Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advances using Monte Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Coupled reactors analysis: New needs and advances using Monte Carlo methodology

Coupled reactors and the coupling features of large or heterogeneous core reactors can be investigated with the Avery theory that allows a physics understanding of the main features of these systems. However, the complex geometries that are often encountered in association with coupled reactors, require a detailed geometry description that can be easily provided by modern Monte Carlo (MC) codes. This implies a MC calculation of the coupling parameters defined by Avery and of the sensitivity coefficients that allow further detailed physics analysis. The results presented in this paper show that the MC code SERPENT has been successfully modifed to meet the required capabilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Secondary Beams at Jefferson Laboratory

This thesis explores the possibility of producing secondary beams at the Thomas Jefferson National Accelerator Facility (TJNAF). Their possible applications in future experiments are studied using advanced Monte Carlo simulations with state-of-the-art software. In Jefferson Lab’s Hall-A, the interaction of the high-current O(100) µA, medium-energy O(11) GeV electron beam produced by the Continuous Electron Beams Accelerator Facility (CEBAF) with the Beam-Dump (BD) generates a substantial shower of standard model particles. This interaction creates a high-intensity secondary muon and neutrino beam and hypothetical Light Dark Matter (LDM) particles. Additionally, with the proposed Compact Photon Source (CPS), Hall-D could offer the possibility of producing an intense muon beam alongside a photon beam.

Fulci, Antonino↗

Studying the information content of TMDs using Monte Carlo generators

Theoretical advances in studies of the nucleon structure have been spurred by recent measurements of spin and/or azimuthal asymmetries worldwide. One of the main challenges still remaining is the extraction of the parton distribution functions, generalized to describe transverse momentum and spatial distributions of partons from these observables with no or minimal model dependence. In this topical review we present the latest developments in the field with emphasis on requirements for Monte Carlo event generators, indispensable for studies of the complex 3D nucleon structure, and discuss examples of possible applications.

3D nucleon structure↗

Recent Advances in the Use of TRIPOLI-4 Monte Carlo Code for Radiation Protection and Shielding Calculations - Paper 47

TRIPOLI-4 is a general purpose radiation transport code. It uses the continuous-energy Monte Carlo method to simulate neutron, photon, electron and positron transport in three-dimensional geometries. The main application areas of TRIPOLI-4 code include radiation protection and shielding, fission reactor physics, nuclear criticality safety, fusion reactor design, and nuclear instrumentation. For the radiation protection and shielding calculations with TRIPOLI-4 code, miscellaneous radiation sources options, various variance reduction options, and many useful tally options are available. Perturbation calculations on material densities and nuclide concentrations are routinely used in radiation protection applications. Parallel calculations with TRIPOLI-4 are also easy to perform with a PC under the linux/unix OS. To help the users to get the feedback from their test runs during the input data preparation and adjustment and to analyze the intermediate and final results from their production runs, several user-interface tools have been introduced. By using some application cases in the fields of radiation shielding, radiation dosimetry, and gamma spectrometry, this paper summarizes and demonstrates some essential improvements and possibilities in the use of TRIPOLI-4 code on fixed source calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-448: On the Perturbation Factor P-cav of the Markus Parallel Plate Ion Chambers in Clinical Electron Beams, Monte Carlo Based Reintegration of An Historical Experiment

