Design and analysis of actively-cooled, edge-transport diagnostic for long-pulsed operation in WEST

Next step fusion devices that will operate in steady-state will require complex plasma-facing components (PFCs) that can survive the harsh environment over long timescales not common in current devices. This will require robust plasma facing surfaces that are integrated with active cooling systems. In a collaboration between CEA and ORNL, a plasma-interacting diagnostic is being designed for the W Environment in Steady-state Tokamak (WEST) in Cadarache, France which requires plasma-facing protection like those needed for steady-state PFCs. This integrated diagnostic studies edge transport and impurity migration within WEST, and is planned to include imbedded temperature Langmuir probe sensors, as well as removeable sample slots for ex-situ surface analysis of plasma-material interactions. The entire assembly is expected to move into the plasma edge for periods up to 1000 s having an energy removeable capability of ∼6 kW and seeing a peak heat flux of more than 7 MW/m2. The assembly compliments WEST high fluence campaigns that plan for multiple 1000 s pulses. Within these specifications, the assembly will require a refractory metal plasma facing surface and integral cooling in order to function within the limited space allotted for such diagnostics. Because of the limited space and linear actuator needs, additive manufacturing of the high heat flux working end of the assembly is being considered which could allow for precision cooling-channels and lighter weight designs. Conceptual design along with simulation and analysis results will be presented for this complex diagnostic with novel PFCs.

Lumsdaine, Arnold↗

Actively cooled optical substrates for high average power reflective or diffractive optic

Integrated active cooling of high-power reflective or diffractive optics uses substrates manufactured from low-expansion ceramics to flow coolant between the back surface of the substrate and chambers behind but adjacent a reflective front surface, in a direction transverse to the front surface, to thereby achieve much greater average power handling than known cooling techniques.

Power, Erik P.↗

Infrared triggered dwell and active cooling thermal control effects on microstructural uniformity in DED

Directed Energy Deposition (DED) offers rapid large scale fabrication, but difficulty in delivering consistent microstructures and properties hinders the use of DED fabricated components in safety or performance critical applications. Variability stems from the complex thermal cycles generated by the toolpath used to print the required geometry. Several practical methods have become established in DED to regulate overheating, such as active cooling of the baseplate structure or the use of an infrared camera to inject interlayer pauses to ensure the top layer of the component cools to a set temperature, which have been shown to affect microstructure. However, no critical assessment has been performed as to how effective these controls are in promoting microstructural uniformity in the context of complex layer timing commonly generated by non-prismatic geometries. Here we show how controls influence the thermal field, phase transformations, and dynamic annealing of a low-temperature transformation steel using infrared imaging and operando neutron diffraction. Counterintuitively, common thermal homogenization process controls can reduce microstructural uniformity because these approaches stabilize peak temperature while overlooking temperatures near the solid-state phase transformation fronts. Instead, the cyclic reheating induces spatially-variant dynamically annealed regions which can be modulated via control parameters. We show that these controls have spatially linked effects centimeters away from the active weld, which implies that microstructure control must co-optimize thermal input across many subsequent layers. In conclusion, our results demonstrate the pressing need for higher order controls that integrate predictive elements of simulation data to stabilize printed properties for future qualification of DED components.

Directed energy deposition↗

Cosmic-ray cooling in active galactic nuclei as a new probe of inelastic dark matter

We present a novel way to probe inelastic dark matter using cosmic-ray (CR) cooling in active galactic nuclei (AGNs). Dark matter (DM) in the vicinity of supermassive black holes may scatter off CRs, resulting in the rapid cooling of CRs for sufficiently large cross sections. This in turn can alter the high-energy neutrino and gamma-ray fluxes detected from these sources. We show that AGN cooling bounds obtained through the multimessenger data of NGC 1068 and TXS 0506 + 056 allows us to reach unprecedently large mass splittings for inelastic DM (≳ TeV), orders of magnitude larger than those probed by direct detection experiments and DM capture in neutron stars. Furthermore, we demonstrate that cooling bounds from AGNs can probe thermal light DM with small mass splittings. This provides novel and complementary constraints in parts of a parameter space accessible solely by colliders and beam-dump experiments.

astronomical black holes↗

High-Temperature Wireless Sensor Platform Powered by Energy Scavenging

This paper reports on the development of key components required for a self-powered oscillator unit designed to wirelessly transmit its signal under full insertion in high-temperature (HT) harsh-environments (HE), such as those present in power plants and industrial settings (metallurgic, oil extraction, molding, and aerospace). The oscillator employed a silicon carbide (SiC) power transistor and HT passive components on a screen-printed alumina circuit board capable of operation beyond 300 °C. The HT oscillator circuit was powered solely by in-situ energy scavenging thermoelectric generator (TEG) modules using passive cooling, eliminating the need for an external power supply or active cooling. In addition, a silicon-based external booster circuit was used to achieve the required TEG voltage regulation to test the TEG-powered HT oscillator circuit. The TEG-powered oscillator circuit was tested inside a non-metallic furnace from room temperature to over 300 °C for transmission of a wireless signal, which was detected outside the furnace at 11 ft (3.4 m). Such a wireless transmitting system powered only by in-situ TEGs, with no requirement for external power or active cooling, is very attractive for flexible, mobile stand-alone control and sensor units targeted for operation in HT HE conditions found in power plants and industrial settings.

