Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air Flow Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Strategy Guideline: Compact Air Distribution Systems

This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Compact Air Distribution Systems

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft 2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress on design and development of polymer electrolyte membrane fuel cell systems for vehicle applications: A review

Due to its merit of rapid start-up, lower pollution and high energy conversion efficiency, polymer electrolyte membrane fuel cell (PEMFC) system has been considered as one of the most promising propulsion system for electric vehicles. Although the development of PEMFC system has been experienced rapid growth for several decades, many challenges still need to be overcome for promoting commercialize fuel cell technology. In order to understand the design concept of PEMFC system and update the development status of fuel cell system for electric vehicle, as well as help fuel cell system developers or electric vehicle manufacturers to improve the performance and durability of fuel cell electric vehicles, the up-to-date technical targets such as power density, operation temperature, dynamic response and lifetime for PEMFC systems in different countries have been summarized and compared in this review. Furthermore, from the aspects of hydrogen management and air management and major degradation mechanisms under various operation conditions, the design status of the system configuration in fuel cell has also been analyzed in detail. Finally, according to the design and intended operation the mitigation strategies have also been proposed to promote the development of PEMFC system for electric vehicle applications.

air flow management↗

Cyber-Physical Simulation of an Innovative Solid Oxide Electrolysis Cell - Gas Turbine (SOEC-GT) Hybrid Energy System

To produce green hydrogen at scale and at low cost, the solid oxide electrolysis cell (SOEC) systems would be tied to renewable power sources (mainly solar and wind), leveraging zero-carbon electricity at low prices and even nearly free during overgeneration scenarios. However, due to the intermittency of renewable power generation, the SOEC system is subjected to rapid load transitions that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). This can result in fast degradation and thus greatly reduce the SOEC’s lifetime. Our team at the National Energy Technology Laboratory has demonstrated that the anode air flow can have a crucial role in SOEC thermal management. Typically, a higher air flow rate can help to mitigate the local temperature gradient distortion during rapid load transitions. To move a large amount of air, the gas turbine (GT; i.e., compressor-turbine-generator set) has been regarded as the most mature and efficient technology. In this presentation, we show the configuration and preliminary results of an innovative SOEC-GT hybrid energy system in a cyber-physical simulation (CPS) approach.

Zhang, Biao↗

Tiny Device Mimics Human Lung Function

Scientists at Los Alamos National Laboratory are developing a miniature, tissue-engineered artificial lung that mimics the response of the human lung to drugs, toxins and other agents. “We breathe in and out thousands of times every day. And while we have control over what we eat or drink, we don’t always have control over what we breathe in,” said Jennifer Harris of Biosecurity and Public Health at Los Alamos, "and so we’re making this miniature lung to be able to test on actual human cells whether something in the environment, or a drug, is toxic or harmful to us." Nicknamed “PuLMo” for Pulmonary Lung Model (Pulmo is also the Latin word for "lung")the device consists of two major parts, the bronchiolar unit and the alveolar unit—just like the human lung. The units are primarily made from various polymers and are connected by a microfluidic “circuit board” that manages fluid and air flow. “When we build our lung, we not only take into account the aspects of different cell types, the tissues that are involved, we also take into account that a lung is supposed to breathe, so PuLMo actually breathes,” said Pulak Nath of Applied Modern Physics, who leads engineering efforts for the project. The most exciting application of PuLMo is a potentially revolutionary improvement in the reliability of drug-toxicity assessments and the prediction of new pharmaceutical success in humans, according to Harris. The PuLMo may also be designed to mimic lung disease conditions, such as Chronic Obstructive Pulmonary Disease (COPD) and asthma, and may be used to study lung air-flow dynamics to better understand the mechanisms of toxins and drug delivery and the effects of smoking, particularly the less-understood effects of e-cigarettes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing the CSP Tower Air Brayton Cycle System to Meet the SunShot Objectives - Final Technical Report

The objective of this project is to increase Concentrated Solar Power (CSP) tower air receiver and gas turbine temperature capabilities to 1,000ºC by the development of a novel gas turbine combustor, which can be integrated on a megawatt-scale gas turbine, such as the Solar Turbines Mercury 50™. No combustor technology currently available is compatible with the CSP application target inlet air temperature of 1,000°C. Autoignition and flashback at this temperature prevent the use of conventional lean pre-mix injectors that are currently employed to manage NOx emissions. Additional challenges are introduced by the variability of the high-temperature heat source provided by the field of solar collectors, the heliostat in CSP plants. For optimum energy generation from the power turbine, the turbine rotor inlet temperature (TRIT) should remain constant. As a result of changing heat load provided to the solar collector from the heliostat, the amount of energy input required from the combustion system must be adjusted to compensate. A novel multi-bank lean micro-mix injector has been designed and built to address the challenges of high-temperature combustion found in CSP applications. The multi-bank arrangement of the micro-mix injector selectively injects fuel to meet the heat addition requirements to maintain constant TRIT with changing solar load. To validate the design, operation, and performance of the multi-bank lean micro-mix injector, a novel combustion test facility has been designed and built at Southwest Research Institute® (SwRI®) in San Antonio, TX. This facility, located in the Turbomachinery Research Facility, provides in excess of two kilograms per second of compressed air at nearly eight bar pressure. A two-megawatt electric heater raises the inlet temperature to 800°C while a secondary gas-fired heater extends the operational temperature range of the facility to 1,000°C. A combustor test rig connected to the heater has been designed and built to test the multi-bank lean micro-mix injector over the range of CSP operating conditions. The fuel is controlled and selectively delivered to the banks of the injector based on combustor inlet conditions that correspond to turbine operating points. The combustor rig is equipped with a data acquisition system and a suite of instrumentation for measuring temperature, pressure, and species concentration. This unique test facility has been built and commissioned and a prototype of the multi-bank lean micro-mix injector design has been tested. Operation of the combustor and injector has been demonstrated over the full range of CSP inlet conditions and for the range of turbine load conditions specified. The multi-bank operation of the injector has been proven to be an effective design for managing the variable flow rates of air and fuel due to changing inlet conditions from the solar field and turbine loads.

