Search NASA⌕ Search

SEARCH · Search NASA

Results for “Akaike information criterion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Choosing the optimal fit function: Comparison of the Akaike information criterion and the F-test

In many circumstances of data fitting one has to choose the optimal fitting function or model among several alternatives. Criteria or tests on which this decision is based are necessary and have to be well selected. In this preliminary analysis the application of the corrected Akaike information criterion is demonstrated considering the example of determining pharmacokinetic parameters for the blood serum time activity curves of {sup 111}In-labeled anti-CD66 antibody. Another model selection criterion, the F-test, is used for comparison. For the investigated data the corrected Akaike information criterion has proved to be an effective and efficient approach, applicable to nested and non-nested models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of error covariance structure on estimation of model averaging weights and predictive performance

When conducting model averaging for assessing groundwater conceptual model uncertainty, the averaging weights are often evaluated using model selection criteria such as AIC, AICc, BIC, and KIC (Akaike Information Criterion, Corrected Akaike Information Criterion, Bayesian Information Criterion, and Kashyap Information Criterion, respectively). However, this method often leads to an unrealistic situation in which the best model receives overwhelmingly large averaging weight (close to 100%), which cannot be justified by available data and knowledge. It was found in this study that this problem was caused by using the covariance matrix, CE, of measurement errors for estimating the negative log likelihood function common to all the model selection criteria. This problem can be resolved by using the covariance matrix, Cek, of total errors (including model errors and measurement errors) to account for the correlation between the total errors. An iterative two-stage method was developed in the context of maximum likelihood inverse modeling to iteratively infer the unknown Cek from the residuals during model calibration. The inferred Cek was then used in the evaluation of model selection criteria and model averaging weights. While this method was limited to serial data using time series techniques in this study, it can be extended to spatial data using geostatistical techniques. The method was first evaluated in a synthetic study and then applied to an experimental study, in which alternative surface complexation models were developed to simulate column experiments of uranium reactive transport. It was found that the total errors of the alternative models were temporally correlated due to the model errors. The iterative two-stage method using Cek resolved the problem that the best model receives 100% model averaging weight, and the resulting model averaging weights were supported by the calibration results and physical understanding of the alternative models. Using Cek obtained from the iterative two-stage method also improved predictive performance of the individual models and model averaging in both synthetic and experimental studies.

error correlation↗

Proton radius from electron scattering data

Background: The proton charge radius extracted from recent muonic hydrogen Lamb shift measurements is significantly smaller than that extracted from atomic hydrogen and electron scattering measurements. The discrepancy has become known as the proton radius puzzle. Purpose: In an attempt to understand the discrepancy, we review high-precision electron scattering results from Mainz, Jefferson Lab, Saskatoon and Stanford. Methods: We make use of stepwise regression techniques using the F-test as well as the Akaike information criterion to systematically determine the predictive variables to use for a given set and range of electron scattering data as well as to provide multivariate error estimates. Results: Starting with the precision, low four-momentum transfer (Q 2 ) data from Mainz (1980) and Saskatoon (1974), we find that a stepwise regression of the Maclaurin series using the F-test as well as the Akaike information criterion justify using a linear extrapolation which yields a value for the proton radius that is consistent with the result obtained from muonic hydrogen measurements. Applying the same Maclaurin series and statistical criteria to the 2014 Rosenbluth results on GE from Mainz, we again find that the stepwise regression tends to favor a radius consistent with the muonic hydrogen radius but produces results that are extremely sensitive to the range of data included in the fit. Making use of the high-Q 2 data on G E to select functions which extrapolate to high Q 2 , we find that a Pad´e (N = M = 1) statistical model works remarkably well, as does a dipole function with a 0.84 fm radius, G E (Q 2 ) = (1 + Q 2 /0.66 GeV 2 ) -2 . Conclusions: Rigorous applications of stepwise regression techniques and multivariate error estimates result in the extraction of a proton charge radius that is consistent with the muonic hydrogen result of 0.84 fm; either from linear extrapolation of the extreme low-Q 2 data or by use of the Pad´e approximant for extrapolation using a larger range of data. Thus, based on a purely statistical analysis of electron scattering data, we conclude that the electron scattering result and the muonic hydrogen result are consistent. Lastly, it is the atomic hydrogen results that are the outliers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular radiotherapy: The NUKFIT software for calculating the time-integrated activity coefficient

