Search NASA⌕ Search

SEARCH · Search NASA

Results for “Annulus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigating instabilities in a Rotating Detonation Combustor Operating with Natural Gas-Hydrogen Fuel Blend – Effect of Air Preheat and Annulus Width

Propagation characteristics of a detonation wave in an air-breathing Rotating Detonation Combustor (RDC) using natural gas-hydrogen fuel blends is presented in this paper. Short duration (~up to 6s) experiments were performed on a 152.4mm OD uncooled RDC with two different annulus gap widths (5.08mm and 7.62mm) over a range of equivalence ratios (0.6–1.0) at varying inlet air temperatures (~65°C-204°C) and natural gas content (up to 15%) with pre-combustion operating pressure slightly above ambient.It was observed that the RDC, with an annulus gap width of 5.08mm, was inherently unstable when natural gas (NG) was added to the hydrogen fuel while operating at pre-combustion pressures near ambient and at an inlet air temperature of 65°C. Increasing the annulus gap width to 7.62mm improved the stability of the detonation wave at similar temperatures and pressure permitting operation with as much as 5% NG by volume. While observed speeds of the detonation waves were still below theoretical values, an increase in inlet air temperature reduced the variability in wave speed. The frequency analysis thus explored in this study is an effort to quantify detonation instability in an RDC under varying operational envelope. The data presented is relevant towards developing strategies to sustain a stable detonation wave in an RDC using natural gas for land based power generation.

Roy, Arnab↗

Establishing a silica gel zone in well annulus and evaluating its performance in blocking vertical water flow

Wells are often constructed for monitoring purposes with relatively long screen lengths (e.g., >10 m). Vertical water flows can occur within the artificial or natural filterpack annulus that surrounds the screened interval, bypassing packer assemblies installed inside the wellbore. Attempts to isolate discrete vertical zones during groundwater sampling are unsuccessful when annular flow occurs and lead to remedy decisions based on biased or incorrect interpretations. Blocking vertical annular water flow and contaminant transport will help obtain more accurate concentrations of contaminants from sampling in targeted depth intervals. The application of silica gels formed from the injected colloidal silica CS suspensions is a novel approach to minimize or prevent movement of vertical movement of groundwater in the surrounding filterpack annulus. In this work, we tested the feasibility of injecting CS suspensions to target locations and developed a modified CS formulation that is injectable and prevents gravity sinking. We studied the distribution and penetration of silica gel at laboratory scale in mock well annulus with surrounding formations. We evaluated the performance of the silica gel in blocking vertical water flow in the annulus and in minimizing chemical transport through the gel zone. CS suspension formulations have been defined that are ready for injection, stay in target locations, and form gel within desired time frames. Injection of CS suspensions achieved uniform distribution in a well annulus filter pack, fully occupied the annulus pore space, and penetrated the formation surrounding the filter packer with a sufficient distance to create a hydraulic annular seal when the injection was applied at a sufficient rate. The depth of penetration into the formation was dependent on the permeability contrast between the filter pack and the surrounding formation. Silica gel that formed in the annulus blocked vertical water flow and stopped the chemical transport through the gel zone. In conclusion, this research reveals that using CS suspension injection and sequential gelation (CS-GEL) is a promising technology for blocking vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

Colloidal silica suspension↗

Saturation of SERCA's lipid annulus may protect against its thermal inactivation

The sarco(endo)plasmic reticulum Ca{sup 2+}-ATPase (SERCA) pumps are integral membrane proteins that catalyze the active transport of Ca{sup 2+} into the sarcoplasmic reticulum, thereby eliciting muscle relaxation. SERCA pumps are highly susceptible to oxidative damage, and cytoprotection of SERCA dampens thermal inactivation and is a viable therapeutic strategy in combating diseases where SERCA activity is impaired, such as muscular dystrophy. Here, we sought to determine whether increasing the percent of saturated fatty acids (SFA) within SERCA's lipid annulus through diet could protect SERCA pumps from thermal inactivation. Female Wistar rats were fed either a semi-purified control diet (AIN93G, 7% soybean oil by weight) or a modified AIN93G diet containing high SFA (20% lard by weight) for 17 weeks. Soleus muscles were extracted and SERCA lipid annulus and activity under thermal stress were analyzed. Our results show that SERCA's lipid annulus is abundant with short-chain (12–14 carbon) fatty acids, which corresponds well with SERCA's predicted bilayer thickness of 21 Å. Under control-fed conditions, SERCA's lipid annulus was already highly saturated (79%), and high-fat feeding did not increase this any further. High-fat feeding did not mitigate the reductions in SERCA activity seen with thermal stress; however, correlational analyses revealed significant and strong associations between % SFA and thermal stability of SERCA activity with greater %SFA being associated with lower thermal inactivation and greater % polyunsaturation and unsaturation index being associated with increased thermal inactivation. Altogether, these findings show that SERCA's lipid annulus may influence its susceptibility to oxidative damage, which could have implications in muscular dystrophy and age-related muscle wasting. - Highlights: • SERCA's lipid annulus in rat soleus was measured after immunoconcentration. • Short fatty acid chains surround SERCA and may ensure optimal hydrophobic matching. • SERCA's annulus is highly saturated in control-fed and high-fat fed rats. • Greater saturation associates with small levels of thermal inactivation. • Greater unsaturation associates with large levels of thermal inactivation.

