Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air temperature, fast response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fast Response Temperature by airborne measurements over BNF

The original data were collected during the AAF Engineering Flights (AEF2025) in the vicinity of the ARM Bankhead National Forest (BNF) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/bnf ) in northwestern Alabama in March 2025. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at the public-use airport of Posey Field, Alabama (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from March 9 through March 24, 2025. The ArcticShark UAS performed nine flights, including eight research flights over the AMF3 (BNF Main Site) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current data set were the fine wire thermocouple probe, the Aircraft Integrated Meteorological Measurement System (AIMMS-30), the Pitot-static system (part of UAS flight control), and the infrared gas analyzer sensor for H2O and CO2 (LI-840). All parameters used in temperature calculations (static pressure, True Air Speed, and absolute humidity in form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature, fast response↗

CHELAX-BNF: Fast Response Temperature by airborne measurements

The original data were collected on board the ARM Aerial Facility ArcticShark uncrewed aerial system (UAS; https://www.arm.gov/capabilities/observatories/aaf/uas ) during the “Characterizing HEterogeneous Land-Atmosphere eXchanges at BNF” field campaign (CHEAX-BNF; https://arm.gov/research/campaigns/aaf2025CHELAX-BNF ). The ARM Aerial Facility ArcticShark UAS was based at the public-use airport of Posey Field, AL (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from May 28 to June 23, 2025. The ArcticShark UAS performed 5 flights, including 4 research flights over the BNF Main Site (ARM Mobile Facility 3, https://arm.gov/capabilities/observatories/amf ) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration, and aerosol size distribution. The current data set presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current data set were the fine wire thermocouple probe, the Aircraft Integrated Meteorological Measurement System (AIMMS-30), the Pitot-static system (part of UAS flight control), and the infrared gas analyzer sensor for H2O and CO2 (LI-840). All parameters used in temperature calculations (static pressure, True Air Speed, and absolute humidity in the form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature, fast response↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Instrumentation in wind tunnels

Requirements in designing instrumentation systems and measurements of various physical quantities in wind tunnels are surveyed. Emphasis is given to sensors used for measuring pressure, temperature, and angle, and the measurements of air turbulence and boundary layers. Instrumentation in wind tunnels require accuracy, fast response, diversity and operational simplicity. Measurements of force, pressure, attitude angle, free flow, pressure distribution, and temperature are illustrated by a table, and a block diagram. The LDV (laser Doppler velocimeter) method for measuring air turbulence and flow velocity and measurement of skin friction and flow fields using laser holograms are discussed. The future potential of these techniques is studied.

Takashima, K.↗

Miniature Convection Cooled Plug-type Heat Flux Gauges

Tests and analysis of a new miniature plug-type heat flux gauge configuration are described. This gauge can simultaneously measure heat flux on two opposed active surfaces when heat flux levels are equal to or greater than about 0.2 MW/m(sup 2). The performance of this dual active surface gauge was investigated over a wide transient and steady heat flux and temperature range. The tests were performed by radiatively heating the front surface with an argon arc lamp while the back surface was convection cooled with air. Accuracy is about +20 percent. The gauge is responsive to fast heat flux transients and is designed to withstand the high temperature (1300 K), high pressure (15 MPa), erosive and corrosive environments in modern engines. This gauge can be used to measure heat flux on the surfaces of internally cooled apparatus such as turbine blades and combustors used in jet propulsion systems and on the surfaces of hypersonic vehicles. Heat flux measurement accuracy is not compromised when design considerations call for various size gauges to be fabricated into alloys of various shapes and properties. Significant gauge temperature reductions (120 K), which can lead to potential gauge durability improvement, were obtained when the gauges were air-cooled by forced convection.

