Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active magnetic regeneration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers

A design of an Active Magnetic Regenerative Refrigeration (AMRR) system has been developed for space applications. It uses an innovative 3He cryogenic circulator to provide continuous remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. A critical component technology for this cooling system is a highly efficient active magnetic regenerator, which is a regenerative heat exchanger with its matrix material made of magnetic refrigerant gadolinium gallium garnet (GGG). Creare Inc. is developing a microchannel GGG regenerator with an anisotropic structured bed for high system thermal efficiency. The regenerator core consists of a stack of thin, single-crystal GGG disks alternating with thin polymer insulating layers. The insulating layers help minimize the axial conduction heat leak, since GGG has a very high thermal conductivity in the regenerator s operating temperature range. The GGG disks contain micro channels with width near 100 micrometers, which enhance the heat transfer between the circulating flow and the refrigerant bed. The unique flow configuration of the GGG plates ensures a uniform flow distribution across the plates. The main fabrication challenges for the regenerator are the machining of high-aspect-ratio microchannels in fragile, single-crystal GGG disks and fabrication and assembly of the GGG insulation layers. Feasibility demonstrations to date include use of an ultrashort- pulse laser to machine microchannels without producing unacceptable microcracking or deposition of recast material, as shown in the figure, and attachment of a thin insulation layer to a GGG disk without obstructing the flow paths. At the time of this reporting, efforts were focused on improving the laser machining process to increase machining speed and further reduce microcracking.

Chen, Weibo↗

Balancing performance of active magnetic regenerators: a comprehensive experimental study of aspect ratio, particle size, and operating conditions

Abstract Effective and, at the same time, efficient active magnetic regenerator (AMR) performance requires balanced geometry and operating conditions. Here the influence of regenerator shape, magnetocaloric material size, operating frequency, and utilization on the performance of gadolinium packed-particle bed AMRs is demonstrated experimentally. Various metrics are applied to assess effectiveness and efficiency. Observed temperature spans and cooling powers across a wide range of operating conditions are used to evaluate system performance and estimate exergetic cooling power and exergetic power quotient. A new metric combining exergetic cooling power and pump power provides an estimate of the maximum achievable second law efficiency. Five regenerator geometries with equal volumes and the aspect ratio from 1.0 to 3.8, and four different ranges of Gd spherical particles between 182 and 354 µ m, are investigated. Improvements in system performance are demonstrated by a boost in specific cooling power of gadolinium from 0.85 to 1.16 W g −1 and maximum temperature span from 8.9 to 15.1 K. The optimum exergetic cooling power is observed for 1.37 utilization and 3 Hz operating frequency, exergetic power quotient exhibits a maximum at the same utilization but at 2 Hz frequency, while the highest efficiency is recorded at 1 Hz and utilization of 0.5, demonstrating that multiple performance metrics must be balanced to achieve regenerator design meeting all performance targets.

42 ENGINEERING↗

The theory of an active magnetic regenerative refrigerator

The adiabatic temperature change with field which is limited to about 2 K/Tesla for ferromagnets near their Curie temperatures by the change of magnetization with temperature and the lattice heat capacity is discussed. Practical magnetic refrigerators operate on a regenerative cycle such as the Brayton cycle. This cycle can be executed through the use of an active magnetic regenerator, i.e., a regenerator composed of magnetic material that is cycled in an out of a magnetic field with appropriate fluid flows. The theory of these devices is predicted by solving the partial differential equations that describe fluid and the magnetic solid. The active magnetic regenerator is described along with the method of calculation. Temperature profiles for a normal regenerator and a magnetic regenerative refrigerator are shown.

Barclay, J. A.↗

Compatibility of LaFe13−x−yMnxSiyH1.6 and Eutectic Liquid GaInSn Alloy

The heat transfer rate of magnetocaloric regenerators is a topic of extensive research and the cyclability of these regenerators is critical to the operation of systems with a high coefficient of performance (e.g., potentially >22, significantly higher than typical vapor compression cooling technologies). To enable a high operating frequency that will result in a high specific cooling power, the heat transfer fluid should have high thermal conductivity and lower specific heat, i.e., higher thermal diffusivity. Eutectic metal alloys possess these qualities, such as gallium–indium–tin (Galinstan), whose thermal diffusivity has been found to be approximately an order of magnitude higher than water. For this study, the effects of eutectic liquid Galinstan exposure on the phase stability of LaFe13−x−yMnxSiyH1.6 magnetocaloric powders in an active magnetic regenerator device were investigated. The powders were characterized before and after exposure to Galinstan using X-ray diffraction, in which the phases were determined using the Rietveld refinement technique and X-ray fluorescence. It was found that after Galinstan exposure, hydrogen containing phases were present in the powder, suggesting that the hydrogen was lost from the magnetocaloric phase. The magnetocaloric phase degradation indicates that the powder was incompatible with the Galinstan metal in an environment with moisture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable and compact magnetocaloric heat pump technology