Purpose: Calculation of the time-integrated activity coefficient (residence time) is a crucial step in dosimetry for molecular radiotherapy. However, available software is deficient in that it is either not tailored for the use in molecular radiotherapy and/or does not include all required estimation methods. The aim of this work was therefore the development and programming of an algorithm which allows for an objective and reproducible determination of the time-integrated activity coefficient and its standard error.Methods: The algorithm includes the selection of a set of fitting functions from predefined sums of exponentials and the choice of an error model for the used data. To estimate the values of the adjustable parameters an objective function, depending on the data, the parameters of the error model, the fitting function and (if required and available) Bayesian information, is minimized. To increase reproducibility and user-friendliness the starting values are automatically determined using a combination of curve stripping and random search. Visual inspection, the coefficient of determination, the standard error of the fitted parameters, and the correlation matrix are provided to evaluate the quality of the fit. The functions which are most supported by the data are determined using the corrected Akaike information criterion. The time-integrated activity coefficient is estimated by analytically integrating the fitted functions. Its standard error is determined assuming Gaussian error propagation. The software was implemented using MATLAB.Results: To validate the proper implementation of the objective function and the fit functions, the results of NUKFIT and SAAM numerical, a commercially available software tool, were compared. The automatic search for starting values was successfully tested for reproducibility. The quality criteria applied in conjunction with the Akaike information criterion allowed the selection of suitable functions. Function fit parameters and their standard error estimated by using SAAM numerical and NUKFIT showed differences of <1%. The differences for the time-integrated activity coefficients were also <1% (standard error between 0.4% and 3%). In general, the application of the software is user-friendly and the results are mathematically correct and reproducible. An application of NUKFIT is presented for three different clinical examples.Conclusions: The software tool with its underlying methodology can be employed to objectively and reproducibly estimate the time integrated activity coefficient and its standard error for most time activity data in molecular radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Computational Information Criterion for Particle-Tracking with Sparse or Noisy Data

Traditional probabilistic methods for the simulation of advection-diffusion equations (ADEs) often overlook the entropic contribution of the discretization, e.g., the number of particles, within associated numerical methods. Many times, the gain in accuracy of a highly discretized numerical model is outweighed by its associated computational costs or the noise within the data. Herein, we address the question of how many particles are needed in a simulation to best approximate and estimate parameters in one-dimensional advective-diffusive transport. To do so, we use the well-known Akaike Information Criterion (AIC) and a recently-developed correction called the Computational Information Criterion (COMIC) to guide the model selection process. Random-walk and mass-transfer particle tracking methods are employed to solve the model equations at various levels of discretization. Numerical results demonstrate that the COMIC provides an optimal number of particles that can describe a more efficient model in terms of parameter estimation and model prediction compared to the model selected by the AIC even when the data is sparse or noisy, the sampling volume is not uniform throughout the physical domain, or the error distribution of the data is non-IID Gaussian.

97 MATHEMATICS AND COMPUTING↗

Non-singlet quark helicity $\mathrm{PDF}$s of the nucleon from pseudo-distributions

The non-singlet helicity quark parton distribution functions (PDFs) of the nucleon are determined from lattice QCD, by jointly leveraging pseudo-distributions and the distillation spatial smearing paradigm. A Lorentz decomposition of appropriately isolated space-like matrix elements reveals pseudo-distributions that contain information on the leading-twist helicity PDFs, as well as an invariant amplitude that induces an additional z 2 contamination of the leading-twist signal. An analysis of the short-distance behavior of the space-like matrix elements using matching coefficients computed to next-to-leading order (NLO) exposes the desired PDF up to this additional z 2 contamination. Due to the non-conservation of the axial current, we elect to isolate the helicity PDFs normalized by the nucleon axial charge at the same scale μ 2 . The leading-twist helicity PDFs as well as several sources of systematic error, including higher-twist effects, discretization errors, and the aforementioned z 2 contaminating amplitude are jointly determined by characterizing the computed pseudo-distribution in a basis of Jacobi polynomials. The Akaike Information Criterion is exploited to effectively average over distinct model parameterizations and cuts on the pseudo-distribution. Encouraging agreement is observed with recent global analyses of each non-singlet quark helicity PDF, notably a rather small non-singlet anti-quark helicity PDF for all quark momentum fractions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anomalies in global SMEFT analyses. A case study of first-row CKM unitarity

