Search NASA⌕ Search

SEARCH · Search NASA

Results for “Apodization functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DESIGN OF MIRRORS AND APODIZATION FUNCTIONS IN PHASE-INDUCED AMPLITUDE APODIZATION SYSTEMS

Phase-induced amplitude apodization (PIAA) coronagraphs are a promising technology for imaging exoplanets, with the potential to detect Earth-like planets around Sun-like stars. A PIAA system nominally consists of a pair of mirrors that reshape incident light without attenuation, coupled with one or more apodizers to mitigate diffraction effects or provide additional beam shaping to produce a desired output profile. We present a set of equations that allow apodizers to be chosen for any given pair of mirrors, or conversely mirror shapes chosen for given apodizers, to produce an arbitrary amplitude profile at the output of the system. We show how classical PIAA systems may be designed by this method and present the design of a novel four-mirror system with higher throughput than a standard two-mirror system. We also discuss the limitations due to diffraction and the design steps that may be taken to mitigate them.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance optimization of apodized FBG-based temperature sensors in single and quasi-distributed DWDM systems with new and different apodization profiles

In this work, different FBG temperature sensors are designed and evaluated with various apodization profiles. Evaluation is done under a wide range of controlling design parameters like sensor length and refractive index modulation amplitude, targeting a remarkable temperature sensing performance. New judgment techniques are introduced such as apodization window roll-off rate, asymptotic sidelobe (SL) decay level, number of SLs, and average SL level (SLav). Evaluation techniques like reflectivity, Full width at Half Maximum (FWHM), and Sidelobe Suppression Ratio (SLSR) are also used. A “New” apodization function is proposed, which achieves better performance like asymptotic decay of 18.4 dB/nm, high SLSR of 60 dB, high channel isolation of 57.9 dB, and narrow FWHM less than 0.15 nm. For a single accurate temperature sensor measurement in extensive noisy environment, optimum results are obtained by the Nuttall apodization profile and the new apodization function, which have remarkable SLSR. For a quasi-distributed FBG temperature sensor the Barthann and the new apodization profiles obtain optimum results. Barthann achieves a high asymptotic decay of 40 dB/nm, a narrow FWHM (less than 25 GHZ), a very low SLav of −45.3 dB, high isolation of 44.6 dB, and a high SLSR of 35 dB. The new apodization function achieves narrow FWHM of 0.177 nm, very low SL of −60.1, very low SLav of −63.6 dB, and very high SLSR of −57.7 dB. A study is performed on including an unapodized sensor among apodized sensors in a quasi-distributed sensing system. Finally, an isolation examination is performed on all the discussed apodizations and a linear relation between temperature and the Bragg wavelength shift is observed experimentally and matched with the simulated results.

36 MATERIALS SCIENCE↗

ANALYTIC MODELING OF STARSHADES

External occulters, otherwise known as starshades, have been proposed as a solution to one of the highest priority yet technically vexing problems facing astrophysics-the direct imaging and characterization of terrestrial planets around other stars. New apodization functions, developed over the past few years, now enable starshades of just a few tens of meters diameter to occult central stars so efficiently that the orbiting exoplanets can be revealed and other high-contrast imaging challenges addressed. In this paper, an analytic approach to the analysis of these apodization functions is presented. It is used to develop a tolerance analysis suitable for use in designing practical starshades. The results provide a mathematical basis for understanding starshades and a quantitative approach to setting tolerances.