Magnetocaloric heat pumping (MCHP) promises to be more efficient than traditional vapor compression while also eliminating the deleterious effects of gaseous refrigerants. While MCHP devices have shown the temperature spans and efficiencies needed for different heating and cooling applications, they struggle to become commercially viable due to their large size and mass, and resultant high cost. This paper evaluates a baseline MCHP device and explores methods to boost its system power density (SPD). The key components of the baseline system are the gadolinium packed-particle bed active magnetic regenerator (AMR) and a magnetic source composed of permanent magnets and high permeability magnetic steel. To enhance the SPD, the paper evaluates maximizing the AMR volume, opting for first-order magnetocaloric materials, optimizing the magnet and AMR geometry, and reducing the size of magnets and magnetic steel parts. At larger thermal powers, increasing the AMR diameter and the number of magnetic poles were evaluated. Using finite element models, solid models, and estimates of magnetocaloric material performance, thermal powers ranging from 37 W to 44 kW at a nominal 10 K temperature span were projected, and SPD was estimated to improve from 6 W/kg to 81 W/kg. Neglecting end effects, an upper limit of 114 W/g is estimated. Compared to SPD of off-the-shelf compressors with similar environment temperatures, MCHP power density using gadolinium is competitive up to roughly 200 W of cooling power. This is extended to 1 kW when using LaFeSi alloys and up to 3 kW in the limiting case. In conclusion, these results indicate that the performance and mass of MCHP can match that of compressors, which is a critical step toward cost-competitive magnetocaloric technology.

42 ENGINEERING↗

Using numerical methods to screen magnetocaloric materials in an active magnetic regenerative cycle

A 2-dimensional numerical model of a room temperature operating Active Magnetic Regenerator (AMR) that comprises of a regenerator, hot and cold heat exchangers, heat transfer fluid is developed. The regenerator is made of a magnetocaloric material (MCM) which heats up upon applying a magnetic field, H, and cools down when the field is removed; thus, making it the most essential part of an AMR. The model takes experimentally measured ΔT ad (H,T) and the C p (H,T) data as input and provides quantitative performance metrics of the magnetic cooling system, such as ΔT span and the cooling load, as output. With this model, it is possible to assess a wide range of MCMs in an AMR. 4 different MCMs were investigated using this model in terms of their ΔT span and the cooling loads—LaFe 10.96 Co 0.97 Si 1.07 , MnFeP (1-x) As (x) and AlFe 2 B 2 and Gd. During the screening of MCMs, all the important operating conditions of the device were fixed such as the fluid flow rate, ambient temperature, cycle duration, magnetic field strength. Our results indicate that Gd exhibits the maximum ΔT span with respectable cooling load, while AlFe 2 B 2 generates the lowest ΔT span . Even though LaFeCoSi compound did not perform as well as Gd, it could be the MCM choice for the realization of magnetic refrigeration on a global scale due to its much lower cost.

36 MATERIALS SCIENCE↗

NASA Tech Briefs, June 2013

Topics include: Cloud Absorption Radiometer Autonomous Navigation System - CANS, Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis, Discrete Data Qualification System and Method Comprising Noise Series Fault Detection, Simple Laser Communications Terminal for Downlink from Earth Orbit at Rates Exceeding 10 Gb/s, Application Program Interface for the Orion Aerodynamics Database, Hyperspectral Imager-Tracker, Web Application Software for Ground Operations Planning Database (GOPDb) Management, Software Defined Radio with Parallelized Software Architecture, Compact Radar Transceiver with Included Calibration, Software Defined Radio with Parallelized Software Architecture, Phase Change Material Thermal Power Generator, The Thermal Hogan - A Means of Surviving the Lunar Night, Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers, Nano-Ceramic Coated Plastics, Preparation of a Bimetal Using Mechanical Alloying for Environmental or Industrial Use, Phase Change Material for Temperature Control of Imager or Sounder on GOES Type Satellites in GEO, Dual-Compartment Inflatable Suitlock, Modular Connector Keying Concept, Genesis Ultrapure Water Megasonic Wafer Spin Cleaner, Piezoelectrically Initiated Pyrotechnic Igniter, Folding Elastic Thermal Surface - FETS, Multi-Pass Quadrupole Mass Analyzer, Lunar Sulfur Capture System, Environmental Qualification of a Single-Crystal Silicon Mirror for Spaceflight Use, Planar Superconducting Millimeter-Wave/Terahertz Channelizing Filter, Qualification of UHF Antenna for Extreme Martian Thermal Environments, Ensemble Eclipse: A Process for Prefab Development Environment for the Ensemble Project, ISS Live!, Space Operations Learning Center (SOLC) iPhone/iPad Application, Software to Compare NPP HDF5 Data Files, Planetary Data Systems (PDS) Imaging Node Atlas II, Automatic Calibration of an Airborne Imaging System to an Inertial Navigation Unit, Translating MAPGEN to ASPEN for MER, Support Routines for In Situ Image Processing, and Semi-Supervised Eigenbasis Novelty Detection.

