Oxidation Lifetime Modeling of 625 and 120 Foils After Long-term Exposure in Flowing Air + 10% ${\hbox {H}_2\hbox {O}}$ at 700 and 800 $^\circ$C

A model describing oxidation kinetics considering simultaneous oxidation and volatilization of external oxide scales was integrated with a CALPHAD-based coupled thermodynamic and kinetic approach to predict the oxidation-induced lifetime of foils of alloys 625 and 120. Long-term exposures in flowing air +10% H 2 O at 700 and 800 °C under two flow velocities were used to validate the modeling results. The time to a critical Cr concentration of 10 wt% at the oxide/alloy interface, t 10 , was shown to correlate with the breakdown of the Cr 2 O 3 scale for the studied experimental conditions. Finally, the modeling approach was extended to consider time-dependent oxidation and volatilization rate constants to develop a more appropriate lifetime criterion for microturbine recuperator foils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Temperature Oxidation Behavior of Fe- and Ni-Based Alloy Foils in Water Vapor at 850 °C

Operating temperatures above 700°C are desired to improve the efficiency of power generation systems such as microturbines. Therefore, the use of creep-resistant Ni-based or Fe-based alloys, which can form protective Cr2O3 and Al2O3 scales, is required. In this paper, Fe- and Ni-based alloy foils were oxidized in air + 10 % H2O for up to 3,000 h at 850°C to identify the most promising alloys. The thickness and chemical composition of the spinel oxide formed on top of the Cr2O3 scale varied between S3100, N08120 and N06230 alloy foils. In addition, the rate of Cr and Mn loss (spinel and Cr2O3 oxidation and volatilization) or Al loss (oxidation) and the dissolution of strengthening precipitates, were found to be a function of the nature of the formed oxide (Fe or Ni-rich spinel, Cr2O3, Al2O3). Alloys N06230 and alumina-forming austenitic (AFA) steels were found to be well-suited for the applications as microturbine recuperator foil materials up to 850°C.

Romedenne, Marie↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spectroscopic investigation of electron-beam-induced excitation and ionization of air [Abstract]

Time-dependent visible and near-ultraviolet emission spectroscopy was used to track the presence of excited and ionized states induced as an electron beam transited a cavity filled with air at low pressures. An electron beam was produced in vacuum using a Febetron pulsed-power generator modified to produce a peak voltage of 100 kV, a peak current of 4.5 kA, and a pulse width of 100 ns. The beam electrons then passed through thin anode and pressure foils and transited a cavity filled with dry air at either 0.1 Torr or 1 Torr, exciting and ionizing the air along the way. The spectral measurements were combined with information from electrical, interferometric, and imaging diagnostics to reveal different ionization dynamics for the two cases under study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Water Vapor on Lifetime of 625 and 120 Foils During Oxidation Between 650 and 800 °C

In this work, the oxidation behavior of alloy 625 and 120 foils was studied at 650, 700 and 800 °C in dry air and flowing air + 10% H 2 O up to 10,000 h (alloy 625) or 30,000 h (alloy 120). The effect of water vapor on Cr loss was investigated. Manganese and iron in the 120 foil induced faster Cr depletion in the foil and breakdown of the Cr 2 O 3 scale into Fe and Cr-rich oxide compared to the alloy 625 foil. In the latter case, the presence of Nb led to the formation of Nb and Cr-rich oxide after breakdown of the Cr 2 O 3 scale. Simultaneous Cr loss due to oxidation and volatilization of the Cr 2 O 3 oxide scale was predicted and compared to experimental Cr loss measurements for exposures up to 30,000 h.