79 ASTRONOMY AND ASTROPHYSICS↗

High Resolution Data Analysis: Plans and Prospects [Book Chapter]

Herein, a report on the progress on the high resolution data analysis of the ADMX experimental results is presented. In this paper, tools are developed and tested on a blind injection mimicking a Maxwellian like signal in the frequency domain. This blind injection will be used as a test bed which can be later implemented on all the high resolution data. The high resolution data is stored in the Fermilab server. In this analysis a PostgreSQL query was made to ensure the blind injection is in the middle of the frequency spectrum and 19 such files were found. The time series data is read using a c++ program. An apodization function is applied on the time series data and zero filled to reduce the frequency spacing in order to achieve a better interpolation. A FFTW header is used to compute the Fourier transform of the time series data. A Savitzky–Golay filter is applied on the unnormalized power which then can be used to remove the spectral shape. Each frequency spectrum has a bandwidth of 50 kHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mathematical Formulation used by MATLAB Code to Convert FTIR Interferograms to Calibrated Spectra

This report discusses the mathematical procedures used to convert raw interferograms from Fourier transform infrared (FTIR) sensors to calibrated spectra. The work discussed in this report was completed as part of the Helios project at Los Alamos National Laboratory. MATLAB code was developed to convert the raw interferograms to calibrated spectra. The report summarizes the developed MATLAB scripts and functions, along with a description of the mathematical methods used by the code. The first step in working with raw interferograms is to convert them to uncalibrated spectra by applying an apodization function to the raw data and then by performing a Fourier transform. The developed MATLAB code also addresses phase error correction by applying the Mertz method. This report provides documentation for the MATLAB scripts.

97 MATHEMATICS AND COMPUTING↗

Real-time ultrasound-tagging to track the 2D motion of the common carotid artery wall in vivo

Purpose: Tracking the motion of biological tissues represents an important issue in the field of medical ultrasound imaging. However, the longitudinal component of the motion (i.e., perpendicular to the beam axis) remains more challenging to extract due to the rather coarse resolution cell of ultrasound scanners along this direction. The aim of this study is to introduce a real-time beamforming strategy dedicated to acquire tagged images featuring a distinct pattern in the objective to ease the tracking. Methods: Under the conditions of the Fraunhofer approximation, a specific apodization function was applied to the received raw channel data, in real-time during image acquisition, in order to introduce a periodic oscillations pattern along the longitudinal direction of the radio frequency signal. Analytic signals were then extracted from the tagged images, and subpixel motion tracking of the intima–media complex was subsequently performed offline, by means of a previously introduced bidimensional analytic phase-based estimator. Results: The authors’ framework was applied in vivo on the common carotid artery from 20 young healthy volunteers and 6 elderly patients with high atherosclerosis risk. Cine-loops of tagged images were acquired during three cardiac cycles. Evaluated against reference trajectories manually generated by three experienced analysts, the mean absolute tracking error was 98 ± 84 μm and 55 ± 44 μm in the longitudinal and axial directions, respectively. These errors corresponded to 28% ± 23% and 13% ± 9% of the longitudinal and axial amplitude of the assessed motion, respectively. Conclusions: The proposed framework enables tagged ultrasound images of in vivo tissues to be acquired in real-time. Such unconventional beamforming strategy contributes to improve tracking accuracy and could potentially benefit to the interpretation and diagnosis of biomedical images.

60 APPLIED LIFE SCIENCES↗

Absorber for terahertz radiation management

A method and apparatus for minimizing the degradation of power in a free electron laser (FEL) generating terahertz (THz) radiation. The method includes inserting an absorber ring in the FEL beam path for absorbing any irregular THz radiation and thus minimizes the degradation of downstream optics and the resulting degradation of the FEL output power. The absorber ring includes an upstream side, a downstream side, and a plurality of wedges spaced radially around the absorber ring. The wedges form a scallop-like feature on the innermost edges of the absorber ring that acts as an apodizer, stopping diffractive focusing of the THz radiation that is not intercepted by the absorber. Spacing between the scallop-like features and the shape of the features approximates the Bartlett apodization function. The absorber ring provides a smooth intensity distribution, rather than one that is peaked on-center, thereby eliminating minor distortion downstream of the absorber.