60 APPLIED LIFE SCIENCES↗

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

An Inverse Heat Conduction Algorithm Used to Calculate the Temperatures on the Inner and Outer Cylindrical Surfaces of an HMX-based PBX Explosive Annulus

In this work, a new Inverse Heat Conduction (IHC) algorithm is applied to estimate the surface temperatures at twelve locations on the inner and outer cylindrical boundaries of an HMX-based Plastic Bonded Explosive (PBX) annulus. This IHC algorithm was developed in references using a set of Direct Heat Conduction (DHC) solutions and a temperature correction method. The DHC solutions were calculated using a Galerkin based finite element (FE) method. This HMX based PBX annulus was used in the Large Scale Annular Cookoff (LSAC) experiment, Shot 5. The reason Shot 5 was chosen as a prototype mathematical model for this study is that the temperature was measured at eighteen locations in the midplane of the HMX-based PBX annulus. In addition, this annulus underwent an experimental thermal ignition and a deflagration that caused a thermal explosion and the disassembly of the experiment. The objective of this study is to describe how the application of the temperature correction algorithm produced the convergence of the DHC solutions to the measured temperatures at twelve internal locations in the midplane of the HMX-based PBX annulus.

36 MATERIALS SCIENCE↗

Beyond Annulus Size: Imaging for TAVR Planning

Purpose of Review: The aim of this article is to review the role of imaging in pre-procedural assessment prior to transcatheter aortic valve replacement (TAVR)—with a focus on relevant anatomic findings apart from the size of the aortic annulus. Recent Findings: Pre-procedure imaging prior to TAVR heavily emphasizes assessment of the aortic annulus for appropriate valve sizing, with computed tomography angiography (CTA) emerging as the test of choice due to its ability to assess not only the aortic annulus but also the thoracoabdominal aorta and peripheral vasculature. Some patients with underlying kidney disease may be at increased risk of renal dysfunction following contrast-enhanced CTA; however, alternate imaging techniques can be performed to mitigate this risk such as magnetic resonance imaging. Summary: Familiarity with underlying anatomic variability and pathology relevant to TAVR implantation in addition to annulus size, as well as imaging approaches in patients with renal dysfunction, will allow radiologists to better contribute to multidisciplinary discussion for potential TAVR candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation and viscous dissipation effect on square porous annulus

The present study is carried out to investigate the effect of radiation and viscous dissipation in a square porous annulus subjected to outside hot T{sub h} and inside cold T{sub c} temperature. The square annulus has a hollow section of dimension D×D at the interior of annulus. The flow is assumed to obey Darcy law. The governing equations are non-dimensionalised and solved with the help of finite element method. Results are discussed with respect to viscous dissipation parameter, radiation parameter and size of the hollow section of annulus.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tank 14H Annulus Samples Analyses

Savannah River Mission Completion (SRMC) Waste Removal and Tank Closure has requested that Savannah River National Laboratory (SRNL) perform characterization analyses of Tank 14H annulus samples in support of closure activities specifically annulus cleaning. SRMC requested assistance due to encountering relatively insoluble solids while washing the annulus with water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection

