Search NASA⌕ Search

SEARCH · Search NASA

Results for “BARIUM 137”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Predicting from first principles the chemical evolution of crystalline compounds due to radioactive decay: The case of the transformation of CsCl to BaCl

In this Brief Report, we use density functional theory to predict the existence of a heretofore unobserved crystalline compound, BaCl, and additionally predict it to be isostructural with NaCl (rocksalt). Due to the chemistry of Ba, which strongly prefers a 2+ charge state, compounds where Ba nominally exhibits a +1 charge (e.g., BaCl) are unlikely to be synthesized via conventional solid-state approaches. However, in considering the chemical evolution of {sup 137}Cs to {sup 137}Ba via {beta}{sup -} radioactive decay in a model nuclear waste form CsCl, we find that BaCl may be indeed relevant. The mechanical stability of this surprising structure is confirmed through examination of its elastic constants and phonon-dispersion relations. We have also analyzed the chemical bonding of rocksalt BaCl and found it to exhibit a complex mixture of ionic, metallic, and covalent characters. From our results, we demonstrate that the chemical evolution of crystalline structures due to radioactive decay may be a viable synthesis route for unforeseen materials with interesting properties.

36 MATERIALS SCIENCE↗

Relativistic many-body calculation of energies, lifetimes, hyperfine constants, multipole polarizabilities, and blackbody radiation shift in {sup 137}Ba ii

Excitation energies of the [Xe]ns{sub 1/2}, [Xe]np{sub j}, and [Xe]nd{sub j} (n{<=} 12 and [Xe]=1s{sup 2}2s{sup 2}2p{sup 6}3s{sup 2}3p{sup 6}3d{sup 10}4s{sup 2}4p{sup 6}4d{sup 10}5s{sup 2}5p{sup 6}) in Ba ii are evaluated. First-, second-, third-, and all-order Coulomb energies and first- and second-order Coulomb-Breit energies are calculated. Electric-dipole (6s{sub 1/2}-np{sub j}, n=6-26), electric-quadrupole (6s{sub 1/2}-nd{sub j}, n=5-26), and electric-octupole (6s{sub 1/2}-nf{sub j}, n=4-26) matrix elements are calculated to obtain the ground-state E1, E2, and E3 static polarizabilities. Scalar polarizabilities of the ns{sub 1/2}, np{sub j}, and nd{sub j} states and tensor polarizabilities of the np{sub 3/2} and nd{sub j} excited states of Ba{sup +} are evaluated. All aforementioned matrix elements are determined using the relativistic all-order method. The hyperfine structure in {sup 137}Ba ii is also investigated. The hyperfine A and B values are determined for the first low-lying levels up to n=9. The quadratic Stark effect on hyperfine structure levels of {sup 137}Ba ii ground state is investigated. The calculated shift for the (F=2, M=0) {r_reversible} (F=1, M=0) transition is -0.2931 Hz/(kV/cm){sup 2}, in agreement with a previous theoretical result, -0.284(3)). These calculations provide a theoretical benchmark for comparison with experiment and theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomic interferometer measurements of Berry and Aharonov-Anandan phases for isolated spins S>(1/2) nonlinearly coupled to external fields

