At least 19 records

Regional Relative Risk, a Physics-Based Metric for Characterizing Airborne Infectious Disease Transmission

Airborne infectious disease transmission events occur over a wide range of spatial scales and can be an important means of disease transmission. Physics- and biology-based models can assist in predicting airborne transmission events, overall disease incidence, and disease control strategy efficacy. We describe a new theory that extends current approaches for the case in which an individual is infected by a single airborne particle, including the scenario in which numerous infectious particles are present in the air but only one causes infection. A single infectious particle can contain more than one pathogenic microorganism and be physically larger than the pathogen itself. This approach allows robust relative risk estimates even when there is wide variation in (i) individual exposures and (ii) the individual response to that exposure (the pathogen dose-response function can take any mathematical form and vary by individual). Based on this theory, we propose the regional relative risk—a new metric, distinct from the traditional relative risk metric, that compares the risk between two regions. In theory, these regions can range from individual rooms to large geographic areas. In this paper, we apply the regional relative risk metric to outdoor disease transmission events over spatial scales ranging from 50 m to 20 km, demonstrating that in many common cases minimal input information is required to use the metric. Also, we demonstrate that the model predictions are consistent with data from prior outbreaks. Future efforts could apply and validate this theory for other spatial scales, such as transmission within indoor environments. This work provides context for (i) the initial stages of an airborne disease outbreak and (ii) larger-scale disease spread, including unexpected low-probability disease “sparks” that potentially affect remote populations, a key practical issue in controlling airborne disease outbreaks.

54 ENVIRONMENTAL SCIENCES↗

Multiscale Airborne Infectious Disease Transmission

Airborne disease transmission is central to many scientific disciplines, including agriculture, veterinary biosafety, medicine, and public health. Legal and regulatory standards are in place to prevent agricultural, nosocomial, and community airborne disease transmission. However, the overall importance of the airborne pathway is underappreciated; e.g., the U.S. National Library of Medicine’s Medical Subjects Headings (MESH) thesaurus lacks an airborne disease transmission indexing term. This has practical consequences, as airborne precautions to control epidemic disease spread may not be taken when airborne transmission is important but unrecognized. Publishing clearer practical methodological guidelines for surveillance studies and disease outbreak evaluations could help address this situation. To inform future work, this paper highlights selected, well-established airborne transmission events, largely cases replicated in multiple, independently conducted scientific studies. Methodologies include field experiments, modeling, epidemiology studies, disease outbreak investigations, and mitigation studies. Collectively, this literature demonstrates that airborne viruses, bacteria, and fungal pathogens have the ability to cause disease in plants, animals, and humans over multiple distances, from near range (<5 m) to continental (>500 km) in scale. The plausibility and implications of undetected airborne disease transmission are discussed, including the notable underreporting of disease burdens for several airborne-transmitted diseases.

59 BASIC BIOLOGICAL SCIENCES↗

Control of airborne infectious disease in buildings: Evidence and research priorities

The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls-individually and in combination-on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Finally, improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.

60 APPLIED LIFE SCIENCES↗

Airborne infectious disease isolation units and method of making using prefabricated containers

In one embodiment, a prefabricated container is modified as a medical isolation room by replacing an original door with a clear front door. An intake louver and an adjustable damper are disposed at a lower part of the front end. An exhaust vent is disposed at an upper part of the back wall. An exhaust fan and a HEPA filter are coupled to the exhaust vent. Washable coverings cover interior sides of the container to provide washable, nonslip interior surfaces. The exhaust fan and the adjustable damper at the intake louver are controlled to produce in the medical isolation room a negative air pressure of at least about minus 0.01 inch of water gage (approximately 2.5 pascals) and a displacement ventilation exhaust flow rate through the exhaust vent of at least about 100 cubic feet per minute (cfm) greater than an intake flow rate through the intake louver.

Channell, Michael G.↗

Computational epidemiological tools for pandemic analysis, understanding, and response

This suite of software tools is being developed to enhance and analyze computational epidemiological models that incorporate realistic disease dynamics and human behavior, with the goal of supporting epidemic and pandemic response. Specifically, the tools enable data analysis, feature extraction, data synthesis, machine learning model development, and prediction of key public health outcomes, such as cases, hospitalizations, deaths, and behavioral responses, for airborne infectious diseases like COVID-19 and influenza.

