Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic spectral lines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effects of screening and pressure ionization on the electron broadening of spectral lines in dense plasmas

Collisions between electrons and radiating atoms broaden spectral absorption and emission lines in dense plasmas. High densities also introduce screening and pressure ionization effects that distort the wave functions of both bound and free electrons. In order to study how dense plasma effects influence the electron broadening of spectral lines, this paper incorporates electron wave functions from an average-atom (AA) model to calculate the linewidth of the B III 2⁢𝑝−2⁢𝑠 transition at 𝑇 = 10 eV for mass densities ranging from 𝜌 = 10 −4 to 0.4⁢ g⁡/cc. The calculation method uses the impact approximation, allowing the linewidth to be written in terms of electron-collision cross sections and an interference term. Compared to an otherwise identical calculation that uses Coulomb free wave functions, the AA method is found to modify both the cross sections and the resulting linewidth at sufficiently high density by introducing screening and pressure-ionized bound states. Screening lowers the cross sections at low energies and near electron excitation thresholds, while pressure-ionized bound states introduce resonances into the continuum. Thus, as the density increases, the relative linewidth between the AA and Coulomb calculations follows a general decrease because of screening, with sharp increases at various intervals due to pressure ionization. Finally, the AA results are also compared with a common approach to introduce screening through the interaction potential and reduced models that use the Bethe formula for the inelastic electron-collision cross sections.

electronic excitation & ionization↗

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

Laser-induced fluorescence of filament-produced plasmas

Self-guided ultrafast laser filaments are a promising method for laser beam delivery and plasma generation for standoff and remote detection of elements and isotopes via filament-induced breakdown spectroscopy (FIBS). Yet, there are several challenges associated with the practical application of FIBS, including delivery of sufficient laser energy at the target for generating plasma with a copious amount of emission signals for obtaining a high signal-to-noise ratio. Here, in this study, we use laser-induced fluorescence (LIF) to boost the emission signal and reduce self-reversal in the spectral profiles. Ultrafast laser filaments were used to produce plasmas from an Al 6061 alloy target at various standoff distances from 1 to 10 m. For LIF emission enhancement, a narrow linewidth continuous-wave laser was used in resonance with a 394.40 nm Al I resonant transition, and the emission signal was monitored from the directly coupled transition at 396.15 nm. Emission signal features of Al I are significantly enhanced by resonant excitation. In addition, LIF of filament ablation plumes reduces the self-reversal features seen in the thermally excited spectral profiles. Time-resolved two-dimensional fluorescence spectroscopy was performed for evaluating the optical saturation effects, which are found to be non-negligible due to high Al atomic densities in the filament-produced plasmas.

47 OTHER INSTRUMENTATION↗

Coupling, lifetimes, and “strong coupling” maps for single molecules at plasmonic interfaces

The interaction between excited states of a molecule and excited states of a metal nanostructure (e.g., plasmons) leads to hybrid states with modified optical properties. When plasmon resonance is swept through molecular transition frequency, an avoided crossing may be observed, which is often regarded as a signature of strong coupling between plasmons and molecules. Such strong coupling is expected to be realized when 2|$\langle$U$\rangle$|/ℏΓ > 1, where $\langle$U$\rangle$ and Γ are the molecule–plasmon coupling and the spectral width of the optical transition, respectively. Because both $\langle$U$\rangle$ and Γ strongly increase with decreasing distance between a molecule and a plasmonic structure, it is not obvious that this condition can be satisfied for any molecule–metal surface distance. Here, in this work, we investigate the behavior of $\langle$U$\rangle$ and Γ for several geometries. Surprisingly, we find that if the only contributions to Γ are lifetime broadenings associated with the radiative and nonradiative relaxation of a single molecular vibronic transition, including effects on molecular radiative and nonradiative lifetimes induced by the metal, the criterion 2|$\langle$U$\rangle$|/ℏΓ > 1 is easily satisfied by many configurations irrespective of the metal–molecule distance. This implies that the Rabi splitting can be observed in such structures if other sources of broadening are suppressed. Additionally, when the molecule–metal surface distance is varied keeping all other molecular and metal parameters constant, this behavior is mitigated due to the spectral shift associated with the same molecule–plasmon interaction, making the observation of Rabi splitting more challenging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast Laser-Excited Optical Emission of Xe under Loose-Focusing Conditions

