Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ambient Weathering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Weather Data from BSEC Weather Stations

This dataset provides measurements of temperature, humidity, rainfall, wind, and sunlight at Ambient Weather and OttHydro stations across Baltimore city. These surface weather stations were deployed by the Baltimore Social-Environmental Collaborative (BSEC) Urban Integrated Field Laboratory (UIFL) project, funded by the Department of Energy (DOE). This dataset currently contains measurements from 2023 to June 2026 and will be periodically updated to include more stations and recent observations when available. Data File Information This dataset contains surface weather measurements data in comma-separated value (CSV) format and documents that describe the weather stations, locations, and measured parameters and units. data/[TIMEAVG]/[YEAR]/BSEC-[STATIONID]_[SENSORTYPE]_[TIMEAVG]_[YEAR].csv Surface weather measurements data in CSV format, where STATIONID indicates the weather station, SENSORTYPE is the type of weather station ('AWS' = Ambient Weather Station and 'OTT' = 'OttHydro Station'), TIMEAVG is time period for each entry (= daily, hourly, or 5min), and YEAR indicate the year in which the measurements were made. Example data file name: BSEC-AAC_AWS_hourly_2023.csv. documents/Station_Locations.csv This CSV file provides location information and measurement start date for each surface weather station. documents/Weather_Station_Descriptions.pdf This document provides detailed description of the instruments along with their setup and accuracy of measurement. documents/File_Contents.pdf This document describes the contents on the data files, including time notation, weather parameters and units of measurement. documents/site-metadata/[STATOINID]-metadata.pdf These PDF files provide information on weather station sites, including land cover characteristics, station mounting, and photographs. Each PDF file corresponds to one station, as indicated by STATIONID.

Ambient Weather Stations↗

Weather Data from BSEC Weather Stations

This dataset provides hourly measurements of temperature, humidity, rainfall, wind, and sunlight at Ambient Weather and OttHydro stations across Baltimore city. These surface weather stations were deployed by the Baltimore Social-Environmental Collaborative (BSEC) Urban Integrated Field Laboratory (UIFL) project, funded by the Department of Energy (DOE). This dataset will be periodically updated to include more stations and recent observations when available. Data File Information This dataset contains surface weather measurements data in comma-separated value (CSV) format and documents that describe the weather stations, locations, and measured parameters and units. data/BSEC-[STATIONID]_[SENSORTYPE]_hourly_[YEAR].csv Surface weather measurements data in CSV format, where STATIONID indicates the weather station, SENSORTYPE is the type of weather station ('AWS' = Ambient Weather Station and 'OTT' = 'OttHydro Station'), and YEAR indicate the year in which the measurements were made. Example data file name: BSEC-AAC_AWS_hourly_2023.csv. documents/Station_Locations.csv This CSV file provides location information and measurement start date for each surface weather station. documents/Weather_Station_Descriptions.pdf This document provides detailed description of the instruments along with their setup and accuracy of measurement. documents/File_Parameters.pdf This document describes the surface weather parameters and units of measurement.

Ambient Weather Stations↗

Initial Atmospheric Transport of Particles

A new version of the Initial Atmospheric Transport (IAT) model has been developed. This report fully characterizes the new model. IAT is designed to model heat release into the atmosphere that contains contaminated particles. The heat release forms a buoyant puff or plume. Buoyancy is quickly dissipated in 10's to 100's of seconds through drag and entrainment of ambient air. The final location of contaminant particles in the atmosphere after dissipation of abnormal heat is an important input to long term transportation codes such as the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) code. Ultimately the settling of contaminants after long term transport provides a basis for estimating health consequences. In comparison to the old version, the new model includes explicit simulation of particles, newly formulated equations of motion for a rising puff, and a new plume model. The plume model releases many instances of a single puff along a single trajectory in a way that balances energy released over a longer period than would be appropriate for a single puff. The puff model has additions for vorticity, turbulence, virtual mass, drag, and entrainment. The particle model leads to direct interfacing between IAT and the long-term transport code HYSPLIT. Previously, particle locations were given a pattern based on IAT's puff trajectory with no particle simulation. Now, particles are explicitly simulated, and 3-D spatial distributions of particles are output based on final positions. Ballistic particles are thrown outward at high velocity from explosive events and tend to hit the ground before the end of the simulation. Non-ballistic particles tend to get pulled into the rising puff s ring of vorticity with some escaping to ambient conditions as buoyant energy dissipates. A new model verification and validation effort was made for the new plume model. The Wallops Island Solid Rocket Propellant (SRP) fire plume was extracted to a 3-D transient dataset. After calibration, the model performs better than previous single puff attempts. Even so, error levels in the process used to estimate location and ambient weather conditions approach 30%. This leads to the conclusion that unplanned photogrammetry evaluations of the IAT model are useful but not sufficiently accurate to quantify model parameters. Like previous attempts, the vertical motion entrainment parameters come out much too high in comparison to values for other studies in the literature. It is suspected that a new model of shear entrainment would alleviate this problem. Unfortunately, IAT already has more calibration parameters than the data comparisons thus far can resolve with statistical certainty. This underscores the need to verify and validate the IAT model using detailed CFD studies that allow ideal statistical comparison with the IAT model for hundreds of cases. Even so, validation by comparison to carefully planned experiments (i.e. with acceptable error levels) is also necessary because the dynamics of entrainment are at a sub-grid level for CFD. Though better validation and verification are most important, many new enhancements are still envisioned for future IAT development. These include particle rain out due to condensation and agglomeration of water, direct connection to the North American Mesoscale (NAM) weather dataset, dynamic weather conditions, including ambient particle entrainment into the puff, and detrainment at the puff to ambient mixing interface. In general, including detailed aerosol dynamics is the greatest coming challenge which will require an entire new sub-model in IAT. This is very important if contaminant particles change in such a way that they increase or decrease in their potential harm to the environment.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-001 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-001), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-002 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-002), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-004 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an Application Programming Interface (API) key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-004), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

