Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angle Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Machine-learning-based automatic small-angle measurement between planar surfaces in interferometer images: A 2D multilayer Laue lenses case

Here, we report a new machine-learning-based approach to automatically measure the small angle between multiple planar surfaces characterized by white light interferometers. By applying an unsupervised clustering algorithm, DBSCAN (Density-Based Spatial Clustering of Applications with Noise), the multiple surfaces in an interferometer image are automatically identified as distinct surfaces. The angles between every two surfaces are then calculated through the surface fitting. This method can be applied to multiple surfaces regardless of their shapes and locations and significantly simplifies the angle measurement procedure. Using the developed method, we have demonstrated a quick and precise angle measurement for the alignment of 2D Multilayer Laue Lenses (MLLs) for the development of high-resolution x-ray microscopy. This automatic, accurate, and robust small-angle measurement method is compatible with widely used white light interferometers and can be further applied to other metrology applications of interferometer results.

36 MATERIALS SCIENCE↗

Definition of System Angle Reference for Distribution Level Synchronized Angle Measurement Applications

Distribution phasor measurement units (DPMUs) provide power grid operators unprecedented system monitoring opportunities with local-area, synchronized, low latency, and high-resolution measurements. All raw angle measurements in DPMUs need a common angle reference for comparison since the phase is likely to be shifted by transformers in distribution network. To obtain a robust reference under conditions of data loss or local oscillation, this letter proposes a definition of system angle reference for DPMU. The effectiveness of this system angle is confirmed via real measurement data collected by DPMUs.

42 ENGINEERING↗

A New Modeling Approach for a Priori Uncertainties of Laser Tracker Angle Measurements

Methods for modeling the uncertainty in laser tracker angle measurements vary within the metrology industry, leading to confusion and questionable stochastic modeling for survey network adjustments and error propagation analysis. Interpreting the published laser tracker manufacturer performance specifications to determine an a priori sigma value for weighting azimuth and zenith angle measurements can be confusing and has led to differing implementations. Furthermore, this paper proposes a unique way to model survey network a priori laser tracker angular uncertainties based on laser tracker manufacturers’ published maximum permissible error (MPE) values referenced to current standards for weighting survey network measurements. This paper’s proposed model takes into account the disparate effects that pointing errors, target centering errors, and leveling errors have on azimuth and zenith angular uncertainties for measurements with steep sightings and at near ranges.

42 ENGINEERING↗

Method of rotation angle measurement in machine vision based on calibration pattern with spot array

We propose a method of rotation angle measurement with high precision in machine vision. An area scan CCD camera, imaging lens, and calibration pattern with a spot array make up the measurement device for measuring the rotation angle. The calibration pattern with a spot array is installed at the rotation part, and the CCD camera is set at a certain distance from the rotation components. The coordinates of the spots on the calibration pattern is acquired through the vision image of the calibration pattern captured by the CCD camera. At the initial position of the calibration pattern, the camera is calibrated with the spot array; the mathematical model of distortion error of the CCD camera is built. With the equation of coordinate rotation measurement, the rotation angle of the spot array is detected. In the theoretic simulation, noise of different levels is added to the coordinates of the spot array. The experiment results show that the measurement device can measure the rotation angle precisely with a noncontact method. The standard deviation of rotation angle measurement is smaller than 3 arc sec. The measurement device can measure both microangles and large angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Transient analysis of advancing contact angle measurements on polished rock surfaces

We report that contact angle measurements for gas-liquid-rock systems are important for modeling multi-phase flow and transport in the subsurface. These data are needed in applications such as the extraction of oil and gas resources, geologic sequestration of carbon dioxide, contaminant fate and transport, and aquifer recharge through the vadose zone. Contact angles are frequently measured with the sessile drop method. Previous research has largely ignored the dynamic behavior of sessile droplets on geologic materials. This study investigates the dynamic behavior of sessile water droplets on prepared rock surfaces in the presence of air. Droplet diameter and advancing contact angle were determined at 0.5 s intervals for ~90 s on flat polished disks of Burlington limestone, Crossville sandstone, Mancos shale, Sierra White granite, Vermilion Bay granite, and Westerly granite using a Krüss DSA 30 Drop Shape Analyzer. The droplet diameter and advancing contact angle data sets were nonlinearly regressed against time using two different two-parameter models. The median coefficients of determination for the fits were 0.85 and 0.96, respectively. The resulting parameter estimates were used to compute the apparent equilibrium contact angle, θ e , for each disk following droplet diameter stabilization. Estimates of θ e ranged from 37.2° for Mancos shale to 75.6° for Burlington limestone. Analysis of variance indicated statistically significant differences in θ e between the rock types at the 95% confidence level. The variability of θe on the polished rock surfaces, as quantified by the coefficient of variation (CV) for θ e , varied between ~3 and ~9%; there were no significant differences in CV between the rock types. Neutron radiography indicated changes droplet morphology over time were due to the spontaneous imbibition of water into the rock matrix. Finally, the transient analysis employed in this study permits a more meaningful estimate of the equilibrium contact angle for rocks than taking the initial value or averaging over time as is frequently done.

