Search NASA⌕ Search

SEARCH · Search NASA

Results for “Argon sorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Laboratory simulation of meteoritic noble gases. III - Sorption of neon, argon, krypton, and xenon on carbon - Elemental fractionation

The sorption of Ne, Ar, Kr, and Xe was studied in carbon black, acridine carbon, and diamond in an attempt to understand the origin of trapped noble gases in meteorites. The results support a model in which gases are physically adsorbed on interior surfaces formed by a pore labyrinth within amorphous carbons. The data show that: (1) the adsorption/desorption times are controlled by choke points that restrict the movement of noble gas atoms within the pore labyrinth, and (2) the physical adsorption controls the temperature behavior and elemental fractionation patterns.

Wacker, John F.↗

Interaction of gases with ablative composites. I - Ar, CO2, and N2

The sorption of argon, carbon dioxide, and nitrogen on two heat shield composites (SLA-561 and SLA-561V) and on the SLA components was measured over the pressure range of 0.001 to 760 torr and in the temperature range of 30 to 50 C. The sorption of the gases by both the composites and the components varied directly with pressure. The sorption of CO2 by the phenolic spheres and the silicone elastomer and of Ar by the silicone elastomer varied inversely with temperature. The mechanism involved in the gas sorption was primarily absorption.

King, C. A.↗

Characterization of shale using Helium and Argon at high pressures

In order to estimate the shale gas in place and the eventual recovery during shale gas operations, one of the key requirements is to accurately characterize the shale’s petrophysical and transport properties such as porosity, permeability, diffusivity, and storage capacity. Despite the many efforts reported in the technical literature aiming to provide an improved understanding of the complex pore structures and the associated fluid flow in gas shales, complete characterization of organic-rich shale samples still poses a big challenge. Here, we have characterized mass transfer and sorption in shale at different length scales using Helium (He) and Argon (Ar) as probe gases. Thermogravimetric analysis (TGA) with a shale cube of ~1 cm 3 in size and gas expansion experiments with a full-diameter core (3.5” in diameter) were used to measure sorption kinetics/isotherms and mass transfer, respectively. Both samples are from the same depth/location in the Marcellus shale formation. The TGA steady-state technique was initially used to generate excess sorption isotherms for Ar, while dynamic TGA experiments were used to study its sorption kinetics. The TGA experiments demonstrate that Ar, which has a similar sorption potential as Methane, but is generally assumed to be inert, adsorbs onto the surfaces of the mesoporous and microporous regions of the shale samples according to a Langmuir-type behavior. Helium expansion experiments, on the full-diameter core, were used to measure the overall porosity, on the basis that He is a non-sorbing and inert gas as compared to Ar. The He expansion experiments, furthermore, allow us to delineate the mass transfer of gas across the inherent hierarchy of pore sizes, including macropores (macro- and microcracks), mesopores and micropores. Similar expansion experiments were also performed with Ar to study the combined impact of mass transfer and sorption. A triple-porosity model (TPM) was utilized to interpret the He expansion experiments with the shale core and to extract (estimate) relevant transport parameters. We report and compare here the diffusivities and permeabilities of the whole core for both He and Ar, as calculated from the modeling and fitting of the experimental data. On the premise that the shale cube is representative of the matrix region of the core, the Ar sorption kinetics from the cube experiments were subsequently combined with the transport parameters extracted from the He experiments to predict the behavior of the Ar expansion test with the full-diameter core. An excellent agreement is observed between the model predictions and the experimental data. The experimental observations and their interpretation indicate that one must be cautious when using Ar to estimate the true porosity and permeability of shales. In addition, we demonstrate that He and Ar probe gases, when used in tandem, can be employed effectively as a tool to characterize shales in terms of mass transfer and sorption dynamics across scales.

04 OIL SHALES AND TAR SANDS↗

Synodic and Semiannual Oscillations of Argon-40 in the Lunar Exosphere

The neutral mass spectrometer on the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft collected a trove of exospheric data, including a set of high-quality measurements of radiogenic Ar-40 over a period of 142 days. Data synthesis studies, using well-established exosphere simulation tools, show that the LADEE argon data are consistent with an exosphere-regolith interaction that is dominated by adsorption and that the desorption process generates the Armand distribution of exit velocities. The synthesis work has uncovered an apparent semiannual oscillation of argon that is consistent with temporal sequestration in the seasonal cold traps created at the poles by the obliquity of the Moon. In addition, the LADEE data provide new insight into the pristine nature of lunar regolith, its spatially varying sorption properties, and the influence of sorption processes on the synodic oscillation of the argon exosphere.

argon-40↗

Buffer Gas Acquisition and Storage

The acquisition and storage of buffer gases (primarily argon and nitrogen) from the Mars atmosphere provides a valuable resource for blanketing and pressurizing fuel tanks and as a buffer gas for breathing air for manned missions. During the acquisition of carbon dioxide (CO2), whether by sorption bed or cryo-freezer, the accompanying buffer gases build up in the carbon dioxide acquisition system, reduce the flow of CO2 to the bed, and lower system efficiency. It is this build up of buffer gases that provide a convenient source, which must be removed, for efficient capture Of CO2 Removal of this buffer gas barrier greatly improves the charging rate of the CO2 acquisition bed and, thereby, maintains the fuel production rates required for a successful mission. Consequently, the acquisition, purification, and storage of these buffer gases are important goals of ISRU plans. Purity of the buffer gases is a concern e.g., if the CO, freezer operates at 140 K, the composition of the inert gas would be approximately 21 percent CO2, 50 percent nitrogen, and 29 percent argon. Although there are several approaches that could be used, this effort focused on a hollow-fiber membrane (HFM) separation method. This study measured the permeation rates of CO2, nitrogen (ND, and argon (Ar) through a multiple-membrane system and the individual membranes from room temperature to 193K and 10 kpa to 300 kPa. Concentrations were measured with a gas chromatograph that used a thermoconductivity (TCD) detector with helium (He) as the carrier gas. The general trend as the temperature was lowered was for the membranes to become more selective, In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar.