In a recent paper we have studied the peculiar features of the Berry and Aharonov-Anandan geometric phases for isolated spins S{>=}1. We have assumed that they are submitted to a dipole and quadrupole coupling to external E and B fields with the mild restriction E{center_dot}B=0. This implies discrete symmetries leading to remarkable simplifications of the geometry and algebra involved. The aim of the present work is to describe realistic proposals, within the realm of atomic physics, for the verification of some of our most significant theoretical predictions. There are several challenges to be overcome. For alkali-metal atoms, most commonly used in atomic interferometers, the only practical way to generate quadrupole coupling, with a strength comparable to the dipole one, is the ac Stark effect induced by a nearly resonant light beam. One then has to face the instability of the 'dressed' atom hyperfine (hf) level, a candidate for our isolated spin. One deleterious effect is the apparition of an imaginary part in the quadrupole to dipole coupling strength ratio, {lambda}. Fortunately we have found a simple way to get rid of I({lambda}) by an appropriate detuning. We are left with an unstable isolated spin. This implies an upper bound to the quantum cycle duration T{sub c}. In the case of the Berry's phase, T{sub c} has a lower bound due to the necessity of keeping the nonadiabatic corrections below a predefined level. We have found a compromise in the case of the F=2,m=0 {sup 87}Rb ground-state hf level. This is our candidate for the measurement of the somewhat ''exotic'' Berry's phase acquired by the S=2,m=0 state at the end of a quantum cycle involving a rotation of {pi} of the E field--in practice, the linear polarization of the dressing beam --about the B field direction. We have found a way to implement, in a Ramsey-type interferometric measurement, the procedures aimed at controlling the nonadiabatic corrections, as described in detail in our previous theoretical paper. A numerical simulation of our experimental proposal shows that a 0.1% accurate determination of Berry's phase, free of nonadiabatic corrections, can be achieved. Measurements could also be considered for cold {sup 52}Cr chromium atoms with S=3, where values of {lambda}{approx_equal}1 can be obtained with an instability smaller than in the {sup 87}Rb case, due to a more favorable spectroscopic structure. The F=1,m=1 hf level of the {sup 87}Rb ground state offers the opportunity to extend the measurement of Aharonov-Anandan's phases beyond the case S=(1/2). We construct, using 'light shift', the Hamiltonian H{sub ||}(t) generating a closed circuit in the density-matrix space which satisfies at any time the 'parallel transport' condition, thus making the quantum cycle free from the adiabaticity condition. We also consider the case of half-integer spins (e.g., {sup 201}Hg, {sup 135}Ba, and {sup 137}Ba), with their own specific features. We show how the difference of Berry's phases for states S=(3/2) and S=(1/2), with m=(1/2), can be exploited to achieve a holonomic maximum entanglement of three qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

REDISTRIBUTION OF ALKALINE ELEMENTS IN ASSOCIATION WITH AQUEOUS ACTIVITY IN THE EARLY SOLAR SYSTEM

It is known that the Sayama meteorite (CM2) shows an extensive signature for aqueous alteration on the meteorite parent body, and that most of the primary minerals in the chondrules are replaced with phyllosilicates as the result of the aqueous alteration. In this paper, it is confirmed from the observation of two-dimensional Raman spectra that a part of olivine in a chondrule collected from the Sayama chondrite is serperntinized. Ion microprobe analysis of the chondrule showed that alkaline elements such as Rb and Cs are heterogeneously redistributed in the chondrule. The result of higher Rb and Cs contents in serpentinized phases in the chondrule rather than in other parts suggested the selective adsorption of alkaline elements into the serpentine in association with early aqueous activity on the meteorite parent body. Furthermore Ba isotopic analysis provided variations of {sup 135}Ba/{sup 138}Ba and {sup 137}Ba/{sup 138}Ba in the chondrule. This result was consistent with our previous isotopic data suggesting isotopic evidence for the existence of the presently extinct nuclide {sup 135}Cs in the Sayama meteorite, but the abundance of {sup 135}Cs in the solar system remains unclear because of large analytical uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Formation of hyperdeformed states by neutron emission from a dinuclear system

The hyperdeformed nuclei treated as dinuclear or quasimolecular configurations are suggested to be directly produced in heavy-ion reactions at bombarding energies near the Coulomb barrier. The excited dinuclear system formed in the entrance channel of the heavy-ion collision can be cooled down by neutron emission to be transformed into the hyperdeformed nuclear system. This transition from the excited dinuclear system to a hyperdeformed configuration is described within the statistical approach. The reactions {sup 48}Ca+{sup 124,128,130,132,134}Sn, {sup 48}Ca+{sup 136,138}Xe, {sup 48}Ca+{sup 137,138,140}Ba, {sup 40}Ca+{sup 83,84}Kr, {sup 48}Ca+{sup 83,84,86}Kr, {sup 40,48}Ca+{sup 40,48}Ca, {sup 58,60}Ni+{sup 58,60}Ni, and {sup 40}Ca+{sup 58}Ni are suggested for the population of hyperdeformed states. The production cross sections, quadrupole moments, and moments of inertia of hyperdeformed states formed in these reactions are calculated, and the optimal conditions for the experimental identification of such states are proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

