Search NASA⌕ Search

SEARCH · Search NASA

Results for “Audiology & Speech-Language Pathology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Normative Ranges for, and Interrater Reliability of, Rotational Vestibular and Balance Tests in U.S. Military Service Members and Veterans

Purpose: The objectives of this study were to (a) describe normative ranges—expressed as reference intervals (RIs)—for vestibular and balance function tests in a cohort of Service Members and Veterans (SMVs) and (b) to describe the interrater reliability of these tests. Method: As part of the Defense and Veterans Brain Injury Center (DVBIC)/Traumatic Brain Injury Center of Excellence 15-year Longitudinal Traumatic Brain Injury (TBI) Study, participants completed the following: vestibulo-ocular reflex suppression, visual-vestibular enhancement, subjective visual vertical, subjective visual horizontal, sinusoidal harmonic acceleration, the computerized rotational head impulse test (crHIT), and the sensory organization test. RIs were calculated using nonparametric methods and interrater reliability was assessed using intraclass correlation coefficients between three audiologists who independently reviewed and cleaned the data. Results: Reference populations for each outcome measure comprised 40 to 72 individuals, 19 to 61 years of age, who served either as noninjured controls (NIC) or injured controls (IC) in the 15-year study; none had a history of TBI or blast exposure. A subset of 15 SMVs from the NIC, IC, and TBI groups were included in the interrater reliability calculations. RIs are reported for 27 outcome measures from the seven rotational vestibular and balance tests. Interrater reliability was considered excellent for all tests except the crHIT, which was found to have good interrater reliability. Conclusion: This study provides clinicians and scientists with important information regarding normative ranges and interrater reliability for rotational vestibular and balance tests in SMVs.

Audiology & Speech-Language Pathology↗

Prevalence of Self-Reported Bothersome Tinnitus in U.S. Army Soldiers From January 1, 2015, Through September 30, 2019

Purpose: Tinnitus is a symptom of auditory dysfunction or injury and can be a precursor to permanent hearing loss. Tinnitus can interfere with communication, sleep, concentration, and mood; when this occurs, it is referred to as bothersome tinnitus. Annual hearing surveillance in the U.S. Army includes screening for bothersome tinnitus. Estimating the prevalence of self-reported bothersome tinnitus can facilitate prioritization of prevention and education efforts. The objective of this study was to examine Army hearing conservation data to estimate the prevalence of self-reported bothersome tinnitus as a function of age, hearing, sex, service component, and pay grade. Method: The study employed a cross-sectional, retrospective design. Records from 1,485,059 U.S. Army Soldiers retrieved from the Defense Occupational and Environmental Health Readiness System–Hearing Conservation were analyzed. Descriptive statistics and multinomial logistic regression analysis were used to estimate the prevalence of bothersome tinnitus and its associations with Soldiers' demographic characteristics. Results: The estimated prevalence of self-reported bothersome tinnitus was 17.1% between January 1, 2015, and September 30, 2019; 13.6% of the Soldiers reported “bothered a little” and 3.5% reported “bothered a lot.” Proportionally, the prevalence of self-reported bothersome tinnitus was higher for males, older Soldiers, and Reserve Component Soldiers. For every 1-year increase in age, the odds of self-reporting “bothered a little” tinnitus relative to “bothered not at all tinnitus” would be expected to increase by 2.2% (2.1%, 2.3%), and the odds of self-reporting “bothered a lot” tinnitus relative to “bothered not at all” tinnitus would be expected to increase by 3.6% (3.5%, 3.7%). Conclusions: The self-reported prevalence of bothersome tinnitus in the U.S. Army (17.1%) is substantially higher than that of the general population, where prevalence of bothersome tinnitus is estimated at 6.6%. Examination of bothersome tinnitus among Soldiers is an important step toward optimizing prevention, education, and intervention efforts.

Audiology & Speech-Language Pathology↗

Prevalence of Self-Reported Voice Concerns and Associated Risk Markers in a Nonclinical Sample of Military Service Members

Introduction: Difficult communication environments are common in military settings, and effective voice use can be critical to mission success. This study aimed to estimate the prevalence of self-reported voice disorders among U.S. military service members and to identify factors that contribute to their voice concerns. Method: A nonclinical sample of 4,123 active-duty service members was recruited across Department of Defense hearing conservation clinics. During their required annual hearing evaluation, volunteers provided responses to voice-related questions including a slightly adapted version of the Voice Handicap Index-10 (VHI-10) as part of a larger survey about communication issues. Changepoint detection was applied to age and years of service to explore cohort effects in the reporting of voice concerns. Logistic regression analyses examined multiple available factors related to communication to identify factors associated with abnormal results on the VHI-10. Results: Among the respondents, 41% reported experiencing vocal hoarseness or fatigue at least several times per year, and 8.2% ( n = 336) scored above the recommended abnormal cut-point value of 11 on the VHI-10. Factors independently associated with the greatest risk for self-reported voice concerns were sex (female), cadmium exposure, vocal demands (the need for a strong, clear voice), and auditory health measures (frequency of experiencing temporary threshold shifts; self-reported hearing difficulties). Conclusions: Based on self-reported voice concerns and false negative rates reported in the literature, the prevalence of dysphonia in a large sample of active-duty service members is estimated to be 11.7%, which is higher than that in the general population. Certain predictors for voice concerns were expected based on previous literature, like female sex and voice use, but frequency of temporary threshold shifts and exposure to cadmium were surprising. The strong link between voice and auditory problems has particular implications regarding the need for effective communication in high-noise military and other occupational environments.

