Search NASA⌕ Search

SEARCH · Search NASA

Results for “BACKWARD WAVE OSCILLATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dielectric based submillimeter backward wave oscillator circuit

A ladder circuit especially useful in backward wave oscillators operating in the 500 GHz to 2000 GHz range has a waveguide with transversely orientated slabs which contact an upper wall of the waveguide. The edges of the slabs adjacent to the physical center of waveguide are curved segments and stubs of electrically conductive, nonmagnetic material. The ends of slabs include metal layers at opposite ends to provide a conductive leakage path. A ridge bar is attached to the inside of the bottom wall of the waveguide and includes a concave upper surface which partially straddles the electron beam. The novelty of the invention lies in the ladder structure compared of thin, vapor deposited rungs supported on the edge of diamond slabs; each rung having a curved segment which straddles the electron beam together with a ridge bar which also straddles the electron beam.

Kosmahl, H. G.↗

Submillimeter backward wave oscillators

A NASA program for the development of backward wave oscillators (BWOs) for the 500-2000 GHz frequency range is discussed. The BWO operation is based on a periodic etched slow wave structure which supports the induced traveling electromagnetic wave. The present submillimeter wave BWOs will employ a variation of the folded wave guide, the interdigital line. The use of a noncompressed electron beam results in less thermal loading of the circuit, smaller magnetic focusing fields, and higher current density of the circuit interaction region. The diamond etching procedure is described. Aluminum will be used for the metallization of the diamonds.

Dayton, J. A.↗

Submillimeter backward-wave oscillators

A novel submillimeter wave backward-wave oscillator (BWO) that can provide tens of mW of power over a voltage tunable frequency range of more than an octave could serve as the local oscillator for a new class of array sensors in the range from 200 to 2000 GHz. The BWO appears to be the best device available for supporting a wide variety of heterodyne detection systems. It is voltage tunable, able to be phase locked, and can provide sufficient power for all envisioned systems including the arrays of detectors needed for fast data recovery in monitoring upper atmospheric conditions.

Stankiewicz, N.↗

Study of optical output couplers for submillimeter wavelength backward-wave oscillators (BWO's)

Several scaled experiments of optical output couplers for submillimeter backward-wave oscillators (BWOs). Various designs of planar antennas (Vivaldi horns) lens-feed systems (hyperhemispherical lens) were constructed and tested between 20 and 100 GHz using a spectrum analyzer. The lens system was also tested at 337 GHz using a CO2 pumped FIR laser. It is found that Vivaldi horns have unsatisfactory resonances, perhaps because the horns studied were relatively short. Several techniques to maximize and flatten the frequency response of these horns are presented. The results suggest that alternate coupling schemes are superior to Vivaldi horns.

Cook, Jerry D.↗

Study of optical output couplers for submillimeter wavelength backward-wave oscillators (BWO's)

The machining of slow wave structures for high frequency backward-wave oscillators (BWO) is extremely difficult beyond 1 THz. Recently a microfabrication technique using photolithography and ion-beam assisted etching has been used to construct a prototype BWO operating at 200 to 265 GHz. The output coupler for such tubes remains a problem. Waveguides do not exist or are very lossy at the frequencies of interest (300 to 2000 GHz). This paper discusses several scaled experiments of optical output couplers for submillimeter BWOs. Various designs of planar antennas (Vivaldi horns) and lens-feed systems (Hyperhemispherical lens) were constructed and tested between 20 and 100 GHz using a spectrum analyzer. The lens system was also tested at 337 GHz using a CO2 pumped FIR laser.

Cook, Jerry D.↗

Proposed backward wave oscillation in the infrared.

Birefringence of certain crystals sufficiently large to allow collinear backward wave interaction of three electromagnetic waves with signal frequency tunable over large portion of IR SPECTRUM

INFRARED SPECTRUM↗

Evaluation of single crystal LaB6 cathodes for use in a high frequency backward wave oscillator tube

The results of thermionic emission and evaporation studies of single crystal LaB6 cathodes are given. A comparison between the (100), (210) and (310) crystal planes shows the (310) and (210) planes to possess a work function approx 0.2 eV lower than (100). This translates into a significant increase in current density, J, at a specified temperature. Comparison with a state-of-the-art impregnated dispenser cathode shows that LaB6 (310) is a superior cathode in nearly all respects except operating temperature at j 10 A/sq cm. The 1600 K thermionic and room temperature retarding potential work functions for LaB6 (310) are 2.42 and 2.50 respectively.

