Search NASA⌕ Search

SEARCH · Search NASA

Results for “BARIUM 140”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A=140☆

The 2006 evaluation of A=140 was updated using experimental results published before November 2018 from the various reaction and decay studies leading to the nuclei {sup 140}Sb, {sup 140}Te, {sup 140}I, {sup 140}Xe, {sup 140}Cs, {sup 140}Ba, {sup 140}La, {sup 140}Ce, {sup 140}Pr, {sup 140}Nd, {sup 140}Pm, {sup 140}Sm, {sup 140}Eu, {sup 140}Gd, {sup 140}Tb, {sup 140}Dy, {sup 140}Ho. These data are summarized and presented, together with adopted level schemes and properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of {sup 140}La fission product interference factor for INAA

Instrumental Neutron Activation Analysis (INAA) is a technique widely used to determine the concentration of several elements in several kinds of matrices. However if the sample of interest has higher relative uranium concentration the obtained results can be interfered by the uranium fission products. One of these cases that is affected by interference due to U fission is the {sup 140}La, because this radioisotope used in INAA for the determination of concentration the La is also produced by the {sup −}β of {sup 140}Ba, an uranium fission product. The {sup 140}La interference factor was studied in this work and a factor to describe its time dependence was obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inspection of a LOCA test rod at the Halden reactor project using gamma emission tomography

The LOCA test series IFA-650 conducted at the OECD Halden Reactor Project (HRP) has provided unique data on the performance of fuel rods during LOCA transients. One focus of the current investigations is the performance of the fuel in the ballooning stage of the LOCA transient. In this stage, relocation of fuel material is a possibility, in which case pellet fragments fall down to fill the void introduced by the increased volume of the ballooned cladding. This increases the heat load in that region, further promoting corrosion of the cladding. A special concern in the case of high-burnup fuels is the increasing number of small fuel fragments, which may be expected to cause a higher packing fraction in the ballooned region. In this work, a novel technique is presented for assessing the average density of the fuel material in the ballooned region of LOCA test rods. The investigation is based on non-destructive gamma emission tomography measurements, using the dedicated instrument recently developed at the HRP in collaboration with Westinghouse (Sweden) and Uppsala University. In this approach, the gamma radiation field surrounding the test rod has been measured with a narrowly collimated HPGe detector. Tomographic reconstruction of the data was performed, providing the radial gamma-ray source distribution within the measured volume, which reveals the fuel fragment distribution. From this, the density of the fuel in the measured volume (i.e., the packing fraction) may be calculated. The technique has been used to investigate a LOCA test rod of the Halden Reactor Project LOCA series. The LOCA experiment was carried out about one month prior to the gamma tomography examination. The results show that the distribution of the relocated fuel can be imaged using gamma rays from fission products. The reconstructions of the 662 keV rays from {sup 137}Cs and 1596 keV from {sup 140}Ba/La are demonstrated. In addition, the peaks of activation products offer valuable information on the location of the test rig structures, which may be utilized in a quantitative tomographic reconstruction to assess the spatially resolved packing fraction. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Splitting of the Pygmy Dipole Resonance

In recent years investigations have been made to study the electric Pygmy Dipole Resonance (PDR) systematically, mainly in semi-magic nuclei. For this purpose the well understood high resolution ({gamma},{gamma}') photon scattering method is used. In complementary ({alpha},{alpha}'{gamma}) coincidence experiments at E{sub {alpha}} = 136 MeV a similar {gamma}-energy resolution and a high selectivity to E1 transitions can be obtained at the Big-Bite Spectrometer (BBS) at KVI, Groningen. In comparison to the ({gamma},{gamma}') method a structural splitting of the PDR is observed in the N = 82 nuclei {sup 138}Ba and {sup 140}Ce and in the Z = 50 nucleus {sup 124}Sn. The low energy part is excited in ({gamma},{gamma}') as well as in ({alpha},{alpha}'{gamma}) while the high energy part is observed in ({gamma},{gamma}') only. The experimental results together with theoretical QPM and RQTBA calculations on {sup 124}Sn which are able to reproduce the splitting of the PDR qualitatively are presented. The low-lying group of J{sup {pi}} = 1{sup -} states seem to represent the more isoscalar neutron-skin oscillation of the PDR while the energetically higher-lying states seemingly belong to the transitional region between the PDR and the isovector Giant Dipole Resonance (IVGDR).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synergistic extraction of rare earth elements, actinium, americium, and barium with TTA and Pb resin from acetate buffer solutions