43 PARTICLE ACCELERATORS↗

Highly uniform parallel microfabrication using a large numerical aperture system

In this letter, we report an improved algorithm to produce accurate phase patterns for generating highly uniform diffraction-limited multifocal arrays in a large numerical aperture objective system. It is shown that based on the original diffraction integral, the uniformity of the diffraction-limited focal arrays can be improved from ∼75% to >97%, owing to the critical consideration of the aperture function and apodization effect associated with a large numerical aperture objective. The experimental results, e.g., 3 × 3 arrays of square and triangle, seven microlens arrays with high uniformity, further verify the advantage of the improved algorithm. This algorithm enables the laser parallel processing technology to realize uniform microstructures and functional devices in the microfabrication system with a large numerical aperture objective.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Programmable Beam Shaping System for Tailoring the Profile of High Fluence Laser Beams

Customized spatial light modulators have been designed and fabricated for use as precision beam shaping devices in fusion class laser systems. By inserting this device in a low-fluence relay plane upstream of the amplifier chain, 'blocker' obscurations can be programmed into the beam profile to shadow small isolated flaws on downstream optical components that might otherwise limit the system operating energy. In this two stage system, 1920 x 1080 bitmap images are first imprinted on incoherent, 470 nm address beams via pixilated liquid crystal on silicon (LCoS) modulators. To realize defined masking functions with smooth apodized shapes and no pixelization artifacts, address beam images are projected onto custom fabricated optically-addressable light valves. Each valve consists of a large, single pixel liquid cell in series with a photoconductive Bismuth silicon Oxide (BSO) crystal. The BSO crystal enables bright and dark regions of the address image to locally control the voltage supplied to the liquid crystal layer which in turn modulates the amplitude of the coherent beams at 1053 nm. Valves as large as 24 mm x 36 mm have been fabricated with low wavefront distortion (<0.5 waves) and antireflection coatings for high transmission (>90%) and etalon suppression to avoid spectral and temporal ripple. This device in combination with a flaw inspection system and optic registration strategy represents a new approach for extending the operational lifetime of high fluence laser optics.

42 ENGINEERING↗

Secreted glycoprotein BmApoD1 plays a critical role in anti-oxidation and anti-apoptosis in Bombyx mori

Highlights: • Three apolipoprotein D homologs were identified from the genome of lepidopteran insect. • N-linked glycans were essential to the secretion of BmApoD1. • BmApoD1 transcription was up-regulated after oxidant or starvation treatment in larvae. • BmApoD1 can protect cells from oxidative stress and reduce actinomycin D-induced cell apoptosis. Recent studies highlighted that apolipoprotein D (ApoD) and its homologs exert neuroprotective and antioxidant functions in mammals and Drosophila. Unlike mammals and Drosophila, lepidopteran insects possess three distinct ApoD homologs. However, few information on their functions in lepidopteran insects are available. In this study, we investigated the protective potential of a novel ApoD homolog, BmApoD1, in Bombyx mori. Quantitative PCR analyses demonstrated that BmApoD1 is extensively expressed at low levels during the larval stage but abundantly expressed in the testis during the pupal and adult stages. Tryptophan fluorescence titration demonstrated that recombinant BmApoD1 protein can bind retinoic acid and ergosterol. In addition, we provided evidence that N-linked glycans of BmApoD1 are essential to BmApoD1 secretion, and three residues, namely, Asp69, Asp104, and Asp196, are the glycosylation sites of BmApoD1. Furthermore, we showed that BmApoD1 is significantly up-regulated in the larvae after oxidant or starvation treatment. The recombinant BmApoD1 protein can protect cells from oxidative stress induced by H{sub 2}O{sub 2} and reduce actinomycin D-induced cell apoptosis. These observations, together with the transcriptional up-regulation of BmApoD1 in several tissues upon oxidative insult, identify BmApoD1 as a potent antioxidant. Our results demonstrate that BmApoD1 is critical for metabolic adaptation of B. mori to environmental challenges.

