Search NASA⌕ Search

SEARCH · Search NASA

Results for “Anechoic chambers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A two dimensional finite difference time domain analysis of the quiet zone fields of an anechoic chamber

Prediction of anechoic chamber performance is a difficult problem. Electromagnetic anechoic chambers exist for a wide range of frequencies but are typically very large when measured in wavelengths. Three dimensional finite difference time domain (FDTD) modeling of anechoic chambers is possible with current computers but at frequencies lower than most chamber design frequencies. However, two dimensional FDTD (2D-FTD) modeling enables much greater detail at higher frequencies and offers significant insight into compact anechoic chamber design and performance. A major subsystem of an anechoic chamber for which computational electromagnetic analyses exist is the reflector. First, an analysis of the quiet zone fields of a low frequency anechoic chamber produced by a uniform source and a reflector in two dimensions using the FDTD method is presented. The 2D-FDTD results are compared with results from a three dimensional corrected physical optics calculation and show good agreement. Next, a directional source is substituted for the uniform radiator. Finally, a two dimensional anechoic chamber geometry, including absorbing materials, is considered, and the 2D-FDTD results for these geometries appear reasonable.

Ryan, Deirdre A.↗

Anechoic chamber in industrial plants

A light anechoic chamber for routine acoustical measurements in the machine building industry is reported. The outer housing of the chamber consists of modules cast in glass fiber reinforced polyester resin; the inner housing consists of pyramidal modules cut out of sound absorbing slates. The parameters of this anechoic chamber facilitate acoustical measurements according to ISO and CAEM recommendations.

Halpert, E.↗

Anechoic Chambers: Aerospace Applications. (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning the design, development, performance, and applications of anechoic chambers in the aerospace industry. Anechoic chamber testing equipment, techniques for evaluation of aerodynamic noise, microwave and radio antennas, and other acoustic measurement devices are considered. Shock wave studies on aircraft models and components, electromagnetic measurements, jet flow studies, and antenna radiation pattern measurements for industrial and military aerospace equipment are discussed. (Contains 50-250 citations and includes a subject term index and title list.)

ANECHOIC CHAMBERS↗

Anechoic Chambers: Aerospace Applications. (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning the design, development, performance, and applications of anechoic chambers in the aerospace industry. Anechoic chamber testing equipment, techniques for evaluation of aerodynamic noise, microwave and radio antennas, and other acoustic measurement devices are considered. Shock wave studies on aircraft models and components, electromagnetic measurements, jet flow studies, and antenna radiation pattern measurements for industrial and military aerospace equipment are discussed. (Contains 50-250 citations and includes a subject term index and title list.)

AERODYNAMIC NOISE↗

Acoustic and Performance Measurements Obtained in the NASA Langley Small Hover Anechoic Chamber

The emergence of small Unmanned Aircraft Systems (UAS) and Advanced Air Mobility (AAM) vehicles has motivated the need to acoustically characterize the rotors found on these vehicle platforms. Hover chamber tests of small rotors are beneficial in assessing the noise impact of UAS, and potentially larger AAM vehicles. Various experiments have been conducted in the NASA Langley Small Hover Anechoic Chamber (SHAC), formerly known as the Small Anechoic Jet Facility (SAJF), in order to investigate the noise and performance of small rotors. One of these tests was that of an “ideally twisted rotor”, which was designed in order to simplify the theoretical rotor inflow for a target thrust condition in hover. This rotor was fabricated using state-of-the-art rapid prototyping and tested in the SHAC. Aerodynamic load and acoustic data were acquired across a range of rotation rates and rotor collective settings. Both tonal and broadband components were identified in the acoustic data, with broadband noise being a prominent contributor to the overall rotor system noise.

Nicole Pettingill↗

Effectiveness of an inlet flow turbulence control device to simulate flight noise fan in an anechoic chamber

A hemispherical inlet flow control device was tested on a 50.8 cm. (20-inch) diameter fan stage in the NASA-Lewis anechoic chamber. The control device used honeycomb and wire mesh to reduce turbulence intensities entering the fan. Far field acoustic power level results show about a 5 db reduction in blade passing tone and about 10 dB reduction in multiple pure tone sound power at 90% design fan speed with the inlet device in place. Hot film cross probes were inserted in the inlet to obtain data for two components of the turbulence at 65 and 90% design fan speed. Without the flow control device, the axial intensities were below 1.0%, while the circumferential intensities were almost twice this value. The inflow control device significantly reduced the circumferential turbulence intensities and also reduced the axial length scale.