Purpose: All present dosimetry protocols recommend well-guarded parallel-plate ion chambers for electron dosimetry. For the guard-less Markus chamber an energy dependent fluence perturbation correction pcav is given. This perturbation correction was experimentally determined by van der Plaetsen by comparison of the read-out of a Markus and a NACP chamber, which was assumed to be “perturbation-free”. Aim of the present study is a Monte Carlo based reiteration of this experiment. Methods: Detailed models of four parallel-plate chambers (Roos, Markus, NACP and Advanced Markus) were designed using the Monte Carlo code EGSnrc and placed in a water phantom. For all chambers the dose to the active volume filled with low density water was calculated for 13 clinical electron spectra (E{sub 0}=6-21 MeV) at the depth of maximum and at the reference depth under reference conditions. In all cases the chamber's reference point was positioned at the depth of measurement. Moreover, the dose to water DW was calculated in a small water voxel positioned at the same depth. Results: The calculated dose ratio D{sub NACP}/D{sub Markus}, which according to van der Plaetsen reflects the fluence perturbation correction of the Markus chamber, deviates less from unity than the values given by van der Plaetsen's but exhibits a similar energy dependence. The same holds for the dose ratios of the other well guarded chambers. But, in comparison to water, the Markus chamber reveals the smallest overall perturbation correction which is nearly energy independent at both investigated depths. Conclusion: The simulations principally confirm the energy dependence of the dose ratio D{sub NACP}/D{sub Markus} as published by van der Plaetsen. But, as shown by our simulations of the ratio D{sub W}/D{sub Markus}, the conclusion drawn in all dosimetry protocols is questionable: in contrast to all well-guarded chambers the guard-less Markus chamber reveals the smallest overall perturbation correction and also the smallest energy dependence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of a Subject-specific Ankle Sprain Simulation to Extrinsic Versus Intrinsic Biomechanical Factors

Ankle sprains are the most common musculoskeletal injury in sport and military activity, despite existing prophylactic strategies. The purpose of this report was to develop a probabilistic simulation of lateral ankle sprains during single-limb drop landing, towards accelerating innovation in ankle sprain prevention. A deterministic, subject-specific musculoskeletal model was extended with automation and probabilistic distributions on sprain-related biomechanical factors. Probabilistic simulations were generated using traditional Monte Carlo techniques and the advanced mean value method, a more computationally-efficient approach. Predicted distributions of peak ankle joint rotations, velocities, and moments borne by supporting passive structures agreed favorably with the deterministic model and with reports of real sprain biomechanics. Parameter sensitivities identified that predictions were most strongly influenced by drop height, subtalar joint posture at contact, invertor/evertor co-activation, and passive ankle stiffness. The advanced mean value method predicted confidence bounds comparable to a 1000-trial Monte Carlo simulation, and required only 14 model evaluations and 4-min processing time. The extended probabilistic simulation may be useful to virtually test new prophylactic strategies for ankle sprains, and is made available for open-source use (https://simtk.org/projects/sprain-sim).

60 APPLIED LIFE SCIENCES↗

Recent advances and future prospects for Monte Carlo

The history of Monte Carlo methods is closely linked to that of computers: The first known Monte Carlo program was written in 1947 for the ENIAC; a pre-release of the first Fortran compiler was used for Monte Carlo In 1957; Monte Carlo codes were adapted to vector computers in the 1980s, clusters and parallel computers in the 1990s, and teraflop systems in the 2000s. Recent advances include hierarchical parallelism, combining threaded calculations on multicore processors with message-passing among different nodes. With the advances In computmg, Monte Carlo codes have evolved with new capabilities and new ways of use. Production codes such as MCNP, MVP, MONK, TRIPOLI and SCALE are now 20-30 years old (or more) and are very rich in advanced featUres. The former 'method of last resort' has now become the first choice for many applications. Calculations are now routinely performed on office computers, not just on supercomputers. Current research and development efforts are investigating the use of Monte Carlo methods on FPGAs. GPUs, and many-core processors. Other far-reaching research is exploring ways to adapt Monte Carlo methods to future exaflop systems that may have 1M or more concurrent computational processes.

99 GENERAL AND MISCELLANEOUS↗

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles is investigated using a novel transient three-dimensional computational fluid dynamics model. The model couples particle–gas hydrodynamics of solid–gas flows laden with polydisperse particles, radiative heat transfer in non-grey absorbing, emitting and anisotropically-scattering multi-component participating media, conduction heat transfer in the gas phase, and interfacial convection heat transfer. The multiphase particle-in-cell method is used to predict high-fidelity solid–gas flow characteristics, such as the local discrete particle size distribution, with increased computational efficiency by combining the advantages of both Eulerian and Lagrangian methods. The multi-component radiative transfer model is implemented using an advanced collision-based Monte Carlo ray-tracing method. The number of the prescribed discrete particle components is found to be the key parameter affecting the computational accuracy and efficiency, which primarily depends on the size distribution of the particles. For the model particle–gas flow featuring free-falling Gamma-distributed ceramic particles exposed to concentrated solar irradiation, the particle volume fraction, radiative, fluid flow and thermal characteristics appear to converge with the increasing number of the discrete particle components. Five particle components are sufficient to obtain physically meaningful results. A further increase in the number of the particle components only slightly increases the accuracy of the numerical predictions at the expense of a rapidly increasing computational time. For five particle components, the particle vertical velocity at the receiver exit for particles with the diameter of 43.4 μm is 57% of that for the particles with the diameter of 202.8 μm. The temperatures of these two particle components increase from the initial ambient values by factors of 2 and 1.2, respectively, during the simulation time. In conclusion, the model developed allows for increased fidelity of particle–gas flow simulations with significant radiative effects.