60 APPLIED LIFE SCIENCES↗

Improving the reconstruction quality with extension and apodization of the digital hologram

To suppress the aperture diffraction and spectral leakage effects in the reconstruction process of the digital hologram and to maintain the original information recorded in the hologram, a novel reconstruction method based on extension and apodization of the digital hologram is presented, by which the original hologram can be extended by filling the average intensity values of the boundary, and the extended hologram is apodized by use of the constructed window function. As a sample, the digital hologram of the static particle field is recorded and numerically extended and then apodized with the appointed window. Finally, an unabridged and clear digital holographic image is reconstructed from the extended and apodized hologram. The experimental results confirm that this method cannot only eliminate the black-and-white diffraction fringes in the reconstructed image, but also attain the unabridged image with high quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transconvolution and the virtual positron emission tomograph-A new method for cross calibration in quantitative PET/CT imaging

Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating {sup 68}Ge/{sup 68}Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pupil Masks for Spectrophotometry of Transiting Exoplanets

Spectrophotometric stability, which is crucial in the spectral characterization of transiting exoplanets, is affected by photometric variations arising from field-stop loss in space telescopes with pointing jitter or primary mirror deformation. This paper focuses on a new method for removing slit-loss or field-stop-loss photometric variation through the use of a pupil mask. Two types of pupil function are introduced: the first uses conventional (e.g., Gaussian or hyper-Gaussian) apodizing patterns; whereas the second, which we call a block-shaped mask, employs a new type of pupil mask designed for high photometric stability. A methodology for the optimization of a pupil mask for transit observations is also developed. The block-shaped mask can achieve a photometric stability of 10{sup −5} for a nearly arbitrary field-stop radius when the pointing jitter is smaller than approximately 0.7λ/D and a photometric stability of 10{sup −6} at a pointing jitter smaller than approximately 0.5λ/D. The impact of optical aberrations and mask imperfections upon mask performance is also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Partial confinement photonic crystal waveguides

One-dimensional photonic crystal waveguides with an incomplete photonic band gap are modeled and proposed for an integration application that exploits their property of partial angular confinement. Planar apodized photonic crystal structures are deposited by plasma enhanced chemical vapor deposition and characterized by reflectivity as a function of angle and polarization, validating a partial confinement design for light at 850 nm wavelength. Partial confinement identifies an approach for tailoring waveguide properties by the exploitation of conformal film deposition over a substrate with angularly dependent topology. An application for an optoelectronic transceiver is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Fiber Optic Gas Sensing for Harsh Environment

This report summarizes work to develop a novel distributed fiber-optic micro-sensor that is capable of detecting common fossil fuel gases in harsh environments. During the 32-month research and development (R&D) program, GE Global Research successfully synthesized sensing materials using two techniques: sol-gel based fiber surface coating and magnetron sputtering based fiber micro-sensor integration. Palladium nanocrystalline embedded silica matrix material (nc-Pd/Silica), nanocrystalline palladium oxides (nc-PdO{sub x}) and palladium alloy (nc-PdAuN{sub 1}), and nanocrystalline tungsten (nc-WO{sub x}) sensing materials were identified to have high sensitivity and selectivity to hydrogen; while the palladium doped and un-doped nanocrystalline tin oxide (nc-PdSnO{sub 2} and nc-SnO{sub 2}) materials were verified to have high sensitivity and selectivity to carbon monoxide. The fiber micro-sensor comprises an apodized long-period grating in a single-mode fiber, and the fiber grating cladding surface was functionalized by above sensing materials with a typical thickness ranging from a few tens of nanometers to a few hundred nanometers. GE found that the morphologies of such sensing nanomaterials are either nanoparticle film or nanoporous film with a typical size distribution from 5-10 nanometers. nc-PdO{sub x} and alloy sensing materials were found to be highly sensitive to hydrogen gas within the temperature range from ambient to 150 C, while nc-Pd/Silica and nc-WO{sub x} sensing materials were found to be suitable to be operated from 150 C to 500 C for hydrogen gas detection. The palladium doped and un-doped nc-SnO{sub 2} materials also demonstrated sensitivity to carbon monoxide gas at approximately 500 C. The prototyped fiber gas sensing system developed in this R&D program is based on wavelength-division-multiplexing technology in which each fiber sensor is identified according to its transmission spectra features within the guiding mode and cladding modes. The interaction between the sensing material and fossil fuel gas results in a refractive index change and optical absorption in the sensing layer. This induces mode coupling strength and boundary conditions changes and thereby shifts the central wavelengths of the guiding mode and cladding modes propagation. GE's experiments demonstrated that such an interaction between the fossil fuel gas and sensing material not only shifts the central wavelengths of the guide mode and cladding modes propagation, but also alters their power loss characteristics. The integrated fiber gas sensing system includes multiple fiber gas sensors, fiber Bragg grating-based temperature sensors, fiber optical interrogator, and signal processing software.

