Search NASA⌕ Search

SEARCH · Search NASA

Results for “Annulus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigating instabilities in a Rotating Detonation Combustor Operating with Natural Gas-Hydrogen Fuel Blend – Effect of Air Preheat and Annulus Width

Propagation characteristics of a detonation wave in an air-breathing Rotating Detonation Combustor (RDC) using natural gas-hydrogen fuel blends is presented in this paper. Short duration (~up to 6s) experiments were performed on a 152.4mm OD uncooled RDC with two different annulus gap widths (5.08mm and 7.62mm) over a range of equivalence ratios (0.6–1.0) at varying inlet air temperatures (~65°C-204°C) and natural gas content (up to 15%) with pre-combustion operating pressure slightly above ambient.It was observed that the RDC, with an annulus gap width of 5.08mm, was inherently unstable when natural gas (NG) was added to the hydrogen fuel while operating at pre-combustion pressures near ambient and at an inlet air temperature of 65°C. Increasing the annulus gap width to 7.62mm improved the stability of the detonation wave at similar temperatures and pressure permitting operation with as much as 5% NG by volume. While observed speeds of the detonation waves were still below theoretical values, an increase in inlet air temperature reduced the variability in wave speed. The frequency analysis thus explored in this study is an effort to quantify detonation instability in an RDC under varying operational envelope. The data presented is relevant towards developing strategies to sustain a stable detonation wave in an RDC using natural gas for land based power generation.

Roy, Arnab↗

Establishing a silica gel zone in well annulus and evaluating its performance in blocking vertical water flow

Wells are often constructed for monitoring purposes with relatively long screen lengths (e.g., >10 m). Vertical water flows can occur within the artificial or natural filterpack annulus that surrounds the screened interval, bypassing packer assemblies installed inside the wellbore. Attempts to isolate discrete vertical zones during groundwater sampling are unsuccessful when annular flow occurs and lead to remedy decisions based on biased or incorrect interpretations. Blocking vertical annular water flow and contaminant transport will help obtain more accurate concentrations of contaminants from sampling in targeted depth intervals. The application of silica gels formed from the injected colloidal silica CS suspensions is a novel approach to minimize or prevent movement of vertical movement of groundwater in the surrounding filterpack annulus. In this work, we tested the feasibility of injecting CS suspensions to target locations and developed a modified CS formulation that is injectable and prevents gravity sinking. We studied the distribution and penetration of silica gel at laboratory scale in mock well annulus with surrounding formations. We evaluated the performance of the silica gel in blocking vertical water flow in the annulus and in minimizing chemical transport through the gel zone. CS suspension formulations have been defined that are ready for injection, stay in target locations, and form gel within desired time frames. Injection of CS suspensions achieved uniform distribution in a well annulus filter pack, fully occupied the annulus pore space, and penetrated the formation surrounding the filter packer with a sufficient distance to create a hydraulic annular seal when the injection was applied at a sufficient rate. The depth of penetration into the formation was dependent on the permeability contrast between the filter pack and the surrounding formation. Silica gel that formed in the annulus blocked vertical water flow and stopped the chemical transport through the gel zone. In conclusion, this research reveals that using CS suspension injection and sequential gelation (CS-GEL) is a promising technology for blocking vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

Colloidal silica suspension↗

Saturation of SERCA's lipid annulus may protect against its thermal inactivation

The sarco(endo)plasmic reticulum Ca{sup 2+}-ATPase (SERCA) pumps are integral membrane proteins that catalyze the active transport of Ca{sup 2+} into the sarcoplasmic reticulum, thereby eliciting muscle relaxation. SERCA pumps are highly susceptible to oxidative damage, and cytoprotection of SERCA dampens thermal inactivation and is a viable therapeutic strategy in combating diseases where SERCA activity is impaired, such as muscular dystrophy. Here, we sought to determine whether increasing the percent of saturated fatty acids (SFA) within SERCA's lipid annulus through diet could protect SERCA pumps from thermal inactivation. Female Wistar rats were fed either a semi-purified control diet (AIN93G, 7% soybean oil by weight) or a modified AIN93G diet containing high SFA (20% lard by weight) for 17 weeks. Soleus muscles were extracted and SERCA lipid annulus and activity under thermal stress were analyzed. Our results show that SERCA's lipid annulus is abundant with short-chain (12–14 carbon) fatty acids, which corresponds well with SERCA's predicted bilayer thickness of 21 Å. Under control-fed conditions, SERCA's lipid annulus was already highly saturated (79%), and high-fat feeding did not increase this any further. High-fat feeding did not mitigate the reductions in SERCA activity seen with thermal stress; however, correlational analyses revealed significant and strong associations between % SFA and thermal stability of SERCA activity with greater %SFA being associated with lower thermal inactivation and greater % polyunsaturation and unsaturation index being associated with increased thermal inactivation. Altogether, these findings show that SERCA's lipid annulus may influence its susceptibility to oxidative damage, which could have implications in muscular dystrophy and age-related muscle wasting. - Highlights: • SERCA's lipid annulus in rat soleus was measured after immunoconcentration. • Short fatty acid chains surround SERCA and may ensure optimal hydrophobic matching. • SERCA's annulus is highly saturated in control-fed and high-fat fed rats. • Greater saturation associates with small levels of thermal inactivation. • Greater unsaturation associates with large levels of thermal inactivation.

