Search NASASearch

SEARCH · Search NASA

Results for “Artifact reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement

A study of the temporal and spectral characteristics of gamma ray bursts

Gamma-ray burst data obtained from the ISEE-3 Gamma Ray Burst Spectrometer and the Solar Maximum Mission's Hard X-ray Burst Spectrometer (HXRBS) were analyzed to yield information on burst temporal and spectral characteristics. A Monte Carlo approach was used to simulate the HXRBS response to candidate spectral models. At energies above about 100 keV, the spectra are well fit by exponential forms. At lower energies, 30 keV to 60 keV, depressions below the model continua are apparent in some bursts. The depressions are not instrumental or data-reduction artifacts. The event selection criterion of the ISEE-3 experiment is based on the time to accumulate a present number of photons rather than the photon count per unit time and is consequently independent of event duration for a given burst intensity, unlike most conventional systems. As a result, a significantly greater percentage of fast, narrow events have been detected. The ratio of count rates from two ISEE-3 detectors indicates that bursts with durations or approx. one second have much softer spectra than longer bursts.

Norris, J.

Reduction of display artifacts by random sampling

The application of random-sampling techniques to remove visible artifacts (such as flicker, moire patterns, and paradoxical motion) introduced in TV-type displays by discrete sequential scanning is discussed and demonstrated. Sequential-scanning artifacts are described; the window of visibility defined in spatiotemporal frequency space by Watson and Ahumada (1982 and 1983) and Watson et al. (1983) is explained; the basic principles of random sampling are reviewed and illustrated by the case of the human retina; and it is proposed that the sampling artifacts can be replaced by random noise, which can then be shifted to frequency-space regions outside the window of visibility. Vertical sequential, single-random-sequence, and continuously renewed random-sequence plotting displays generating 128 points at update rates up to 130 Hz are applied to images of stationary and moving lines, and best results are obtained with the single random sequence for the stationary lines and with the renewed random sequence for the moving lines.

Ahumada, A. J., Jr.

Use of a Fourier transform spectrometer on a balloon-borne telescope and at the multiple mirror telescope (MMT)

The design and use of an infrared Fourier transform spectrometer which has been used for observations of laboratory, stratospheric, and astronomical spectra are described. The spectrometer has a spectral resolution of 0.032/cm and has operated in the mid-infrared (12 to 13 microns) as well as the far-infrared (40 to 140 microns), using both bolometer and photoconductor cryogenic detectors. The spectrometer is optically sized to accept an f/9 beam from the multi-mirror telescope (MMT). The optical and electronic design are discussed, including remote operation of the spectrometer on a balloon-borne 102-cm telescope. The performance of the laser-controlled, screw-driven moving cat's-eye mirror is discussed. Segments of typical far-infrared balloon flight spectra, lab spectra, and mid-infrared MMT spectra are presented. Data reduction, interferogram processing, artifact removal, wavelength calibration, and intensity calibration methods are discussed. Future use of the spectrometer is outlined.

Traub, W. A.

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts

Are the high-latitude torsional oscillations of the sun real

A numerical test is made to determine if the high-latitude torsional wave is generated from the low-latitude torsional pattern as a result of reduction procedures. The results indicate that the high-latitude motions are not an artifact of the analysis, but are true solar features. It is also demonstrated that the one-wave-per-hemisphere torsional oscillation does not result from the reduction procedure. These results place the observations in conflict with the predictions of alpha-omega models of the solar cycle.

Labonte, B. J.

Neutron matter from local chiral effective field theory interactions at large cutoffs

Neutron matter is an important many-body system that provides valuable constraints for the equation of state (EOS) of neutron stars. Neutron-matter calculations employing chiral effective field theory (EFT) interactions have been extensively used for this purpose. Among the various many-body methods, quantum Monte Carlo (QMC) methods stand out due to their nonperturbative nature and the achievable precision. However, QMC methods require local interactions as input, which leads to the appearance of stronger regulator artifacts compared to nonlocal interactions. To circumvent this, we employ large-cutoff interactions derived within chiral EFT (400 MeV ≤ Λ 𝑐 ≤ 700MeV) for studies of pure neutron matter. These interactions have been adjusted to nucleon-nucleon scattering phase shifts, the triton binding energy, as well as the triton 𝛽-decay half-life. We find that regulator artifacts significantly decrease with increasing cutoff, leading to a significant reduction of uncertainties in the neutron-matter EOS. We discuss implications for the symmetry energy and demonstrate how our new calculations lead to a reduction in the theoretical uncertainty of predicted neutron-star radii by up to 30% for low-mass stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.

The reduction of wide field/planetary camera images

An overview of the procedures required for reduction of Hubble Space Telescope Wide Field/Planetary Camera images is presented, based on WFPC performance as observed during ground tests. Camera artifacts that must be removed prior to analysis of WFPC images are characterized. WFPC flat-field and dark-current images are also presented. Special emphasis is given to the design of WFPC imaging programs that minimize the effects of camera artifacts on image analysis.