08 HYDROGEN↗

Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics

Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal planes, and the effect of prior knowledge on detectability. Custom-built phantoms ({approx}15 cm diameter cylinders) containing soft-tissue-simulating spheres of variable contrast and diameter were imaged on an experimental CBCT bench. The proportion of correct responses (P{sub corr}) in 2AFC tests was analyzed as a figure of merit, ideally equal to the area under the receiver operating characteristic curve. P{sub corr} was evaluated as a function of the sphere diameter (1.6-12.7 mm), contrast (20-165 HU), dose (1-7 mGy), plane of visualization (axial/sagittal), apodization filter (Hanning and Ram-Lak), and prior knowledge provided to the observer [ranging from stimulus known exactly (SKE) to stimulus unknown (SUK)]. Detectability limits were characterized in terms of the dose required to achieve a given level of P{sub corr} (e.g., 70%). For example, a 20 HU stimulus of diameter down to {approx}6 mm was detected with P{sub corr} 70% at dose {>=}2 mGy. Detectability tended to be greater in axial than in sagittal planes, an effect amplified by sharper apodization filters in a manner consistent with 3D NPS asymmetry. Prior knowledge had a marked influence on detectability - e.g., P{sub corr} for a {approx}6 mm(20 HU) sphere was {approx}55%-65% under SUK conditions, compared to {approx}70%-85% for SKE conditions. Human observer tests suggest practical implications for implementation of CBCT: (i) Detectability limits help to define minimum-dose imaging techniques for specific imaging tasks; (ii) detectability of a given structure can vary between axial and sagittal/coronal planes, owing to the spatial-frequency content of the 3D NPS in relation to the imaging task; and (iii) performance under SKE conditions (e.g., image guidance tasks in which lesion characteristics are known) is maintained at a lower dose than in SUK conditions (e.g., diagnostic tasks in which lesion characteristics are unknown)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects

Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarized CMB power spectrum estimation using the pure pseudo-cross-spectrum approach

We extend the pure pseudo-power-spectrum formalism proposed recently in the context of the cosmic microwave background polarized power spectra estimation by Smith (2006) to incorporate cross-spectra computed for multiple maps of the same sky area. We present an implementation of such a technique, paying particular attention to a calculation of the relevant window functions and mixing (mode-coupling) matrices. We discuss the relevance and treatment of the residual E/B leakage for a number of considered sky apodizations as well as compromises and assumptions involved in an optimization of the resulting power spectrum uncertainty. In particular, we investigate the importance of a pixelization scheme, patch geometry, and sky signal priors used in apodization optimization procedures. In addition, we also present results derived for more realistic sky scans as motivated by the proposed balloon-borne experiment EBEX. We conclude that the presented formalism, thanks to its speed and efficiency, can provide an interesting alternative to the CMB polarized power spectra estimators based on the optimal methods at least on angular scales smaller than {approx}10 deg. In this regime, we find that it is capable of suppressing the total variance of the estimated B-mode spectrum to within a factor of {approx}2 of the variance due to only the sampling and noise uncertainty of the B modes alone, as derived from the Fisher matrix approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