The optical filament-based radioxenon sensing can potentially overcome the constraints of conventional detection techniques that are relevant for nuclear security applications. This study investigates the spectral signatures of pure xenon (Xe) when excited by ultrafast laser filaments at near-atmosphericpressure and in short and loose-focusing conditions. The two focusing conditions lead to laser intensity differences of several orders of magnitude and different plasma transient behavior. The gaseous sample was excited at atmospheric pressure using ∼7 mJ pulses with a 35 fs pulse duration at 800 nm wavelength. The optical signatures were studied by time-resolved spectrometry and imaging in orthogonal light collection configurations in the ∼400 nm (VIS) and ∼800 nm (NIR) spectral regions. The most prominent spectral lines of atomic Xe are observable in both focusing conditions. An on-axis light collection from an atmospheric air–Xe plasma mixture demonstrates the potential of femtosecond filamentation for the remote sensing of noble gases.

47 OTHER INSTRUMENTATION↗

Four ppm measurement of the antihydrogen ground-state hyperfine splitting

The hydrogen atom is a touchstone for the foundations, evolution and frontiers of quantum theory. Key spectral lines of this atom have been determined to remarkable precision. Our research focuses on the study of antihydrogen, the antimatter counterpart of hydrogen. We test fundamental symmetries of nature (such as simultaneous charge conjugation, parity inversion, and time reversal or CPT symmetry) through precision comparisons of these atomic systems. Recent 1S–2S spectroscopic measurements on trapped antihydrogen have achieved relative precisions of parts per trillion. However, the ground-state hyperfine splitting, which is sensitive to the internal structure of the antiproton, has only been measured to 400 parts per million (ppm). Here we report a 4 ppm measurement of the antihydrogen ground-state hyperfine splitting energy a 1S , advancing the state-of-the-art precision by two orders of magnitude. From microwave spectroscopy experiments with roughly 24,000 anti-atoms, we determine ${a}_{1{\rm{S}}}/h=\mathrm{1,420,404.8}\pm 1.1(\mathrm{stat.})\pm 5.6\,(\mathrm{sys.})\,\text{kHz}$ in a 1-T magnetic field, consistent with expectations for hydrogen. At this level, our measurement is sensitive to the internal structure of the antiproton, which contributes at about 40 ppm and is approaching the limit of existing theoretical analyses. The gains we report are the product of marked advances in magnetic trap field control, stabilization and characterization; anti-atom spin-state manipulation; and improved antihydrogen accumulation rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

All-Order Full-Coulomb Quantum Spectral Line-Shape Calculations

Understanding how atoms interact with hot dense matter is essential for astrophysical and laboratory plasmas. Interactions in high-density plasmas broaden spectral lines, providing a rare window into interactions that govern, for example, radiation transport in stars. However, up to now, spectral line-shape theories employed at least one of three common approximations: second-order Taylor treatment of broadening operator, dipole-only interactions between atom and plasma, and classical treatment of perturbing electrons. In this Letter, we remove all three approximations simultaneously for the first time and test the importance for two applications: neutral hydrogen and highly ionized magnesium and oxygen. Finally, we found 15%–50% change in the spectral line widths, which are sufficient to impact applications including white-dwarf mass determination, stellar-opacity research, and laboratory plasma diagnostics.

79 ASTRONOMY AND ASTROPHYSICS↗

An experimental platform for investigation of the Zeeman effect in strong magnetic fields

An experimental platform is developed for the investigation of the Zeeman effect in strong magnetic fields. Mega-Gauss magnetic fields are generated by a 1 MA Zebra pulsed power machine using metal rod loads. A gas jet or CH oil on the load is the source of hydrogen. Excited hydrogen atoms are backlit by black body radiation from the rod load. Hydrogen absorption spectra are recorded with a grating spectrometer and intensified gated CCD camera. Furthermore, the experimental platform enables the observation of the quadratic Zeeman effect in hydrogen gas jets using the spectral shift of the central line in the Zeeman triplet. Other gases can be studied using the gas jet method.