Liebert, Curt H.↗

Transient liquid-crystal technique used to produce high-resolution convective heat-transfer-coefficient maps

In this transient technique the preheated isothermal model wall simulates the classic one-dimensional, semi-infinite wall heat transfer conduction problem. By knowing the temperature of the air flowing through the model, the initial temperature of the model wall, and the surface cooling rate measured at any location with time (using the fast-response liquid-crystal patterns recorded on video tape), the heat transfer coefficient can be calculated for the color isothermal pattern produced. Although the test was run transiently, the heat transfer coefficients are for the steady-state case. The upstream thermal boundary condition was considered to be isothermal. This transient liquid-crystal heat-transfer technique was used in a transient air tunnel in which a square-inlet, 3-to-1 exit transition duct was placed. The duct was preheated prior to allowing room temperature air to be suddenly drawn through it. The resulting isothermal contours on the duct surfaces were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the temperature and time data for all points on the duct surfaces during each test. The duct surfaces were uniformly heated using two heating systems: the first was an automatic temperature-controlled heater blanket completely surrounding the test duct like an oven, and the second was an internal hot-air loop through the inside of the test duct. The hot-air loop path was confined inside the test duct by insulated heat dams located at the inlet and exit ends of the test duct. A recirculating fan moved hot air into the duct inlet, through the duct, out of the duct exit, through the oven, and back to the duct inlet. The temperature nonuniformity of the test duct model wall was held very small. Test results are reported for two inlet Reynolds numbers of 200,000 and 1,150,000 (based on the square-inlet hydraulic diameter) and two free-stream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 20 percent (using a grid), which is typical of real engine conditions.

Hippensteele, Steven A.↗

Gear Lubrication and Cooling Experiment and Analysis

A gear tooth temperature analysis was performed using a finite element method combined with a calculated heat input, a calculated oil jet impingement depth, and estimated heat transfer coefficients for the different parts of the gear tooth that are oil cooled and air cooled. Experimental measurements of gear tooth average surface temperature and gear tooth instantaneous surface temperature were made with a fast response, infrared, radiometric microscope. Increasing oil pressure has a significant effect on both average surface temperature and peak surface temperature at loads above 1895 N/cm(1083 lb/in) and speeds of 10,000 and 7500 rpm. Both increasing speed (from 5000 to 10,000 rpm) at constant speed cause a significant rise in the average surface temperature and in the instantaneous peak surface temperatures on the gear teeth. The oil jet pressure required to provide the best cooling for gears is the pressure required to obtain full gear tooth impingement. Calculated results for gear tooth temperatures were close to experimental results for various oil jet impingement depths for identical operating conditions.

Townsend, D. P.↗

The NASA-ER2 meteorological measurement system: Instrumentaion, calibration and intercomparison results

The NASA ER-2 aircraft is used as a platform for high altitude atmospheric missions. The Meteorological Measurement System (MMS) was designed specifically for atmospheric research to provide accurate, fast response, in situ measurements of pressure, temperature, and the three dimensional wind vector. The MMS consists of three subsystems: an air motion sensing system to measure the velocity of the air with respect to the aircraft, a high resolution Inertial Navigation System (INS) to measure the velocity of the aircraft with respect to the Earth, and a Data Acquisition System, to sample, process and record the measured quantities. Details of each of these systems are given. The location of the MMS instrumentation is illustrated. The calibration of the MMS is discussed and results on an intercomparison of MMS measurements, Vaisala radiosonde observation and radar tracking data are given. An illustration of the MMS measurement of vertical wind is given.

Chan, K. Roland↗

Supersonic shock wave/vortex interaction

Although shock wave/vortex interaction is a basic and important fluid dynamics problem, very little research has been conducted on this topic. Therefore, a detailed experimental study of the interaction between a supersonic streamwise turbulent vortex and a shock wave was carried out at the Penn State Gas Dynamics Laboratory. A vortex is produced by replaceable swirl vanes located upstream of the throat of various converging-diverging nozzles. The supersonic vortex is then injected into either a coflowing supersonic stream or ambient air. The structure of the isolated vortex is investigated in a supersonic wind tunnel using miniature, fast-response, five-hole and total temperature probes and in a free jet using laser Doppler velocimetry. The cases tested have unit Reynolds numbers in excess of 25 million per meter, axial Mach numbers ranging from 2.5 to 4.0, and peak tangential Mach numbers from 0 (i.e., a pure jet) to about 0.7. The results show that the typical supersonic wake-like vortex consists of a non-isentropic, rotational core, where the reduced circulation distribution is self similar, and an outer isentropic, irrotational region. The vortex core is also a region of significant turbulent fluctuations. Radial profiles of turbulent kinetic energy and axial-tangential Reynolds stress are presented. The interactions between the vortex and both oblique and normal shock waves are investigated using nonintrusive optical diagnostics (i.e. schlieren, planar laser scattering, and laser Doppler velocimetry). Of the various types, two Mach 2.5 overexpanded-nozzle Mach disc interactions are examined in detail. Below a certain vortex strength, a 'weak' interaction exists in which the normal shock is perturbed locally into an unsteady 'bubble' shock near the vortex axis, but vortex breakdown (i.e., a stagnation point) does not occur. For stronger vortices, a random unsteady 'strong' interaction results that causes vortex breakdown. The vortex core reforms downstream of the rear stagnation point, and the reduced circulation distribution once again becomes self-similar in this region. A-new model of this interaction is proposed. Finally, a curve defining the approximate limits of supersonic vortex breakdown is presented.