Recent developments in the Standard Model analysis of semileptonic charged-current processes involving light quarks have revealed ~ 3σ tensions in Cabibbo universality tests involving meson, neutron, and nuclear beta decays. In this paper, we explore beyond the Standard Model explanations of this so-called Cabibbo Angle Anomaly in the framework of the Standard Model Effective Field Theory (SMEFT), including not only low-energy charged current processes (‘L’), but also electroweak precision observables (‘EW’) and Drell-Yan collider processes (‘C’) that probe the same underlying physics across a broad range of energy scales. The resulting ‘CLEW’ framework not only allows one to test explanations of the Cabibbo Angle Anomaly, but is set up to provide near model-independent analyses with minimal assumptions on the flavor structure of the SMEFT operators. Besides the global analysis, we consider a large number of simpler scenarios, each with a subset of SMEFT operators, and investigate how much they improve upon the Standard Model fit. We find that the most favored scenarios, as judged by the Akaike Information Criterion, are those that involve right-handed charged currents. Additional interactions, namely oblique operators, terms modifying the Fermi constant, and operators involving right-handed neutral currents, play a role if the CDF determination of the W mass is included in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Capturing the spatial variability of noise levels based on a short-term monitoring campaign and comparing noise surfaces against personal exposures collected through a panel study

Highlights: • A Generalized Additive Model (GAM) was developed to generate noise exposure surfaces. • Noise data were collected based on short-term measurements in Toronto, Canada. • Various model specifications were tested in terms of the resulting predictions. • Predictions were validated against data from a panel and from a long-term campaign. • Models that involved manual adjustments resulted in more realistic surfaces. Environmental noise can cause important cardiovascular effects, stress and sleep disturbance. The development of appropriate methods to estimate noise exposure within a single urban area remains a challenging task, due to the presence of various transportation noise sources (road, rail, and aircraft). In this study, we developed a land-use regression (LUR) approach using a Generalized Additive Model (GAM) for LA{sub eq} (equivalent noise level) to capture the spatial variability of noise levels in Toronto, Canada. Four different model formulations were proposed based on continuous 20-min noise measurements at 92 sites and a leave one out cross-validation (LOOCV). Models where coefficients for variables considered as noise sources were forced to be positive, led to the development of more realistic exposure surfaces. Three different measures were used to assess the models; adjusted R{sup 2} (0.44–0.64), deviance (51−72%) and Akaike information criterion (AIC) (469.2–434.6). When comparing exposures derived from the four approaches to personal exposures from a panel study, we observed that all approaches performed very similarly, with values for the Fractional mean bias (FB), normalized mean square error (NMSE), and normalized absolute difference (NAD) very close to 0. Finally, we compared the noise surfaces with data collected from a previous campaign consisting of 1-week measurements at 200 fixed sites in Toronto and observed that the strongest correlations occurred between our predictions and measured noise levels along major roads and highway collectors. Our validation against long-term measurements and panel data demonstrates that manual modifications brought to the models were able to reduce bias in model predictions and achieve a wider range of exposures, comparable with measurement data.

54 ENVIRONMENTAL SCIENCES↗

Impact of Schedule Duration on Head and Neck Radiotherapy: Accelerated Tumor Repopulation Versus Compensatory Mucosal Proliferation