Source record↗

Active magnetic regenerative cooling with smaller magnets

Magnetocaloric heat pumping near room temperature, a.k.a. magnetic cooling, relies on the active regenerator cycle to achieve functional temperature spans and realize economic and societal benefits promised by this emerging solid-state cooling technology. The cycle itself depends upon synchronizing oscillating flow of a heat transfer fluid through a solid porous active material matrix, or the refrigerant, with periods when the refrigerant is in the highest available (field-on) and in nearly zero (field-off) magnetic fields to accomplish heat transfer. With this in mind, in this work we analyze varying flow and magnetic field wave forms and the timing between when the fluid is pumped and when the magnetic field is turned on and off. We demonstrate that the volume and the cost of permanent magnet generating the field changes can be cut nearly in half with little to no effect on the device temperature span and cooling power normalized by the refrigerant mass.

36 MATERIALS SCIENCE↗

Highly Efficient Magnetocaloric Natural Gas Liquefaction (Final Report)

Over the twelve-month project the following achievements were accomplished: • Liquefication of methane as primary component of natural gas was accomplished with a magnetocaloric liquefier (MCL) prototype. This was the first time an MCL was used to liquefy methane. • Improved MCL designs were completed. • Cooling to 135 K from room temperature was achieved for the first time in a single MCL stage with dual, reciprocating four-layer regenerators. • Techno-economic analysis for a multi-stage 5 tonne/day magnetocaloric liquefier was completed. The detailed thermodynamic analysis of this MCL design showed a figure of merit (FOM) of 0.6 was achievable. This is a ~2x improvement over current state of the art. • Cost of an efficient 5 tonne/day LNG multi-stage liquefier was projected to be ~$\$$3.1 MM for the 5 tonne/day MCL with achievable design assumptions. • Market study of U.S. merchant LNG demand by energy sector was completed showing that at beginning of 2019, total use was ~2.5 million gallons/day primarily in three sectors that was filled by ~20 small companies in the merchant LNG supply business producing ~2.3 million gpd. These data exclude LNG produced at dedicated peak shaving and large export plants. • Business case for MCL technology based on LNG market study was completed showing the high FOM feature of MCL reduces cost of plant power, and lower capital cost reduces debt repayment and plant depreciation operating expenses. However, today’s demand for U.S. merchant LNG in most sectors is satisfied with conventional technology. Further, with today’s extremely low natural gas (NG) feedstock costs (e.g., ~$\$$1.8/MMBtu), the cost of fuel for NG gensets and for LNG feedstock is already very low. Therefore, possible new merchant LNG liquefier plant developers anticipating demand growth in the transportation, industrial, and electricity generation sectors do not obtain sufficient cost benefits to adopt new, commercially unproven MCL technology. • Other market factors such as remoteness from existing NG pipelines, or unfilled or unsatisfied applications such as boil-off gas re-liquefaction in LNG vessels, or policy factors such as some form of emissions-related fees may make lower capital costs and higher FOM of MCL technology attractive for new small-scale (~50 tonne/day) LNG plants. Two potentially attractive niche markets for MCL technology were identified: i) re-liquefaction of boil-off gas from large LNG transport vessels where severe transport conditions are problematic for conventional technology; and ii) providing LNG in distributed-scale plants that eliminate road transport costs to meet diverse, smaller-scale, distributed LNG bunkering fuel demands. By eliminating significant cryogenic tanker delivery costs and create an attractive cost-savings benefit with small-scale MCL plants.

03 NATURAL GAS↗

Photospheric magnetic fields

Knowledge on the nature of magnetic fields on the solar surface is reviewed. At least a large part of the magnetic flux in the solar surface is confined to small bundles of lines of force within which the field strength is of the order of 500 gauss. Magnetic fields are closely associated with all types of solar activity. Magnetic flux appears at the surface at the clearly defined birth or regeneration of activity of an active region. As the region ages, the magnetic flux migrates to form large-scale patterns and the polar fields. Some manifestations of the large-scale distribution are discussed.