60 APPLIED LIFE SCIENCES↗

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flow regimes in a shallow rotating cylindrical annulus with temperature gradients imposed on the horizontal boundaries

Experimental flow regime diagrams are determined for a new rotating cylindrical annulus configuration which permits a measure of control over the internal vertical temperature gradient. The new annulus has radial temperature gradients imposed on plane horizontal thermally conducting endwalls (with the cylindrical sidewalls as insulators) and is considered to be more relevant to atmospheric dynamics studies than the classical cylindrical annulus. Observations have revealed that, in addition to the axisymmetric flow and nonaxisymmetric baroclinic wave flow which occur in the classical annulus, two additional nonaxisymmetric flow types occur in the new annulus: boundary-layer thermal convection and deep thermal convection. Flow regime diagrams for three different values of the imposed vertical temperature difference are presented, and explanations for the flow transitions are offered. The new annulus provides scientific backup for the proposed Atmospheric General Circulation Experiment for Spacelab. The apparatus diagram is included.

Hathaway, D. H.↗

Axial-slot Air Admission for Controlling Performance of a One-quarter-annulus Turbojet Combustor and Comparison with Complete Engine

An investigation of a single-annulus turbojet combustor with slot-type air admission was conducted to demonstrate the application of certain design principles to the control of outlet-gas temperature distributions. Comparisons of performance of a one-quarter-annulus combustor (duct-type installation) and a full-annulus combustor (obtained in a full-scale turbojet engine) are presented to indicate the applicability of results obtained from combustion studies conducted in duct-type installations. A reasonable correlation existed between the performance of the one-quarter-annulus and full-annulus combustors except for temperature distribution. Sufficient trends did exist which made it possible to predict temperature distributions for the engine, although absolute correlation did not exist. A radial temperature distribution similar to that required for a given engine was obtained using a one-quarter-annulus duct-type setup to predict results.

COMBUSTION--TURBINE ENGINES↗

The Dark Annulus of a Drop in a Hele-Shaw Cell Is Caused by the Refraction of Light through Its Meniscus

Knowing the meniscus shape of confined drops is important for understanding how they make first contact and then coalesce. When imaged from the top view by brightfield microscopy, a liquid drop (e.g., corn syrup) confined in a Hele-Shaw cell, surrounded by immiscible liquid (e.g., mineral oil), had a dark annulus, and the width of the annulus decreased with increasing concentration of corn syrup. Since the difference in the annulus width was presumed to be related to the meniscus shape of the drops, three-dimensional images of the drops with different concentrations were obtained using confocal fluorescence microscopy, and their cross-sectional meniscus profile was determined by image processing. The meniscus of the drops remained circular despite varying concentration. Since the refractive index of corn syrup increased with concentration, while the surface tension coefficient between corn syrup and mineral oil remained unchanged, the observed change in the annulus width was then attributed to the refraction of light passing through the drop’s meniscus. As such, a ray optics model was developed, which predicted that the annulus width of the drop would decrease as the refractive index of the drop approached that of the surrounding liquid. Therefore, the dark annulus of the drops in the Hele-Shaw cell was caused by the refraction of light passing through the circular meniscus of the drop.