Audiology & Speech-Language Pathology↗

Normative Ranges for Oculomotor and Reaction Time Tests in U.S. Military Service Members and Veterans

AbstractBackground Oculomotor and reaction time tests are frequently used assessments of vestibular symptoms, traumatic brain injury (TBI), or other neurological disorders in both clinical and research contexts. When interpreting these tests it is important to have a reference interval (RI) as a comparison for what constitutes a typical/expected response; however, the current body of research has only limited information regarding normative ranges calculated according to established standards or for a military-specific sample.Purpose The purpose of the present study was to describe RIs for oculomotor and reaction time tests in a cohort of service members and veterans (SMVs) for use as comparators by clinicians and scientists.Research Design Descriptive.Study Sample Participants were prospectively enrolled in the Defense and Veterans Brain Injury Center-Traumatic Brain Injury Center of Excellence 15-year Longitudinal Traumatic Brain Injury Study. Only SMVs without a history of TBI or blast exposure were included in the RI calculations.Data Collection and Analysis The test paradigms included in this analysis were: smooth pursuit, prosaccades, antisaccades, saccades and reaction time, predictive saccades, optokinetic nystagmus, auditory reaction time, and visual reaction time. Nonparametric methods, based on the U.S. Food and Drug Administration's recognized consensus standards, were used to calculate 95% RIs. A comparison between the calculated RIs and those available from previously published research is provided.Results Summary statistics and RIs were calculated for 47 outcome parameters from 13 oculomotor and reaction time tests. Sample sizes and age ranges varied across outcome parameters depending on the availability of reference values for RI calculations. The sample sizes used to calculate RIs ranged from 51 to 69. The age of SMVs included in each RI ranged from 19 to 61 years with mean ages ranging from 37 to 39 years. Similarities/differences between the RIs in the present study and those in previously published research are highly dependent on the outcome parameter; however, in general, the RIs in the present study tended to be somewhat wider.Conclusion The RIs provided in this paper can serve as comparisons for clinicians and scientists who are utilizing these oculomotor and reaction time testing paradigms in similar cohorts of patients or research participants.

Audiology & Speech-Language Pathology↗

Rapid method for computing the mechanical resonances of irregular objects

A solid object's geometry, density, and elastic moduli completely determine its spectrum of normal modes. Solving the inverse problem—determining a material's elastic moduli given a set of resonance frequencies and sample geometry—relies on the ability to compute resonance spectra accurately and efficiently. Established methods for calculating these spectra are either fast but limited to simple geometries, or are applicable to arbitrarily shaped samples at the cost of being prohibitively slow. Here, we describe a method to rapidly compute the normal modes of irregularly shaped objects using entirely open-source software. Our method's accuracy compares favorably with existing methods for simple geometries and shows a significant improvement in speed over existing methods for irregular geometries.

Acoustics↗

Acoustic scattering by smooth elastic cylinders insonified by directional transceivers: Monostatic theory and experiments

A theoretical model for predicting the acoustic field scattered by an elastic cylinder that is partially insonified by a directional transceiver is proposed in the form of a simple approximate one-dimensional integral. This model accounts for spherical spreading and directivity of the incident waves and extends the formulation used in a preceding article by including effects due to oblique insonification of a long cylinder assuming negligible end-contributions. The scattered field of an infinitely long cylinder for obliquely incident plane waves and point receivers is used to approximate the apparent volume flow of cylinders partially insonified by directional transceivers. The scattered pressure that is derived using the apparent volume flow, in contrast to the previous formulation, is capable of predicting axially propagating guided wave resonances; these natural modes are excited, in addition to circumferential ones, at off-normal incident angles. The model is compared with exact numerical simulations and with previously published as well as new laboratory data. The analysis illustrates the different realistic effects associated with scattering from elastic cylinders insonified by a directional transceiver both theoretically and experimentally.

42 ENGINEERING↗

Phased array-based nonlinear wave mixing technique: Application to lack-of-fusion porosity characterization in additively manufactured metals

The objective of this research is to demonstrate the effectiveness of a phased array-based nonlinear wave mixing technique to characterize internal, localized microscale damage in an additively manufactured (AM) component. By using phased arrays for the generation of the incident waves, it is possible to produce a nonlinear wave mixing scanning technique without the need for immersion or changing coupling conditions. The phased arrays can be configured to generate incident waves in multiple directions that meet the resonance conditions required for nonlinear wave mixing at a variety of internal locations. This allows for the scanning of a specimen without the removal and re-coupling of the source transducers, leading to greater scanning speed and repeatability. To demonstrate the accuracy of this phased array wave mixing approach, measurements of acoustic nonlinearity in an AM component are first made with a bulk wave second harmonic generation through thickness measurement. Next, nonlinear wave mixing measurements are made with single element transducers to confirm the sensitivity of the proposed nonlinear wave mixing approach to lack-of-fusion porosity in AM metals. Finally, phased arrays are used to highlight the effectiveness of the proposed nonlinear wave mixing technique in these same AM components.

Acoustics↗