47 OTHER INSTRUMENTATION↗

Spectral line-shape in collinear laser spectroscopy after atomic charge exchange

Collinear laser spectroscopy experiments on fast, neutral beams have been extensively used for studies on short-lived radioactive nuclei, taking advantage of its high sensitivity. The resulting resonance line-shape is known to show significant distortion, due to the energy exchange during the charge-exchange neutralization process, which can cause large systematic uncertainty in the determined centroid. A model for the line shape was constructed and simulated to be compared to measured Al, Si, and Ni hyperfine spectra. It is shown that the distortion is caused mainly by the transfer of electron into many different energy levels in the projectile atom and subsequent decays, rather than secondary inelastic collisions, which were often assumed in the line shape analysis before. Furthermore, the model can also be applied to other projectile–alkali pairs, providing a reliable line-shape with less fitting parameters than conventional phenomenological models.

Atom↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unlocking the Sun's Secrets: Laboratory Insights into the Sun's Outer Atmosphere

The Sun’s corona, its outermost and hottest atmospheric layer, emits brightly in the extreme ultraviolet (EUV) and X-rays. This emission comes from atoms that have been highly ionized by the high temperature, forming a plasma of atomic ions and free electrons. By studying this light, scientists learn about the complex and dynamic drivers of solar activity. Many past, current, and future solar observatories focus on measuring EUV spectra from the Fe IX ion, as this ion provides powerful diagnostics for solar physics. Using Fe IX spectra, solar physicists can measure the plasma temperature, density, elemental abundances, and flow velocities in the corona. However, atomic data uncertainties concerning spectral line identification and plasma density diagnostics are a major problem for the accurate interpretation of these spectra.

74 ATOMIC AND MOLECULAR PHYSICS↗

Temperature and density dependence of Kr L-shell spectrum in hot dense plasmas

Kr L-shell spectroscopy modeling results are discussed in this paper, focusing on the n = 4 to n = 2 line transitions of Be- and Li-like Kr ions. Collisional radiative atomic kinetic and Stark-broadened spectral line shape calculations show electron temperature Te and density ne sensitivity in the spectrum. The combination of the Te dependence due to the relative intensity of Be-like to Li-like line emissions in the range from 1.5 to 3 keV and the ne sensitivity from the Stark broadening effect on the line shapes in the range from 5×1023 to 2×1024/ cc results in a spectrum that can be employed to diagnose Te and ne. Two different collisional radiative atomic kinetic models i.e., Prismspect [J. J. MacFarlane, et al., Int. Fusion Sci. Appl. Conf. Proc. 457 (2003)] and ABAKO [Florido, et al., PRE, 80, 056402 (2009)] produce similar results in level populations and spectra. In x-ray spectroscopy of implosion cores, this Kr L-shell spectrum may prove useful in an intermediate Te range in which Ar is too ionized for its K-shell to be of diagnostic value and Kr is not ionized enough for its K-shell emission to be useful.

Physics↗

Fantastic Fits with fantasy of Active Galactic Nuclei Spectra: Exploring the Fe II Emission near the Hα Line

In this study, a refined approach for multicomponent fitting of active galactic nuclei (AGNs) spectra is presented utilizing the newly developed Python code Fully Automated pythoN Tool for AGN Spectra analYsis (fantasy). AGN spectra are modeled by simultaneously considering the underlying broken power-law continuum, predefined emission line lists, and an Fe II model, which is here extended to cover the wavelength range 3700–11000 Å. The Fe II model, founded solely on atomic data, effectively describes the extensive emission of the complex iron ion in the vicinity of the Hγ and Hβ lines, as well as near the Hα line, which was previously rarely studied. The proposed spectral fitting approach is tested on a sample of high-quality AGN spectra from the Sloan Digital Sky Survey Data Release 17. The results indicate that when Fe II emission is present near Hβ, it is also detected redward from Hα, potentially contaminating the broad Hα line wings and thus affecting the measurements of its flux and width. The production of Fe II emission is found to be strongly correlated with Eddington luminosity and appears to be controlled by a similar mechanism as the hydrogen Balmer lines. The study highlights the benefits of fitting type 1 AGN spectra with the fantasy code, pointing that it may be used as a robust tool for analyzing a large number of AGN spectra in the coming spectral surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of penetrating collisions of plasma ions on spectral line shapes

