Measurement uncertainty analysis for the calibration of analytical balances and scales.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Agglomeration of wet particles, i.e., particles coated with a thin liquid layer, is a common phenomenon in many processes like fluidized bed combustion of low rank fuels. The availability of an agglomeration model that can evaluate the outcome of a binary collision between wet particles differing in solid particle properties, liquid layer thicknesses, and initial collision (impact) speeds is essential for obtaining a comprehensive understanding on the existing processes experiencing wet particle agglomeration or for a successful development of new processes with high chances of wet particle agglomeration. This study presents a generalized agglomeration model on the basis of energy conservation before and after collision when colliding wet particles may differ in solid particle properties, liquid layer thicknesses, and impact speeds. The model was established based on the approximate values of energy losses that may happen during the collision. It incorporates body forces, solid-solid contacting, liquid capillary, and viscous contributions, as well as the liquid bridge volume effect. Predictions of the new model for collision outcomes of identical wet particles were like those from an analytical energy balance model developed recently by the group for identical wet particles. We also validated the new model by experimental data from literature. The results of a collision direction analysis indicated that the direction often has a minimal effect on the collision outcome in many practical scenarios. The results of Monte Carlo uncertainty analyses with the new model revealed that proper estimations of impact speed, under capillary limiting conditions, and thickness of coating layers and asperity heights, under viscous limiting conditions, are critical for the realistic prediction of collision outcomes at impact speeds close to critical impact speed, i.e., the minimum particle speed required for the particles to rebound.
We present a semi-analytic model for low (L) to high (H) mode transition power threshold (P{sub th}). Two main assumptions are made in our study. First, high poloidal mode number drift resistive ballooning modes (high-m DRBM) are assumed to be the dominant turbulence driver in a narrow edge region near to last closed flux surface. Second, the pre-transition edge profile and turbulent diffusivity at the narrow edge region pertain to turbulent equipartition. An edge power balance relation is derived by calculating the dissipated power flux through both turbulent conduction and convection, and radiation in the edge region. P{sub th} is obtained by imposing the turbulence quench rule due to sheared E × B rotation. Evaluation of P{sub th} shows a good agreement with experimental results in existing machines. Increase of P{sub th} at low density (i.e., the existence of roll-over density in P{sub th} vs. density) is shown to originate from the longer scale length of the density profile than that of the temperature profile.
Highlights: • Knowledge of wastes in substances will be necessary to assess HP1–HP15 hazard properties. • A new analytical protocol is proposed for this and tested by two service laboratories on 32 samples. • Sixty-three percentage of the samples have a satisfactory analytical balance between 90% and 110%. • Eighty-four percentage of the samples were classified identically (Seveso Directive) for their hazardousness by the two laboratories. • The method, in progress, is being normalized in France and is be proposed to CEN. - Abstract: The classification of waste as hazardous could soon be assessed in Europe using largely the hazard properties of its constituents, according to the the Classification, Labelling and Packaging (CLP) regulation. Comprehensive knowledge of the component constituents of a given waste will therefore be necessary. An analytical protocol for determining waste composition is proposed, which includes using inductively coupled plasma (ICP) screening methods to identify major elements and gas chromatography/mass spectrometry (GC–MS) screening techniques to measure organic compounds. The method includes a gross or indicator measure of ‘pools’ of higher molecular weight organic substances that are taken to be less bioactive and less hazardous, and of unresolved ‘mass’ during the chromatography of volatile and semi-volatile compounds. The concentration of some elements and specific compounds that are linked to specific hazard properties and are subject to specific regulation (examples include: heavy metals, chromium(VI), cyanides, organo-halogens, and PCBs) are determined by classical quantitative analysis. To check the consistency of the analysis, the sum of the concentrations (including unresolved ‘pools’) should give a mass balance between 90% and 110%. Thirty-two laboratory samples comprising different industrial wastes (liquids and solids) were tested by two routine service laboratories, to give circa 7000 parameter results. Despite discrepancies in some parameters, a satisfactory sum of estimated or measured concentrations (analytical balance) of 90% was reached for 20 samples (63% of the overall total) during this first test exercise, with identified reasons for most of the unsatisfactory results. Regular use of this protocol (which is now included in the French legislation) has enabled service laboratories to reach a 90% mass balance for nearly all the solid samples tested, and most of liquid samples (difficulties were caused in some samples from polymers in solution and vegetable oil). The protocol is submitted to French and European normalization bodies (AFNOR and CEN) and further improvements are awaited.
