On the adiabatic temperature gradient in the earth's shell ob adiabaticheskom gradiente temperatur v obolochke zemli
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A method of calculating the temperature of thick walls has been developed in which the time series and the response to a unit triangle variation of surface temperature concepts are used, together with essentially standard formulas for transient temperature and heat flow into thick walls. The method can be used without knowledge of the mathematical tools of its development. The method is particularly suitable for determining the wall temperature in one-dimensional thermal problems in aeronautics where there is a continuous variation of the heat-transfer coefficient and adiabatic-wall temperature. The method also offers a convenient means for solving the inverse problem of determining the heat-flow history when temperature history is known.
Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30 degree inclination angle.
Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center-line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30-deg inclination angle.
Explore the source record for details and available documents.
A numerical investigation is conducted of the effect of compressibility on 3D thermal convection in a basally heated highly viscous fluid spherical shell (representing the earth's mantle). It was found that compressibility has little effect on the spatial structure of steady convection when the superadiabatic temperature drop across the shell, Delta T(sa), is comparable to a characteristic adiabatic temperature. When the Delta T(sa) is about an order of magnitude smaller than the adiabatic temperature, compressibility effect is significant. It is shown that compressibility affects the pattern evolution of the irregular solutions; fewer upwelling plumes are produced with increasing compressibility.
There is considerable interest in dendritic solidification because of the influence dendrites have in the determination of microstructure, and thereby in the physical properties of cast metals and alloys. Current theories and models of dendritic growth generally couple diffusion effects in the melt with the physics of the interface. Data and subsequent analysis prior of the tip growth speed and radii of thermal succinonitrile dendrites in the near-convection free, on-orbit, free-fall environment demonstrate that these theories yield predictions that are reasonably in agreement with the results of experiment. However, data and analysis for assessing the interfacial physics component of theory are not sufficiently detailed or definitive. To study fundamental aspects of dendritic interface stability, we are measuring and modeling the kinetics and morphology of dendrites as they evolve from one well-defined steady state at a pre-set supercooling, through a transient stage, to a different well-defined steady state. More specifically, we subject succinonitrile dendrites, growing under steady-state conditions, to a rapid change in pressure. This leads to a rapid change in thermal driving force from the corresponding change in both the equilibrium melting temperature due to the Clapeyron effect, and a change in the far-field temperature due to adiabatic temperature changes in the bulk liquid and solid. Subsequently, we observe transformations from a well-characterized initial state into a new steady-state. Initial data reveal that the dendrite tip velocity changes almost as fast as the pressure charges, while the tip radius changes occur more slowly, taking from 10 60 seconds depending on the size of the step change and the final supercooling. Computer modeling of this process shows both agreements and disagreements with the experimental data. In making these observations and measurements, we are gaining new understandings of interfacial dynamics and state-selection physics.
Experiments to determine film cooling with air injection through holes into turbulent air boundary layer on flat plate
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Cornell University Portable Radar Interferometer (CUPRI) observed two extremely strong layers of Polar Mesosphere Summer Mesosphere (PMSE) thirty minutes prior to the launch of Salvo C of the NLC-91 campaign. The lower layer exhibited a S/N ratio of 42 dB (the second strongest event of NLC-91), vertical velocities of a few m/s, and a narrow spectral width, suggesting that it was the result of partial reflections. The upper layer, in contrast, exhibited sinusoidal structures in vertical velocity with peak amplitudes greater than +/- 10 m/s and wide spectral widths. These structures were observed to grow and steepen with altitude until they broke and produced turbulent radar scattering. We conclude that the rapid rate of growth of hte wave with altitude was the result of a depressed mesopause temperature and a nearly adiabatic temperature gradient at PMSE heights and that the simultaneous measurement of both a low mesopause temperature and strong PMSE supports recent theories that find the presence of charged aerosols to be the key to the unique radar cross sections associated with PMSE.
The adiabatic compression of oxygen has been identified as an ignition source for systems operating in enriched oxygen atmospheres. Current practice is to evaluate the temperature rise on compression by treating oxygen as an ideal gas with constant heat capacity. This paper establishes the appropriate thermodynamic analysis for the common occurrence of adiabatic compression of oxygen and in the process defines a satisfactory equation of state (EOS) for oxygen. It uses that EOS to model adiabatic compression as isentropic compression and calculates final temperatures for this system using current approaches for comparison.
Boundary layer transition measurements were made in flight on a 10 deg transition cone tested previously in 23 wind tunnels. The cone was mounted on the nose of an F-15 aircraft and flown at Mach numbers room 0.5 to 2.0 and altitudes from 1500 meters (5000 feet) to 15,000 meters (50,000 feet), overlapping the Mach number/Reynolds number envelope of the wind tunnel tests. Transition was detected using a traversing pitot probe in contact with the surface. Data were obtained near zero cone incidence and adiabatic wall temperature. Transition Reynolds number was found to be a function of Mach number and of the ratio of wall temperature to adiabatic all temperature. Microphones mounted flush with the cone surface measured free-stream disturbances imposed on the laminar boundary layer and identified Tollmien-Schlichting waves as the probable cause of transition. Transition Reynolds number also correlated with the disturbance levels as measured by the cone surface microphones under a laminar boundary layer as well as the free-stream impact.