Lauer, Tod R.

Quantitative determination of microbial activity and community nutritional status in estuarine sediments: evidence for a disturbance artifact

In estuarine sediments with a high degree of vertical heterogeneity in reduced substrate and terminal electron acceptor concentrations, the method of exposure of the microbiota to labeled substrates can introduce a "disturbance artifact" into measures of metabolic activity. The detection of this artifact is based on quantitative measurement of the relative rates of incorporation of [14C]acetate into phospholipid fatty acids (PLFA) and endogenous storage lipid, poly-beta-hydroxyalkanoate (PHA). Previous studies have shown that PLFA synthesis measures cellular growth and that PHA synthesis measures carbon accumulation (unbalanced growth). The "disturbance artifact" of exposure to [14C]acetate was demonstrated by comparing injection of a core with the usual or pore-water replacement or slurry techniques. Only injection of labeled substrate allowed detection of preassay disturbance of the sediment with a garden rake. The raking increased PLFA synthesis with little effect to differences in concentration or distribution of [14C]acetate in the 10-min incubation. Bioturbation induced by sand dollar feeding in estuarine sediment could be detected in an increased PLFA/PHA ratio which was due to decreased PHA synthesis if the addition of labeled substrate was by the injection technique. Addition of labeled precursors to sediment by slurry or pore-water replacement induces greater disturbance artifacts than injection techniques.

Phospholipids/analysis/biosynthesis

Transplatformer: translating toxicogenomic profiles between generations of platforms

Background Transcriptomic profiling technologies have advanced the analysis of biological and toxicological responses. However, substantial differences in probe design, dynamic range, gene coverage, and preprocessing pipelines across platforms introduce artifacts that limit cross-study integration and hinder the reuse of historical datasets. We aim to develop computational methods for accurate cross-platform translation to maximize the value of legacy resources. Results We present TransPlatformer a deep learning framework for translating gene expression profiles across heterogeneous toxicogenomics platforms. TransPlatformer employs a novel attention-based architecture to map high-dimensional fold-change vectors from legacy microarray technologies to current platforms. Models are trained and evaluated using DrugMatrix, spanning three technological generations. We investigate mixed-tissue, single-tissue, and cross-tissue training paradigms and benchmark performance against multilayer perceptron and matrix-completion baselines. In mixed-tissue training, TransPlatformer achieves a greater than 50% reduction in mean absolute error (0.043 vs. 0.09) and nearly doubles Pearson correlation ( ≈ 0.71 vs. 0.37) relative to baseline methods. Importantly, TransPlatformer preserves rare but biologically meaningful over- and under-expressed signals, with mean absolute error below 0.22. Single-tissue models yield further improvements for well-represented organs, such as a 10% reduction in liver mean absolute error, while underscoring the need for data augmentation strategies in low-sample tissues.ra Conclusions TransPlatformer provides an effective and scalable computational solution for cross-platform transcriptomic translation. By enabling biologically faithful harmonization of gene expression data, the proposed approach facilitates the reuse of legacy toxicogenomics datasets, enhances downstream biomarker discovery, and supports more reproducible predictive modeling in toxicology.

59 BASIC BIOLOGICAL SCIENCES

Distributed Stochastic Optimization of a Neural Representation Network for Time-Space Tomography Reconstruction

4D time-space reconstruction of dynamic events or deforming objects using X-ray computed tomography (CT) is an important inverse problem in non-destructive evaluation. Conventional back-projection based reconstruction methods assume that the object remains static for the duration of several tens or hundreds of X-ray projection measurement images (reconstruction of consecutive limited-angle CT scans). However, this is an unrealistic assumption for many in-situ experiments that causes spurious artifacts and inaccurate morphological reconstructions of the object. To solve this problem, we propose to perform a 4D time-space reconstruction using a distributed implicit neural representation (DINR) network that is trained using a novel distributed stochastic training algorithm. Our DINR network learns to reconstruct the object at its output by iterative optimization of its network parameters such that the measured projection images best match the output of the CT forward measurement model. Here, we use a forward measurement model that is a function of the DINR outputs at a sparsely sampled set of continuous valued 4D object coordinates. Unlike previous neural representation architectures that forward and back propagate through dense voxel grids that sample the object's entire time-space coordinates, we only propagate through the DINR at a small subset of object coordinates in each iteration resulting in an order-of-magnitude reduction in memory and compute for training. DINR leverages distributed computation across several compute nodes and GPUs to produce high-fidelity 4D time-space reconstructions. We use both simulated parallel-beam and experimental cone-beam X-ray CT datasets to demonstrate the superior performance of our approach.

36 MATERIALS SCIENCE