We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

54 ENVIRONMENTAL SCIENCES↗

Annular Pressure Buildup Calculation When Annulus Contains Gas

During the execution of technological operations such as multiple pressure relief or foam separation during well injection, a gas column can form at the wellhead in the annular space, leading to annular pressure buildup (APB). Based on the theory of heat transfer, a model was proposed for calculating the wellbore heat transfer during production. Taking into account the expansion and compression of the fluid, changes in the wellhead volume, the thermodynamic characteristics of the liquid, and the equation of state of the gas, APB calculations were performed. Based on these parameters, the influence of the gas column height on APB was evaluated. The results of the studies show that the coefficients of expansion and compressibility in the annulus depend on density, pressure and temperature: the higher the productivity of the gas well, the higher the temperature and pressure in the annulus; the greater the height of the gas column, the lower the pressure at the wellhead. For a well with a productivity of 30· 10{sup 4} m{sup 3}/day and gas column height of 70 m in the annulus, the APB is reduced to atmospheric pressure. Studies of the model for calculating APB of the annular trapped gas provide a theoretical basis for developing optimal technological parameters for the operation of gas wells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water absorption and shrinkage behaviour of early-age cement in wellbore annulus

Controlling cement shrinkage in a wellbore is well-known as being important in maintaining its integrity. Although numerous laboratory experiments on the water absorption and shrinkage behaviour of oil well cement have been reported in the past, such behaviour in the wellbore annulus with consideration of pore water migration from the surrounding formation has seldom been examined. In this study, using a cement shrinkage model calibrated against available experimental data, a coupled hydromechanical finite element analysis of a cement-formation model is conducted to simulate the water migration, absorption and shrinkage behaviour of early-age cement placed in the annulus of a wellbore. The objectives of this study are (i) to identify the threshold permeability value of the formation above which there is no longer a bottleneck for pore water to flow into the cement and (ii) to estimate a reasonable range of cement bulk shrinkage volume in wellbore annulus geometry. Results show that the threshold permeability of the formation would be around 0.1 mD for three different types of cement examined in this study: Class G cement, rapid setting (RS) cement and Schlumberger optimized particle size distribution (OPSD) technology cement. The bulk shrinkage volume varies from 0.01% to 2.4% depending on cement type and formation permeability (1 mD to 0.1 μD). Finally, the proposed methodology facilitates the simulation of water migration/absorption and shrinkage behaviour of well cement in different formations.

02 PETROLEUM↗

Investigating Instabilities in a Rotating Detonation Combustor Operating With Natural Gas–Hydrogen Fuel Blend—Effect of Air Preheat and Annulus Width

Propagation characteristics of a detonation wave in an air-breathing rotating detonation combustor (RDC) using natural gas (NG)–hydrogen fuel blends is presented in this paper. Short-duration (~up to 6 s) experiments were performed on a 152.4 mm OD uncooled RDC with two different annulus gap widths (5.08 mm and 7.62 mm) over a range of equivalence ratios (0.6–1.0) at varying inlet air temperatures (~65–204 °C) and NG content (up to 15%) with precombustion operating pressure slightly above ambient. It was observed that the RDC, with an annulus gap width of 5.08 mm, was inherently unstable when NG was added to the hydrogen fuel while operating at precombustion pressures near ambient and at an inlet air temperature of 65 °C. Increasing the annulus gap width to 7.62 mm improved the stability of the detonation wave at similar temperatures and pressure permitting operation with as much as 5% NG by volume. While observed speeds of the detonation waves were still below theoretical values, an increase in inlet air temperature reduced the variability in wave speed. The frequency analysis thus explored in this study is an effort to quantify detonation instability in an RDC under varying operational envelope. Finally, the data presented are relevant toward developing strategies to sustain a stable detonation wave in an RDC using NG for land-based power generation.

08 HYDROGEN↗

First bulk and surface results for the ATLAS ITk Strip stereo annulus sensors

A novel microstrip sensor geometry, the stereo annulus, has been developed for use in the end-cap of the ATLAS experiment’s strip tracker upgrade at the HL-LHC. Its first implementation is in the ATLAS12EC sensors, a large-area, radiation-hard, single-sided, AC-coupled, n + -in-p design produced by the ITk Strip Sensor Collaboration and fabricated by Hamamatsu Photonics in early 2017. The results of the initial testing of two ATLAS12EC batches are presented here with a comparison to specification. The potential of the new sensor shape to reinvigorate endcap strip tracking is explained and its effects on sensor performance are isolated by comparing the bulk mechanical and electrical properties of the new sensor to the previous iteration of prototype, the conventional barrel ATLAS12A sensor. The surface properties of the new sensor are evaluated for full-size unirradiated sensors as well as for mini sensors unirradiated and irradiated with protons up to a fluence of 2.2 x 10 15 n eq cm -2 . The results show that the new stereo annulus ATLAS12EC sensors exhibit excellent performance and the expected irradiation evolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional development of tensile pre-strained annulus fibrosus cells for tissue regeneration: An in-vitro study