Butts, David↗

A Case Study on Pathogen Transport, Deposition, Evaporation and Transmission: Linking High-Fidelity Computational Fluid Dynamics Simulations to Probability of Infection

A high-fidelity, low-Mach computational fluid dynamics simulation tool that includes evaporating droplets and variable-density turbulent flow coupling is well-suited to ascertain transmission probability and supports risk mitigation methods development for airborne infectious diseases such as COVID-19. A multi-physics large-eddy simulation-based paradigm is used to explore droplet and aerosol pathogen transport from a synthetic cough emanating from a kneeling humanoid. For an outdoor configuration that mimics the recent open-space social distance strategy of San Francisco, maximum primary droplet deposition distances are shown to approach 8.1 m in a moderate wind configuration with the aerosol plume transported in excess of 15 m. In quiescent conditions, the aerosol plume extends to approximately 4 m before the emanating pulsed jet becomes neutrally buoyant. A dose–response model, which is based on previous SARS coronavirus (SARS-CoV) data, is exercised on the high-fidelity aerosol transport database to establish relative risk at eighteen virtual receptor probe locations.

59 BASIC BIOLOGICAL SCIENCES↗

Reducing Risk With ASHRAE Standard 241

ASHRAE Standard 241’s requirements can make indoor spaces more resilient to the spread of airborne infectious diseases. Buildings that comply with ASHRAE Standard 241-2023, Control of Infectious Aerosols,1 will have the capacity to respond during times of elevated risk with systems that provide the necessary equivalent clean airflow for infection control (VECAi). To reduce risk effectively, these systems need to operate properly. This column explores Standard 241’s requirements for operations and maintenance in high-risk times (infection risk management mode or IRMM) and the importance of creating a Building Readiness Plan.

ashrae standard 241, Operations and Maintenance, b↗

Measured influence of overhead HVAC on exposure to airborne contaminants from simulated speaking in a meeting and a classroom

Tracer gas experiments were conducted in a 158 m 3 room with overhead supply diffusers to study dispersion of contaminants from simulated speaking in physically distanced meeting and classroom configurations. The room was contained within a 237 m 3 cell with open plenum return to the HVAC system. Heated manikins at desks and a researcher operating the tracer release apparatus presented 8-9 thermal plumes. Experiments were conducted under conditions of no forced air and neutral, cooled, or heated air supplied at 980-1100 cmh, and with/out 20% outdoor air. CO 2 was released at the head of one manikin in each experiment to simulate small (< 5 µm diameter) respiratory aerosols. The metric of exposure relative to perfectly mixed (ERM) is introduced to quantify impacts, based on measurements at manikin heads and at three heights in the center and corners of the room. Chilled or neutral supply air provided good mixing with ERMs close to one. Thermal stratification during heating produced higher ERMs at most manikins: 25% were ≥ 2.5 and the highest were > 5× perfectly mixed conditions. Operation of two within-zone air cleaners together moving ≥400 cmh vertically in the room provided enough mixing to mitigate elevated exposure variations.

54 ENVIRONMENTAL SCIENCES↗

Lab Home Testing of Residential Isolation Space Control to Minimize Infectious Disease Transmission in Existing Single-Family Homes

Existing evidence strongly suggests that viral infectious diseases can be transmitted via an airborne route across distances in indoor environments. Accordingly, the risk of airborne transmission within homes should be managed. The public health emergency associated with SARS-CoV-2 makes controlling airborne transmission of respired viruses in indoor environments critical, especially in poorly ventilated indoor environments. The effectiveness of engineering interventions requiring minor efforts that create a negative-pressure isolation zone (IZ) for a contagious person has yet to be tested for existing residential homes. To mitigate the risk of airborne virus transmission and maximize health protection for the population in existing single-family homes, the relative effectiveness of several control strategies are investigated in this report. While very high-efficiency MERV filtration, high ventilation rates, and other controls can help be effective, most occupants are not likely to have the time or means for advanced measures found in hospitals. This project focused on testing relatively simple efforts that utilize existing or easy to acquire materials and simple processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lab Home Testing of Residential Isolation Space Control to Minimize Infectious Disease Transmission in Existing Single-Family Homes

Existing evidence strongly suggests that viral infectious diseases can be transmitted via an airborne route across distances in indoor environments. Accordingly, the risk of airborne transmission within homes should be managed. The public health emergency associated with SARS-CoV-2 makes controlling airborne transmission of respired viruses in indoor environments critical, especially in poorly ventilated indoor environments. The effectiveness of engineering interventions requiring minor efforts that create a negative-pressure isolation zone (IZ) for a contagious person has yet to be tested for existing residential homes. To mitigate the risk of airborne virus transmission and maximize health protection for the population in existing single-family homes, the relative effectiveness of several control strategies are investigated in this report. While very high-efficiency MERV filtration, high ventilation rates, and other controls can help be effective, most occupants are not likely to have the time or means for advanced measures found in hospitals. This project focused on testing relatively simple efforts that utilize existing or easy to acquire materials and simple processes.

30 DIRECT ENERGY CONVERSION↗