Parrish, Clyde F.↗

Structure–Transport Relationships of Water–Organic Solvent Co-transport in Carbon Molecular Sieve (CMS) Membranes

We explore the effects of the carbon molecular sieve (CMS) microstructure on the separation performance and transport mechanism of water–organic mixtures. Specifically, we utilize PIM-1 dense films and integrally skinned asymmetric hollow fiber membranes as polymer precursors for the CMS materials. The PIM-1 membranes were pyrolyzed under several different pyrolysis atmospheres (argon, carbon dioxide, and diluted hydrogen gas) and at multiple pyrolysis temperatures. Detailed gas physisorption measurements reveal that membranes pyrolyzed under 4% H 2 and CO 2 had broadened ultramicropore distributions (pore diameter <7 Å) compared to Ar pyrolysis, and pyrolysis under CO 2 increased ultramicropore volume and broadened micropore distributions at increased pyrolysis temperatures. Gravimetric water and p-xylene sorption and diffusion measurements reveal that the PIM-1-derived CMS materials are more hydrophilic than other CMS materials that have been previously studied, which leads to sorption-diffusion estimations showing water-selective permeation. Water permeation in the vapor phase, pervaporation, and liquid-phase hydraulic permeation reveal that the isobaric permeation modes (vapor permeation and pervaporation) are reasonably well predicted by the sorption-diffusion model, whereas the hydraulic permeation mode is significantly underpredicted (>250×). Conversely, the permeation of p-xylene is well predicted by the sorption-diffusion model in all cases. The collection of pore size analysis, vapor sorption and diffusion, and permeation in different modalities creates a picture of a combined transport mechanism in which water–under high transmembrane pressures–permeates via a Poiseuille-style mechanism, whereas p-xylene solutes in the mixture permeate via sorption-diffusion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water Sorption/Desorption Characteristics of Eutectic LiCl-KCl Salt-Occluded Zeolites

Molten salt consisting primarily of eutectic LiCl-KCl is currently being used in electrorefiners in the Fuel Conditioning Facility at Idaho National Laboratory. Options are currently being evaluated for storing this salt outside of the argon atmosphere hot cell. The hygroscopic nature of eutectic LiCl-KCl makes is susceptible to deliquescence in air followed by extreme corrosion of metallic cannisters. In this study, the effect of occluding the salt into a zeolite on water sorption/desorption was tested. Two zeolites were investigated: Na-Y and zeolite 4A. Na-Y was ineffective at occluding a high percentage of the salt at either 10 or 20wt% loading. Zeolite-4A was effective at occluding the salt with high efficiency at both loading levels. Weight gain in salt occluded zeolite-4A (SOZ) from water sorption at 20% relative humidity and 40°C was 17wt% for 10% SOZ and 10wt% for 20% SOZ. In both cases, neither deliquescence nor corrosion occurred over a period of 31 days. After hydration, most of the water could be driven off by heating the hydrated salt occluded zeolite to 530°C. However, some HCl forms during dehydration due to salt hydrolysis. Over a wide range of temperatures (320–700°C) and ramp rates (5, 10, and 20°C min -1 ), HCl formation was no more than 0.6% of the Cl - in the original salt.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring Gas Transport and Sorption in Large Intact Geologic Specimens via the Piezometric Method

Uptake of noble gases into heterogeneous geologic core samples was measured using a piezometric methodology. In addition to measuring accessible porosity—as with gas pycnometry—by monitoring the rate of pressure decay, this method can also be used to estimate the gas effective diffusivity in the sample. In contrast to previous applications of this method, where milligram quantities of fractured grains are characterized, here approximately kilogram core samples were left intact when tested. In doing so, a more representative sample of the heterogeneous field geology is provided. Additionally, alteration of the pore structure and connectivity during sample preparation is avoided. Furthermore, to scale the piezometric method from milligrams to kilograms, the system was designed to operate at medium vacuum (1 to 100 Pa) to restrict transport in pores less than approximately 60 µm to large Knudsen numbers. To test the system performance, two samples of interest were selected: a rhyolitic welded tuff from Blue Canyon Dome at the Energetic Materials Research and Testing Center and a zeolitized non-welded rhyolitic tuff from the Nevada National Security Site. Three noble gases were utilized in this test series; Argon and xenon as they are of direct interest to nuclear monitoring efforts and helium as it is a weakly adsorbing reference standard. Additionally, mercury intrusion porosimetry measurements were made on subsamples of the core to compare the observed porosity by the two methods and to discuss gas transport rates in the context of the measured pore distribution.

58 GEOSCIENCES↗