14 SOLAR ENERGY↗

Stack Test Summary for TA-59-0001

The Radioactive Air Emissions Management (RAEM) team performed stack flow characterization tests at Technical Area (TA) 59 Building 0001 Exhaust Stack (ES) 8. These tests were completed in accordance with Title 40 of the Code of Federal Regulations (CFR), Part 61, Subpart H and the American National Standards Institute (ANSI) N13.1-1999 required by the Clean Air Act. Subpart H of the regulation is the National Emission Standards for Hazardous Air Pollutants (NESHAP) for radionuclides, which compliance with is maintained by the REAM team.

54 ENVIRONMENTAL SCIENCES↗

Lighting system with thermal management system

Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

42 ENGINEERING↗

Lighting system with thermal management system

Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

42 ENGINEERING↗

Lighting system with thermal management system

Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

25 ENERGY STORAGE↗

Lighting system with thermal management system

Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

25 ENERGY STORAGE↗

Lighting system with thermal management system

Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Warming of the lower Columbia River , 1853 to 2018

Abstract Water temperature is a critical ecological indicator; however, few studies have statistically modeled century‐scale trends in riverine or estuarine water temperature, or their cause. Here, we recover, digitize, and analyze archival temperature measurements from the 1850s onward to investigate how and why water temperatures in the lower Columbia River are changing. To infill data gaps and explore changes, we develop regression models of daily historical Columbia River water temperature using time‐lagged river flow and air temperature as the independent variables. Models were developed for three time periods (mid‐19th, mid‐20th, and early 21st century), using archival and modern measurements (1854–1876; 1938–present). Daily and monthly averaged root‐mean‐square errors overall are 0.89°C and 0.77°C, respectively for the 1938–2018 period. Results suggest that annual averaged water temperature increased by 2.2°C ± 0.2°C since the 1850s, a rate of 1.3°C ± 0.1°C/century. Increased water temperatures are seasonally dependent. An increase of approximately 2.0°C ± 0.2°C/century occurs in the July–Dec time‐frame, while springtime trends are statistically insignificant. Rising temperatures change the probability of exceeding ecologically important thresholds; since the 1850s, the number of days with water temperatures over 20°C increased from ~5 to 60 per year, while the number below 2°C decreased from ~10 to 0 days/per year. Overall, the modern system is warmer, but exhibits less temperature variability. The reservoir system reduces sensitivity to short‐term atmospheric forcing. Statistical experiments within our modeling framework suggest that increased water temperature is driven by warming air temperatures (~29%), altered river flow (~14%), and water resources management (~57%).

54 ENVIRONMENTAL SCIENCES↗

Improved Battery Pack Thermal Management to Reduce Cost and Increase Energy Density: Cooperative Research and Development Final Report, CRADA Number CRD-12-499

Under this CRADA NREL will support Creare's project for the Department of Energy entitled 'Improved Battery Pack Thermal Management to Reduce Cost and Increase Energy Density' which involves the development of an air-flow based cooling product that increases energy density, safety, and reliability of hybrid electric vehicle battery packs.

25 ENERGY STORAGE↗

Next Step Toward Widespread Residential Deep Energy Retrofits

The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Next Step Toward Widespread Residential Deep Energy Retrofits

The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theory of Carbon Dioxide Absorption by Hanford Waste - 18208

Hanford nuclear waste has a very high pH, and Hanford tanks are ventilated with air. Air has CO{sub 2(g)} in it, which is an acid, so it has some affinity for the waste. The absorption of CO{sub 2} by the waste is important because CO{sub 2} absorption consumes hydroxide at the liquid-air interface, and the hydroxide is important for inhibiting tank corrosion. NaOH is periodically added to some tanks in order to mitigate the surface acidification. The NaOH added then becomes part of the waste and must be treated as waste, increasing the cost of the mission. The Hobbs Equation, developed at the Savannah River site, is used at Hanford to predict CO{sub 2} absorption from the tank ventilation system. In this study, the Hobbs Equation functional form is theoretically evaluated from thermodynamic calculations of CO{sub 2} absorption, and diffusion rates in the waste surface. This study theoretically justifies the empirical equation reported by Hobbs. Thermodynamic calculations performed using the Environmental Simulation Program (ESP) software on a typical double-shell tank waste composition indicate that essentially 100 % of CO{sub 2} that contacts the waste will react with the waste whenever the pH is above 10. In the 1990's, a substantial amount of data was collected on the concentration of CO{sub 2} in the off-gas of ventilated double-shell tanks at Hanford. This historic data was mined in order to determine the quantity of CO{sub 2} absorbed by the waste. The results of this data mining activity determined that tanks below approximately pH 10 (i.e., tank 241-AN-107) will show limited CO{sub 2} absorption, consistent with both the Hobbs model and the theory developed here. Two other tank with higher pH showed contrasting CO{sub 2} absorption. One showed substantial CO{sub 2} absorption, and the other showed minimal CO{sub 2} absorption despite the high waste pH in one tank, presumably because there was minimal contact between the waste surface and most of the air flow. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