Search NASA⌕ Search

SEARCH · Search NASA

Results for “Airflow configurations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

V/STOL gets a lift

The concept of a supersonic STOVL that could offer enhanced mission capability, survivability, operational flexibility, and utility over conventional aircraft is presented. Emphasis is currently on design studies, CFD work, small- and large-scale wind tunnel tests, simulation activities, flight experiments, and ground environment experiments. Propulsion system technology centers about the adaptation of existing or off-the-shelf engines. Concepts under study include separate flow in hover, gas-driven lift fan, and shaft-driven lift fan. NASA is examining generic valve and ducting configurations with airflow at ambient temperature and at temperatures up to 1000 F to gather pressure loss and heat transfer data. Advanced civil rotorcraft technologies examined include high-efficiency/dual-mode components such as torque converters; lightweight, quiet transmissions; and variable geometry power turbines; along with dual-function or convertible engines.

Biesiadny, Tom↗

Tests characterizing bioprocessor hardware for analytical modeling

The tests outlined in this paper were used to characterize the hardware components of the Salad Machine, a small NASA-developed bioprocessor. The data from these tests are presented, and the methods by which this data can be integrated into system mathematical models are briefly discussed. The subsystems and physical processes discussed include the lighting system, the air loop (condensing heat exchanger and the blower), heat transfer to the surroundings, and leakage. Through this effort it was learned that in the development of a test protocol, care should be taken to order the tests such that environmental parameters, particularly humidity, require as few large adjustments as possible. Sensor calibration and installation take a substantial amount of time, which should be built into the test schedule. Two properties were particularly hard to quantify: the air flow rate and the energy from the lighting system entering into the growth volume. Flow rate can be measured using the appropriate device for the system configuration and airflow. Lighting system radiation level was measured using three methods. The results of these methods varied substantially, putting off conclusive quantification of this value.

Gustavino, S.↗

Experimental evaluation of fuel preparation systems for an automotive gas turbine catalytic combustor

Spatial fuel distributions, degree of vaporization, pressure drop and air velocity profiles were measured. Three airblast injectors and an air-assist nozzle were tested. Air swirlers were used to improve the spatial fuel-air distribution. The work was done in a 12 cm tubular duct. Test conditions were: a pressure of 0.3 and 0.5 MPa, inlet air temperatures up to 800 K, air velocities of 10 20 m/s and fuel-air ratios up to 0.020. The fuel was Jet A. The best results were obtained with an airblast configuration that used multiple cones to provide high velocity air for atomization and also straightened the inlet airflow. With this configuration, uniform spatial fuel-air distributions were obtained with mixing lengths greater than 17.8 cm. In this length, vaporization of the fuel was 98.5 percent complete at an inlet air temperature of 700 K. The total pressure loss was 1.0 percent with a reference velocity of 20 m/s and 0.25 percent at 10m/s. The air velocity was uniform across the duct and no autoignition reactions were observed.

Tacina, R. R.↗

Experimental evaluation of fuel preparation systems for an automotive gas turbine catalytic combustor

Premixing-prevaporizing fuel systems were evaluated for use with a catalytic reactor for possible automotive gas turbine application. Spatial fuel-air distributions, degree of vaporization, pressure drop and air velocity profiles were measured. Three airblast injectors and an air-assist nozzle were tested. Air swirlers were used to improve the spatial fuel-air distribution. The work was done in a 12 cm tubular duct. Test conditions were: a pressure of 0.3 and 0.5 MPa, inlet air temperatures up to 800 K, air velocities of 10 and 20 m/s and fuel-air ratios up to 0.020. The fuel was Jet A. The best results were obtained with an air-blast configuration that used multiple cones to provide high velocity air for atomization and also straightened the inlet airflow. With this configuration, uniform spatial fuel-air distributions were obtained with mixing lengths greater than 17.8 cm. In this length, vaporization of the fuel was 98.5 percent complete at an inlet air temperature of 700 K. The total pressure loss was 1.0 percent with a reference velocity of 20 m/s and 0.25 percent at 10 m/s. The air velocity was uniform across the duct and no autoignition reactions were observed.

Tacina, R. R.↗

System and method for occupancy-driven register airflow control

An HVAC register airflow control system and an air flow control method are provided. A housing of the system is in fluid communication with an air source for supplying an airflow. The housing includes an air outlet to the enclosed space. A detection sensor detects occupancy information of the enclosed space. A controller generates a control signal based on the occupancy information and controls the shape change of a damper made of a shape memory material. The damper is controlled to switch between a first operative configuration for preventing the airflow from entering the enclosed space and a second operative configured for permitting the airflow to enter the enclosed space.