58 GEOSCIENCES↗

Laser Tracker Calibration - Testing the Angle Measurement System -

Physics experiments at the SLAC National Accelerator Laboratory (SLAC) usually require high accuracy positioning, e. g. 100 {micro}m over a distance of 150 m or 25 {micro}m in a 10 x 10 x 3 meter volume. Laser tracker measurement systems have become one of the most important tools for achieving these accuracies when mapping components. The accuracy of these measurements is related to the manufacturing tolerances of various individual components, the resolutions of measurement systems, the overall precision of the assembly, and how well imperfections can be modeled. As with theodolites and total stations, one can remove the effects of most assembly and calibration errors by measuring targets in both direct and reverse positions and computing the mean to obtain the result. However, this approach does not compensate for errors originating from the encoder system. In order to improve and gain a better understanding of laser tracker angle measurement tolerances we extended our laboratory's capabilities with the addition of a horizontal angle calibration test stand. This setup is based on the use of a high precision rotary table providing an angular accuracy of better than 0.2 arcsec. Presently, our setup permits only tests of the horizontal angle measurement system. A test stand for vertical angle calibration is under construction. Distance measurements (LECOCQ & FUSS, 2000) are compared to an interferometer bench for distances of up to 32 m. Together both tests provide a better understanding of the instrument and how it should be operated. The observations also provide a reasonable estimate of covariance information of the measurements according to their actual performance for network adjustments.

43 PARTICLE ACCELERATORS↗

Measurement of B⁰→J/ψη (') and constraint on the η-η' mixing angle

We measure the branching fractions of B⁰→J/ψη (') decays with the complete Belle data sample of 772×10⁶ BB¯¯¯ events collected at the Υ(4S) resonance with the Belle detector at the KEKB asymmetric-energy e⁺e⁻ collider. The results for the branching fractions are: B(B⁰→J/ψη)=(12.3± 1.81 1.7 ±0.7)×10⁻⁶ and B(B⁰→J/ψη')<7.4×10⁻⁶ at 90% confidence level. The η-η' mixing angle is constrained to be less than 42.2° at 90% confidence level.

Chang, M.-C.↗

Are Contact Angle Measurements Useful for Oxide-Coated Liquid Metals?

This work establishes that static contact angles for gallium-based liquid metals have no utility despite the continued and common use of such angles in the literature. In the presence of oxygen, these metals rapidly form a thin (~1–3 nm) surface oxide “skin” that adheres to many surfaces and mechanically impedes its flow. This property is problematic for contact angle measurements, which presume the ability of liquids to flow freely to adopt shapes that minimize the interfacial energy. We show here that advancing angles for a metal are always high (>140°)—even on substrates to which it adheres—because the solid native oxide must rupture in tension to advance the contact line. The advancing angle for the metal depends subtly on the substrate surface chemistry but does not vary strongly with hydrophobicity of the substrate. During receding measurements, the metal droplet initially sags as the liquid withdraws from the “sac” formed by the skin and thus the contact area with the substrate initially increases despite its volumetric recession. Furthermore, the oxide pins at the perimeter of the deflated “sac” on all the surfaces are tested, except for certain rough surfaces. With additional withdrawal of the liquid metal, the pinned angle gets smaller until eventually the oxide “sac” collapses. Thus, static contact angles can be manipulated mechanically from 0° to >140° due to hysteresis and are therefore uninformative. We also provide recommendations and best practices for wetting experiments, which may find use in applications that use these alloys such as soft electronics, composites, and microfluidics.

36 MATERIALS SCIENCE↗

Contact Angle Measurements Using Sessile Drop and Micro-CT Data from Six Sandstones

Numerous sessile drop and micro-computed tomography (micro-CT) studies have been conducted to quantify Geologic Carbon Storage formation wettability by measuring static contact angles (θ); however, the influence of pore geometry remains unknown. In this work, six sandstones (Bandera Brown, Berea, Bentheimer, Mt. Simon, Navajo, and Nugget) are used to measure θ using the two aforementioned experimental methods at identical testing conditions (45°C and 12.41 MPa). The range of θ measured at in situ conditions (micro-CT) exceeds those the range at ex situ (sessile drop method) conditions for all sandstones. However, when droplets with more representative in situ diameters are analyzed, θ averages show ex situ θ exceed those of in situ θ. Pore geometry does influence local θ, but the size of ex situ droplets relative to pore size appears to influence θ. This is an important to consider for future sessile drop studies used for analysis of CO 2 behavior in carbon storage reservoirs.