In remote sensing, the Photochemical Reflectance Index (PRI) provides insight into physiological processes occurring inside the leaves in a stand of plants. Developed by Gamon et al., (1990 and 1992), PRI evolved from laboratory measurements of the reflectance of individual leaves (Bilger et al.,1989). Yet in a remotely sensed image, a pixel measurement may include light from both reflecting and transmitting leaves. We conducted laboratory experiments comparing values of PRI based upon polarized reflectance and transmittance measurements of water and nutrient stressed leaves. We illuminated single detached leaves using a current controlled light source (Oriel model 66881) and measured the leaf weight using an analytical balance (Mettler model AE 260) and the light reflected and transmitted by the leaf during dry down using two Analytical Spectral Devices spectroradiometers. Polarizers on the incident and reflected light beams allowed us to divide the leaf reflectance into two parts: a polarized surface reflectance and a non-polarized 'leaf interior' reflectance. Our results underscore the importance when calculating PRI of removing the leaf surface reflection, which contains no information about physiological processes ongoing in the leaf interior. The results show that the leaf physiology information is in the leaf interior reflectance, not the leaf transmittance. Applied to a plant stand, these results suggest use of polarization measurements in sun-view directions that minimize the number of sunlit transmitting leaves in the sensor field of view.
In this study, five different metal coupons were evaluated for gaseous iodine [I2(g)] adsorption including two stainless steels (i.e., SS304 and SS316), two Inconel® alloys (i.e., 625 and 718) and pure Ni (i.e., Ni-200) within a dynamic flow-through system where temperature, iodine concentration, flow rate, atmosphere, and relative humidity were controlled. Humidity was shown to be critical to iodine adsorption on SS304 and SS316 and Ni-200 at ambient temperatures. The results presented herein suggest that a moisture mediated reaction is occurring. However, higher humidity levels decrease the adsorption, suggesting an ideal range of humidity for highest corrosion. A comparison of the five metal substrates showed the highest I2(g) adsorption in the following descending order Ni-200 > SS304 > SS316 >718>625.The 625 and 718 Inconel alloys were fairly inert to iodine adsorption under the conditions tested. Characterization by scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction of the Ni-200 coupon indicates that NiI2 is formed and flakes off the surface as a black powder. The SS304 and SS316 coupons showed evidence of extensive reactions with I2(g) and formed a much more deliquescent corrosion product, which reacted with air when removed from the flow-through system for weighing on the analytical balance. These findings assist in predicting iodine adsorption behavior on a variety of metal surfaces under various conditions.
A short report on the activities developed in the Target Laboratory, since 1970, will be presented. Basic target laboratory facilities were provided to produce the necessary nuclear targets as well as the ion beam stripper foils. Vacuum evaporation units, a roller, a press and an analytical balance were installed in the Oscar Sala building. A brief historical report will be presented in commemoration of the 40{sup th} year of the Pelletron Accelerator.
Here, the lithium vapor box divertor is a concept for handling the extreme divertor heat fluxes in magnetic fusion devices. In a baffled slot divertor, plasma interacts with a dense cloud of Li vapor which radiates and cools the plasma, leading to recombination and detachment. Before testing on a tokamak, the concept should be validated: we plan to study detachment and heat redistribution by a Li vapor cloud in laboratory experiments. Mass changes and temperatures are measured to validate a direct simulation Monte Carlo model of neutral Li. The initial experiment involves a 5 cm diameter steel box containing 10 g of Li held at 650 °C as vapor flows out a wide nozzle into a similarly sized box at a lower temperature. Diagnosis is made challenging by the required material compatibility with lithium vapor. Vapor pressure is a steep function of temperature, so to validate mass flow models to within 10%, absolute temperature to within 4.5 K is required. The apparatus is designed to be used with an analytical balance to determine mass transport. Details of the apparatus and methods of temperature and mass flow measurements are presented.
Although atmospheric pressure dielectric barrier discharges (DBDs) have a long history, the effects of water vapor on the discharge morphology and kinetics have not been studied intensively. We report a simultaneous investigation of discharge morphology, OH and H 2 O 2 production in Ar and He DBDs operated at different water vapor concentrations and powers. The combined study allows us to assess the impact of the discharge morphology and power on the concentration dependence of the OH and H 2 O 2 production. The morphology of the discharge is investigated by ICCD images and current–voltage waveforms. These diagnostics are complemented by broadband absorption and a colorimetric method to measure the gas temperature and the OH and H 2 O 2 concentrations. The number of filaments in Ar DBD increases with increasing water concentration and power. The surface discharge part of the micro-discharge also reduces with increasing water concentration most likely due to a change in surface conductivity of the dielectric with changing water concentration. The OH density in the case of Ar is approximately double the OH density in He for similar power and water admixture. In contrast to the root square dependence of the OH density on the water concentration in He similar to diffuse RF discharges, the OH density in Ar increases for small water concentrations followed by a saturation and reduces for higher water concentrations. Furthermore, this dependence of OH density on water concentration is found to correlate with changes in discharge morphology. An analytical balance of the production and destruction mechanism of H 2 O 2 is shown to be able to reproduce the ratio of the measured OH and H 2 O 2 density for realistic values of electron densities.