Swanson, L. W.↗

Accelerating particle-in-cell kinetic plasma simulations via reduced-order modeling of space-charge dynamics using dynamic mode decomposition

We present a data-driven reduced-order modeling of the space-charge dynamics for electromagnetic particle-in-cell (EMPIC) plasma simulations based on dynamic mode decomposition (DMD). The dynamics of the charged particles in kinetic plasma simulations such as EMPIC is manifested through the plasma current density defined along the edges of the spatial mesh. We showcase the efficacy of DMD in modeling the time evolution of current density through a low-dimensional feature space. Not only do such DMD based predictive reduced-order models help accelerate EMPIC simulations, they also have the potential to facilitate investigative analysis and control applications. Here, we demonstrate the proposed DMD-EMPIC scheme for reduced-order modeling of current density and speedup in EMPIC simulations involving electron beam under the influence of magnetic field, virtual cathode oscillations, and backward wave oscillator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Submillimeter local oscillators for heterodyne spectroscopy

The major technological innovations in continuous wave (CW) submillimeter sources which are specifically suitable for application as local oscillators in heterodyne systems are reviewed. A description of the various sources is given which underscores the general principles and operating features for each type of device. Particular emphasis is placed on CW optically pumped lasers, which have had a dramatic impact as widely available sources of narrow linewidth coherent radiation. The state-of-the-art is summarized for these lasers and performance data are presented for several local oscillator packages. Optically pumped lasers are then compared and contrasted with other competing sources such as backward wave oscillators, IMPATT diodes, and Josephson junctions. By comparing their advantages and limitations for use as local oscillators, the potential applications of these different sources are projected. The prospects for increased tunability, reliability, and scalability are briefly considered, and several novel techniques for generating partially tunable radiation using Schottky diode mixers or CW Raman lasers are highlighted.

Danielewicz, E. J., Jr.↗

Metamaterial-Inspired Vacuum Electron Devices and Accelerators

Metamaterials (MTMs) are structured materials with subwavelength features that can be engineered to have some unique properties not found in nature, such as negative refractive index, reversed Doppler effect, and reversed Cherenkov radiation. Based on these novel MTMs, several important research groups have made great attempts to develop novel MTM-inspired vacuum electron devices (VEDs) and accelerators. Just as solid-state power devices are innovated by incessant emerging of new semiconductor materials, VEDs can also be inspired by MTMs to have very remarkable advantages, such as smaller size, higher power, higher efficiency, and/or larger gain relative to conventional VEDs, such as traveling-wave tubes, backward-wave oscillators, and klystrons. Similarly, relative to conventional accelerators, MTM-inspired accelerators have obvious advantages, such as smaller size and higher accelerating gradient. Furthermore, MTM-inspired devices have promising applications in areas such as radar, communication, electronic warfare, microwave heating, and imaging.

43 PARTICLE ACCELERATORS↗

Ladder supported ring bar circuit

An improved slow wave circuit especially useful in backward wave oscillators includes a slow wave circuit in a waveguide. The slow wave circuit is comprised of rings disposed between and attached to respective stubs. The stubs are attached to opposing sidewalls of the waveguide. To the end that opposed, interacting magnetic fields will be established to provide a very high coupling impedance for the slow wave structure, axially orientated bars are connected between rings in alternate spaces and adjacent to the attachment points of stubs. Similarly, axial bars are connected between rings in the spaces which do not include bars and at points adjacent to the attachment of bars.

Kosmahl, H. G.↗

Technology for submillimeter wave remote sensing

NASA's sub-mm wave technology development program addresses emerging possibilities in spaceborne sensor design for what is one of the few unexplored regions of the spectrum, from 1.0 to 0.1 mm wavelengths. Astrophysics, earth atmosphere research and solar system exploration can all benefit from the development of such sensor capabilities. Technology status evaluations are presented for Shottky-diode and SIS mixers, solid state and backward wave oscillators, intermodulation frequency amplifiers, and digital autocorrelator and acoustooptic spectrometers.

Sokoloski, Martin M.↗

Slow Wave Vane Structure with Elliptical Cross-Section Slots, an Analysis

Mathematical analysis of the wave equation in cylinders with elliptical cross-section slots was performed. Compared to slow wave structures with rectangular slots higher impedance and lower power dissipation losses are evident. These features could lead to improved designs of traveling wave magnetrons and gigahertz backward-wave oscillators as well as linear traveling wave tubes with relatively shallow slots.

Kosmahl, Henry G.↗

A Low Cost Electrostatically Focused TWT

Ring-loop circuits are well known for their simplicity, low cost, compactness, low mass, high gain and efficiency and absence of backward wave oscillations. Peak powers over 20 kw have been achieved. They also have low harmonic output and excellent phase performance. We have developed a double ring-loop circuit that permits electrostatic focusing of an electron beam to at least 0.4 micro pervs. This eliminates the magnet stack and further lowers cost and weight. It permits glass rod fastening of circuit elements as well as gun and collector assemblies, as is done in cathode ray tubes. Using CRT construction techniques, the TWT can be built on automated equipment.

Vancil, Bernard K.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