State detection using coherent Raman repumping and two-color Raman transfers

We demonstrate state detection based on coherent Raman repumping and a two-color Raman state transfer. The Raman coupling during detection selectively eliminates unwanted dark states in the fluorescence cycle without compromising the immunity of the desired dark state to off-resonant scattering. We demonstrate this technique using {sup 137}Ba{sup +} where a combination of Raman coupling and optical pumping leaves the metastable state, D{sub 3/2} |F''=3,m{sub F}{sup ''}=3>, optically dark and immune to off-resonant scattering. All other states are strongly coupled to the upper P{sub 1/2} levels. We achieve a single-shot state-detection efficiency of 89.6(3)% in a 1-ms integration time, limited almost entirely by technical imperfections. Shelving to |F{sup ''}=3,m{sub F}{sup ''}=3> before detection is performed via a two-color Raman transfer with a fidelity of 1.00(3).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pseudogap and anharmonic phonon behavior in Ba{sub 8}Ga{sub 16}Ge{sub 30}: An NMR study

We have performed {sup 69}Ga, {sup 71}Ga, and {sup 137}Ba NMR on Ba{sub 8}Ga{sub 16}Ge{sub 30}, a clathrate semiconductor which has been of considerable interest due to its large figure of merit for thermoelectric applications. In measurements from 4 K to 450 K, we used measurements on the two Ga nuclei to separate the magnetic and electric quadrupole hyperfine contributions and thereby gain information about the metallic and phonon behavior. The results show the presence of a pseudogap in the Ga electronic states within the conduction band, superposed upon a large Ba contribution to the conduction band. Meanwhile the phonon contributions to the Ga relaxation rates are large and increase more rapidly with temperature than typical semiconductors. These results provide evidence for enhanced anharmonicity of the propagative phonon modes over a wide range, providing experimental evidence for enhanced phonon-phonon scattering as a mechanism for the reduced thermal conductivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-induced caesium-137 decay

Experimental data are presented on the laser-induced beta decay of caesium-137. We demonstrate that the exposure of a gold target to a copper vapour laser beam (wavelengths of 510.6 and 578.2 nm, pulse duration of 15 ns) for 2 h in an aqueous solution of a caesium-137 salt reduces the caesium-137 activity by 70%, as assessed from the gamma activity of the daughter nucleus {sup 137m}Ba, and discuss potential applications of laser-induced caesium-137 decay in radioactive waste disposal. (letters)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Exchange Column Thermal Modeling: Prevention of Process Effluent Boiling - 18577

The Savannah River Site treats and disposes of legacy high-level waste, which resulted from 60 years of nuclear material production, medical research, and other nuclear related work. Complex mixtures of soluble and insoluble solids occupy tanks of which the South Carolina Department of Health and Environmental Control recognizes as the single largest environmental risk state-wide. The risk is reduced through removal, treatment, and solidification of decontaminated salt waste. Presently, SRS decontaminates the soluble salt component of the waste, a solution containing actinides and cesium, via implementation of the Actinide Removal Process and the Modular Caustic Side Solvent- Extraction Unit. Caustic solvent extraction is set to increase in scale by late 2018, with startup of the newly constructed Salt Waste Processing Facility. In conjunction with Salt Waste Processing Facility startup, Savannah River Remediation has been tasked by the Department of Energy to demonstrate modular ion exchange technology. The Tank Closure Cesium Removal project aims to demonstrate the feasibility of modular ion exchange processes for future Department of Energy applications. The Tank Closure Cesium Removal system is scheduled to begin operation in mid-2018. Dissolved salt solution, or influent, will be fed through a filter and ion exchange columns in lead-lag configuration, producing effluent. The effluent is fed to a separate high-level waste tank, for future disposition at Salt-stone Production Facility. Once the demonstration project is complete, the loaded ion exchange columns will be purged, dried, and placed in interim safe storage, awaiting final disposition. The ion exchange media selected for the Tank Closure Cesium Removal system is Honeywell UOP IONSIV{sup C} R-9120. The media is a prime candidate for separation of cesium from radioactive high-level waste. UOP R-9120{sup C} is inorganic and has high capacity, selectivity, and affinity for cesium. During operation, influent is fed to the ion exchange columns, contacting UOP R-9210{sup C} packed within the media vessel. Contact initiates loading of isotopes, and given ample time the solid phase (ion exchange media) and solution achieve thermodynamic equilibrium. UOP R-9120{sup C} is a prime candidate for separation of cesium and dissolved fission products. Although the properties of UOP R-9120{sup C} are favorable for separation, the same properties lead to accumulation of a heat source in the ion exchange bed. Cesium-137 and its daughter product, barium-137 m, generate a clear majority of heat (i.e. ∼ 94%). During operation salt solution flows through each column and transports heat from the ion exchange bed. Once operation is terminated, the effluent contained within the porous bed volume becomes essentially static. In the absence of engineering controls, the heat generated may boil the effluent. Rapid vaporization of aqueous salt solution would lead to bed over pressurization. Over pressurization and an associated release of high-level waste would result in adverse impacts to human health and the environment. This paper focuses on modeling the heat transfer associated with the Tank Closure Cesium Removal system ion exchange column. The model evaluates the maximum heat generation and the associated radionuclide loadings that prevent boiling within of the media vessel, under no flow conditions. A safety significant control, maintaining loadings less than the established loading limit ensures associated impacts to human health and the environment are prevented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Testing of Alkaline Earth Metal Ion Absorption on Crystalline Silicotitanate - 20440