Woodward, R. P.↗

Effectiveness of an inlet flow turbulence control device to simulate flight fan noise in an anechoic chamber

A hemispherical inlet flow control device was tested on a 50.8 cm. (20-inch) diameter fan stage in the NASA-Lewis Anechoic Chamber. The control device used honeycomb and wire mesh to reduce turbulence intensities entering the fan. Far field acoustic power level results showed about a 5 dB reduction in blade passing tone and about 10 dB reduction in multiple pure tone sound power at 90% design fan speed with the inlet device in place. Hot film cross probes were inserted in the inlet to obtain data for two components of the turbulence at 65 and 90% design fan speed. Without the flow control device the axial intensities were below 1.0%, while the circumferential intensities were almost twice this value. The inflow control device significantly reduced the circumferential turbulence intensities and also reduced the axial length scale.

Woodward, R. P.↗

Analysis of Anechoic Chamber Testing of the Hurricane Imaging Radiometer

The Hurricane Imaging Radiometer System (HIRAD) is a new airborne passive microwave remote sensor developed to observe hurricanes. HIRAD incorporates synthetic thinned array radiometry technology, which use Fourier synthesis to reconstruct images from an array of correlated antenna elements. The HIRAD system response to a point emitter has been measured in an anechoic chamber. With this data, a Fourier inversion image reconstruction algorithm has been developed. Performance analysis of the apparatus is presented, along with an overview of the image reconstruction algorithm

Fenigstein, David↗

Reduction of fan noise in an anechoic chamber by reducing chamber wall induced inlet flow disturbances

The difference between the flight and ground static noise of turbofan engines presents a significant problem in engine noise testing. The additional noise for static testing has been attributed to inlet flow disturbances or turbulence interacting with the fan rotor. In an attempt to determine a possible source of inflow disturbances entering fans tested in the Lewis Research Center anechoic chamber, the inflow field was studied using potential flow analysis. These potential flow calculations indicated that there was substantial flow over the wall directly behind the fan inlet that could produce significant inflow disturbances. Fan noise tests were run with various extensions added to the fan inlet to move the inlet away from this backwall and thereby reduce the inlet flow disturbances. Significant noise reductions were observed with increased inlet length. Over 5 db reduction of the blade passage tone sound power level was observed between the shortest and longest inlets at 90% fan speed and the first overtone was reduced 9 db. High frequency broadband noise was also reduced.

Dittmar, J. H.↗

Reduction of fan noise in an anechoic chamber by reducing chamber wall induced inlet flow disturbances

The difference between the flight and ground static noise of turbofan engines has been identified as a significant problem in engine noise testing. The additional noise for static testing has been attributed to inlet flow disturbances or turbulence interacting with the fan rotor. In an attempt to determine a possible source of inflow disturbances entering fans tested in the Lewis Research Center anechoic chamber the inflow field was studied using potential flow analysis. These potential flow calculations indicated that there was substantial flow over the wall directly behind the fan inlet that could produce significant inflow disturbances. Fan noise tests were run with various extensions added to the fan inlet to move the inlet away from this backwall and thereby reduce the inlet flow disturbances. Significant noise reductions were observed with increased inlet length. Over 5 dB reduction of the blade passage tone sound power level was observed between the shortest and longest inlets at 90% fan speed and the first overtone was reduced 9 dB. High frequency broadband noise was also reduced.

Dittmar, J. H.↗

Characteristics of an anechoic chamber for fan noise testing

Acoustical and mechanical design features of NASA Lewis Research Center's engine fan noise facility are described. Acoustic evaluation of the 1420-m (50,000-ft) chamber, which is lined with an array of stepped wedges, is described. Results from the evaluation in terms of cut-off frequency and non-anechoic areas near the walls are detailed. Fan models with 0.51-m (20-in) diameters are electrically driven to 20,600 rpm in either the inlet mode (drawing air from the chamber) or exhaust mode (discharging air into the chamber) to facilitate study of both fore and aft fan noise. Inlet noise characteristics of the first fan tested, the JT8D Refan, are discussed and compared to full-scale levels. Turbulence properties of the inlet flow and acoustic results are compared with and without a turbulence reducing screen over the fan inlet.

Wazyniak, J. A.↗

Characteristics of an anechoic chamber for fan noise testing

Acoustical and mechanical design features of NASA Lewis Research Center's engine fan noise facility are described. Acoustic evaluation of the chamber, which is lined with an array of stepped wedges, is described. Results from the evaluation in terms of cut-off frequency and non-anechoic areas near the walls are detailed. Fan models are electrically driven to 20,600 RPM in either the inlet mode or exhaust mode to facilitate study of both fore and aft fan noise. Inlet noise characteristics of the first fan tested are discussed and compared to full-scale levels. Turbulence properties of the inlet flow and acoustic results are compared with and without a turbulence reducing screen over the fan inlet.