20 FOSSIL-FUELED POWER PLANTS↗

WEST full tungsten operation with an ITER grade divertor

The mission of WEST (tungsten-W Environment in Steady-state Tokamak) is to explore long pulse operation in a full tungsten (W) environment for preparing next-step fusion devices (ITER and DEMO) with a focus on testing the ITER actively cooled W divertor in tokamak conditions. Following the successful completion of phase 1 (2016-2021), phase 2 started in December 2022 with the lower divertor made entirely of actively cooled ITER-grade tungsten mono-blocks. A boronization prior the first plasma attempt allowed for a smooth startup with the new divertor. Despite the reduced operating window due to tungsten, rapid progress has been made in long pulse operation, resulting in discharges with a pulse length of 100 s and an injected energy of around 300 MJ per discharge. Plasma startup studies were carried out with equatorial boron nitride limiters to compare them with tungsten limiters, while Ion Cyclotron Resonance Heating assisted startup was attempted. High fluence operation in attached regime, which was the main thrust of the first campaigns, already showed the progressive build up of deposits and appearance of dust, impacting the plasma operation as the plasma fluence increased. In total, the cumulated injected energy during the first campaigns reached 43 GJ and the cumulated plasma time exceeded 5 h. Demonstration of controlled X-Point Radiator regime is also reported, opening a promising route for investigating plasma exhaust and plasma-wall interaction issues in more detached regime. This paper summarises the lessons learned from the manufacturing and the first operation of the ITER-grade divertor, describing the progress achieved in optimising operation in a full W environment with a focus on long pulse operation and plasma wall interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conjugate Multimode Heat Transfer Analysis of Cryogenic EXLO Manipulation

Abstract In this study, a conjugate radiation/conduction multimode heat transfer analysis of cryogenic focused ion beam (FIB) milling steps necessary for producing ex situ lift out specimens under cryogenic conditions (cryo-EXLO) is performed. Using finite volume for transient heat conduction and enclosure theory for radiation heat transfer, the analysis shows that as long as the specimen is attached or touching the FIB side wall trenches, the specimen will remain vitreous indefinitely, while actively cooled at liquid nitrogen (LN2) temperatures. To simulate the time needed to perform a transfer step to move the bulk sample containing the FIB-thinned specimen from the cryo-FIB to the cryo-EXLO cryostat, the LN2 temperature active cooling is turned off after steady-state conditions are reached and the specimen is monitored over time until the critical devitrification temperature is reached. Under these conditions, the sample will remain vitreous for >3 min, which is more than enough time needed to perform the cryo-transfer step from the FIB to the cryostat, which takes only ∼10 s. Cryo-transmission electron microscopy images of a manipulated cryo-EXLO yeast specimen prepared with cryo-FIB corroborates the heat transfer analysis.

Materials Science↗

Transmissive concentrated photovoltaic module with cooling system

A spectrum splitting, transmissive concentrating photovoltaic (tCPV) module is proposed and designed for a hybrid photovoltaic-solar thermal (PV/T) system. The system may be able to fully utilize the full spectrum of incoming sunlight. By utilizing III-V triple junction solar cells with bandgaps of approximately 2.1 eV, 1.7 eV, and 1.4 eV in the module, ultraviolet (UV) and visible light (in-band light) are absorbed and converted to electricity, while infrared (IR) light (out-of-band light) passes through and is captured by a solar thermal receiver and stored as heat. The stored heat energy may be dispatched as electricity or process heat as needed. The tCPV module may have an overall power conversion efficiency exceeding 43.5% for above bandgap (in-band) light under a standard AM1.5D solar spectrum with an average concentration ratio of 400 suns. Passive and/or active cooling methods may be used to keep cells below 110° C. while transmitting >75% of out-of-band light to the thermal receiver, which may attain thermal energy capture at temperatures as high as 500° C. or more. A transparent active cooling system may improve the CPV module efficiency by about 1% (absolute) relative to a passive cooling system by reducing the maximum cell working temperature by about 16° C.

