Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗

The Athena/X-IFU, from Detector Development to Scientific Feasibility Studies via Simulations

The investigation of the physical hot and energetic phenomena in the Universe will further improve our understanding of the assembly of the largest structures and massive halos of galaxies, and of the role of black holes in shaping the Universe as we see it. Spatially resolved X-ray high-resolution spectroscopy will be a crucial tool to achieve these scientific goals. The X-IFU instrument onboard the Athena observatory will provide us with these capabilities through the use of arrays of Transition edge microcalorimeters detectors. These superconducting devices will deliver the required exquisite spectral resolution needed to achieve the core science objectives, such as the characterization of turbulence and bulk motions in the hot gaseous atmospheres of groups and clusters of galaxies in order to unveil the process of large scale structures assembly. I will present the Transition Edge Sensors principle, the status of the instrumental development for the X-IFU instrument, and discuss their performance in view of the scientific objectives of the Athena mission. I will further present the case of a feasibility study and optimisation of the observing strategy for the characterization of the internal dynamics of the intra-cluster medium, through the use of mock simulations of observations with the X-IFU instrument.

Sophie Beaumont↗

Development of an End-to-end Demonstration Readout Chain for Athena/X-IFU

The X-ray Integral Field Unit(X-IFU) of the Athena observatory, scheduled for launch in the mid2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved with a 2kilo-pixel array of transition-edge sensor (TES) microcalorimeters. The complete detection chain is under development by a large international collaboration. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench uses a two-stage ADR cryostat from Entropy GmbH, a 1024-pixelarray, and will initially be operated using a warm electronics chain from NIST and NASA Goddard Space Flight Center. We describe the complete system being installed in the cryostat and the current results obtained with these electronics. We also review the status of the integration of the digital readout electronics (DRE)prototype into the demonstration chain and the plan for integrating and testing the complete X-IFU readout chain.

S Beaumont↗

Development of the Microcalorimeter Detector for Athena/X-IFU

The X-ray Integral Field Unit (X-IFU) will be a microcalorimeter instrument on ESA’s Athena X-ray observatory, set to launch around 2037. Athena recently underwent a reformulation exercise resulting in a simplified X-IFU architecture, with a new baseline configuration featuring fewer pixels and readout channels. Newly developed transition edge sensor pixels that are slower and have reduced magnetic field sensitivity have helped enable the new instrument design whilst maintaining flagship quality science. In this paper, we report on the status and plan for continued development of the X-IFU microcalorimeter array. We describe details of the current pixel architecture and performance specifications. We will present the design of the first full scale microcalorimeter arrays that have the necessary flight like electrical and mechanical interfaces for X-IFU. These arrays will undergo testing in a focal-plane assembly (FPA) Development Model (DM) in Europe later in 2024 and serve as a precursor to the X-IFU Engineering Model detector.

Stephen J Smith↗

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics↗

Thermal Impact of Cosmic Ray Interaction with an XRay Microcalorimeter Array

The X-ray Integral Field Unit (X-IFU) instrument on the Athena mission will be positioned at the Lagrangian point L2 and be subject to cosmic rays generated by astrophysics sources, primarily relativistic protons. Previous simulations have shown that particles of energy higher than 150 MeV will make it through the outer layers of the satellite. They will reach the detector wafer with a rate of 3 cts/sq. cm/s and a most probable energy deposited in the Si frame supporting the array at 150 keV. These events can affect the energy resolution of the detectors through the thermal fluctuations that they produce. This study assesses this potential problem and discusses two suggested design approaches to decrease the impact of cosmic ray in order to limit their effect to their allocation of 0.2 eV within the Athena/X-IFU energy-resolution budget. The first is the addition of a coating layer of high heat capacity material (e.g., Pd) and the second is the splitting of this coating into two thermal regions near the TES array to keep the heat away from the array. Implementing these two features is predicted to cause a decrease in the number of events above 1 μK by more than a factor 10 to ~ 1.5 cps when compared to an equivalent design without these features.

Antoine R. Miniussi↗

Modeling Magnetic Disk Wind State Transitions in Black Hole X-Ray Binaries

We analyze three prototypical black hole X-ray binaries, 4U 1630–472, GRO J1655–40, and H1743–322, in an effort to systematically understand the intrinsic state transition of the observed accretion disk winds between wind-on and wind-off states by utilizing state-of-the-art Chandra/HETGS archival data from multi-epoch observations. We apply our magnetically driven wind models in the context of magnetohydrodynamic(MHD)calculations to constrain(1)their global density slope(p),(2)their density (n17) at the foot point of the inner most launching radius, and(3)the abundances of heavier elements(AFe,S,Si). Incorporating the MHD winds into xstar photoionization calculations in a self-consistent manner, we create a library of synthetic absorption spectra given the observed X-ray continua. Our analysis clearly indicates a characteristic bimodal transition of multi-ion X-ray winds; i.e., the wind density gradient is found to steepen(fro mp∼1.2–1.4 to∼1.4–1.5)while its density normalization declines as the source transitions from the wind-onto the wind-off state. The model implies that the ionized wind remains physically present even in the wind-off state, despite its apparent absence in the observed spectra. Super solar abundances for heavier elements are also favored. Our global multi-ion wind models, taking into account soft X-ray ions as well as Fe K absorbers, show that the internal wind condition plays an important role in wind transitions besides photoionization changes. Simulated XRISM/Resolve and Athena/X-IFU spectra are presented to demonstrate a high fidelity of the multi-ion wind model for a better understanding of these powerful ionized winds in the coming decades

Keigo Fukumura↗