Wuzyniak, J. A.↗

Inlet noise on 0.5-meter-diameter NASA QF-1 fan as measured in an unmodified compressor aerodynamic test facility and in an anechoic chamber

Narrowband analysis revealed grossly similar sound pressure level spectra in each facility. Blade passing frequency (BPF) noise and multiple pure tone (MPT) noise were superimposed on a broadband (BB) base noise. From one-third octave bandwidth sound power analyses the BPF noise (harmonics combined), and the MPT noise (harmonics combined, excepting BPF's) agreed between facilities within 1.5 db or less over the range of speeds and flows tested. Detailed noise and aerodynamic performance is also presented.

Gelder, T. F.↗

Model-scale sound propagation experiment

The results of a scale model propagation experiment to investigate grazing propagation above a finite impedance boundary are reported. In the experiment, a 20 x 25 ft ground plane was installed in an anechoic chamber. Propagation tests were performed over the plywood surface of the ground plane and with the ground plane covered with felt, styrofoam, and fiberboard. Tests were performed with discrete tones in the frequency range of 10 to 15 kHz. The acoustic source and microphones varied in height above the test surface from flush to 6 in. Microphones were located in a linear array up to 18 ft from the source. A preliminary experiment using the same ground plane, but only testing the plywood and felt surfaces was performed. The results of this first experiment were encouraging, but data variability and repeatability were poor, particularly, for the felt surface, making comparisons with theoretical predictions difficult. In the main experiment the sound source, microphones, microphone positioning, data acquisition, quality of the anechoic chamber, and environmental control of the anechoic chamber were improved. High-quality, repeatable acoustic data were measured in the main experiment for all four test surfaces. Comparisons with predictions are good, but limited by uncertainties of the impedance values of the test surfaces.

Willshire, William L., Jr.↗

Anti-Phase Vortex Reduction Control for Rotor Noise Suppression

An investigation is conducted in 2019 under the NASA Ames Center Innovation Funds (CIF) project entitled “Anti-Phase Vortex Reduction Control for Rotor Noise Suppression“ to experimentally validate an anti-phase rotor noise suppression concept. The first objective of the investigation is to conduct computational fluid dynamics (CFD) simulations to investigate the noise characteristics of several anti-phase rotor designs. The second objective is to conduct a series of acoustic tests of anti-phase rotors in an anechoic chamber at Pennsylvania State University (PSU) to evaluate the merit of the anti-phase rotor concept. The CFD investigation seeks to optimize the anti-phase alternating trailing edge patterns for rotor noise suppression. The design objective is to maximize the noise reduction while maintaining the aerodynamic thrust. The investigation is performed using a three-dimensional (3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) commercial solver STAR-CCM+ together with the Ffowcs-Williams and Hawkings (FW-H) formula to obtain the aerodynamic thrust and far-field noise level. An acoustic study is conducted for 13 anti-phase design candidates based on a proprietary rotor design. The CAD geometry of the rotor is furnished by PSU. These design candidates include different alternating trailing edge (TE) waveforms, TE segment lengths, TE deflection amplitudes, and transition characteristics. The best design candidate among those explored is an anti-phase rotor that has a four-period TE waveform which results in a reduction in far-field noise level of 2.1 dB in the hover condition and a reduction of 1.1 dB in the forward flight condition at 9.7 m/s. A further acoustic study is conducted for a different rotor manufactured by APC. Five APC rotor design candidates are simulated. The best anti-phase design candidate for the APC rotor results in a reduction in far-field noise level of 4.0 dB in the hover condition. An in-phase design candidate is also studied. This in-phase design provides a noise reduction of 2.5 dB. A series of acoustic experiments in the PSU anechoic chamber have been conducted in July 2019 and October 2019. Both anti-phase and in-phase rotors fabricated for the left-hand and right-hand rotations are tested. In the hover condition, all the rotors do not provide sufficient evidence of improved acoustic performance. However, the experimental data in the hover condition are deemed to be inconclusive due to the flow recirculation in the anechoic chamber caused by the rotor downwash. In the forward flight condition at 9.7 m/s, the anti-phase right-hand rotor produces a noise reduction by as much as 6.5 dB in the frequency range of 2000-4000 Hz, while the in-phase right-hand rotor produces a noise reduction by as much as 5 dB in the same frequency range. Both the anti-phase and in-phase left hand rotors offer no evidence of noise reduction. The difference in the acoustic performance of the left-hand and right-hand rotors could be explained by the location of the microphone array which is placed to the left side of the rotors. This microphone array location could create a bias in the sound pressure level in favor of the right-hand rotor. Using the average noise reduction values, the anti-phase 4H rotor could offer a noise reduction by as much as 3.25 dB while the in-phase 4I rotor could produce up to a 2.5 dB noise reduction. Both the computational and experimental results have provided sufficient evidence to support the noise suppression capability of the proposed anti-phase rotor concepts.