36 MATERIALS SCIENCE↗

Sensitivity of magnetic field-line pitch angle measurements to sawtooth events in tokamaks

The sensitivity of the pitch angle profiles measured by the motional Stark effect (MSE) diagnostic to the evolution of the safety factor, q, profiles during the tokamak sawtooth events has been investigated for Korea Superconducting Tokamak Advanced Research (KSTAR). An analytic relation between the tokamak pitch angle, γ, and q estimates that Δγ ∼ 0.1° is required for detecting Δq ∼ 0.05 near the magnetic axis (not at the magnetic axis, though). The pitch angle becomes less sensitive to the same Δq for the middle and outer regions of the plasma (Δγ ∼ 0.5°). At the magnetic axis, it is not straightforward to directly relate the γ sensitivity to Δq since the gradient of γ(R), where R is the major radius of the tokamak, is involved. Many of the MSE data obtained from the 2015 KSTAR campaign, when calibrated carefully, can meet these requirements with the time integration down to 10 ms. The analysis with the measured data shows that the pitch angle profiles and their gradients near the magnetic axis can resolve the change of the q profiles including the central safety factor, q{sub 0}, during the sawtooth events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CO 2 –Brine Contact Angle Measurements on Navajo, Nugget, Bentheimer, Bandera Brown, Berea, and Mt. Simon Sandstones

In this study, contact angles were measured for CO 2 bubbles on six different sandstones (Navajo, Nugget, Bentheimer, Bandera Brown, Berea, and Mt. Simon) that could potentially represent properties of CO 2 storage depositional environments. The impacts of pressure and temperature were studied by focusing on the CO 2 phase behavior in three different scenarios: gaseous, liquid, and supercritical conditions. Despite controlling the sample preparation and cleanliness, CO 2 -brine equilibration conditions, and pressure and temperature, there were inconsistencies in contact angle trends that could largely be attributed to natural sample heterogeneity resulting from localized variations in topography, surface roughness, and mineral composition across the surface. Despite these variations, the analysis of 298 measurements from this study showed that 81% of the contact angles were below 40° representing strongly water-wet to (moderately) water-wet behaviors. Also, 17.3% of the measurements were between 40° and 60° (weakly water-wet) and primarily belonged to small CO 2 bubbles (< 500 μm) that were heavily impacted by localized surface heterogeneity in natural sandstone samples. Additionally, only 1.7% of the measurements had angles greater than 60° and could be classified as CO 2 -wet behavior, but these measurements occurred on extremely small bubbles (100-200 μm) that were very dependent on localized surface heterogeneity. While some of the detailed physics of the CO 2 -brine-sandstone interface is still poorly understood, from an application standpoint, the sandstones of this study were best characterized as strongly water-wet to (moderately) water-wet.

03 NATURAL GAS↗

Runaway electron plateau current profile reconstruction from synchrotron imaging and Ar-II line polarization angle measurements in DIII-D

Abstract Current profile reconstructions are obtained for high current ( I p ≃ 550 kA) post-disruption runaway electron (RE) plateau plasmas in DIII-D. Two novel methods of measuring the RE current profile in high-current RE plateaus are introduced and compared: localization of the q = 2 rational surface using visible synchrotron emission (SE) imaging and the measurement of the polarization angle of line-integrated Ar-II line emission. The two methods are found to be consistent with each other within the data uncertainties. Different simulations of the RE current profile are compared with the measurements: the toroidal fluid RE model is found to best fit the data, within the measurement uncertainties. In addition to introducing two novel methods to measure the RE current profile and validating present simulation capabilities, this work demonstrates that instabilities can grow at q = 2 and q = 1 surfaces without necessarily causing a RE final loss instability. Numerical simulations are also presented to elucidate the role of these instabilities on synchrotron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ contact angle measurements of liquid CO 2 , brine, and Mount Simon sandstone core using micro X-ray CT imaging, sessile drop, and Lattice Boltzmann modeling

Three techniques to measure and understand the contact angle, θ, of a CO 2 /brine/rock system relevant to geologic carbon storage were performed with Mount Simon sandstone. Traditional sessile drop measurements of CO 2 /brine on the sample were conducted and a water-wet system was observed, as is expected. A novel series of measurements inside of a Mount Simon core, using a micro X-ray computed tomography imaging system with the ability to scan samples at elevated pressures, was used to examine the θ of residual bubbles of CO 2 . Within the sandstone core the matrix appeared to be neutrally wetting, with an average θ around 90°. A large standard deviation of θ (20.8°) within the core was also observed. To resolve this discrepancy between experimental measurements, a series of Lattice Boltzmann model simulations were performed with differing intrinsic θ values. The model results with a θ = 80° were shown to match the core measurements closely, in both magnitude and variation. The small volume and complex geometry of the pore spaces that CO 2 was trapped in is the most likely explanation of this discrepancy between measured values, though further work is warranted.