The Tank Closure Cesium Removal process at the Savannah River Site (SRS) has processed aqueous tank waste using the inorganic ion exchange media IONSIV{sup TM} R9120-Ba (which is also known as Crystalline Silicotitanate (CST)). Salt-cake in Tank 10H at SRS was dissolved and processed through filters and ion exchange columns. The primary purpose of the process is to remove Cs-137 from the aqueous waste so that it can be disposed as low level waste. It is known that this inorganic media also absorbs strontium from solution, and that strontium competes with cesium ions for absorption sites. The strontium ion is actually more strongly absorbed than the cesium ion from typical tank waste. However, strontium is typically present in low concentrations so does not normally cause a significant impact. Strontium is present as both non-radioactive isotopes and the radioactive Sr-90 isotope; with the non-radioactive isotopes being much more abundant. Although the total strontium solubility is usually much lower than cesium, some tank waste compositions can have a high enough soluble strontium concentration to decrease the cesium absorption. Relatedly, some testing at SRS suggested that another alkaline earth metal, calcium, may also absorb onto CST and may decrease cesium absorption. Barium is also an important species in treatment of tank waste, but is also usually present at low concentrations. However, after the Cs-137 is absorbed onto CST, it emits a beta particle and converts to Ba-137m, which then decays to non-radioactive Ba-137 by emission of a gamma ray. If the Ba-137m were to desorb quickly, it could impact the dose rate in down-stream equipment. In order to understand the impact of these alkaline earth metals on CST, SRNL performed testing using simulants of SRS tank waste that contain soluble barium, strontium, and calcium. Testing examined both removal of the alkaline earth metals and their impact on removal of cesium. Testing involved first developing realistic waste simulant formulations and dissolving the alkaline earth metals to high enough concentrations to potentially impact the Cs absorption. Once the formulations were developed and prepared, computer modeling was used to calculate the expected Cs absorption behavior to determine if the alkaline earth metals impact the performance. Measurements of the alkaline earth metals absorption by the media is also important for disposition of spent media because of the added radionuclide inventory from the Sr-90. These initial tests are examining the general impact and will be used to determine if further testing or measurements are needed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Barium Ions for Quantum Computation

Individually trapped {sup 137}Ba{sup +} in an RF Paul trap is proposed as a qubit candidate, and its various benefits are compared to other ionic qubits. We report the current experimental status of using this ion for quantum computation. Future plans and prospects are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of radiological data of some amino acids in the energy range 0.122-1.330MeV

Radiological parameters such as μ{sub m}, σ{sub t}, σ{sub e}, Z{sub eff} and N{sub eff} of amino acids, namely Lysine (C{sub 6}H{sub 15}N{sub 2}O{sub 2}), Histidine (C{sub 6}H{sub 9}N{sub 3}O{sub 2}) and Arginine (C{sub 6}H{sub 15}N{sub 4}O{sub 2}), were measured using NaI (Tl)-based gamma spectrometry. Radioactive sources used in the study are {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 54}Mn, {sup 60}Co and {sup 22}Na. Gamma ray transmission method in a narrow beam good geometry set up was used in the study. The measured data were compared against XCOM-based data. The agreement is within 2%.