Rotor noise↗

Aerodynamic-whistles-based ultrasonic tone generators for bat deterrence

Novel ultrasonic bat deterrents based on aerodynamic whistles are proposed and investigated experimentally and numerically for their ability to generate ultrasound. The baseline deterrent, a single-whistle design inspired by Beeken [“Fluid ultrasonic generator,” U.S. patent 3,432,804 (1969)], is examined first. It consists of two resonating cavities/chambers. The whistle is “powered” by a regulated high-pressure air supply, and the performance of the whistle is examined for a range of supply pressures. Far-field acoustic measurements in the 20 Hz–50 kHz frequency range are made in an anechoic chamber. The noise measurements are supplemented with two- and three-dimensional unsteady Reynolds-averaged Navier–Stokes (uRANS) simulations to investigate the mechanisms of ultrasound generation. The Ffowcs Williams–Hawkings acoustic analogy is used with the three-dimensional uRANS results to predict the far-field radiation. The far-field acoustic predictions are in good agreement with the measurements in the anechoic chamber. The peak frequency (fundamental) of the radiated ultrasound of the baseline deterrent is approximately 23 kHz. Harmonics and a sub-harmonic of the fundamental tone are also observed. The numerical simulations show that the two resonating chambers of the baseline deterrent operate out-of-phase and Helmholtz resonance determines the whistling frequency over the range of supply air pressure considered. A six-whistle deterrent targeting a broad spectral coverage in the 20–50 kHz frequency range is designed, fabricated, and tested in the anechoic chamber. Each whistle in the deterrent is obtained by geometrically scaling the baseline whistle. Measurements show that the six-whistle ultrasound deterrent generates ultrasound with six dominant peaks in the designed frequency range when the supply air pressure exceeds 5 psig. The proposed ultrasound devices can be used for a variety of purposes including bat deterrence at wind turbines.

42 ENGINEERING↗

Determining Transmission Loss from Measured External and Internal Acoustic Environments

An estimate of the internal acoustic environment in each internal cavity of a launch vehicle is needed to ensure survivability of Space Launch System (SLS) avionics. Currently, this is achieved by using the noise reduction database of heritage flight vehicles such as the Space Shuttle and Saturn V for liftoff and ascent flight conditions. Marshall Space Flight Center (MSFC) is conducting a series of transmission loss tests to verify and augment this method. For this test setup, an aluminum orthogrid curved panel representing 1/8th of the circumference of a section of the SLS main structure was mounted in between a reverberation chamber and an anechoic chamber. Transmission loss was measured across the panel using microphones. Data measured during this test will be used to estimate the internal acoustic environments for several of the SLS launch vehicle internal spaces.

Scogin, Tyler↗

The New Anechoic Shielded Chambers Designed for Space and Commercial Applications at LIT

The main objective of this paper is to present the capabilities of the new anechoic shielded rooms designed for space and commercial applications as part of the Integration and Testing Laboratory (LIT, Laboratorio de Integracao e Testes) in Brazil. A new anechoic shielded room named CBA2 has been in full operation since March 2007 and a remodeled chamber CBA1 is planned to be ready by the end of 2008, replacing an old facility which was in operation for the last 18 years. The Brazilian Space Program started with very small and simple satellites and the old CBA1 chamber was conceived in 1987 to accomplish the EMI/EMC tests not requiring significant volumes. Since the very beginning this facility was also used by the private sector for other applications mainly due to the absorption of digital electronics in all kind of products. The intense use of this facility during the last years, operating three shifts a day, caused a normal degradation and imposed several limitations. Therefore, a new totally remodeled chamber was designed considering the state of the art in terms of absorbers and associated instrumentation. On the other hand the facility CBA2 was conceived, designed and implemented to test large satellites taking into account the advance of the technology in terms of RF frequencies, power level, testing methodologies and several other factors. A very interesting and unique aspect of this project was the partnership between the private sector and governmental institution. As a result, the total investment was shared between several companies and consequently a time-sharing use of the facility as well.

da Silva, Benjamim↗