Settles, G. S.↗

Field Micrometeorological Measurements, Process-Level Studies and Modeling of Methane and Carbon Dioxide Fluxes in a Boreal Wetland Ecosystem

The main instrumentation platform consisted of eddy correlation sensors mounted on a scaffold tower at a height of 4.2 m above the peat surface. The sensors were attached to a boom assembly which could be rotated into the prevailing winds. The boom assembly was mounted on a movable sled which, when extended, allowed sensors to be up to 2 m away from the scaffolding structure to minimize flow distortion. When retracted, the sensors could easily be installed, serviced or rotated. An electronic level with linear actuators allowed the sensors to be remotely levelled once the sled was extended. Two instrument arrays were installed. A primary (fast-response) array consisted of a three-dimensional sonic anemometer, a methane sensor (tunable diode laser spectrometer), a carbon dioxide/water vapor sensor, a fine wire thermocouple and a backup one-dimensional sonic anemometer. The secondary array consisted of a one-dimensional sonic anemometer, a fine wire thermocouple and a Krypton hygrometer. Descriptions of these sensors may be found in other reports (e.g., Verma; Suyker and Verma). Slow-response sensors provided supporting measurements including mean air temperature and humidity, mean horizontal windspeed and direction, incoming and reflected solar radiation, net radiation, incoming and reflected photosynthetically active radiation (PAR), soil heat flux, peat temperature, water-table elevation and precipitation. A data acquisition system (consisting of an IBM compatible microcomputer, amplifiers and a 16 bit analog-to-digital converter), housed in a small trailer, was used to record the fast response signals. These signals were low-pass filtered (using 8-pole Butterworth active filters with a 12.5 Hz cutoff frequency) and sampled at 25 Hz. Slow-response signals were sampled every 5 s using a network of CR21X (Campbell Scientific, Inc., Logan Utah) data loggers installed in the fen. All signals were averaged over 30-minute periods (runs).

Verma, S. B.↗

Thermal measurements for jets in disturbed and undisturbed crosswind conditions

A direct comparison is made of the thermal field properties for a low-disturbance and a high-disturbance level condition affecting the low-temperature air jets introduced into gas turbine combustor aft sections in order both to cool the high-temperature gases and quench the combustion reactions. Sixty-four fast-response thermocouples were simultaneously sampled and corrected for their time constant effect at a downstream plane close to the jet exit. Histograms formed from independent samples were sufficiently smooth to approximate a pdf.

Wark, Candace E.↗

Proposed fast-response oxygen monitoring and control system for the Langley 8-foot high-temperature tunnel

A fast-response oxygen monitoring and control system, based on a Y2O3-stabilized ZrO2 sensor, was developed and tested in the laboratory. The system is capable of maintaining oxygen concentration in the CH4-O2-air combustion product gases at 20.9 + or - 1.0 percent. If the oxygen concentration in the exhaust stream differs from that in normal air by 25 percent or more, an alarm signal is provided for automatic tunnel shutdown. The overall prototype system response time was reduced from about 1 sec in the original configuration to about 0.2 sec. The basis of operation and the results of laboratory tests of the system are described.

