At least 19 records

Vacuum ultraviolet monochromator calibration using measured atomic branching ratios

It is noted that there now exists a compendium of experimentally measured transition probability ratios for ionized transitions of oxygen, nitrogen, and sulfur, which can be used for calibration in the VUV spectral region. The emissions proposed for use in this context span the 485-1124 A wavelength interval, and can be easily excited using low pressure discharge lamps of conventional design and dispersed using a monochromator of moderate resolution.

Morrison, M. D.↗

Problems associated with the measurement of coherence parameters - Superelastic electron scattering by laser-excited Ba-138(...6s6p1P1) atoms

Measurements of superelastic scattering of electrons by laser-excited Ba-138(...6s6p1P1) atoms were carried out. An asymmetry observed has been explained using a model of scattering from a target with finite dimensions. This model employed coherence parameters which were calculated in the distorted-wave approximation. The results indicated that the interpretation of coherence experiments in terms of scattering from a pointlike target can lead to serious errors in the deduction of coherence parameters at low scattering angles.

Zetner, P. W.↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3x10(exp 17) and 9x10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17)/cu cm. The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Bias and uncertainty in the absorption emission measurement of atomic sodium density in the SSME exit plane

The measurement of atomic sodium concentration in the TTB 019 firing of April 1990 is significant in that it represents the first measurement of density at the exit plane of the space shuttle main engine. The knowledge of the sodium density, combined with the certainty that the exit plane of the plume is optically thin at the sodium D-line wavelengths, provides essential information for evaluation of diagnostic techniques using sodium atoms, such as resonant Doppler velocimetry for temperature, pressure, and velocity through high resolution fluorescent lineshape analysis. The technique used for the sodium atom line transmission (SALT) measurements is that of resonant absorption emission using a hollow cathode lamp as the reference source. Through the use of two-dimensional kinetic (TDK) predictions of temperature and density for the flight engine case and radiative transfer calculations, this line-of-sight spectrally integrated transmission indicates a sodium atom concentration, i.e., mole fraction, of 0.91e-10. The subject of this paper is the assumptions and measurement uncertainties tied into the calculation. Because of the narrow shape of the source emission, the uncertainties in the absorption profile could introduce considerable bias in the measurement. The following were investigated: (1) the inclusion of hyperfine splitting of the D-lines in the calculation; (2) the use of the flight engine predictions of plume temperature and density versus those for the large throat engine; (3) the assumption of a Gaussian, i.e., Doppler, distribution for the source radiance with a temperature of 400 K; (4) the use of atomic collisional shift and width values for the work by Jongerius; and (5) a Doppler shift for a 7 degree outward velocity vector at the plume edge. Also included in the study was the bias introduced by an uncertainty in the measurement of the D1/D2 line ratio in the source.

Bauman, Leslie E.↗

Measurement of atomic oxygen and related airglows in the lower thermosphere

Instruments on board a sounding rocket were used to make simultaneous observations of atomic oxygen density and airglow emissions between 80 and 120 km. Atomic oxygen was measured with a resonance lamp and was found to have a peak density of 6 x 10 to the 11th at 94 km. Similar structure is seen in the oxygen density profile on both uplegs and downlegs. The following airglow emissions were measured by using vertical-viewing photometers: Herzberg I bands near 300 nm; O(1S) green line at 557.7 nm; background at 566 nm; O2(1 Delta g) bands at 1.27 microns; and OH (X 2 pi) Meinel bands near 1.7 microns.

Thomas, R. J.↗

Atomic nitrogen measurements in the upper thermosphere

The open source neutral mass spectrometer on board the Atmosphere Explorer satellites measures, besides other neutral constituents, atomic nitrogen densities in the upper thermosphere. Atomic nitrogen combines with atomic oxygen on the walls of the mass spectrometer ion source to form NO. From the measured NO concentration atomic nitrogen is deduced. Studies of the diurnal variation show that the maximum atomic nitrogen densities occur near 1600 local solar time (LST) and minimum densities near 0400 LST. The diurnal amplitude at 300 km is about a factor of 8, which is lower than predicted in present models. Atomic nitrogen also exhibits a pronounced seasonal variation with an amplitude similar to that of the diurnal variation; summer values are considerably higher than winter ones.