97 MATHEMATICS AND COMPUTING↗

Impact of time and space evolution of ion tracks in nonvolatile memory cells approaching nanoscale

Swift heavy ions impacting on matter lose energy through the creation of dense tracks of charges. The study of the space and time evolution of energy exchange allows understanding the single event effects behavior in advanced microelectronic devices. In particular, the shrinking of minimum feature size of most advanced memory devices makes them very interesting test vehicles to study these effects since the device and the track dimensions are comparable; hence, measured effects are directly correlated with the time and space evolution of the energy release. In this work we are studying the time and space evolution of ion tracks by using advanced non volatile memories and Monte Carlo simulations. Experimental results are very well explained by the theoretical calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

REVISITING COINCIDENCE RATE BETWEEN GRAVITATIONAL WAVE DETECTION AND SHORT GAMMA-RAY BURST FOR THE ADVANCED AND THIRD GENERATION

We use realistic Monte Carlo simulations including both gravitational-wave (GW) and short gamma-ray burst (sGRB) selection effects to revisit the coincident rate of binary systems composed of two neutron stars or a neutron star and a black hole. We show that the fraction of GW triggers that can be observed in coincidence with sGRBs is proportional to the beaming factor at z = 0, but increases with the distance until it reaches 100% at the GW detector horizon distance. When this is taken into account the rate is improved by a factor of three compared to the simple beaming factor correction. We provide an estimate of the performance future GRB detectors should achieve in order to fully exploit the potentiality of the planned third-generation GW antenna Einstein Telescope, and we propose a simple method to constrain the beaming angle of sGRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

As-Run Physics Analysis for the EPRI-1 Experiment

The purpose of this ECAR is to document the as-run physics analysis for the Electric Power Research Institute (EPRI)-1 experiment located in the Center Flux Trap (CFT). EPRI-1 was irradiated during cycle 157C. The experiment irradiation ended on February 15, 2015. The as-run heat rates, DPA, and flux/fluence results were calculated using the Monte Carlo N-Particle (MCNP) Advanced Test Reactor (ATR) full core model. The heat rates, DPA, and flux are calculated based on an average center lobe power of 21.1 MW. The fluence and DPA is based on the operating time of 5.4 days. ORIGEN2 Version 2.2 was used to calculate the isotopic concentration in grams for the EPRI-1 experiment. The source term analysis was performed as requested by the project staff. The results of this analysis may be used to support Post-Irradiation Examination (PIE)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

Experimental Steps toward a Density Law for Chlorine-Crediting Criticality Models of Aqueous Plutonium solutions

Criticality accident prevention is an essential safety consideration for all operations involving fissionable and fissile materials. Predictive criticality calculations using advanced neutron transport codes, such as Monte Carlo N-Particle Transport (MCNP), are invaluable tools for designing and implementing operational limits. While indispensable, these tools are limited by the quality and accuracy of the inputs that the user provides to define the modeled system. Parameters such as atomic composition, shape, and material density must be accurately defined to obtain a meaningful result. In the case of material property details for a plutonium model, accurate material characterization data is sometimes sparse. Thus limitations in calculation accuracy can be reduced by improving our knowledge of material properties in the targeted fissile systems. One of the biggest remaining challenges to accurately defining fissile systems is the description of aqueous fissile solutions. Even simple properties, such as density, are not well-known for fissile solutions relevant to nuclear energy and security. Described here are initial efforts undertaken to improve criticality calculation inputs for fissile plutonium chloride solutions in water. This effort is focused on experimentally determining accurate solution characteristics for ternary plutonium chloride/hydrochloric acid/water systems, by measurement of water activity and solution density. The effect of inputting experimental densities for these solutions into MCNP criticality calculations is compared to the traditional approach of modeling an idealized (and fictitious) plutonium-water mixture. Expansion of these efforts to a working density law for aqueous plutonium chloride solutions is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrades to Monteburns, version 3.0