EARTH SCIENCE > ATMOSPHERE > AEROSOLS > PARTICULAT↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Considerations for realistic atmospheric environments: An application to corrosion testing

Measured salt compositions in dust collected over roughly the last decade from surfaces of in-service stainless-steel alloys at four locations around the United States are presented, along with the predicted brine compositions that would result from deliquescence of these salts. The salt compositions vary greatly from ASTM seawater and from laboratory salts (i.e., NaCl or MgCl 2 ) commonly used on corrosion testing. The salts contained relatively high amounts of sulfates and nitrates, evolved to basic pH values, and exhibited deliquescence relative humidity values (RH) higher than seawater. Additionally, inert dust in components were quantified and considerations for laboratory testing are presented. The observed dust compositions are discussed in terms of the potential corrosion behavior and are compared to commonly used accelerated testing protocols. Finally, ambient weather conditions and their influence on diurnal fluctuations in temperature (T) and RH on heated metal surfaces are evaluated and a relevant diurnal cycle for laboratory testing a heated surface has been developed. Suggestions for future accelerated tests are proposed that include exploration of the effects of inert dust particles on atmospheric corrosion, chemistry considerations, and realistic diurnal fluctuations in T and RH. Understanding mechanisms in both realistic and accelerated environments will allow development of a corrosion factor (i.e., scaling factor) for the extrapolation of laboratory-scale test results to real world applications.

54 ENVIRONMENTAL SCIENCES↗

Thermally unstable roosts influence winter torpor patterns in a threatened bat species

Abstract Many hibernating bats in thermally stable, subterranean roosts have experienced precipitous declines from white-nose syndrome (WNS). However, some WNS-affected species also use thermally unstable roosts during winter that may impact their torpor patterns and WNS susceptibility. From November to March 2017–19, we used temperature-sensitive transmitters to document winter torpor patterns of tricolored bats (Perimyotis subflavus) using thermally unstable roosts in the upper Coastal Plain of South Carolina. Daily mean roost temperature was 12.9 ± 4.9°C SD in bridges and 11.0 ± 4.6°C in accessible cavities with daily fluctuations of 4.8 ± 2°C in bridges and 4.0 ± 1.9°C in accessible cavities and maximum fluctuations of 13.8 and 10.5°C, respectively. Mean torpor bout duration was 2.7 ± 2.8 days and was negatively related to ambient temperature and positively related to precipitation. Bats maintained non-random arousal patterns focused near dusk and were active on 33.6% of tracked days. Fifty-one percent of arousals contained passive rewarming. Normothermic bout duration, general activity and activity away from the roost were positively related to ambient temperature, and activity away from the roost was negatively related to barometric pressure. Our results suggest ambient weather conditions influence winter torpor patterns of tricolored bats using thermally unstable roosts. Short torpor bout durations and potential nighttime foraging during winter by tricolored bats in thermally unstable roosts contrasts with behaviors of tricolored bats in thermally stable roosts. Therefore, tricolored bat using thermally unstable roosts may be less susceptible to WNS. More broadly, these results highlight the importance of understanding the effect of roost thermal stability on winter torpor patterns and the physiological flexibility of broadly distributed hibernating species.