42 ENGINEERING↗

Application of unsupervised deep learning to image segmentation and in-situ contact angle measurements in a CO 2 -water-rock system

Rock surface wettability is a critical property that regulates multiphase flows in porous media, which can be quantified using the surface contact angle (CA). X-ray micro-computed tomography (μCT) provides an effective approach to in-situ measurements of surface CAs. However, the CA measurement accuracy depends significantly on the quality of CT image segmentation, which is the clustering of CT pixels into separate phases. Inspired by this, we developed a deep learning (DL)-based CA measurement workflow. Motivated by the recent tremendous progress in unsupervised learning techniques and aiming to avoid expensive manual data annotations, an unsupervised DL pipeline for CT image segmentation was proposed and implemented, which includes unsupervised model training and post-processing. The unsupervised model training was driven by a novel loss function constrained with feature similarity and spatial continuity and implemented by iterative forward and backward paths; the former clustered the pixel-wise feature vectors extracted by convolution neural networks, whereas the latter updated the parameters using gradient descent. An over-segmentation strategy was adopted for model training. The post-processing steps based on agglomerative hierarchical clustering (AHC) were implemented to further merge the over-segmented model output to the desired cluster number, which is intended to improve the efficiency of image segmentation. The developed unsupervised DL pipeline was compared with other commonly-used image segmentation methods using pixel-wise and physics-based evaluation metrics on a synthetic raw-image dataset, which had a known ground truth. The unsupervised DL pipeline showed the best performance. Next, the segmented images were input to an automatic CA measurement tool, and the results were validated by comparisons with manual measurements. The CA values from the manual and automatic measurements showed similar distributions and statistical properties. The automatic measurement demonstrated a wider spectrum because of the much larger number of measurement data points. The primary novelty of the unsupervised DL pipeline developed in this study lies in the novel loss function and the over-segmentation strategy associated with AHC post-processing. Finally, the workflow has been proven an efficient tool for pore-scale wettability characterization, which has a wide range of applications in fundamental studies of multiphase flows in natural porous media, which have critical implications to geological carbon sequestration, hydrocarbon energy recovery, and contaminant transport in groundwater.

42 ENGINEERING↗

Systematic Oxidation of Polystyrene by Ultraviolet-Ozone, Characterized by Near-Edge X-ray Absorption Fine Structure and Contact Angle

The process of implanting oxygen in polystyrene (PS) via exposure to ultraviolet-ozone (UV-O) was systematically investigated using the characterization technique of near-edge X-ray absorption fine structure (NEXAFS). Samples of PS exposed to UV-O for 10-300 s and washed with isopropanol were analyzed using the carbon and oxygen K-edge NEXAFS partial electron yields, using various retarding bias voltages to depth-profile the oxygen penetration into the surface. Evaluation of reference polymers provided a scale to quantify the oxygen concentration implanted by UV-O treatment. We find that ozone initially reacts with the double bonds on the phenyl rings, forming carbonyl groups, but within 1 min of exposure, the ratio of double to single oxygen bonds stabilizes at a lower value. Oxygen penetrates the film with relative ease, creating a fairly uniform distribution of oxygen within at least the first 4 nm (the effective depth probed by NEXAFS here). Before oxygen accumulates in large concentrations, however, it preferentially degrades the uppermost layer of the film by removing oxygenated low-molecular-weight oligomers. The failure to accumulate high concentrations of oxygen is seen in the nearly constant carbon edge jump, the low concentration of oxygen even at 5 min exposure (58% of that in poly(4-acetoxystyrene), the polymer with the most similarities to UV-O-treated PS), and the relatively high contact angles. At 5 min exposure the oxygen concentration contains ca. 7 atomic % oxygen. The oxygen species that are implanted consist predominantly of single O-C bonds and double OC bonds but also include a small fraction of O-H. UV-O treatment leads a plateau after 2 min exposure in the water contact angle hysteresis, at a value of 67 {+-} 2, due primarily to chemical heterogeneity. Annealing above Tg allows oxygenated species to move short distances away from the surface but not diffuse further than 1-2 nm.

36 MATERIALS SCIENCE↗