Sangjin Ryu↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

An Inverse Heat Conduction Algorithm Used to Calculate the Temperatures on the Inner and Outer Cylindrical Surfaces of an HMX-based PBX Explosive Annulus

In this work, a new Inverse Heat Conduction (IHC) algorithm is applied to estimate the surface temperatures at twelve locations on the inner and outer cylindrical boundaries of an HMX-based Plastic Bonded Explosive (PBX) annulus. This IHC algorithm was developed in references using a set of Direct Heat Conduction (DHC) solutions and a temperature correction method. The DHC solutions were calculated using a Galerkin based finite element (FE) method. This HMX based PBX annulus was used in the Large Scale Annular Cookoff (LSAC) experiment, Shot 5. The reason Shot 5 was chosen as a prototype mathematical model for this study is that the temperature was measured at eighteen locations in the midplane of the HMX-based PBX annulus. In addition, this annulus underwent an experimental thermal ignition and a deflagration that caused a thermal explosion and the disassembly of the experiment. The objective of this study is to describe how the application of the temperature correction algorithm produced the convergence of the DHC solutions to the measured temperatures at twelve internal locations in the midplane of the HMX-based PBX annulus.

36 MATERIALS SCIENCE↗

Beyond Annulus Size: Imaging for TAVR Planning

Purpose of Review: The aim of this article is to review the role of imaging in pre-procedural assessment prior to transcatheter aortic valve replacement (TAVR)—with a focus on relevant anatomic findings apart from the size of the aortic annulus. Recent Findings: Pre-procedure imaging prior to TAVR heavily emphasizes assessment of the aortic annulus for appropriate valve sizing, with computed tomography angiography (CTA) emerging as the test of choice due to its ability to assess not only the aortic annulus but also the thoracoabdominal aorta and peripheral vasculature. Some patients with underlying kidney disease may be at increased risk of renal dysfunction following contrast-enhanced CTA; however, alternate imaging techniques can be performed to mitigate this risk such as magnetic resonance imaging. Summary: Familiarity with underlying anatomic variability and pathology relevant to TAVR implantation in addition to annulus size, as well as imaging approaches in patients with renal dysfunction, will allow radiologists to better contribute to multidisciplinary discussion for potential TAVR candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation and viscous dissipation effect on square porous annulus

The present study is carried out to investigate the effect of radiation and viscous dissipation in a square porous annulus subjected to outside hot T{sub h} and inside cold T{sub c} temperature. The square annulus has a hollow section of dimension D×D at the interior of annulus. The flow is assumed to obey Darcy law. The governing equations are non-dimensionalised and solved with the help of finite element method. Results are discussed with respect to viscous dissipation parameter, radiation parameter and size of the hollow section of annulus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of mean velocity in the annulus wall region at the exit of turbomachinery rotor passage

This paper reports the experimental study of the three-dimensional characteristics of the mean velocity in the annulus-wall boundary layer and wake mixing region of a moderately loaded compressor rotor blade. The measurements reported were obtained using a three-sensor hot-wire probe at the exit of the rotor. They consisted of tangential surveys at several axial and radial locations downstream of the compressor rotor blade passage. The variation of the streamwise, normal, and radial velocity profiles and their decay characteristics are derived from this data. The measurements reveal the highly complex and three-dimensional nature of the annulus-wall flow field and the nature of the interaction of the annulus-wall boundary layer, the blade boundary layers and wake, and the secondary flow associated with the annulus-wall region.

Davino, R.↗

Turbulence characteristics in the annulus-wall boundary layer and wake mixing region of a compressor rotor exit

The flow at the exit of a turbomachinery rotor near the annulus wall is three-dimensional with a varying degree of turbulence and nonisotropic characteristics. The characteristics of the turbulence vary considerably with radial and axial location, blade loading, Reynolds number, free-stream turbulence, and the rotor blade geometry. This paper is concerned with the turbulence properties near the annulus wall region of a moderately loaded compressor blade. The variation of the streamwise, normal, and radial intensities as well as the stresses across the wake, its profile and decay characteristics, were determined with a tri-axial hot-wire probe in the stationary frame of reference. The turbulence characteristics in the annulus-wall region of the rotor exit were found to be highly complex due to the interaction of the blade wake and the annulus wall.