Biodiversity & Conservation↗

Effect of Dual Environment Aging on Flexible Polyurethane Based Adhesive

Abstract Environmental degradation of adhesives naturally increases with the intensity of the ambient weathering agents involved. During service life, these materials are never subjected to a constant environmental loading. Real-time applications expose the material to multiple weather conditions, ranging from dry to humid or fully wet conditions. While some understanding exists about aging environments in isolation, we intend to investigate the effect of multiple environments on the constitutive behavior of the materials in question. The extent of damage can be accessed by analyzing the changes in constitutive behavior and toughness of aged material. Therefore, this aging experiment was designed around two-way aging regimes involving combinations of thermo-oxidation, hydrolytic and hygrothermal aging environments. We selected a polyurethane based flexible adhesive which is commonly used in the automotive industry as a glass sealant. The aged specimens were subjected to uniaxial tensile tests, and variation in material toughness and constitutive behavior was analyzed to ascertain the mechanics involved in the case of each environmental exposure. We outlined how different environments affect the material in isolation and how they interact with other weathering conditions. This study will help better understand and model the damage mechanics involved in exposure to multiple environmental conditions.

Shaafaey, Mamoon↗

SoyFACE Fumigation Data Files

This data set is related to the SoyFACE experiments, which are open-air agricultural climate change experiments that have been conducted since 2001. The fumigation experiments take place at the SoyFACE farm and facility in Champaign County, Illinois during the growing season of each year, typically between June and October. - The "SoyFACE Plot Information 2001 to 2021" file contains information about each year of the SoyFACE experiments, including the fumigation treatment type (CO2, O3, or a combination treatment), the crop species, the plots (also referred to as 'rings' and labeled with numbers between 2 and 31) used in each experiment, important experiment dates, and the target concentration levels or 'setpoints' for CO2 and O3 in each experiment. - This data set includes files with minute readings of the fumigation levels ( "SoyFACE 1-Minute Fumigation Data Files" folder) from the SoyFACE experiments. The "Soyface 1-Minute Fumigation Data Files" folder contains sub-folders for each year of the experiments, each of which contains sub-folders for each ring used in that year's experiments. This data set also includes hourly data files for the fumigation experiments ( "SoyFACE Hourly Fumigation Data Files" folder) created from the 1-minute files, and hourly ambient/weather data files for each year of the experiments ( "Hourly Weather and Ambient Data Files" folder). The ambient CO2 and O3 data are collected at SoyFACE, and the weather data are collected from the SURFRAD and WARM weather stations located near the SoyFACE farm. - The "Fumigation Target Percentages" file shows how much of the time the CO2 and O3 fumigation levels are within a 10 or 20 percent margin of the target levels when the fumigation system is turned on. - The "Matlab Files" folder contains custom code (Aspray, E.K.) that was used to clean the "SoyFACE 1-Minute Fumigation Data" files and to generate the "SoyFACE Hourly Fumigation Data" and "Fumigation Target Percentages" files. Code information can be found in the "SoyFACE Hourly Fumigation Data Explanation" file. - Finally, the " * Explanation" files contain information about the column names, units of measurement, and other pertinent information for each data file. * NOTE: We have identified some files in the “SoyFACE 1-Minute Fumigation Data Files” folder in our SoyFACE data set submission that were not downloaded properly - the files were present in the folder, but the actual files were empty. V3 ensures that there are no longer any empty files in the data set.

agricultural↗

Two decades of fumigation data from the Soybean Free Air Concentration Enrichment facility

Abstract The Soybean Free Air Concentration Enrichment (SoyFACE) facility is the longest running open-air carbon dioxide and ozone enrichment facility in the world. For over two decades, soybean, maize, and other crops have been exposed to the elevated carbon dioxide and ozone concentrations anticipated for late this century. The facility, located in East Central Illinois, USA, exposes crops to different atmospheric concentrations in replicated octagonal ~280 m 2 Free Air Concentration Enrichment (FACE) treatment plots. Each FACE plot is paired with an untreated control (ambient) plot. The experiment provides important ground truth data for predicting future crop productivity. Fumigation data from SoyFACE were collected every four seconds throughout each growing season for over two decades. Here, we organize, quality control, and collate 20 years of data to facilitate trend analysis and crop modeling efforts. This paper provides the rationale for and a description of the SoyFACE experiments, along with a summary of the fumigation data and collation process, weather and ambient data collection procedures, and explanations of air pollution metrics and calculations.