Howard, R.↗

Lignin-Derived Magnetic Activated Carbons for Effective Methylene Blue Removal

Large-scale environmental remediation of polluted water requires an effective and recyclable adsorbent produced from an abundant, low-cost, and renewable feedstock via a simple processing procedure. In this work, we demonstrate that lignin-derived magnetic activated carbons (mACs) uniquely satisfy these five criteria for (i) high-performance adsorption, (ii) high regeneration efficiency, (iii) feedstock economic and environmental viability, (iv) single-step processing and (v) large-scale production. The mACs are synthesized via an efficient co-carbonization and activation with simultaneous impregnation of ferric sulfate. Here, the Langmuir model closely fits the adsorption of methylene blue (MB) by mACs within the temperature range of 298–323 K, where the adsorption capacity increases as temperature increases. This capacity increased from 55.0 mg g -1 to 220.2 mg g -1 with the presence of magnetic nanoparticles. In addition, the magnetite nanoparticles on the ACs surface significantly improve its recycling ability with the removal percentage above 95% after four cycles for 5:1 mAC.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Using Regenerated Combined FAU and MOR Zeolites as Catalysts during the Pyrolysis of Kraft Lignin

The SiO 2 /Al 2 O 3 mole ratio, pore size, and acid sites are the key parameters of zeolite’s activity in lignin pyrolysis. In this study, the comparison of individual Y and M zeolites, the combined ‘Y + M’ sample after regeneration, and their effect on lignin pyrolysis were studied in five cycles (regeneration and reuse). The results were explained using Brunauer, Emmet, and Teller (BET), micropore surface area (MSA), and total acid sites (TAS) analyses. In comparison with the individual Y or M zeolite sample, the consistent higher catalytic activities of the combined ‘Y + M’ sample in repeated cycles were observed. Pyrolysis heavy oils were characterized by nuclear magnetic resonance (NMR) spectroscopy and gel permeation chromatography (GPC). The NMR analyses revealed that with increased zeolite regeneration cycles, p-hydroxy phenyl and methoxyl groups increased. Decreases in guaiacyl phenolic hydroxyl were less for the combined ‘Y + M’ sample than the individual Y and M zeolites. Lower weight average (M w ) of heavy oil for the combined ‘Y + M’ sample indicated the enhanced cleavage of lignin structures in pyrolysis. These results support the higher catalytic activity of regenerated zeolites for the combined ‘Y + M’ sample compared with individual Y and M zeolites due to the improved MSA and TAS.

59 BASIC BIOLOGICAL SCIENCES↗

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Methane liquefaction with an active magnetic regenerative refrigerator

This manuscript reports liquefaction of methane using an active magnetic regenerative refrigerator (AMRR). The AMRR used to cool from 285 K to 135 K has two identical regenerators fabricated with adjacent layers of four ferromagnetic refrigerants, each with sequentially lower Curie temperatures and lesser masses from hot to cold temperatures. The dual multilayer regenerators were assembled in opposition with a single cold region between them. For this set of experiments equal mass of helium gas was pumped through all layers of the regenerators during the two flow steps of the four-step AMR cycle. After successfully reaching 135 K, a compact condensing coil-fin tube heat exchanger (HEX) with a small storage vessel was mounted in the cold region of the dual regenerator assembly to be cooled during the hot-to-cold helium flow from alternatively demagnetized regenerators. The cold HEX was used to cool and liquefy a process stream of methane gas supplied at 295 K and different pressures in different runs. Further, by measuring time to liquefy a known volume of methane at three different pressures, cooling powers of the AMRR as a function of temperature were determined. The resultant data were compared to those predicted by the AMRR performance model. Conclusions from these experiments and suggestions for future work are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evidence for magnetospheric effects on the sodium atmosphere of Mercury

Monochromatic images of Mercury at the sodium D2 emission line showed excess sodium emission in localized regions at high northern and southern latitudes and day-to-day global variations in the distribution of sodium emission. These phenomena support the suggestion that magnetospheric effects could be the cause. Sputtering of surface minerals could produce sodium vapor in polar regions during magnetic substorms, when magnetospheric ions directly impact the surface. Another important process may be the transport of sodium ions along magnetic field lines toward polar regions, where they impact directly on the surface of Mercury and are neutralized to regenerate neutral sodium atoms. Day-to-day variations in planetary sodium distributions could result from changing solar activity, which can change the magnetosphere in time scales of a few hours. Observations of the sodium exosphere may provide a tool for remote monitoring of the magnetosphere of Mercury.

Potter, A. E.↗

Compact and efficient elastocaloric heat pumps—Is there a path forward?

Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

42 ENGINEERING↗