Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air source heat pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Source Heat Pumps in Cold Climates

This booklet is geared toward homeowners who want to learn about air source heat pumps and covers how the technology works, how it performs in various cold-climate environments, and NREL project highlights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Evaluating Air-Source Heat Pumps with Distributed Energy Resources in REopt

This training introduces attendees to NREL's REopt(R) web tool and its capabilities in evaluating air-source heat pumps (ASHP) alongside distributed energy resources (DERs). Designed for energy managers, facility operators, and sustainability managers, this session will explore how REopt provides techno-economic analysis to assess the financial viability of ASHP while identifying synergies with solar PV and battery storage. Participants will gain practical insights into using REopt to optimize energy strategies, reduce costs, and improve site resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump

Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