60 APPLIED LIFE SCIENCES↗

Effect of multiple calcination cycles on CO 2 capture efficiency during carbonation of MgO in a mineral looping process

Magnesium oxide (MgO) is considered as a potential sorbent for direct air capture of carbon dioxide in a looping process. Previous research on mineral looping for carbon capture from flue gas using MgO has shown deactivation of the sorbent with repeated cycles but repeated cycling for carbonation at ambient conditions has not been yet investigated. Here, we tested three cycles of carbonation for MgO nano-scale powders with different starting surface area. We find that carbonation efficiency is higher at higher surface area. No decrease in carbonation efficiency was observed with cycling, instead we find that carbonation efficiency and surface area are stable or even increasing with cycling. Based on our experimental data, we hypothesize that the carbonation in presence of relative humidity leads to first hydration of MgO, leading to formation of brucite (Mg(OH) 2 ). This formation of Mg(OH) 2 is a volume-increasing reaction, which leads to fracturing of MgO particles and results in an increase in surface area. We observed formation of amorphous and crystalline hydrated carbonates. The crystalline phase observed was nesquehonite (MgCO 3 ⋅ 3H 2 O). Our results show that MgO does not show any deactivation with repeated cycling for carbon capture at ambient conditions and in the presence of humidity. These findings therefore indicate that MgO is a suitable candidate as sorbent material for direct air capture of carbon dioxide.

Ambient weathering↗

Machine Learning-Driven Reliability Estimation of PV Inverters Considering Alert-Ambient Variability

Weather-induced spatio-temporal degradation limits outdoor PV inverter lifetime and reliability, necessitating advanced data analysis. This study employs a top-down, data-driven approach utilizing multiple machine learning (ML) algorithms to estimate inverter reliability in a 1.4 MW PV power plant, considering factors such as irradiance, humidity, temperature, time of day, and weather conditions. An extensive alert dataset from 17 identical inverters, including alert types, propagation, and frequency, reveals significant correlations with environmental factors and inverter output power, enabling the construction of a performance reliability model. Dual-stage supervised-ML models are evaluated for accuracy, with the ‘classification-regression’ model by an artificial neural network (ANN) tested on the averaged “Alert-Ambient” dataset, which is outperformed by ‘clustering-regression’ models using random forest (RF) and K-Nearest Neighbors (KNN) on individual inverter datasets. K-means clustering applies principal component analysis to reduce dimensions, achieving improved accuracy beyond the 80% achieved by ANN on the averaged dataset. Second-stage regression estimates inverter reliability with a mean square error of 0.0195 on the averaged dataset and as low as 0.002 on individual inverter datasets using RF. Furthermore, these findings highlight the method's suitability for estimating PV inverter output reliability under ambient conditions, essential for digital twin development and related applications.

14 SOLAR ENERGY↗

Thermal Constraint Violations as a Result of Ambient Adjusted Transmission Line Ratings

Ambient Adjusted Ratings allow transmission line current ratings to be increased above static ratings while requiring minimal weather monitoring. However, Ambient Adjusted Ratings are still contingent on static parameters that may not match real world conditions. This poster examines how simulation methods can estimate the extent to which using Ambient Adjusted Ratings could result in the violation of a transmission line's thermal constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Screening Analysis of CO2 Removal Through Enhanced Weathering

Terrestrial enhanced weathering has emerged as a technology of interest due to its simplicity, low energy requirement, and potentially low capital investment requirement. Due to the novelty of this technology, there is limited literature exploring the techno-economics of the process. This presentation reports on a screening techno-economic analysis that examines the impact of key factors that influence terrestrial enhanced weathering performance and cost. Two cases are considered for analysis, based on the material used: (1) Naturally occurring mined igneous rock (2) Industrial waste materials (like biomass ash or cement kiln dust) The analysis considers locating the terrestrial enhanced weathering system in the Midwestern United States, because of proximity to alkaline materials, availability of farmland, and appropriate ambient conditions for weathering. For the igneous rock case, the size of the system is based on the average amount of igneous rock available from a single mine—250,000 tonnes/year. For the industrial waste case, the size of the system is based on the amount of suitable waste material produced by an industrial hub—150,000 tonnes/year.

Leptinsky, Sarah↗

Enhanced Weathering Screening Techno-Economic Analysis

This presentation reports on a screening techno-economic analysis that examines the impact of key factors that influence terrestrial enhanced weathering performance and cost. Two cases are considered for analysis based on the material used: (1) Naturally occurring mined igneous rock (2) Industrial waste materials (like biomass ash or cement kiln dust) The analysis considers locating the terrestrial enhanced weathering system in the Midwestern United States, because of proximity to alkaline materials, availability of farmland, and appropriate ambient conditions for weathering. For the igneous rock case, the size of the system is based on the average amount of igneous rock available from a single mine—250,000 tonnes/year. For the industrial waste case, the size of the system is based on the amount of suitable waste material produced by an industrial hub—150,000 tonnes/year.

Leptinsky, Sarah↗