36 MATERIALS SCIENCE↗

Measuring aerosol collection efficiency for the Bladewerx “New Speclon TM 5” and the older “Speclon TM 5” filter

Bladewerx TM LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon TM PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon TM filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. The LANL Aerosol Engineering Facility received air filter material from Bladewerx, referred to as “New Speclon 5” in this document, in order to distinguish from filter material that was previously received (referred to as “Speclon 5” in this document). In this document, the aerosol collection efficiency and airflow resistance (pressure drop) were measured for the New Speclon 5 filter material.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Impact of Oxidation-Induced Degradation On Materials Used in Hydrogen-Fired Microturbines

Hydrogen-fueled microturbines are being considered as part of the future green microgrid. However, the use of hydrogen as a fuel presents new challenges for selection and development of suitable high temperature materials for hydrogen combustion. The burning of hydrogen is expected to result in higher operating temperatures and higher than typically observed water vapor contents in exhaust gases versus burning natural gas. In the present work, foil specimens of various Fe- and Ni-based alloys were oxidized in air + 10 % H 2 O and air + 60% H 2 O for up to 5,000 h at 700 °C to simulate the exhaust atmosphere of natural gas and hydrogen-fueled microturbines. Here, the impact of alloy composition and water vapor content on the oxidation/ volatilization induced loss of wall thickness was experimentally evaluated. Enhanced external oxidation and volatilization of Cr 2 O 3 and Ti-doped Cr 2 O 3 scales was observed in air + 60% H 2 O compared to air + 10% H 2 O. No significant impact of the higher water vapor content was observed on Al 2 O 3 scales formed on Fe-based alumina forming alloys. Lifetime modeling was employed to predict the combined effects of water vapor content, gas flow rates, temperature and alloy composition on the oxidation-induced lifetime of the investigated materials.

36 MATERIALS SCIENCE↗

THE IMPACT OF OXIDATION-INDUCED DEGRADATION ON MATERIALS USED IN HYDROGEN-FIRED MICROTURBINES

Hydrogen-fueled microturbines are being considered as part of the future green microgrid. However, the use of hydrogen as a fuel presents new challenges for selection and development of suitable high temperature materials for hydrogen combustion. The burning of hydrogen is expected to result in higher operating temperatures and higher than typically observed water vapor contents in exhaust gases than after burning natural gas. In the present work, foil specimens of various Fe- and Ni-based alloys were oxidized in air + 10vol.% H2O and air + 60vol.% H2O for up to 5,000 h at 700 °C to simulate the exhaust atmosphere of natural gas and hydrogen-fueled microturbines. The impact of alloy composition and water vapor content on the oxidation/ volatilization induced loss of wall thickness was experimentally evaluated. Enhanced external oxidation and volatilization of Cr¬2O3 and Ti-doped Cr2O3 scales was observed in 60 % H2O compared to 10% H2O. No significant impact of the higher water vapor content was observed on Al2O3 scales formed on Fe-based alumina forming alloys. Lifetime modeling was employed to predict the combined effects of water vapor content, gas flow rates, temperature and alloy composition on the oxidation-induced lifetime of the investigated materials

Romedenne, Marie↗

Multi frame radiography of supersonic water jets interacting with a foil target

Pulsed-power-driven underwater electrical explosion of cylindrical or conical wire arrays produces supersonic water jets that emerge from a bath, propagating through the air above it. Interaction of these jets with solid targets may represent a new platform for attaining materials at high pressure (>1010 Pa) conditions in a university-scale laboratory. However, measurements of the internal structure of such jets and how they interact with targets are difficult optically due to large densities and density contrasts involved. We utilized multi-frame x-ray radiographic imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility to explore the water jet and its interaction with a 50 μm thick copper foil placed a few mm from the surface of water. The jet was generated with a ∼130 kA-amplitude current pulse of ∼450 ns rise time applied to a conical wire array. X-ray imaging revealed a droplet-type structure of the jet with an average density of <400 kg/m3 propagating with a velocity of ∼1400 m/s. Measurements of deformation and subsequent perforation of the target by the jet suggested pressures at the jet–target interface of ∼5 × 109 Pa. The results were compared to hydrodynamic simulations for better understanding of the jet parameters and their interaction with the foil target. These results can be used in future research to optimize the platform, and extend it to larger jet velocities in the case of higher driving currents supplied to the wire array.