Monteburns, a Monte Carlo burnup code which has the flexibility to model time-dependent isotopic changes for a variety of nuclear systems by linking the neutron transport code MCNP/X to a production/depletion code, has undergone several performance upgrades recently that have increased the code's capabilities. Once limited to a specific number of regions, enhancements have been implemented that afford a much greater number of burn materials, such that users will be more limited by the physical constraints of their computing environment as opposed to inherent limits built into the coding of Monteburns. In conjunction with the increase in the number of burn materials, parallel execution of a production/depletion code of choice has been implemented, such that users have the option of using CINDER90, 0RIGEN2, or the newly released version of ORIGEN. Finally, the recoverable energy per fission calculation was upgraded to include capture gamma energy deposited in all specified materials as a function of irradiation time. The sum of the prompt and delayed recoverable energies from fission was obtained as before. These upgrades were first tested on a rigorous 1/8 core model of a Pressurized Water Reactor with fresh, once- and twice-burned fuel. We can now model several orders of magnitude more materials using Monte Carlo techniques, which is a significant advance in the reactor modeling world. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Results of a New Deterministic Iterative Image Reconstruction Algorithm - Paper 117

Iterative reconstruction techniques have become the standard for Single Photon Emission Computed Tomography (SPECT). Advances in computing have allowed these techniques to incorporate more and more detail; however, computation time must be balanced against increased detail. Monte Carlo methods are generally used for modeling the physics of a SPECT study, but can have long computation times. Advances in Monte Carlo-based scatter correction have shown reasonable results, but scatter estimation by measuring narrow energy windows remains more common. An iterative reconstruction technique using a deterministic transport code has been proposed as an alternative. This paper presents preliminary results of the new technique in which the TITAN deterministic code completes the forward projection step in a maximum likelihood expectation maximization (ML-EM) reconstruction of SPECT data. The effectiveness of the deterministic algorithm is examined for a 2-dimensional phantom. This work demonstrates the feasibility of using the TITAN code in an iterative reconstruction algorithm. The appropriate deterministic parameters were chosen by comparing sinograms produced with different mesh sizes, quadrature sets, and anisotropic scattering orders. The TITAN code was then successfully used as the forward projection step in an iterative reconstruction algorithm with a 2-dimensional homogeneous phantom. The impact of deterministic parameters on reconstruction quality is being investigated, along with the incorporation of a smoothing filter. The TITAN source code is being modified to include the ML-EM algorithm and iteration steps. This will significantly improve computation time by eliminating the repeated reading and writing of files for each iteration and allowing some steps to be completed in parallel. Further testing of the new reconstruction algorithm for more realistic phantoms is also underway. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of Time Dependent Reactor and Sensor Physics on Core Power Synthesis

Online synthesis of the power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins, and to provide essential knowledge associated with the burnup of the fuel. In light water reactors (LWRs), power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report aims to study the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a LWR. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative pressurized water reactor low-enriched uranium (LEU) core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used, as well, to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative (PBI) method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly under- or over-approximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumption leads to severe levels of error, approaching 25% at maximum. The authors also discovered that V SPNDs are extraordinarily robust in the low-enriched uranium fuel cycle considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Time-Dependent Reactor and Sensor Physics on Core Power Synthesis (Rev.1)

Online synthesis of power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins and to provide essential knowledge associated with the burnup of the fuel. In light-water reactors, power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report examines the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a pressurized water reactor (PWR), considering the typical low-enriched uranium (LEU, 3%-5% enrichment) fuel cycle as well as the higher enrichment LEU+ (5%-8% enrichment) fuel cycle. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative PWR LEU core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used as well to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori power distribution assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters and the extended nature of the LEU+ fuel cycle in comparison with LEU. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly underapproximated or overapproximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumptions leads to severe levels of error, approaching 25% at maximum (for LEU). The authors also discovered that V SPNDs are extraordinarily robust in both the LEU and LEU+ fuel cycles considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