07 ISOTOPE AND RADIATION SOURCES↗

Inspection of a LOCA test rod at the Halden reactor project using gamma emission tomography

The LOCA test series IFA-650 conducted at the OECD Halden Reactor Project (HRP) has provided unique data on the performance of fuel rods during LOCA transients. One focus of the current investigations is the performance of the fuel in the ballooning stage of the LOCA transient. In this stage, relocation of fuel material is a possibility, in which case pellet fragments fall down to fill the void introduced by the increased volume of the ballooned cladding. This increases the heat load in that region, further promoting corrosion of the cladding. A special concern in the case of high-burnup fuels is the increasing number of small fuel fragments, which may be expected to cause a higher packing fraction in the ballooned region. In this work, a novel technique is presented for assessing the average density of the fuel material in the ballooned region of LOCA test rods. The investigation is based on non-destructive gamma emission tomography measurements, using the dedicated instrument recently developed at the HRP in collaboration with Westinghouse (Sweden) and Uppsala University. In this approach, the gamma radiation field surrounding the test rod has been measured with a narrowly collimated HPGe detector. Tomographic reconstruction of the data was performed, providing the radial gamma-ray source distribution within the measured volume, which reveals the fuel fragment distribution. From this, the density of the fuel in the measured volume (i.e., the packing fraction) may be calculated. The technique has been used to investigate a LOCA test rod of the Halden Reactor Project LOCA series. The LOCA experiment was carried out about one month prior to the gamma tomography examination. The results show that the distribution of the relocated fuel can be imaged using gamma rays from fission products. The reconstructions of the 662 keV rays from {sup 137}Cs and 1596 keV from {sup 140}Ba/La are demonstrated. In addition, the peaks of activation products offer valuable information on the location of the test rig structures, which may be utilized in a quantitative tomographic reconstruction to assess the spatially resolved packing fraction. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Instrument for precision long-term β-decay rate measurements

We describe an experimental setup for making precision measurements of relative β-decay rates of {sup 22}Na, {sup 36}Cl, {sup 54}Mn, {sup 60}Co, {sup 90}Sr, {sup 133}Ba, {sup 137}Cs, {sup 152}Eu, and {sup 154}Eu. The radioactive samples are mounted in two automated sample changers that sequentially position the samples with high spatial precision in front of sets of detectors. The set of detectors for one sample changer consists of four Geiger-Müller (GM) tubes and the other set of detectors consists of two NaI scintillators. The statistical uncertainty in the count rate is few times 0.01% per day for the GM detectors and about 0.01% per hour on the NaI detectors. The sample changers, detectors, and associated electronics are housed in a sealed chamber held at constant absolute pressure, humidity, and temperature to isolate the experiment from environmental variations. The apparatus is designed to accumulate statistics over many years in a regulated environment to test recent claims of small annual variations in the decay rates. We demonstrate that absent this environmental regulation, uncontrolled natural atmospheric pressure variations at our location would imprint an annual signal of 0.1% on the Geiger-Müller count rate. However, neither natural pressure variations nor plausible indoor room temperature variations cause a discernible influence on our NaI scintillator detector count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioisotope identification method for poorly resolved gamma-ray spectrum of nuclear security concern

Gamma-ray signal can be used as a fingerprint for radioisotope identification. In the context of radioactive and nuclear materials security at the border control point, the detection task can present a significant challenge due to various constraints such as the limited measurement time, the shielding conditions, and the noise interference. This study proposes a novel method to identify the signal of one or several radioisotopes from a poorly resolved gamma-ray spectrum. In this method, the noise component in the raw spectrum is reduced by the wavelet decomposition approach, and the removal of the continuum background is performed using the baseline determination algorithm. Finally, the identification of radioisotope is completed using the matrix linear regression method. The proposed method has been verified by experiments using the poorly resolved gamma-ray signals from various scenarios including single source, mixing of natural uranium with five of the most common industrial radioactive sources (57Co, 60Co, 133Ba, 137Cs, and 241Am). The preliminary results show that the proposed algorithm is comparable with the commercial method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Leachate Treatment for Radioactive Waste Containment Mound: Pilot Test and Design - 19098

Canadian Nuclear Laboratories plans to construct an engineered containment mound (ECM) at its Chalk River Laboratories site in Ontario for safe management of radioactive and mixed waste at the facility. The ECM is designed for containment of 1,000,000 cubic meters of waste, and will be operated over a period of 50 years. Contact storm water, leachate, and other wastewater will be generated during operation of the ECM, and must be treated prior to discharge to the environment. The wastewater is projected to contain low concentrations of radionuclides and metals, as well as other cations and anions, and low concentrations of organic chemicals. Through comparison with surface water discharge criteria, radionuclides cesium-137 and strontium-90, and metals including aluminum, barium, copper, iron, lead, and manganese were projected to be present in the wastewater at concentrations that may exceed surface water discharge criteria, and were therefore targeted for treatment. Several technologies, including chemical precipitation, membrane filtration, ion exchange, and reverse osmosis were reviewed and tested on a laboratory scale using simulated wastewater prepared to replicate the concentrations of both target and non-target constituents. Based upon the results of the laboratory-scale tests, a six-week pilot test was conducted to simulate the performance of the technologies under continuous-flow conditions and determine full-scale design criteria. This paper describes the methodology and results of the six-week pilot test, and how the test results were used to inform the full-scale wastewater treatment system design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Further Development of an ISOCS - based Advanced In Situ Gamma Spectrometry Services Tool for Waste Measurements - 17452

