At least 19 records

Comparison of CCM- and CRM-Based Boost Parallel Active Power Decoupler for PV Microinverter

Single-phase inverter or rectifier systems often make use of an active power decoupler (APD) to balance the mismatch between constant dc power and fluctuating ac power. This article deals with the comparison of continuous conduction mode (CCM) and critical conduction mode (CRM) operation-based design of a parallel boost-type APD for photovoltaic microinverter applications. From a design perspective, multiobjective analysis of efficiency, volume, and cost is explored within a decision space including planar inductors, gallium nitride based devices, film capacitors, switching frequency, and modulation (CCM vs. CRM). The theoretical study analyzes all possible design configurations within CCM and CRM and identifies Pareto-optimal designs, from which the selected CRM design can achieve reduced system volume and lower cost with the use of smaller inductor core, while operating with similar California Energy Commission efficiency drop as the selected CCM design. From a control perspective, a pulsewidth modulation based control strategy is proposed to implement closed-loop CRM modulation that does not rely on zero-crossing detection. Furthermore, closed-loop systems are designed for the optimal CCM and CRM realizations, and the final system characteristics are compared. Experimental results, obtained using two separate 40-V, 400-W hardware prototypes for CCM and CRM, are presented to verify the analyses.

42 ENGINEERING↗

A Grid-Forming Split-Phase Three-Leg Inverter with Unbalanced Loading and Active Power Decoupling

This paper presents a split-phase three-leg inverter that regulates 180-degree phase-shifted AC voltages to support residential house loads under unbalanced loading conditions and decouples double line frequency power pulsation by utilizing the third half-bridge switching leg. The active power decoupling function is added without extra active switching components. The control feasibility and effectiveness are verified through MATLAB Simulink simulation and controller hardware-in-the-loop test.

Kim, Namwon [ORNL] (ORCID:0000000200438489)↗

CCM vs. CRM Design Optimization of a Boost-derived Parallel Active Power Decoupler for Microinverter Applications

Single-phase inverter or rectifier systems often make use of an auxiliary active power decoupler (APD) to balance the mismatch between steady DC power and fluctuating AC power. This paper deals with efficiency and size optimization of a parallel boost-type APD circuit for PV microinverter applications. Specifically, design of an eGaNFET-based, 400 W APD circuit, employing planar inductor and operating in either continuous conduction mode (CCM) or critical conduction mode (CRM) is considered. Available design variables including inductance value, inductor core geometry, capacitor voltage, switching frequency, and modulation scheme (CCM vs. CRM) are explored to identify Pareto-optimal configurations, which can achieve low California Energy Commission (CEC) efficiency drop while also reducing the footprint area of the inductor. The theoretical study predicts that the optimal CRM design can achieve 37% reduced inductor size, while operating with similar efficiency drop, compared to the optimal CCM design. Experimental results, obtained using two separate 40 V, 400 W hardware prototypes for CCM and CRM, are presented to verify the analyses.

14 SOLAR ENERGY↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

Decoupled Active and Reactive Power Control without PLL Requirement for Differential Buck Converter

This paper presents a decoupled active and reactive power control for the differential buck converter. This control does not require phase locked loop (PLL) for synchronization. Also, it achieves active and reactive power control in a simple single control loop structure. The differential buck converter has the capability to compensate the double line frequency power ripple without relying on additional hardware. Particularly, the Common Mode (CM) operation is used for active double line frequency power ripple absorption. Whereas, the Differential Mode (DM) operation is used as an active and reactive power exchanging port between the converter and the grid at the point of common coupling (PCC). The motivation behind this paper proposal are: (i) to avoid PLL induced instabilities, especially, when connecting the differential buck converter with weak grid, and (ii) direct active and reactive power control for the differential buck in a single loop control. The theoretical analyses are verified with a 5 kW converter with only 50 μF decoupling capacitor connected to a weak grid.

Khan, Ahmad↗

Controller Verification of a Smart-Grid Compatible 200 kHz Single-stage Photovoltaic Microinverter

This paper presents control system design, implementation, and experimental validation of a single-stage 400 W, 200 kHz solar photovoltaic (PV) microinverter using hardware-in-the-loop (HIL) and hardware testing. The selected circuit topology is based on a Gallium Nitride (GaN) direct-matrix based dual active bridge (DAB) converter with a low voltage active power decoupler (APD) circuit. Control performance is verified, smart-grid compatibility is tested, and circuit operation is confirmed. Controller HIL (CHIL) is shown to aid in a complex power electronics system design by 1) enabling detailed control development prior to hardware implementation, 2) expanding the use of automated testing, and 3) increasing confidence in control performance prior to prototype testing. Altogether, these factors make HIL a valuable tool in complex power electronic designs.

