Search NASA⌕ Search

SEARCH · Search NASA

Results for “Amplifiers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Amplifier Output Power, Gain, Efficiency, and Bandwidth: A Comparative Study of GaN HEMT MMIC Multi-Stage Power Amplifiers versus Distributed Power Amplifiers

In this paper we present first, the results of a study conducted to investigate the microwave performance of a wideband (25-31 GHz) GaN MMIC distributed high power amplifier (HPA). Second, we compare and contrast the above performance with that of an alternate architecture that relies on two HPAs to provide contiguous 25-31 GHz coverage. The two HPAs operate across 25-28 GHz and 27-31 GHz, respectively, and can be switched in and out depending on the need at any given time. The parameters investigated includes the output power, gain, power added efficiency, bandwidth, RMS error vector magnitude for offset-QPSK, 8PSK, 16APSK, and 32 APSK waveforms, 3rd-order intermodulation distortion products, noise figure, and single sideband phase noise.

MMIC↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

Performance of a Kinetic Inductance Traveling-Wave Parametric Amplifier at 4 Kelvin: Toward an Alternative to Semiconductor Amplifiers

Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we present an amplification chain consisting of a kinetic inductance traveling-wave parametric amplifier (KITWPA) placed at 4 K, followed by a HEMT placed at 70 K, and demonstrate a chain-added noise $T_Σ$ = 6.3 ± 0.5 K between 3.5 and 5.5 GHz. While, in principle, any parametric amplifier can be quantum limited even at 4 K, in practice we find the performance of the KITWPA to be limited by the temperature of its inputs and by an excess of noise $T_{ex}$ = 1.9 K. In this work, the dissipation of the rf pump of the KITWPA constitutes the main power load at 4 K and is about 1% that of a HEMT. These combined noise and power dissipation values pave the way for the use of the KITWPA as a replacement for semiconductor amplifiers.

97 MATHEMATICS AND COMPUTING↗

Design of an optical amplifier for amplified OSC in IOTA facility at Fermilab

Optical stochastic cooling (OSC) is a cutting-edge beam cooling technology to reduce, control the 3 dimensional spread and the motion of particle beams. It has recently been successfully, experimentally, demonstrated in Fermilab's IOTA storage ring, marking a major step forward in beam cooling. OSC has the potential to significantly improve both the performance and flexibility as a beam cooling system. One promising way to boost OSC performance is by adding a high-gain optical amplifier. However, this amplifier must be carefully designed to meet the specific constraints of the OSC system. A major challenge lies in the limited optical delay, which is just 6 mm for the case of IOTA, set by the beam bypass, restricts us to use a short-length gain medium. This, along with IOTA’s high repetition rate and the relatively long duration of the optical pulses, limits the peak power available for the pump laser without damaging the crystal, which is crucial for achieving strong nonlinear gain. Additionally, it's essential to preserve the phase coherence of the undulator radiation during amplification, which further complicates the amplifier design. This report details a specialized amplifier setup that addresses these challenges, includes simulations of the integrated system, and summarizes the latest experimental progress and results.

Mondal, Abhishek [Fermilab]↗

Fluid amplifier state of the art. volume i- research and development - fluid amplifiers and logic

The report surveys the current state-of-the-art of fluid amplifiers including both theoretical and practical aspects of devices having no mechanically moving parts. It is based on a complete review of the published literature (with an extensive bibliography), information obtained from 20 organizations involved in fluid amplifier development, and work performed by the General Electric Company. Specific areas covered are design techniques, both analytical and experimental; typical elements and assemblies; applications, both now in use and contemplated; fabrication techniques; and instrumentation. The report concludes that, although simple applications are now being made, the fluid amplifier field is still in the early development stage. There continues to be a basis for optimism for space applications requiring extreme environmental tolerance, long life, or the elimination of fluid system interfaces. Specialized military, and commercial applications also look promising. Work now under way should provide a better understanding of the design of devices and increase the number of useful applications.

FLUID AMPLIFICATION↗

Amplified spontaneous emission measurement of a line-narrowed, tunable, Ti:Al2O3 amplifier using rubidium absorption

Amplified spontaneous emission, ASE, generated by a Ti:Al2O3 laser amplifier has been measured as a function of pump energy, and thus gain, using the atomic absorption of rubidium, Rb, gas at 0.780 micron. By tuning the Ti:Al2O3 laser, the Rb cell could selectively absorb the narrow spectral bandwidth laser radiation while transmitting the wide spectral bandwidth ASE. Transmission of laser amplifier pulses through a Rb absorption cell, measured at various temperatures, thus allows the measurement of the weak ASE in the vicinity of the strong laser pulse. A model for the transmission of Rb as a function of temperature and wavelength has been developed. The measured transmissions are in good agreement with the transmission model predictions.

Barnes, James C.↗

Dark matter axion search using a Josephson Traveling wave parametric amplifier

Here, we describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10 -13 Ge V -1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

47 OTHER INSTRUMENTATION↗

Overlap junctions for superconducting quantum electronics and amplifiers

Due to their unique properties as lossless, nonlinear circuit elements, Josephson junctions lie at the heart of superconducting quantum information processing. Previously, we demonstrated a two-layer, submicrometer-scale overlap junction fabrication process suitable for qubits with long coherence times. Here, we extend the overlap junction fabrication process to micrometer-scale junctions. This allows us to fabricate other superconducting quantum devices. For example, we demonstrate an overlap junction-based Josephson parametric amplifier that uses only two layers. This efficient fabrication process yields frequency-tunable devices with negligible insertion loss, a gain of ∼30 dB, and quantum limited noise performance. Compared to other processes, the overlap junction allows for fabrication with minimal infrastructure, high yield, and state-of-the-art device performance.