Mauersberger, K.↗

A Space Experiment to Measure the Atomic Oxygen Erosion of Polymers and Demonstrate a Technique to Identify Sources of Silicone Contamination

A low Earth orbital space experiment entitled, "Polymers Erosion And Contamination Experiment", (PEACE) has been designed as a Get-Away Special (GAS Can) experiment to be accommodated as a Shuttle in-bay environmental exposure experiment. The first objective is to measure the atomic oxygen erosion yields of approximately 40 different polymeric materials by mass loss and erosion measurements using atomic force microscopy. The second objective is to evaluate the capability of identifying sources of silicone contamination through the use of a pin-hole contamination camera which utilizes environmental atomic oxygen to produce a contaminant source image on an optical substrate.

Banks, Bruce A.↗

The measurement of atomic oxygen in the mesosphere and lower thermosphere

A discussion of the laboratory calibration, calibration simulation, and accuracy of a resonance fluorescence instrument for measuring oxygen atoms is presented. The discussion demonstrates that a sensor can be calibrated with good accuracy to obtain in situ measurements of the oxygen density in the mesosphere/lower thermosphere. Oxygen data are reported from six rocket flights. These data represent four midlatitude flights and two auroral flights. There are two night and two day profiles for the midlatitude experiments. The maximum densities found from these sets of data in the 90-100 km regions are between 1.5 x 10 to the 11th/cu cm and 3.5 x 10 to the 11th/cu cm. Agreement with the MSIS-86 model predictions is obtained for altitudes above 120 km for midlatitude flights. The auroral data are less than the model prediction by about a factor of 2. The data show structure that is probably indicative of gravity wave effects of a nominal 5-km vertical wavelength.

Sharp, William E.↗

In situ measurement of atomic hydrogen in the upper mesosphere

In situ measurements of H abundance between 73 and 93 km are reported for conditions of winter solstice, magnetic quiet, and a solar depression angle of 12 deg. The data were obtained by a rocket-borne instrument using the resonance fluorescence technique. A discharge source emitting photons at 1216 A was an integral part of the instrument. The instrument was radially deployed 80 cm by a boom from the front of the payload in order to avoid the shock created by the gas flow over the front of the payload. An attitude control system oriented the payload so that the gas flow was nearly perpendicular to the plane containing the incident and scattered photons, thus minimizing any correction for Doppler shift. The resonance radiation detector viewed a black backstop in order to minimize background radiation from the hydrogen geocorona; however, the background was not entirely eliminated. The signal-to-noise ratio was improved by summing the data in 1.8-s bins. The observed hydrogen concentration maximized at 85 km at 1.5 + or - 1.1 x 10 to the 8th atoms/cu cm.

Sharp, W. E.↗

Atomic Oxygen Fluence Monitor

This innovation enables a means for actively measuring atomic oxygen fluence (accumulated atoms of atomic oxygen per area) that has impinged upon spacecraft surfaces. Telemetered data from the device provides spacecraft designers, researchers, and mission managers with real-time measurement of atomic oxygen fluence, which is useful for prediction of the durability of spacecraft materials and components. The innovation is a compact fluence measuring device that allows in-space measurement and transmittance of measured atomic oxygen fluence as a function of time based on atomic oxygen erosion yields (the erosion yield of a material is the volume of material that is oxidized per incident oxygen atom) of materials that have been measured in low Earth orbit. It has a linear electrical response to atomic oxygen fluence, and is capable of measuring high atomic oxygen fluences (up to >10(exp 22) atoms/sq cm), which are representative of multi-year low-Earth orbital missions (such as the International Space Station). The durability or remaining structural lifetime of solar arrays that consist of polymer blankets on which the solar cells are attached can be predicted if one knows the atomic oxygen fluence that the solar array blanket has been exposed to. In addition, numerous organizations that launch space experiments into low-Earth orbit want to know the accumulated atomic oxygen fluence that their materials or components have been exposed to. The device is based on the erosion yield of pyrolytic graphite. It uses two 12deg inclined wedges of graphite that are over a grit-blasted fused silica window covering a photodiode. As the wedges erode, a greater area of solar illumination reaches the photodiode. A reference photodiode is also used that receives unobstructed solar illumination and is oriented in the same direction as the pyrolytic graphite covered photodiode. The short-circuit current from the photodiodes is measured and either sent to an onboard data logger, or transmitted to a receiving station on Earth. By comparison of the short-circuit currents from the fluence-measuring photodiode and the reference photodiode, one can compute the accumulated atomic oxygen fluence arriving in the direction that the fluence monitor is pointing. The device produces a signal that is linear with atomic oxygen fluence using a material whose atomic oxygen erosion yield has been measured over a period of several years in low-Earth orbit.

Banks, Bruce A.↗