The lithium vapor box divertor is a concept for handling the extreme divertor heat fluxes in magnetic fusion devices. In a baffled slot divertor, plasma interacts with a dense cloud of Li vapor which radiates and cools the plasma, leading to recombination and detachment. Before testing on a tokamak the concept should be validated: we plan to study detachment and heat redistribution by a Li vapor cloud in laboratory experiments.Mass changes and temperatures are measured to validate a Direct Simulation Monte Carlo model of neutral Li.The initial experiment involves a 5 cm diameter steel box containing 10g of Li held at 650 degrees C as vapor flows out a wide nozzle into a similarly-sized box at a lower temperature. Diagnosis is made challenging by the required material compatibility with lithium vapor. Vapor pressure is a steep function of temperature, so to validate mass flow models to within 10%, absolute temperature to within 4.5K is required. The apparatus is designed to be used with an analytical balance to determine mass transport. Details of the apparatus and methods of temperature and mass flow measurements are presented.
Accurate and precise density measurements by hydrostatic weighing requires the use of an analytical balance, configured with a suspension system, to both measure the weight of a part in water and in air. Additionally, the densities of these liquid media (water and air) must be precisely known for the part density determination. To validate the accuracy and precision of these measurements, uncertainty statements are required. The work in this report is a revision of an original report written more than a decade ago, specifically applying principles and guidelines suggested by the Guide to the Expression of Uncertainty in Measurement (GUM) for determining the part density uncertainty through sensitivity analysis. In this work, updated derivations are provided; an original example is revised with the updated derivations and appendix, provided solely to uncertainty evaluations using Monte Carlo techniques, specifically using the NIST Uncertainty Machine, as a viable alternative method.
In this study, the volumetric compression of jadeite (NaAlSi 2 O 6 ) melt at high pressures was determined by three-dimensional volume imaging using the synchrotron-based X-ray microtomography technique in a rotation-anvil device. Combined with the sample mass, measured using a high-precision analytical balance prior to the high-pressure experiment, the density of jadeite melt was obtained at high pressures and high temperatures up to 4.8 GPa and 1955 K. The density data were fitted to a third-order Birch-Murnaghan equation of state, resulting in a best-fit isothermal bulk modulus K T0 of $10.8$ $^{+1.9}_{–5.3}$ GPa and its pressure derivative K' T0 of $3.4$ $^{+6.6}_{–0.4}$. Comparison with data for silicate melts of various compositions from the literature shows that alkali-rich, polymerized melts are generally more compressible than alkali-poor, depolymerized ones. The high compressibility of jadeite melt at high pressures implies that polymerized sodium aluminosilicate melts, if generated by low-degree partial melting of mantle peridotite at ~250–400 km depth in the deep upper mantle, are likely denser than surrounding mantle materials, and thus gravitationally stable.
System measures unidirectional force without interference from other directional forces. The measuring apparatus is mounted so that it only moves vertically and is constrained from horizontal and rotational movement. This system can be used to accurately measure small forces in one direction, or as an analytic balance.
A detailed description and explanation of the operational availability parameter is presented. The fundamental mathematical basis for operational availability is developed, and its relationship to a system's overall performance effectiveness is illustrated within the context of identifying specific availability requirements. Thus, in attempting to provide a general methodology for treating both hypothetical and existing availability requirements, the concept of an availability state, in conjunction with the more conventional probability-time capability, is investigated. In this respect, emphasis is focused upon a balanced analytical and pragmatic treatment of operational availability within the system design process. For example, several applications of operational availability to typical aerospace systems are presented, encompassing the techniques of Monte Carlo simulation, system performance availability trade-off studies, analytical modeling of specific scenarios, as well as the determination of launch-on-time probabilities. Finally, an extensive bibliography is provided to indicate further levels of depth and detail of the operational availability parameter.
System developed at Johnson Space Center controls and measures oxygen fugacity in high-temperature chemical research. A ceramic-electrolyte cell is the sensing element. All hardware needed to control gas flow and temperature and to measure cell electromotive force is included. An analytic balance allows in situ thermogravimetric sample analysis.
Radiative recombination coefficients for all Fe ions are calculated by use of the Milne relation of detailed balance. Analytic fits are made to the dielectronic recombination rates computed by Jacobs (1977) and the Burgess general formula (1965). Higher level rates are treated hydrogenically by a quantum defect method based on the energies of the levels. Recombination coefficients for Fe I to Fe 26 are listed.
The objective is to understand how surfaces outgas and how outgassed substances subsequently condense on other surfaces. Preliminary tests produced calculated mass losses that were found to be in reasonable agreement with mass losses determined by weighing the sample before and after testing on analytical balances. However, using test materials with various molecular properties showed characteristic variations in the ratios of calculated total mass loss to experimental loss. These variations indicate that for some molecules energetic barriers to absorption and desorption can exist between outgassed molecules and the surfaces on which they condense.