Physics↗

Process Development of the Vaporizing Foil Actuator Welding Technique

The industrial focus on continuous improvement for products is leading design engineers to consider multi-material design concepts more frequently. The design concepts use the advantages of each material while simultaneously minimizing the drawbacks. It also allows for the overall weight of the products to be reduced. Some traditional joining methods, though, struggle to join dissimilar material combinations. A technique known as vaporizing foil actuator welding, which was developed around ten years ago, is a solid-state joining method that has the potential to overcome the barriers to dissimilar material joining. The biggest drawbacks of vaporizing foil actuator welding are that it is still exclusively used in laboratory settings and early in the technology development process. As such, there is not enough confidence in the process for it to be transitioned to manufacturing environments yet. This work begins by analyzing the current state of the technology and identifying a roadmap to achieve a transition to manufacturing. The analysis found that increased confidence in the technology requires sample to sample repeatability to be improved. Beyond that, the process also needs to be fully automated before it can be considered as a viable technique for mass production. In order to further develop the technique, a fully automated work cell was constructed. By removing the human element from the process, this cell helped identify iii the aspects which contribute to process variability. The positioning of the vaporizing foil actuator was identified as the most important factor in process stability. A small set of samples were made in the automated cell with the addition of one component epoxy adhesive around the perimeter of the weld. These samples showed improved process repeatability compared with the samples made without adhesive. This indicates that small amounts of adhesive may be critical in using the process in industrial settings. Additionally, work was performed with manual positioning and adhesive dispensing. This work found that a hybrid joint behaves like traditional weld bonding, where the addition of adhesive makes the joint stronger than if either of the two joining methods were used on their own. To realize this performance with vaporizing foil actuator welding, though, the adhesive needs to be protected from burning during the rapid compression of air during the impact process.

36 MATERIALS SCIENCE↗

Development of copper thiolate organometallic compound as thermal sensitive coating for energy storage system safety

Safety and reliability are primary concerns for the deployment of lithium-ion batteries, especially in electric vehicles (EV) and larger-scale energy storage systems (ESS). Current technology in battery management systems (BMS) includes cell voltage monitoring and positioning temperature sensors in selected locations. For a system with hundreds to thousands of individual batteries, single-point temperature monitoring is inadequate to detect hot spots and cell overheating, which could lead to thermal runaway. Here, we have developed a temperature-sensitive copper-thiol compound that can be directly coated onto battery pouch foils to enable early detection of thermal runaway. Upon reaching specific temperatures, this compound releases a sulfur-containing detectable gas, which can be identified using chemically specific gas sensors to trigger an early warning signal. Such a signal propagate through air offers broad signal coverage and enables a more comprehensive approach to large-area temperature monitoring. The Cu-ethanethiol coating is designed to release volatile gases when the substrate surface temperature exceeds 70 °C, with continuous outgassing as the temperature increases. The compound is composed of Cu, S, Cl, hydrocarbons and trace amounts of oxygen. Upon heating, the oxidation state of Cu(I) transitions to Cu (II), accompanied by gas release. Thermogravimetric analysis coupled with mass spectrometry correlated well with the onset of gas release temperature and emission of sulfur-containing volatile gases. Additionally, an acrylic overcoat is applied to enhance the adhesion of the thermally sensitive compound film to the battery pouch foil. This coating is expected to offer an additional safety layer for ESS, alerting possible thermal runaway events before a failure occurs, thereby allowing sufficient time to implement a mitigation plan.

Early warning systems↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

Evaluation of lithium as a tritium storage medium for betavoltaics

Lithium foils were demonstrated to absorb surrogate protium for tritium-powered betavoltaics. 20μm thick lithium foils were hole-punched from a ribbon of electrodeposited lithium on copper foil. The lithium foils were loaded with hydrogen in a custom Sievert apparatus where the pressure drop showed full hydriding at a hydrogen pressure of 2 bar and at all loading temperatures above the lithium melting point at 190, 200, 225, 250, and 300. Lithium hydride formation was confirmed with Raman spectroscopy after hydrogen loading. The kinetics of experimental hydride formation was compared to the diffusion-limited Mintz–Bloch model. While the Mintz–Bloch model showed good fit with the experimental loadings, the model overpredicted the loading kinetics starting at 250 °C and at higher temperatures. In conclusion, The overprediction was either caused by lithium hydride outgassing due to some reduction with some residual lithium hydroxide created from brief air exposure when sealing the lithium in the reactor or a transition from diffusion-limited hydride growth to surface or metal–hydride interface-limited hydride growth.

25 ENERGY STORAGE↗