Wang, Ya↗

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗

Heat transfer augmentation of natural convection heat sink through notched fin design

A novel notched fin heat sink with a central opening is proposed in the present study to augment the heat transfer performance of the natural convection heat sink under horizontal configuration. Thermal and airflow behavior in the heat sinks were studied using both experimental and numerical methods. The results showed that the performance of the conventional heat sink can be enhanced by optimizing its fin design. The basic heat sink model provided a 17% reduction in thermal resistance when its fin height and fin spacing were doubled, and it was accompanied by a 21% increase in surface area. The heat sink with a notched fin design with a less surface area offered a 13% lower thermal resistance compared to the basic model by entraining more airflow into the interior fin region. Providing a central opening in the notched fin heat sink can further reduce the thermal resistance by about 13%. Further, this study also analyzed the influence of emissivity of the heat sink on natural convection conditions. The findings demonstrated that the heat sink with an emissivity of 0.9 can reduce the thermal resistance by nearly 23% compared to one with an emissivity of 0.15.

42 ENGINEERING↗

3-D CFD in a day - The laser digitizer project

The computation of airflow over complex configurations requires a complete description of the geometry. This can be obtained from CAD data, from blueprints, or from actual models. In any case, the time required is currently estimated at 4 to 6 months. It is proposed to shorten this time by a factor of 10 to 100 through the use of automated software, a fast, highly parallel computer and a three-dimensional laser digitizer. This device can provide (x,y,z) coordinates of surface points at rates exceeding 14,500/sec. Thus, it is possible to digitize an entire model in a few minutes. The accuracy of measurement on a flat white surface is better than 0.005 inches. Higher accuracy is available at higher cost. This work discusses the challenges which remain to be addressed. In particular, the surface point data need to be converted into a surface description, the surface description needs to be made into a surface grid, and the surface grid used to make a volume grid for the flow solver. Algorithms are kept in place or in mind for all of these problems. Integration of the more mature flow solution and visualization algorithms then allows generation of solution graphics directly from a wind tunnel model.

Merriam, Marshal↗

JT8D-100 turbofan engine, phase 1

The JT8D turbofan engine, widely used in short and medium range transport aircraft, contributes substantially to airport community noise. The jet noise is predominant in the JT8D engine and may be reduced in a modified engine, without loss of thrust, by increasing the airflow to reduce jet velocity. A configuration study evaluated the effects of fan airflow, fan pressure ratio, and bypass ratio on noise, thrust, and fuel comsumption. The cycle selected for the modified engine was based upon an increased diameter, single-stage fan and two additional core engine compressor stages, which replace the existing two-stage fan. Modifications were also made to the low pressure turbine to provide the increased torque required by the larger diameter fan. The resultant JT8D-100 engine models have the following characteristics at take-off thrust, compared to the current JT8D engine: Airflow and bypass ratio are increased, and fan pressure ratio and engine speed are reduced. The resultant engine is also longer, larger in diameter, and heavier than the JT8D base model, but these latter changes are compensated by the increased thrust and decreased fuel comsumption of the modified engine, thus providing the capability for maintaining the performance of the current JT8D-powered aircraft.

Source record↗

Air monitoring device

An air monitoring device (100) includes an outer casing (101) configured to receive an airflow (102) comprising particulate; a bore (103) located inside the outer casing (101); and a collection probe (104) located inside the outer casing (101), the collection probe (104) being configured such that there is a gap (105) between an exit of the bore (103) and an entrance of the collection probe (104), such that particulate in the airflow (102) having a diameter larger than a threshold flows through an interior of the collection probe (104).

Tissandier, Michael D.↗

Jet engine air intake system

An axisymmetric air intake system for a jet aircraft engine comprising a fixed cowl extending outwardly from the face of the engine, a centerbody coaxially disposed within the cowl, and an actuator for axially displacing the centerbody within the cowl was developed. The cowl and centerbody define a main airflow passageway therebetween, the configuration of which is changed by displacement of the centerbody. The centerbody includes a forwardly-located closeable air inlet which communicates with a centerbody auxiliary airflow passageway to provide auxiliary airflow to the engine. In one embodiment, a system for opening and closing the centerbody air inlet is provided by a dual-member centerbody, the forward member of which may be displaced axially with respect to the aft member.

Sorensen, N. E.↗

Poppet valve control of throat stability bypass to increase stable airflow range of a Mach 2.5. inlet with 60 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

An investigation of airflow over the aft portions of a variable sweep fighter configuration

An investigation of air flow over the aft portions of a variable sweep fighter aircraft configuration was made. Tests conducted in the unitary plan wind tunnel at Mach number 2.16 included measurements of forces, moments, and local static pressures as well as visual recordings of the air flow. An aerodynamic analytical prediction method was evaluated when used in data comparison at angles of attack of 0, 5, and 15 degrees. The results indicate that in supersonic flow the typical outboard located twin vertical tail arrangement tends to provide a more positive increment in normal-force on the afterbody fuselage and the horizontal tail than a single center-mounted vertical tail of similar planform shape. In addition, the results indicate that a method for aerodynamic analysis of wing-body-tail configurations currently available can provide reasonable estimates of pressure coefficient distributions on configurations in regions of complex supersonic flow. At this time, however, the available analytical method cannot adequately replace experimental wind tunnel tests for determining the supersonic flow environment of a given configuration.

Graves, E. B.↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