Purpose: To determine how modelled maximum tumor control rates, achievable without exceeding mucositis tolerance (tcp{sub max-early}) vary with schedule duration for head and neck squamous cell carcinoma (HNSCC). Methods and materials: Using maximum-likelihood techniques, we have fitted a range of tcp models to two HNSCC datasets (Withers' and British Institute of Radiology [BIR]), characterizing the dependence of tcp on duration and equivalent dose in 2 Gy fractions (EQD{sub 2}). Models likely to best describe future data have been selected using the Akaike information criterion (AIC) and its quasi-AIC extension to overdispersed data. Setting EQD{sub 2}s in the selected tcp models to levels just tolerable for mucositis, we have plotted tcp{sub max-early} against schedule duration. Results: While BIR dataset tcp fits describe dose levels isoeffective for tumor control as rising significantly with schedule protraction, indicative of accelerated tumor repopulation, repopulation terms in fits to Withers' dataset do not reach significance after accounting for overdispersion of the data. The tcp{sub max-early} curves calculated from tcp fits to the overall Withers' and BIR datasets rise by 8% and 0-4%, respectively, between 20 and 50 days duration; likewise, tcp{sub max-early} curves calculated for stage-specific cohorts also generally rise slowly with increasing duration. However none of the increases in tcp{sub max-early} calculated from the overall or stage-specific fits reach significance. Conclusions: Local control rates modeled for treatments which lie just within mucosal tolerance rise slowly but insignificantly with increasing schedule length. This finding suggests that whereas useful gains may be made by accelerating unnecessarily slow schedules until they approach early reaction tolerance, little is achieved by shortening schedules further while reducing doses to remain within mucosal tolerance, an approach that may slightly worsen outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET/CT imaging. These findings may inform future studies of functional lung avoidance using V/Q PET/CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a commercial automatic treatment planning system for prostate cancers

Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle{sup 3} radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle{sup 3} uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multimodel Predictive System for Carbon Dioxide Solubility in Saline Formation Waters

The prediction of carbon dioxide solubility in brine at conditions relevant to carbon sequestration (i.e., high temperature, pressure, and salt concentration (T-P-X)) is crucial when this technology is applied. Eleven mathematical models for predicting CO{sub 2} solubility in brine are compared and considered for inclusion in a multimodel predictive system. Model goodness of fit is evaluated over the temperature range 304–433 K, pressure range 74–500 bar, and salt concentration range 0–7 m (NaCl equivalent), using 173 published CO{sub 2} solubility measurements, particularly selected for those conditions. The performance of each model is assessed using various statistical methods, including the Akaike Information Criterion (AIC) and the Bayesian Information Criterion (BIC). Different models emerge as best fits for different subranges of the input conditions. A classification tree is generated using machine learning methods to predict the best-performing model under different T-P-X subranges, allowing development of a multimodel predictive system (MMoPS) that selects and applies the model expected to yield the most accurate CO{sub 2} solubility prediction. Statistical analysis of the MMoPS predictions, including a stratified 5-fold cross validation, shows that MMoPS outperforms each individual model and increases the overall accuracy of CO{sub 2} solubility prediction across the range of T-P-X conditions likely to be encountered in carbon sequestration applications.

54 ENVIRONMENTAL SCIENCES↗

Modeling Transient Soil Moisture Limitations on Microbial Carbon Respiration

Soil microorganisms are known to survive periods of aridity and to recover rapidly after wetting events, with the ability to transition between a dormant state in dry conditions and an active state in wet conditions. While this dynamic behavior has been previously incorporated into soil carbon respiration modeling frameworks, a direct comparison between this active-dormant transition mechanism and a more simplified first-order model has yet to be made. Here, we demonstrate the necessary extent of model complexity needed to reproduce transient carbon respiration rates obtained from a set of soil incubation experiments implemented over a range of soil depths and time intervals. Two approaches are tested, one uses simplified first-order kinetics, whereas the other employs a transition between active and dormant biomass. The performance of each model is evaluated using an Akaike Information Criterion (AIC) based on the accuracy with which they reproduce an experimental dataset consisting of two sets of time series soil incubations collected across a range of time and depth resolutions. Based on the AIC evaluation and model-data comparison, we conclude that a dormancy-enabled model featuring two distinct microbial strategists performs best for the majority of the soil profile (above 108 cm) for both high and low depth resolution and sampling frequency, despite the added parameters required. In contrast, the first-order model achieves better AIC scores when simulating our deepest soils (112–165 cm), where moisture fluctuations are expected to be less prevalent. These findings guide how and where we choose to apply more cost intensive models.