Spectral-line-broadening models have been moving towards including full Coulomb interactions between the atom and plasma, replacing the commonly used dipole approximation. The effects of the full Coulomb interaction have been thoroughly explored for plasma electrons, resulting in redshifts of spectral lines in high-energy-density plasmas. We explore the impact of a full Coulomb treatment on ion broadening. Penetrating collisions due to ions do not significantly impact the linewidths. The most significant aspect is the appearance of quasimolecular resonances in the far line wings, such as those previously observed in white-dwarf spectra. We identify several problems with the existing models. The most direct implementation causes the quasimolecular features to appear at the wrong photon energies. It is possible to include the detailed molecular structure, but this currently requires the Anderson-Talman approximation, which ignores the N-body properties of the plasma. We find that N-body effects can substantially broaden these quasimolecular features and even shift them, depending on the plasma conditions. We conclude that penetration of ions into the spatial extent of the radiator wave function does not strongly affect the usual diagnostics and may have a moderate to weak effect on opacity. Furthermore, the Rosseland mean opacity is weighted towards low-opacity regions of a spectrum, where these quasimolecular features are found.

79 ASTRONOMY AND ASTROPHYSICS↗

A Dirac R-matrix calculation for the electron-impact excitation of W +

Abstract Aims : tungsten has been chosen for use as a plasma facing component in the divertor for the ITER experiment, and is currently being used on existing tokamaks such as JET. W + plays an integral role in assessing the impurity influx from plasma facing component of tokamaks and subsequent redeposition. Together with previously calculated a neutral tungsten electron-impact dataset this study allows us to determine neighbouring spectral lines in the same wavelength window of the spectrometer, and detect if there is strong blending of overlapping lines between these two ion stages as well as providing ionisation per photon ratios for both species. The new data is to be used for tungsten erosion/redeposition diagnostics. Methods : a significantly modified version of the GRASP0 atomic structure code in conjunction with DARC (Dirac Atomic R -matrix Code) are used to calculate the Einstein A coefficients and collisional rates used to generate a synthetic W II spectrum. The W II spectrum is compared against tungsten spectral emission experiments. Results : this study is used to model the spectrum of W ii , providing the predictive capability of identifying spectral lines from recent experiments. These results provide an integral part of impurity influx and redeposition determination, as the ionisation rates may be used to calculate S/XB ratios.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray photoelectron spectroscopy of epitaxial films and heterostructures

X-ray photoelectron spectroscopy is a powerful experimental technique that yields invaluable information on a range of phenomena that occur in solids, liquids, and gasses. The binding energy and shape of a photoemission peak is sensitive not only to the atomic number, valence and orbital from which the electron is ejected, but also to complex many-body effects that accompany photoemission. Provided the influences of these different drivers of spectral line shapes can be disentangled, a great deal can be learned about the electronic structures of specific atoms in the material of interest. In addition to these largely local effects, the long-range electrostatic environment and resulting electric potential at the emitting atom have a direct effect on the measured binding energies. Furthermore, this fact opens the door to extracting information about the dependence of the valence and conduction band minima on depth below the surface, which in turn allows both vertical and lateral electrical transport data to be better understood. One purpose of this Report is to describe how the different physical forces described above impact spectral properties of complex oxide epitaxial films. This class of materials typically incorporates transition metal cations in different valences and of all the elements, these exhibit the most complex core-level spectra. A second purpose is to show how a comprehensive understanding of local physical effects in x-ray photoemission allows one to extract detailed information on internal electric fields and band edge discontinuities in heterostructures involving complex oxides from core-level line shapes.

47 OTHER INSTRUMENTATION↗

Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

Through a systematic scanning of 235 U and 238 U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF 6 ) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235 U– 238 U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U–238U . The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235 U– 238 U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235 U enrichment of three UF 6 samples of natural (0.720 atom% 235 U) and low-enriched (4.675 atom% and 9.157 atom% 235 U) grades. The U(I) 646.498 nm emission line, with a determined 235 U– 238 U isotopic shift of -17.7 pm, was found to be the optimal spectral window for direct UF 6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF 6 samples, with each sample measured in six replicates, was 0.31% in absolute 235 U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. In conclusion, the analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [ 235 U/( 235 U + 238 U)] ratios. Specific for the two low-enriched UF 6 samples, the relative standard deviations from six replicated measurements were around 2%.

47 OTHER INSTRUMENTATION↗