14 SOLAR ENERGY↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

Single Stage PLL-less Decoupled Active and Reactive Power Control for Weak Grid Interactive Inverters

This paper presents a single stage phase locked loop-less (PLL-less) active and reactive power (PQ) control for single-phase weak grid interactive inverters. The absence of the PLL requirement in the proposed PQ control enhances the stability margin comparing to conventional current control approaches in both the stationary or the synchronous reference frame. Additionally, the proposed control scheme enables direct PQ control with a single loop control structure. This paper demonstrates that the proposed PLL-less PQ control scheme is asymptotically stable if the controller gains are positive. The necessary conditions for supplying the rated active power into the weak grid are derived. The provided analysis shows that certain amount of reactive power injection is necessary to avoid point of common coupling (PCC) voltage collapse when the rated active power is injected into the weak grid. Several case studies are provided to demonstrate the performance of the proposed PLL-less PQ control scheme under weak grid condition.

Khan, Ahmad↗

A machine learning-based fast frequency response control for a VSC-HVDC system

An HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation. However, most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control. Since the traditional system frequency control is dominated by the thermal generators, the advantage of the fast response of the HVDC system is not made fully used. The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system. Different from other frequency deviation tracking strategies, a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost. In this paper, a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression (MRFR) algorithm is proposed. The simulation is carried out with an integrated power system model based on the North American interconnections. The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event, while stabilizing the frequency in advance.

42 ENGINEERING↗

Rotated-Droop Control for Enhanced Stability and Power Decoupling in Microgrids With Complex Line Impedances

Classical droop control in microgrids predominantly assumes inductive line impedance, which simplifies implementation but causes power coupling and steady-state errors in systems with resistive and inductive lines. This paper proposes a rotated-droop control strategy for grid-forming inverters that reformulates the power equations by incorporating the magnitude and angle of the line impedance within a rotated reference frame. This method enhances the decoupling of active and reactive power dynamics without increasing complexity or requiring communication links. A small-signal state-space model was created to capture the dynamic behavior of the system under varying impedance parameters, preserving the original droop gains by rotating the power control structure. This allows eigenvalue-based stability analysis and enhances damping and transient performance. Simulation and experimental results validated the improved power-sharing performance, faster response, and robustness of the proposed method under different impedance conditions. This approach maintains the decentralized structure of the conventional droop control while enabling greater adaptability and scalability, making it suitable for modern inverter-based microgrids with dynamic topologies.

Campo-Ossa, Daniel Dario [Univ. of Puerto Rico, Ag↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

A combined SECM and electrochemical AFM approach to probe interfacial processes affecting molecular reactivity at redox flow battery electrodes

Redox flow batteries are attractive technologies for grid energy storage since they use solutions of redox-active molecules that enable a superior scalability and the decoupling of power and energy density. However, the reaction mechanisms of the redox active components at RFB electrodes are complex, and there is currently a pressing need to understand how interfacial processes impact the kinetics and operational reversibility of RFB systems. Here, we developed a combined electrochemical imaging methodology rooted in scanning electrochemical microscopy (SECM) and atomic force microscopy (AFM) for exploring the impact of electrode structure and conditioning on the electron transfer properties of model redox-active dialkoxybenzene derivatives, 2,5-di-tert-butyl-1,4-bis(2-methoxyethoxy)benzene (C1) and 2,3-dimethyl-1,4-dialkoxybenzene (C7). Using AFM and secondary-ion mass spectrometry (SIMS), we observed the formation of interfacial films with distinct mechanical properties compared to those of cleaved graphitic surfaces, and exclusively during reduction of electrogenerated radical cations. These films had an impact on the median rate and distribution of the electron transfer rate constant at the basal plane of multilayer and single layer graphene electrodes, displaying kinetically-limited values that did not yield the activation expected per the Butler–Volmer model with a transfer coefficient ~0.5. These changes were dependent on redoxmer structure: furthermore, SECM showed strong attenuation of C7 kinetics by a surface layer on MLG and SLG, while C1 kinetics were only affected by SLG. SECM and AFM results together show that these limiting films operate exclusively on the basal plane of graphite, with the edge plane showing a relative insensitivity to cycling and operation potential. Ultimately, this integrated electrochemical imaging methodology creates new opportunities to understand the unique role of interfacial processes on the heterogeneous reactivity of redoxmers at electrodes for RFBs, with a future role in elucidating phenomena at high active concentrations and spatiotemporal variations in electrode dynamics.

