as a function of the numerous important parameters in therapeutic ultrasound procedures. In this study, we examined the effects of microbubbles injected into the vasculature of the earthworm. It was found that the elastic properties of earthworm blood vessels are similar to those of arteries in older humans, and that earthworms are well suited to the large number of experiments necessary to investigate safety of procedures involving microbubble oscillation in sonicated vessels. Microbubbles were infused into earthworm vessels, and the rupture time during sonication was recorded as a function of ultrasound frequency, pulse repetition frequency and acoustic pressure. A modified mechanical index (MMI) was defined that successfully captured the trends in rupture probability and rupture time for the different parameter values, creating a database of vessel rupture thresholds. In the absence of bubbles, the product of MMI squared and rupture time was approximately constant, indicating a possible radiation-force effect. Here, the MMI was an effective correlating parameter in the presence of bubbles, though the mathematical dependence is not yet apparent. The results of the study are expected to be valuable in designing more refined studies in vertebrate models, as well as informing computational models.

59 BASIC BIOLOGICAL SCIENCES↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

Sensitivity of thermodynamic profiles retrieved from ground-based microwave and infrared observations to additional input data from active remote sensing instruments and numerical weather prediction models

Accurate and continuous estimates of the thermodynamic structure of the lower atmosphere are highly beneficial to meteorological process understanding and its applications, such as weather forecasting. In this study, the Tropospheric Remotely Observed Profiling via Optimal Estimation (TROPoe) physical retrieval is used to retrieve temperature and humidity profiles from various combinations of input data collected by passive and active remote sensing instruments, in situ surface platforms, and numerical weather prediction models. Among the employed instruments are microwave radiometers (MWRs), infrared spectrometers (IRSs), radio acoustic sounding systems (RASSs), ceilometers, and surface sensors. TROPoe uses brightness temperatures and/or radiances from MWRs and IRSs, as well as other observational inputs (virtual temperature from the RASS, cloud-base height from the ceilometer, pressure, temperature, and humidity from the surface sensors) in a physical iterative retrieval approach. This starts from a climatologically reasonable profile of temperature and water vapor, with the radiative transfer model iteratively adjusting the assumed temperature and humidity profiles until the derived brightness temperatures and radiances match those observed by the MWR and/or IRS instruments within a specified uncertainty, as well as within the uncertainties of the other observations, if used as input. In this study, due to the uniqueness of the dataset that includes all the above-mentioned sensors, TROPoe is tested with different observational input combinations, some of which also include information higher than 4 km above ground level (a.g.l.) from the operational Rapid Refresh numerical weather prediction model. These temperature and humidity retrievals are assessed against independent collocated radiosonde profiles under non-cloudy conditions to assess the sensitivity of the TROPoe retrievals to different input combinations.

54 ENVIRONMENTAL SCIENCES↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microphysically modified magnetosonic modes in collisionless, high-β plasmas

With the support of hybrid-kinetic simulations and analytic theory, we describe the nonlinear behaviour of long-wavelength non-propagating (NP) modes and fast magnetosonic waves in high-β collisionless plasmas, with particular attention to their excitation of and reaction to kinetic micro-instabilities. The perpendicularly pressure balanced polarization of NP modes produces an excess of perpendicular pressure over parallel pressure in regions where the plasma β is increased. For mode amplitudes |δB/B 0 |≳0.3, this excess excites the mirror instability. Particle scattering off these micro-scale mirrors frustrates the nonlinear saturation of transit-time damping, ensuring that large-amplitude NP modes continue their decay to small amplitudes. At asymptotically large wavelengths, we predict that the mirror-induced scattering will be large enough to interrupt transit-time damping entirely, isotropizing the pressure perturbations and morphing the collisionless NP mode into the magnetohydrodynamic (MHD) entropy mode. In fast waves, a fluctuating pressure anisotropy drives both mirror and firehose instabilities when the wave amplitude satisfies |δB/B 0 |≳2β -1 . The induced particle scattering leads to delayed shock formation and MHD-like wave dynamics. Taken alongside prior work on self-interrupting Alfvén waves and self-sustaining ion-acoustic waves, our results establish a foundation for new theories of electromagnetic turbulence in low-collisionality, high-β plasmas such as the intracluster medium, radiatively inefficient accretion flows and the near-Earth solar wind.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TEAMER - Acoustic Particle Velocity Measurements - CRADA 601 (Abstract)