Bal, Mustafa (ORCID:0000000307516774)↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

Design of a high-gain laser diode-array pumped Nd:YAG Alternating Precessive Slab Amplifier (APS-Amplifier)

In the design of space qualifiable laser systems for ranging and altimetry, such as NASA's Geodynamic Laser Ranging System (GLRS), the transmitter must be kept small, powerful yet efficient, and must consist of as few components as possible. A novel preamplifier design is examined which requires no external beam steering optics, yielding a compact component with simple alignment procedures. The gains achieved are comparable to multipass zigzag amplifiers using two or more sets of external optics for extra passes through the amplifying medium.

Coyle, D. Barry↗

Design of a high-gain laser diode-array pumped Nd:YAG alternating precessive slab amplifier (APS amplifier)

In the design of space-qualifiable laser systems for ranging and altimetry, such as NASA's Geodynamic Laser Ranging System (GLRS), the transmitter must be kept small, powerful yet efficient, and must consist of as few components as possible. A novel preamplifier design is examined which requires no external beam steering optics, yielding a compact component with simple alignment procedures. The gains achieved are comparable to multipass zigzag amplifiers using two or more sets of external optics for extra passes through the amplifying medium.

Coyle, D. B.↗

On the Origin of Room-Temperature Amplified Spontaneous Emission in CsPbBr 3 Single Crystals

CsPbBr 3 is an all-inorganic halide perovskite with excellent photoluminescence (PL) properties for laser applications. Amplified spontaneous emission (ASE) is a prerequisite for lasing and typically observed from low-dimensional CsPbBr3 nanostructures, where quantum confinement enhances ASE. However, a gain medium for lasing should be prepared into a robust bulk form that works under intense light illumination. Here, we demonstrate that bulk CsPbBr 3 single crystals exhibit highly efficient ASE with a threshold of 46 MWcm -2 at 520 nm, if PL reabsorption via the indirect Rashba gap is properly suppressed by thickness control. Based on a series of spectroscopic and microscopic measurements, we show that this below-the-gap absorption can significantly alter the PL feature and even the apparent color of the crystal depending on the crystal size. Our results show that a thin CsPbBr 3 single crystal can be utilized for lasing applications when engineered into a submillimeter thickness for effective light–matter interaction.

36 MATERIALS SCIENCE↗

Chirality Amplified: Long, Discrete Helicene Nanoribbons

Here we report the synthesis of two polyhelicene frameworks consisting, from end-to-end, of 18 and 24 fused benzene rings. The latter exhibits the largest electronic circular dichroism in the visible spectrum of any molecule. These shape-persistent helical nanoribbons incorporate multiple helicenes, a class of contorted polycyclic aromatic molecules consisting of ortho-annulated rings. These conjugated, chiral molecules have interesting chemical, biological, and chiroptical properties; however, there are very few helicenes with extraordinary chiroptical response over a broad range of the visible spectrum—a key criterion for applications such as chiral optoelectronics. In this report, we show that coupling the polyhelicene framework with multiple perylene-diimide subunits elicits a significant chiroptic response. Notably, the molar circular dichroism increases faster than the absorptivity of these molecules as their helical axis lengthens. Computational analysis reveals that the greatly amplified circular dichroism arises from exciton-like interactions between the perylene-diimide and the helicene moieties. As a result, we predict that even greater chiroptic enhancement will result from further axial elongation of these nanoribbons, which can be readily enabled via the iterative synthetic method presented herein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of the pump beam profile and wavefront on the amplified signal wavefront in optical parametric amplifiers

We present a theoretical and experimental analysis of the signal phase introduced by the pump-beam wavefront and spatial profile during optical parametric amplification (OPA) process. The theory predicts the appearance of an additional wavefront in the amplified signal beam that is proportional to the spatial derivative of the pump-beam wavefront. The effect of the pump-beam profile on the signal-beam wavefront is also investigated. Our experiments tested these theoretical predictions by comparing the wavefront of the signal beam before and after amplification in a multi-joule broadband OPA. The measured signal wavefront was shown to have the expected dependence on the pump-beam profile and wavefront. These results can be considered when designing petawatt-scale ultrabroadband optical parametric chirped-pulse–amplification systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced electron amplifier structure and method of fabricating the enhanced electron amplifier structure

An enhanced electron amplifier structure includes a microporous substrate having a front surface and a rear surface, the microporous substrate including at least one channel extending substantially through the substrate between the front surface and the rear surface, an ion diffusion layer formed on a surface of the channel, the ion diffusion layer comprising a metal oxide, a resistive coating layer formed on the first ion diffusion layer, an emissive coating layer formed on the resistive coating layer, and an optional ion feedback layer formed on the front surface of the structure. The emissive coating produces a secondary electron emission responsive to an interaction with a particle received by the channel. The ion diffusion layer, the resistive coating layer, the emissive coating layer, and the ion feedback layer are independently deposited via chemical vapor deposition or atomic layer deposition.

Mane, Anil U.↗

Diffractive Imaging of Conical Intersections Amplified by Resonant Infrared Fields

The fate of virtually all photochemical reactions is determined by conical intersections. These are energetically degenerate regions of molecular potential energy surfaces that strongly couple electronic states, thereby enabling fast relaxation channels. Their direct spectroscopic detection relies on weak features that are often buried beneath stronger, less interesting contributions. For azobenzene photoisomerization, a textbook photochemical reaction, we demonstrate how a resonant infrared field can be employed during the conical intersection passage to significantly enhance its coherence signatures in time-resolved Xray diffraction while leaving the product yield intact. Furthermore, this transition-state amplification holds promise to bring signals of conical intersections above the detection threshold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