Canberra's In Situ Object Counting System is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function while avoiding the need for radioisotope standards. The ISOCS Uncertainty Estimator tool can be used to calculate defensible systematic calibration uncertainties. However the uncertainties depend on knowledge of the properties of the item being measured and for poorly characterized materials these can be large, often leading to large costs for waste sentencing. An ISOCS-based advanced in-situ gamma spectrometry services tool has been developed to reduce those uncertainties. This system is based on generating and comparing a range of candidate geometry models that yield figures of merit indicative of improved consistency between modelled data and available diverse measurement data. The approach and results of initial performance testing have previously been published, demonstrating an analysis procedure and enhanced accuracy for measurement of a low density 200 litre waste drum, based on measurements with known sources placed at different positions. It was shown how the accuracy of assay of Am-241 in a light matrix can be significantly improved. Further analysis has now been performed, with reference to measurements of a second drum, containing a standard matrix of higher density, and with a multiple radionuclide line source (Ba-133, Cs-137, Eu-152 and Am-241). These measurements represent a more challenging waste assay scenario, corresponding to potentially much larger assay uncertainties. Our results show how the assay uncertainty can be reduced, by careful application of AIGS, from relative values of the order of 100% to a few 10's of %. Furthermore, we demonstrate, through extended analysis of the test drum data, how an AIGS measurement program can be optimized to reduce the number of required measurement positions substantially. This paper describes these new results with comment on their importance and potential application for real waste assay projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of In-Situation Radioactivity Inspection System for Food Materials

The impacts on the ocean of releases of radionuclides from the Fukushima nuclear power plants remain unclear. Korean people worry about radioactive contamination of Japanese and Korean sea products. Radioactive contamination of processed foodstuffs, livestock, sea products, farm products imported from Japan and fishes caught in coastal oceans of Korea has become an important social issue. Recently, there are also needs of inspection system for monitoring of public meals such like school feedings of kindergarten, elementary/middle/high school and university. Radioactivity inspections of food materials have been executed manually with portable measuring instruments or at labs using their samples. But, it's very important the radioactivity inspection should be performed at the field of feeding facilities. To protect the health of people from radioactivity contained in Japanese marine products imported to Korea, a system to inspect radioactivity in real time has been developed. The system is to measure the radioactivity level of farm and marine products and public meals continuously and automatically at inspection sites of an agency checking radiation of imported foodstuffs or school. The performance test of NaI(Tl) detector was examined using the quantified Cs-137 source 10 Bq/kg, 30 Bq/kg, 50 Bq/kg, 300 Bq/kg and 900 Bq/kg at Korea Research Institute of Standards and Science(KRISS). Source was put in a box and radioactivity was measured in the middle of the box. First of all, Background was measured and calibration was performed using the Cs-137 300 Bq and Ba-133 3700 Bq for 60 minutes. After setting the background and calibration data, tests of the Cs-137 10, 30, 50, 300, 900 Bq/kg were executed for 10 minutes. A peak-shaped graph is shown at the location of 662 KeV (80∼100 channel). This is due to the gamma radiation energy with 662 KeV emitted by the Cs-137. Because through KRISS examination, the MDA (minimum detectable activity) is about 23 Bq/kg, it is reasonable Cs-137 10 Bq/kg cannot be measured. And in cases of Cs-137 300 Bq/kg and 900 Bq/kg, there are some peak movement on the graph. It can be adjusted by controlling gain or high voltage. The examination was identified through the performance test (Cs-137 10, 30, 50, 300, 900 Bq/kg) at KRISS. In order to increase the measurement efficiency of Cs-137 and the system performance, database will be built up based on radioactivity measurement results from 10 to 300 Bq/kg with the unit 10. Thus, Cs-137 concentration of food materials can be identified below the maximum permissible concentration of 100 Bq/kg on a basis of the spectrum characteristic of Cs-137. Also, anxiety about radioactive contamination of foods after the Fukushima nuclear accident will be eased and trust of the radioactive inspection is expected definitely. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