Singh, J. J.↗

Impacts of Wildfire Aerosols on Global Energy Budget and Climate: The Role of Climate Feedbacks

Aerosols emitted from wildfires could significantly affect global climate through perturbing global radiation balance. In this study, the Community Earth System Model with prescribed daily fire aerosol emissions is used to investigate fire aerosols’ impacts on global climate with emphasis on the role of climate feedbacks. The total global fire aerosol radiative effect (RE) is estimated to be -0.78 ± 0.29 W m -2 , which is mostly from shortwave RE due to aerosol–cloud interactions (REaci; -0.70 ± 0.20 W m -2 ). The associated global annual-mean surface air temperature (SAT) change ΔT is -0.64 ± 0.16 K with the largest reduction in the Arctic regions where the shortwave REaci is strong. Associated with the cooling, the Arctic sea ice is increased, which acts to reamplify the Arctic cooling through a positive ice-albedo feedback. The fast response (irrelevant to ΔT) tends to decrease surface latent heat flux into atmosphere in the tropics to balance strong atmospheric fire black carbon absorption, which reduces the precipitation in the tropical land regions (southern Africa and South America). The climate feedback processes (associated with ΔT) lead to a significant surface latent heat flux reduction over global ocean areas, which could explain most (~80%) of the global precipitation reduction. The precipitation significantly decreases in deep tropical regions (5°N) but increases in the Southern Hemisphere tropical ocean, which is associated with the southward shift of the intertropical convergence zone and the weakening of Southern Hemisphere Hadley cell. Such changes could partly compensate the interhemispheric temperature asymmetry induced by boreal forest fire aerosol indirect effects, through intensifying the cross-equator atmospheric heat transport.

54 ENVIRONMENTAL SCIENCES↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Relationship between wind, waves and radar backscatter

The aim of the research was to investigate the relationship between wind, waves, and radar backscatter from water surface. To this end, three field experiments with periods of 2 to 4 weeks were carried out during summer months in 1988, 1989 and 1990. For these periods, the University of Washington group provided (1) environmental parameters such as wind speed, wind stress, and atmospheric stratification through measurements of surface fluxes (of momentum, sensible heat and latent heat) and of air and water temperatures; and (2) wave height spectra including both the dominant waves and the short gravity-capillary waves. Surface flux measurements were performed by using our well tested instruments: a K-Gill twin propeller-vane anemometer and a fast response thermocouple psychrometer. Wave heights were measured by a resistance wire wave gauge. The University of Kansas group was responsible for the operation of the microwave radars.

Katsaros, Kristina B.↗

High-temperature catalyst for catalytic combustion and decomposition

A robust, high temperature mixed metal oxide catalyst for propellant composition, including high concentration hydrogen peroxide, and catalytic combustion, including methane air mixtures. The uses include target, space, and on-orbit propulsion systems and low-emission terrestrial power and gas generation. The catalyst system requires no special preheat apparatus or special sequencing to meet start-up requirements, enabling a fast overall response time. Start-up transients of less than 1 second have been demonstrated with catalyst bed and propellant temperatures as low as 50 degrees Fahrenheit. The catalyst system has consistently demonstrated high decomposition effeciency, extremely low decomposition roughness, and long operating life on multiple test particles.

Mays, Jeffrey A.↗

Climate responses in China to domestic and foreign aerosol changes due to clean air actions during 2013–2019

In recent years, to improve air quality, significant efforts have been made to reduce regional aerosols including China, Europe and North America, which have potential impacts on climate. In this study, fast and slow climate responses in China to changes in domestic and foreign anthropogenic emissions of aerosols and precursors from 2013 to 2019 are investigated using the Community Earth System Model version 1 (CESM1). Aerosol emissions changes, especially reductions in China, North America and Europe, during 2013–2019 resulted in surface air temperature increases across the Northern Hemisphere. Global aerosol changes induce a regional warming of 0.2 °C in China, equally contributed by domestic and foreign emissions changes. China’s domestic emission reductions lead to a regional average temperature rise of 0.1°C, primarily driven by rapid atmospheric adjustments over eastern China. Foreign aerosol changes, particularly reductions in North America and Europe, also contributed to a 0.1°C warming in China through slow oceanic processes. This warming in China induced by foreign aerosol changes is due to a teleconnection between the aerosol-induced anomalous regional warming in Eastern U.S.-North Atlantic Ocean-Europe and the downstream East Asian climate through anomalous wave trains propagation. The comparable influence of domestic and foreign aerosol changes on climate in China underscores the importance of international collaboration in climate mitigation endeavors.

54 ENVIRONMENTAL SCIENCES↗

Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983

A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

Fishman, Jack↗