With relatively few deployments of tidal turbines, the extent and effect of underwater sounds generated from these turbines is not well understood. The University of Washington (UW) is deploying a cross-flow turbine system, the Turbine Lander, in the entrance channel to Sequim Bay. The deployment of this system provides an opportunity to understand the noise radiated by the turbine and its sources. There are three hypothesized sound sources associated with operation of the turbine: 1) a continuous tone associated with energized power electronics; 2) sound associated with the generator when the turbine is rotating; and 3) sound associated with the bearing pack that supports the rotor. PNNL is collaborating with UW and Integral Consulting Inc. (Integral) to simultaneously measure sound sources using three different devices. The NoiseSpotter®, an acoustic sensor system designed by Integral, measures acoustic pressure and a three-dimensional particle velocity vector. The NoiseSpotter, along with a commercial-off-the-shelf acoustic particle motion and pressure sensor (M20-105, Geospectrum Technologies Inc.) owned by PNNL will be deployed on the seabed approximately 50-100 m from the Turbine Lander. UW will concurrently deploy Drifting Acoustic Instrumentation SYstems (DAISYs) to characterize acoustic pressure near the Turbine Lander and localize sounds using a Time Delay of Arrival (TDOA) algorithm. Integral, UW, and PNNL will collaborate on data analysis and interpretation, with the intention of jointly authoring an archival paper on the results. The noise generated from the Turbine Lander is not expected to be significant, yet this experiment will help to evaluate the efficacy of combining technologies to characterize noise and provide insights for approaches to consider for future turbine deployments at other locations.

16 TIDAL AND WAVE POWER↗

Environmental cell for in situ X-ray synchrotron micro-CT imaging with simultaneous acoustic measurements

Synchrotron radiation provides the necessary spatial and temporal resolution for non-invasive operando studies of dynamic processes under complex environmental conditions. Here a new environmental cell for simultaneous in situ dynamic X-ray imaging and measuring acoustic properties of geological samples is presented. The primary purpose of this cell is to study gas-hydrate formation in porous geo-materials and its influence on their acoustic properties. The cell is designed for cylindrical samples of 9 mm in diameter, confining and pore pressures up to 12 MPa, and temperatures from –20°C to room temperature. The cell is portable and can be easily assembled and operated at different X-ray sources. This cell enables a wide range of experiments studying physical/chemical processes in the Earth subsurface that change the mechanical properties of rocks (geochemical reactions, phase transitions, etc.).

47 OTHER INSTRUMENTATION↗

Experimental investigation of unsteady flow dynamics in therminol-66 using edge tone-induced oscillations

Recent research has demonstrated that flow oscillations induced by a wedge positioned opposite the jet outlet in edge tones can be effectively utilized for flow measurement purposes. This highlights the necessity for developing advanced instrumentation capable of precise flow measurements in experimental setups exposed to radiation and in challenging fluids such as molten salts. Here, this study contributes to the existing body of knowledge by conducting experiments using Therminol-66, an effective surrogate for FLiBe under appropriate temperature conditions for nuclear applications, across a broad range of Reynolds numbers from 17,700 to 555,000. Experiments were conducted with Therminol-66 at approximately 368.8 K under atmospheric pressure, with varying flow rates. A reliable correlation was established between the generated frequencies, corresponding flow rates, and device geometry parameters. The data were subjected to non-dimensional analysis to reveal the interrelationships among flow rate, fluid properties, device geometry, and their impact on the acoustic tones produced by the edge tone device. These findings contribute to the development of precise flow measurement instrumentation for use in challenging environments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock wave formation in the thermosphere by an earthgrazing fireball: Empirical evidence for volatile-enhanced hydrodynamic shielding

Hydrodynamic shielding is a theoretically well-established but observationally elusive and experimentally difficult-to-replicate phenomenon with implications that extend far beyond meteor physics. Rare earthgrazing meteoroids with infrasound signatures that penetrate to the ground can be used to probe hydrodynamic shielding that leads to strong shock formation at high altitude. Here, we report the first coordinated optical and multi-station infrasound observations of a centimeter-scale earthgrazing fireball that generated sustained cylindrical line shock at thermospheric altitudes near 92 km. The event was recorded by numerous optical stations and three infrasound arrays, allowing trajectory reconstruction, ablation behavior, acoustic source localization, and shock characteristics. Optical observations indicate early mechanical erosion and ablation/evaporation at exceptionally low dynamic pressure, consistent with a cometary or a porous, volatile-bearing CM chondritic object. Independent infrasound detections localize shock generation to multiple points along a 164 km trajectory segment near perigee. Weak-shock modeling yields a consistent blast radius of ∼30 m, implying an acoustic-equivalent source size far exceeding the physical dimensions of the ∼45 g nucleus. We demonstrate that classical gas dynamics and ablation-driven hydrodynamic shielding alone cannot account for these observations under ambient thermospheric conditions. We show that volatile release provides the additional flow-field density enhancement required to amplify hydrodynamic shielding, reduce the effective local Knudsen number, and sustain a shock envelope capable of radiating detectable infrasound. Furthermore, these results demonstrate that small, volatile-rich meteoroids can transiently establish continuum-like flow in rarefied environments.

Astrometry↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