Escarra, Matthew David↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Effect of Cathode Cooling in Three-Dimensional Simulations of an Atmospheric Pressure Glow Discharge

The Atmospheric Pressure Glow Discharge (APGD) is a relatively simple and versatile plasma source used in a wide range of applications. Active cooling of the cathode can effectively mitigate instabilities, leading to glow-to-arc transitions. This study investigates the effect of varying the degree of cathode cooling in APGD with a planar cathode in helium. The plasma flow model incorporates mass conservation, chemical species transport, momentum conservation, conservation of thermal energy of heavy species and of electrons, and electrostatics. The model is applied to time-dependent simulations through a three-dimensional computational domain describing the whole discharge, without geometric symmetry or steady-state assumptions. Simulations of an experimentally characterized APGD explore the effects of electric current and cathode cooling—ranging from thermally insulated to extreme convective cooling. Results show the formation of an annular region with high electric field over the cathode surface under conditions of high current and low cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modular Coaxial Power Converter for High-Density Integration into Medium-Voltage Cables

This work proposes to combine the functionality benefits of power electronics with the power density benefits of medium-voltage cables to create a streamlined, high-density power electronics solution that seamlessly integrates with medium-voltage cables. Located at the ends of a medium- or high-voltage line, the proposed converter uses a cascade of coaxial power conversion cells to gradually step down the voltage, and excels in high step-down applications. By mimicking the coaxial geometry of medium-voltage cables, the converter preserves the axisymmetric electric field of the cable which, when combined with a solid insulating dielectric, provides a voltage scaling advantage over conventional planar and PCB-based converter solutions. Similar to medium voltage cables, the converter is fully passively cooled. A passive cooling strategy allows for combined installation with existing medium voltage cable systems without the added cost, maintenance needs, infrastructure, and reliability concerns associated with active cooling systems. The scalability of the modular structure in combination with the integration benefits provide a flexible power electronics system that can adapt to the evolving demands of the grid.

coaxial power conversion cells↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fluidized Bed Gasification For Conversion of Biomass and Waste Materials to Renewable Hydrogen

This project was undertaken in order to study the potential for hydrogen production, at low cost, from mixtures of biomass and municipal solid waste (MSW). This approach allows for the production of hydrogen with a very low fossil carbon burden, while taking advantage of tipping fees (associated with MSW) to improved process economics. The team sourced three primary feedstocks (wood, MSW, and waste plastics) and characterized them comprehensively using established techniques with a long track record in the field of gasification. All three primary feedstocks were highly reactive and lost most of their mass during initial devolatilization. The production of tars, including heavy tars, was quite high, and was most problematic in the case of the MSW and Waste Plastics feedstocks. Little practical difference was identified between the MSW and Waste Plastics materials, and the addition of bed-forming materials (dolomite and brown alumina) to the feedstocks was found to reduce production of tars during devolatilization under thermogravimetric analysis and/or Fischer Assay conditions. A series of four tests in a lab-scale bubbling-fluidized-bed gasifier, at 50 psig of pressure and about 825 C, confirmed these findings. Pellet feedstocks, broken into fragments, were used for these tests, and pellets comprised of 50% MSW and 50% biomass were found to be the best option in terms of fossil carbon burden, economic potential, and gasification characteristics. Tests were then undertaken in a pilot-scale gasifier facility based on the GTI U-Gas fluidized-bed gasification technology. The feedstock handling train of the 20 TPD U-Gas pilot-scale gasifier located in Des Plaines, IL, was operated under simulated gasification conditions, and the 50/50 pellets were found to be very robust and unproblematic. An improved design for the forward end of the feedstock injection screw of the gasifier was developed and installed. The design approach was based on improved passive cooling of the front-most shroud at the end of the screw, since this approach was found in comprehensive modeling studies to be more than sufficient to accomplish the project objectives associated with this phase of the work, while also avoiding thermal gradients that could have caused heat-stress-induced damage to the refractory around the feedstock inlet if an active cooling approach had been applied. Careful technoeconomic analysis (TEA) of two possible 1000 TPD facilities was carried out. The TEA of conversion of MSW with corn stover in one case, and MSW with woody feedstock in the other case, showed that both had the potential to provide hydrogen at about $1/kg (minimum selling price, 2018 dollar basis). Of the two TEA cases, the one that was based on the conversion of wood in the southeastern USA was found to have slightly better economic potential. The other TEA case was based on a real location in Nebraska and called for corn stover feedstock conversion along with MSW. An underserved communities outreach program plan was developed in cooperation with personnel from the Nebraska Public Power District.

08 HYDROGEN↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microstructure Alignment Effects from Engineered Cooling during Additive Manufacturing of Alnico Magnets from Prealloyed Powder

Alnico is a rare-earth free; permanent magnet (PM) which maintains its saturation magnetization while at temperatures up to 550°C but lacks the coercivity and energy product needed for a wide range of demanding applications. With an optimal set of processing and manufacturing techniques, Alnico could replace Dy-free Nd-Fe-B magnets in certain applications if the microstructure is textured in a $\langle$001$\rangle$ direction. Additive manufacturing (AM) of near-net-shape magnets may provide such texture. To investigate the possibility, directed-energy deposition (DED) in conjunction with an actively cooled substrate was used to build samples with a compositionally modified, gas-atomized, Alnico 8 alloy. The resulting samples were solutionized and quenched, followed by magnetic annealing and a heat treatment. Magnetic properties and microstructures are compared to previous work.

36 MATERIALS SCIENCE↗