A multiple regression statistical model is applied to investigate the existence of upper-stratospheric ozone, temperature, and zonal wind responses to long-term (solar cycle) changes in solar ultraviolet radiation using 11.5 years of reprocessed Nimbus-7 Solar Backscattered Ultraviolet (SBUV) data and 12.4 years of National Meteorological Center (NMC) data. A positive solar cycle variation of independently measured ozone and temperature occurs with maximum amplitude near the low-latitude stratopause. The seasonal solar regression coefficients near 1 mb for both ozone and temperature occur at low latitudes supporting a role for photochemical and radiative forcing in their origin. Zonal wind perturbations that correlate with long-term solar ultraviolet variations are a strong function of season and pressure level. Above approximately 2 mbar, the largest solar-correlated zonal wind enhancements occur at middle winter latitudes near the time of winter solstice in both hemispheres. The Northern Hemisphere December enhancement at 1 mb was especially large, 23 +/- 9 m/s from solar minimum to maximum during the last solar cycle. The derived ozone, temperature, and zonal wind increases with increasing solar ultraviolet flux near the stratopause are larger than predicted by models that consider primarily photochemical and radiative processes. The higher ozone and temperature response amplitudes at low latitudes may be due to modified ozone transport and adiabatic temperature changes induced by the dynamical response. If the midlatitude winter solstice wind enhancements are solar induced, their high amplitudes require a positive feedback due to wave-mean flow interaction such that the planetary wave drag on the flow is reduced under solar maximum conditions.
The present report deals with the development of a thermometer for recording stagnation temperature in compressible mediums in turbulent flow within 1 to 2 percent error of the adiabatic temperature in the stagnation point, depending upon the speed. This was achieved by placing the junction of a thermocouple near the stagnation point of an aerodynamically beneficial body, special care being taken to assure an uninterrupted supply of fresh compressed air on the junction together with the use of metals of low thermal conductivity, thus keeping heat-transfer and heat-dissipation losses to a minimum. In other experiments the use of the plate thermometer was proved unsuitable for practical measurements by reason of its profound influence in the reading by the Reynolds number and by the direction of flow.
Thermal structure measurements obtained by the two VEGA balloons show the Venus middle cloud layer to be generally adiabatic. Temperatures measured by the two balloons at locations roughly symmetric about the equator differed by about 6.5 kelvins at a given pressure. The VEGA-2 temperatures were about 2.5 kelvins cooler and those of VEGA-1 about 4 kelvins warmer than temperatures measured by the Pioneer Venus Large Probe at these levels. Data taken by the VEGA-2 lander as it passed through the middle cloud agreed with those of the VEGA-2 balloon. Study of individual frames of the balloon data suggests the presence of multiple discrete air masses that are internally adiabatic but lie on slightly different adiabats. These adiabats, for a given balloon, can differ in temperature by as much as 1 kelvin at a given pressure.
The effects of higher modes of convection on the thermal evolution of a small planetary body is investigated. Three sets of models are designed to specify an initially cold and differentiated, an initially hot and differentiated, and an initially cold and undifferentiated Moon-type body. The strong temperature dependence of viscosity enhances the thickening of lithosphere so that a lithosphere of about 400 km thickness is developed within the first billion years of the evolution of a Moon-type body. The thermally isolating effect of such a lithosphere hampers the heat flux out of the body and increases the temperature of the interior, causing the solid-state convection to occur with high velocity so that even the lower modes of convection can maintain an adiabatic temperature gradient there. It is demonstrated that the effect of solid-state convection on the thermal evolution of the models may be adequately determined by a combination of convection modes up to the third or the fourth order harmonic. The inclusion of higher modes does not affect the results significantly.
A high-performance design, and fabrication and growth processes to implement the design, have been devised for encapsulating a hydrated salt in a container that both protects the salt and provides thermal conductance between the salt and the environment surrounding the container. The unitary salt/container structure is known in the art as a salt pill. In the original application of the present design and processes, the salt is, more specifically, a hydrated paramagnetic salt, for use as a refrigerant in a very-low-temperature adiabatic demagnetization refrigerator (ADR). The design and process can also be applied, with modifications, to other hydrated salts. Hydrated paramagnetic salts have long been used in ADRs because they have the desired magnetic properties at low temperatures. They also have some properties, disadvantageous for ADRs, that dictate the kind of enclosures in which they must be housed: Being hydrated, they lose water if exposed to less than 100-percent relative humidity. Because any dehydration compromises their magnetic properties, salts used in ADRs must be sealed in hermetic containers. Because they have relatively poor thermal conductivities in the temperature range of interest (<0.1 K), integral thermal buses are needed as means of efficiently transferring heat to and from the salts during refrigeration cycles. A thermal bus is typically made from a high-thermal-conductivity met al (such as copper or gold), and the salt is configured to make intimate thermal contact with the metal. Commonly in current practice (and in the present design), the thermal bus includes a matrix of wires or rods, and the salt is grown onto this matrix. The density and spacing of the conductors depend on the heat fluxes that must be accommodated during operation.