Prior research has investigated the immediate response after application of tensile strain on annulus fibrosus (AF) cells for the past decade. Although mechanical strain can produce either catabolic or anabolic consequences to the cell monolayer, little is known on how to translate these findings into further tissue engineering applications. Till to date, the application and effect of tensile pre-strained cells to construct a three-dimensional (3D) AF tissue remains unknown. This study aims to investigate the effect of tensile pre-strained exposure of 1 to 24 h on the development of AF pellet culture for 3 weeks. Equibiaxial cyclic tensile strain was applied on AF monolayer cells over a period of 24 h, which was subsequently developed into a cell pellet. Investigation on cellular proliferation, phenotypic gene expression, and histological changes revealed that tensile pre-strain for 24 h had significant and lasting effect on the AF tissue development, with enhanced cell proliferation, and up-regulation of collagen type I, II, and aggrecan expression. Our results demonstrated the regenerative ability of AF cell pellets subjected to 24 h tensile pre-straining. Knowledge on the effects of tensile pre-strain exposure is necessary to optimize AF development for tissue reconstruction. Moreover, the tensile pre-strained cells may further be utilized in either cell therapy to treat mild disc degeneration disease, or the development of a disc construct for total disc replacement. - Highlights: • Establishment of tensile pre-strained cell line population for annulus development. • Tensile strain limits collagen gene expression declination in monolayer culture. • Tensile pre-strained cells up-regulate their matrix protein in 3D pellet culture.

60 APPLIED LIFE SCIENCES↗

Extraordinary acoustic transmission through annuluses in air and its applications in acoustic beam splitter and concentrator

We report an extraordinary acoustic transmission through two layer annuluses made of metal cylinders in air both numerically and experimentally. The effect arises from the enhancement and reconstruction of the incident source induced by different Mie-resonance modes of the annuluses. The proposed system takes advantages of the consistency in the waveform between the input and output waves, the high amplitude amplification of output waves, and the easy adjustment of structure. More interestingly, we investigate the applications of the extraordinary acoustic transmission in the acoustic beam splitter and acoustic concentrator. Our finding should have an impact on ultrasonic applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Type 2 diabetes impairs annulus fibrosus fiber deformation and rotation under disc compression in the University of California Davis type 2 diabetes mellitus (UCD-T2DM) rat model

Abstract Understanding the biomechanical behavior of the intervertebral disc is crucial for studying disease mechanisms and developing tissue engineering strategies for managing disc degeneration. We used synchrotron small-angle X-ray scattering to investigate how changes to collagen behavior contribute to alterations in the disc’s ability to resist compression. Coccygeal motion segments from 6-month-old lean Sprague-Dawley rats ( n=7) and diabetic obese University of California Davis type 2 diabetes mellitus (UCD-T2DM) rats ( n=6, diabetic for 68±7 days) were compressed during simultaneous synchrotron scanning to measure collagen strain at the nanoscale (beamline 7.3.3 of the Advanced Light Source). After compression, the annulus fibrosus was assayed for nonenzymatic cross-links. In discs from lean rats, resistance to compression involved two main energy-dissipation mechanisms at the nanoscale: (1) rotation of the two groups of collagen fibrils forming the annulus fibrosus and (2) straightening (uncrimping) and stretching of the collagen fibrils. In discs from diabetic rats, both mechanisms were significantly impaired. Specifically, diabetes reduced fibril rotation by 31% and reduced collagen fibril strain by 30% (compared to lean discs). The stiffening of collagen fibrils in the discs from diabetic rats was consistent with a 31% higher concentration of nonenzymatic cross-links and with evidence of earlier onset plastic deformations such as fibril sliding and fibril–matrix delamination. These findings suggest that fibril reorientation, stretching, and straightening are key deformation mechanisms that facilitate whole-disc compression, and that type 2 diabetes impairs these efficient and low-energy elastic deformation mechanisms, thereby altering whole-disc behavior and inducing the earlier onset of plastic deformation.

Rosenberg, James L.↗

241-AZ Farm Annulus Extent of Condition Baseline Inspection

This report provides the results of the comprehensive annulus visual inspection for tanks 241- AZ-101 and 241-AZ-102 performed in fiscal year 2013. The inspection established a baseline covering about 95 percent of the annulus floor for comparison with future inspections. Any changes in the condition are also included in this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