58 GEOSCIENCES↗

TESTING NONSTANDARD COSMOLOGICAL MODELS WITH SNLS3 SUPERNOVA DATA AND OTHER COSMOLOGICAL PROBES

We investigate the implications for some nonstandard cosmological models using data from the first three years of the Supernova Legacy Survey (SNLS3), assuming a spatially flat universe. A comparison between the constraints from the SNLS3 and those from other SN Ia samples, such as the ESSENCE, Union2, SDSS-II, and Constitution samples, is given and the effects of different light-curve fitters are considered. We find that analyzing SNe Ia with SALT2 or SALT or SiFTO can give consistent results and the tensions between different data sets and different light-curve fitters are obvious for fewer-free-parameters models. At the same time, we also study the constraints from SNLS3 along with data from the cosmic microwave background and the baryonic acoustic oscillations (CMB/BAO), and the latest Hubble parameter versus redshift (H(z)). Using model selection criteria such as {chi}{sup 2}/dof, goodness of fit, Akaike information criterion, and Bayesian information criterion, we find that, among all the cosmological models considered here ({Lambda}CDM, constant w, varying w, Dvali-Gabadadze-Porrati (DGP), modified polytropic Cardassian, and the generalized Chaplygin gas), the flat DGP is favored by SNLS3 alone. However, when additional CMB/BAO or H(z) constraints are included, this is no longer the case, and the flat {Lambda}CDM becomes preferred.

79 ASTRONOMY AND ASTROPHYSICS↗

THE GAMMA-RAY BURST HUBBLE DIAGRAM AND ITS IMPLICATIONS FOR COSMOLOGY

In this paper, we continue to build support for the proposal to use gamma-ray bursts (GRBs) as standard candles in constructing the Hubble diagram at redshifts beyond the current reach of Type Ia supernova observations. We confirm that correlations among certain spectral and light-curve features can indeed be used as luminosity indicators, and demonstrate from the most up-to-date GRB sample appropriate for this work that the {Lambda}CDM model optimized with these data is characterized by parameter values consistent with those in the concordance model. Specifically, we find that ({Omega}{sub m},{Omega}{sub {Lambda}}){approx}(0.25{sub -0.06}{sup +0.05}, 0.75{sub -0.05}{sup +0.06}), which are consistent, to within 1{sigma}, with (0.29, 0.71) obtained from the 9 yr Wilkinson Microwave Anisotropy Probe data. We also carry out a comparative analysis between {Lambda}CDM and the R{sub h} = ct universe and find that the optimal {Lambda}CDM model fits the GRB Hubble diagram with a reduced {chi}{sup 2}{sub dof}{approx}2.26, whereas the fit using R{sub h} = ct results in a {chi}{sup 2}{sub dof}{approx}2.14. In both cases, about 20% of the events lie at least 2{sigma} away from the best-fit curves, suggesting that either some contamination by non-standard GRB luminosities is unavoidable or that the errors and intrinsic scatter associated with the data are being underestimated. With these optimized fits, we use three statistical tools-the Akaike information criterion, the Kullback information criterion, and the Bayes information criterion-to show that, based on the GRB Hubble diagram, the likelihood of R{sub h} = ct being closer to the correct model is {approx}85%-96%, compared to {approx}4%-15% for {Lambda}CDM.

79 ASTRONOMY AND ASTROPHYSICS↗

The spatial structure of young stellar clusters. I. Subclusters

The clusters of young stars in massive star-forming regions show a wide range of sizes, morphologies, and numbers of stars. Their highly subclustered structures are revealed by the MYStIX project's sample of 31,754 young stars in nearby sites of star formation (regions at distances <3.6 kpc that contain at least one O-type star.) In 17 of the regions surveyed by MYStIX, we identify subclusters of young stars using finite mixture models—collections of isothermal ellipsoids that model individual subclusters. Maximum likelihood estimation is used to estimate the model parameters, and the Akaike Information Criterion is used to determine the number of subclusters. This procedure often successfully finds famous subclusters, such as the BN/KL complex behind the Orion Nebula Cluster and the KW-object complex in M 17. A catalog of 142 subclusters is presented, with 1-20 subclusters per region. The subcluster core radius distribution for this sample is peaked at 0.17 pc with a standard deviation of 0.43 dex, and subcluster core radius is negatively correlated with gas/dust absorption of the stars—a possible age effect. Based on the morphological arrangements of subclusters, we identify four classes of spatial structure: long chains of subclusters, clumpy structures, isolated clusters with a core-halo structure, and isolated clusters well fit by a single isothermal ellipsoid.

79 ASTRONOMY AND ASTROPHYSICS↗