Search NASA⌕ Search

SEARCH · Search NASA

Results for “As-Run Thermal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

BSU-8242 As-Run Thermal Analysis

This report contains the Engineering Calculations and Analysis Report (ECAR)-5510 documenting the thermal as-run analysis of the 1 and 3 DPA capsules that comprised the BSU-8242 Nuclear Science User Facilities Experiment.

36 MATERIALS SCIENCE↗

As-Run Thermal Analysis for the CSM-10584 Experiment

The purpose of this document is to present the as-run specimen temperatures for the CSM-10584 experiment irradiated in position B-5 of the Advanced Test Reactor (ATR) for Cycles 164A and 164B.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ECAR-3386 AS-RUN THERMAL ANALYSIS OF THE AGC-3 EXPERIMENT

The third Advanced Graphite Creep (AGC-3) experiment was designed to irradiate various types of graphite specimens at a temperature of 900°C. The specimens were irradiated in an instrumented leadout capsule experiment in the east flux trap of the ATR during cycles 152B, 154B, 155A, and 155B. Temperature was monitored using twelve thermocouples located at various elevations in the reactor core, and a helium-argon gas mixture was used for gas gap temperature control of the specimens. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and helium-argon gas flows, and as-run calculations of heating rates and displacement per atom (DPA) in graphite. The accuracy of the model is assessed by comparing measured and calculated thermocouple temperatures. Uncertainty in gas gaps may preclude an accurate temperature calculation. In these cases, adjustments are made to the thermal model in order to reconcile the measured and calculated thermocouple temperature and to ensure the accuracy of the calculated specimen temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ECAR-2322 As-Run Thermal Analysis Of The AGC-2 Experiment

The second Advanced Graphite Creep (AGC-2) experiment was designed to irradiate various types of graphite specimens at a temperature of 600°C. The specimens were irradiated in an instrumented leadout capsule experiment in the south flux trap of the ATR during cycles 149A, 1498, 1508, 151A, and 1518. Temperature was monitored using twelve thermocouples located at various elevations in the reactor core, and a helium-argon gas mixture was used for gas gap temperature control of the specimens. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and helium-argon gas flows, and as-run calculations of heating rates and displacement per atom (DPA) in graphite. The accuracy of the model is assessed by comparing measured and calculated thermocouple temperatures. Uncertainty in gas gaps may preclude an accurate temperature calculation. In these cases, adjustments are made to the thermal model in order to reconcile the measured and calculated thermocouple temperature and to ensure the accuracy of the calculated specimen temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

As-Run Thermal Analysis for the AGC-4 Experiment Irradiated in the ATR

The Advanced Graphite Capsule (AGC) irradiation experiment will provide irradiation creep rate data for the new graphite proposed for the Next Generation Nuclear Plant (NGNP) program. The fourth experiment in the series (AGC-4) was designed to irradiate various types of graphite specimens at a temperature of 900 ºC and targeted displacements per atom (DPA) of 6. This experiment has been irradiated in the east flux trap of the Advanced Test Reactor (ATR) during the cycles of 157D, 158A, 162A, 162B, 164A, 164B, 166A, and 166B. Temperatures were monitored using twelve thermocouples (TC) located at various elevations in the reactor core, and variable helium-argon gas mixtures were used for gas gap temperature control of the specimens. The purpose of this Engineering Calculation and Analysis Report (ECAR) is to calculate the specimen temperature after the model is calibrated by the measured TC data with the as-run heating rates of the components, DPA of the graphite, and the gas mixture compositions during the experiment. As-run specimen mean temperature and the tolerance will be obtained.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

As-run thermal hydraulics analysis of the EPRI-1 Experiment

The EPRI-1 experiment was designed to irradiate various types of reactor pressure vessel steels at a temperature of 288°C (PLN-3934). The specimens were irradiated in an instrumented test train inside a pressurized water loop in the center lobe of the ATR during cycle 157C. Temperature was monitored using thermocouples placed at the top of the test train. Additional temperature indications were obtained by post-irradiation examination of melt wires placed within the test train and spanning the temperature range 239°C to 327°C. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and as-run calculations of heating rates of the test train. The accuracy of the model is assessed by comparing the measured and calculated in-pile tube inlet to outlet temperature difference, comparing the measured and calculated thermocouple temperatures, and comparing the calculated specimen temperature to the temperature range indicated by the melt wires.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

As-run thermal-hydraulics analysis of the EPRI-2 experiment

The EPRI-2 experiment was designed to irradiate various types of reactor pressure vessel steels at a temperature of 288°C (PLN-3934). The specimens were irradiated in a non-instrumented test train inside a pressurized water loop in the center lobe of the ATR during PALM cycle 153B. Temperature was indicated by post-irradiation examination of melt wires placed within the test train. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and as-run calculations of heating rates of the test train. The experiment contains several melt wires spanning the temperature range 239°C to 327°C. The accuracy of the model is assessed by comparing the measured and calculated in-pile tube inlet to outlet temperature difference, and comparing the calculated specimen temperature to the temperature range indicated by examination of the melt wires.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

As-run thermal-hydraulic analysis of the EPRI-3 experiment

The EPRI-3 experiment was designed to irradiate various types of reactor internal component steels at a temperature of 288°C. The specimens were irradiated in an instrumented test train inside a pressurized water loop in the center lobe of the ATR during cycles 155B and 158B. Temperature was monitored using thermocouples placed at the top of the test train and melt wires placed within the test train. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and as-run calculations of heating rates of the test train. The experiment contains four thermocouples and several melt wires spanning the temperature range 239°C to 327°C. The accuracy of the model is assessed by comparing the measured and calculated in-pile tube inlet to outlet temperature difference, comparing the measured and calculated thermocouple temperatures, and comparing the calculated melt wire temperature to the temperature range indicated by examination of the melt wires.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

The daily as-run thermal analysis for the Advanced Gas Reactor (AGR)-5/6/7 experiment was documented in ECAR-5633 (Hawkes 2021). A finite element model was created for the entire test train, which consisted of five capsules. The fuel compacts, graphite holders, stainless-steel capsule walls, and all other major components were individually modeled, including all thermocouples (TCs). Daily heat rates for each compact and component in the model were input from daily as-run physics analyses. Daily gas compositions for each capsule were also input. The thermal conductivity of the compacts and graphite holders varied with fast neutron fluence. Gas mixture thermal conductivity was implemented using experimentally attained values from the literature. Fluence and temperature-dependent thermal conductivity was used for the graphite components and the fuel compacts. Radiation heat transfer was implemented. The model was tuned in an attempt to match the TC readings during the first cycle by adjusting the Neolube (graphite lubricant) thickness.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ECAR-1944 AGC-1 AS RUN THERMAL RESULTS

Purpose of this ECAR is to provide documentation of as-run analysis results for each specimen temperature in the AGC-1 test train at specific time points during the irradiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