Davino, R.↗

Analysis of shape and motion of the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction

The shape and dynamics of the mitral annulus of 10 patients without heart disease (controls), 3 patients with dilated cardiomyopathy, and 5 patients with hypertrophic obstructive cardiomyopathy and normal systolic function were analyzed by transesophageal echocardiography and 3-dimensional reconstruction. Mitral annular orifice area, apico-basal motion of the annulus, and nonplanarity were calculated over time. Annular area was largest in end diastole and smallest in end systole. Mean areas were 11.8 +/- 2.5 cm(2) (controls), 15.2 +/- 4.2 cm(2) (dilated cardiomyopathy), and 10.2 +/- 2.4 cm(2) (hypertrophic cardiomyopathy) (P = not significant). After correction for body surface, annuli from patients with normal left ventricular function were smaller than annuli from patients with dilated cardiomyopathy (5.9 +/- 1.2 cm(2)/m(2) vs 7.7 +/- 1.0 cm(2)/m(2); P <.02). The change in area during the cardiac cycle showed significant differences: 23.8% +/- 5.1% (controls), 13.2% +/- 2.3% (dilated cardiomyopathy), and 32.4% +/- 7.6% (hypertrophic cardiomyopathy) (P <.001). Apico-basal motion was highest in controls, followed by those with hypertrophic obstructive and dilated cardiomyopathy (1.0 +/- 0.3 cm, 0.8 +/- 0.2 cm, 0.3 +/- 0.2 cm, respectively; P <.01). Visual inspection and Fourier analysis showed a consistent pattern of anteroseptal and posterolateral elevations of the annulus toward the left atrium. In conclusion, although area changes and apico-basal motion of the mitral annulus strongly depend on left ventricular systolic function, nonplanarity is a structural feature preserved throughout the cardiac cycle in all three groups.

Non-NASA Center↗

Tank 14H Annulus Samples Analyses

Savannah River Mission Completion (SRMC) Waste Removal and Tank Closure has requested that Savannah River National Laboratory (SRNL) perform characterization analyses of Tank 14H annulus samples in support of closure activities specifically annulus cleaning. SRMC requested assistance due to encountering relatively insoluble solids while washing the annulus with water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection

We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

54 ENVIRONMENTAL SCIENCES↗

Annular Pressure Buildup Calculation When Annulus Contains Gas

During the execution of technological operations such as multiple pressure relief or foam separation during well injection, a gas column can form at the wellhead in the annular space, leading to annular pressure buildup (APB). Based on the theory of heat transfer, a model was proposed for calculating the wellbore heat transfer during production. Taking into account the expansion and compression of the fluid, changes in the wellhead volume, the thermodynamic characteristics of the liquid, and the equation of state of the gas, APB calculations were performed. Based on these parameters, the influence of the gas column height on APB was evaluated. The results of the studies show that the coefficients of expansion and compressibility in the annulus depend on density, pressure and temperature: the higher the productivity of the gas well, the higher the temperature and pressure in the annulus; the greater the height of the gas column, the lower the pressure at the wellhead. For a well with a productivity of 30· 10{sup 4} m{sup 3}/day and gas column height of 70 m in the annulus, the APB is reduced to atmospheric pressure. Studies of the model for calculating APB of the annular trapped gas provide a theoretical basis for developing optimal technological parameters for the operation of gas wells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water absorption and shrinkage behaviour of early-age cement in wellbore annulus

Controlling cement shrinkage in a wellbore is well-known as being important in maintaining its integrity. Although numerous laboratory experiments on the water absorption and shrinkage behaviour of oil well cement have been reported in the past, such behaviour in the wellbore annulus with consideration of pore water migration from the surrounding formation has seldom been examined. In this study, using a cement shrinkage model calibrated against available experimental data, a coupled hydromechanical finite element analysis of a cement-formation model is conducted to simulate the water migration, absorption and shrinkage behaviour of early-age cement placed in the annulus of a wellbore. The objectives of this study are (i) to identify the threshold permeability value of the formation above which there is no longer a bottleneck for pore water to flow into the cement and (ii) to estimate a reasonable range of cement bulk shrinkage volume in wellbore annulus geometry. Results show that the threshold permeability of the formation would be around 0.1 mD for three different types of cement examined in this study: Class G cement, rapid setting (RS) cement and Schlumberger optimized particle size distribution (OPSD) technology cement. The bulk shrinkage volume varies from 0.01% to 2.4% depending on cement type and formation permeability (1 mD to 0.1 μD). Finally, the proposed methodology facilitates the simulation of water migration/absorption and shrinkage behaviour of well cement in different formations.

02 PETROLEUM↗