25 ENERGY STORAGE↗

Decoupling control technology for medium STOL transports

The advanced control technology is considered that is necessary to cope with the medium STOL transport landing problem and, in particular, the necessity to decouple with active control techniques. It is shown that the need to decouple is independent of the powered lift concept but that the provisioning for decoupling is most greatly dependent on the preassumed piloting technique. The implications of decoupling and active control techniques with respect to pilot technique options, handling quality criteria, flight control mechanization, and the use of piloted simulation as a design tool, are also discussed.

Bird, D. K.↗

Remote pivot decoupler pylon: Wing/store flutter suppressor

A device for suspending a store from an aerodynamic support surface, such an an aircraft wing, and more specifically, for improving upon singlet pivot decoupler pylons by reducing both frequency of active store, alignment, and alignment system space and power requirements. Two links suspend a lower pylon/rack section and releasable attached store from an upper pylon section mounted under the wing. The links allow the lower pylon section to rotate in pitch about a remote pivot point. A leaf spring connected between the lower section and electrical alignment system servomechanism provides pitch alignment of the lower section/store combination. The servomechanism utilizes an electric servomotor to drive the gear train and reversibly move the leaf spring, thereby maintaining the pitch attitude of the store within acceptable limits. The damper strokes when the lower section rotates to damp large oscillations of store.

Hassler, J. M., Jr.↗

A Unified Wireless Charger, On-Board Charger, and Auxiliary Power Module for Electric Vehicle Charging Systems

This paper proposes a unified electric vehicle (EV) charging architecture that integrates wireless power transfer (WPT), an on-board charger (OBC), and an auxiliary power module (APM) within a single architecture. By sharing a multi-functional magnetic structure and active switch bridges, the proposed topology eliminates additional transformers and converter stages, reducing hardware complexity and improving power density. A multipurpose magnetic design achieves magnetic decoupling among the WPT, OBC, and APM functions while maintaining the required coupling for each mode. Through electrical reconfiguration, the WPT operates as an LCC-S converter, whereas the OBC and APM operate as dual-active-bridge (DAB) converters. The system supports multiple operating modes, including simultaneous high-voltage and lowvoltage battery charging. Finite-element and circuit simulations verify the magnetic characteristics and system operation, demonstrating the feasibility of the proposed unified architecture for EV charging applications.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Mitigation of rapid capacity decay in silicon-LiNi 0.6 Mn 0.2 Co 0.2 O 2 full batteries

Silicon (Si)-based materials have been considered as the most promising anode materials for high-energy-density lithium-ion batteries because of their higher storage capacity and similar operating voltage, as compared to the commercial graphite (Gr) anode. But the use of Si anodes including silicon-graphite (Si-Gr) blended anodes often leads to rapid capacity decay in Si-Gr/LiNixMnyCo z O 2 (x+y+z=1) full cells, which has been attributed to surface instability of the Si component. In addition to stabilizing the surface, this work investigates the potential of the Si-Gr blended anodes in a full-cell configuration and its impact on the capacity contribution from active components. Using dQ/dV plots of the full cells, a powerful but simple-to-implement differential potential approach is developed to decouple the capacity contribution and degradation from the graphite and silicon components. Data collected from three-electrode cells confirm the results from the differential potential approach, which suggests a voltage slippage to a higher voltage at the blended anode side. Additionally, the voltage slippage causes a reduced utilization of the Gr component and exacerbates side reactions between the Si-Gr anode and carbonate electrolytes. Furthermore, based on these failure mechanisms, we adopted a mitigation strategy to tune the open circuit voltage of the prelithiated anode while stabilizing the surface. As a result, the full cells with the modified Si-Gr anodes (mass loading, 2.5 mAh/cm 2 ) offer a highly reversible full-cell energy density of 390 Wh/kg (based on the mass of both anode and cathode materials in a full cell) with a cycling CE of 99.9% over 200 cycles.

25 ENERGY STORAGE↗

A Decoupled Droop Control Strategy for Cascaded Multicell Inverter with Low-Frequency Modulation

Cascaded multicell inverter (CMI), featured by its merits of modularity and fault-tolerance, is suitable for medium-voltage applications without using bulky step-up transformers. However, little research has reported grid-forming control of the CMI for the application in the power grid with high penetrations of inverter-interfaced generation. To bridge this research gap, this paper proposes a novel droop control strategy for the CMI with a low-frequency modulation to offer inertia and reactive power support to the power grid. A decoupled Q/V droop control strategy is proposed to eliminate the coupling effect from the P/ω control loop caused by the phase-angle difference between the voltages of the CMI and the grid. The output of the Q/V control loop is set as the reference voltage for each cell of the CMI, which makes the CMI naturally a voltage source to provide a grid-forming capability. Finally, the proposed control strategy shows great active and reactive power regulation and sharing capability, which is validated by simulation on two 100 kW, 2.4 kV CMIs connected in parallel to a power grid.

14 SOLAR ENERGY↗