The uptake behavior of 88 Y, 140 Ba, 140 La, 141 Ce, 152 Eu, 228 Ac, and 241 Am was studied with batch uptake, kinetics and column studies in a synergistic extraction system with Pb resin and 2-thenoyltrifuoroacetone in acetate-ethanol solutions. The k' values are very high (>10,000) at near neutral pH (~5 to 6) for all of the radioisotopes studied. The kinetics are reasonably fast for column separations, though the uptake rate is dependent on the concentration of 2-thenoyltrifuoroacetone. Column studies were performed to demonstrate the separation of the trivalent actinides and lanthanides from barium and common fssion products ( 99 Mo, 103 Ru).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Helium gas bubble trapped in liquid helium in high magnetic field

High magnetic field magnets are used widely in the area of the condensed matter physics, material science, chemistry, geochemistry, and biology at the National High Magnetic Field Laboratory. New high field magnets of state-of-the-art are being pursued and developed at the lab, such as the current developing 32 T, 32 mm bore fully superconducting magnet. Liquid Helium (LHe) is used as the coolant for superconducting magnets or samples tested in a high magnetic field. When the magnetic field reaches a relatively high value the boil-off helium gas bubble generated by heat losses in the cryostat can be trapped in the LHe bath in the region where BzdBz/dz is less than negative 2100 T{sup 2}/m, instead of floating up to the top of LHe. Then the magnet or sample in the trapped bubble region may lose efficient cooling. In the development of the 32 T magnet, a prototype Yttrium Barium Copper Oxide coil of 6 double pancakes with an inner diameter of 40 mm and an outer diameter of 140 mm was fabricated and tested in a resistive magnet providing a background field of 15 T. The trapped gas bubble was observed in the tests when the prototype coil was ramped up to 7.5 T at a current of 200 A. This letter reports the test results on the trapped gas bubble and the comparison with the analytical results which shows they are in a good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GE Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.

60 APPLIED LIFE SCIENCES↗

Synthesis of molecular metallic barium superhydride: pseudocubic BaH 12

Following the discovery of high-temperature superconductivity in the La–H system, we studied the formation of new chemical compounds in the barium-hydrogen system at pressures from 75 to 173 GPa. Using in situ generation of hydrogen from NH 3 BH 3 , we synthesized previously unknown superhydride BaH 12 with a pseudocubic (fcc) Ba sublattice in four independent experiments. Density functional theory calculations indicate close agreement between the theoretical and experimental equations of state. In addition, we identified previously known P6/mmm-BaH 2 and possibly BaH 10 and BaH 6 as impurities in the samples. Ab initio calculations show that newly discovered semimetallic BaH 12 contains H 2 and H 3 – molecular units and detached H 12 chains which are formed as a result of a Peierls-type distortion of the cubic cage structure. Barium dodecahydride is a unique molecular hydride with metallic conductivity that demonstrates the superconducting transition around 20 K at 140 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TWO BARIUM STARS IN THE OPEN CLUSTER NGC 5822

Open clusters are very useful examples to explain the constraint of the nucleosynthesis process with the luminosities of stars because the distances of the clusters are better known than those of field stars. We carried out a detailed spectroscopic analysis to derive the chemical composition of two red giants in the young open cluster NGC 5822, NGC 5822-2, and NGC 5822-201. We obtained abundances of C, N, O, Na, Mg, Al, Ca, Si, Ti, Ni, Cr, Y, Zr, La, Ce, and Nd. The atmospheric parameters of the studied stars and their chemical abundances were determined using high-resolution optical spectroscopy. We employed the local thermodynamic equilibrium model atmospheres of Kurucz and the spectral analysis code MOOG. The abundances of the light elements were derived using the spectral synthesis technique. We found that NGC 5822-2 and -201 have, respectively, a mean overabundance of the elements created by the s-process, ''s'', with the notation [s/Fe] of 0.77 {+-} 0.12 and 0.83 {+-} 0.05. These values are higher than those for field giants of similar metallicity. We also found that NGC 5822-2 and -201 have, respectively, luminosities of 140 L{sub Sun} and 76 L{sub Sun }, which are much lower than the luminosity of an asymptotic giant branch star. We conclude that NGC 5822-2 and NGC 5822-201 are two new barium stars first identified in the open cluster NGC 5822. The mass transfer hypothesis is the best scenario to explain the observed overabundances.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasma waves associated with the AMPTE artificial comet

Numerous plasma wave effects were detected by the AMPTE/IRM spacecraft during the artificial comet experiment on December 27, 1984. As the barium ion cloud produced by the explosion expanded over the spacecraft, emissions at the electron plasma frequency and ion plasma frequency provided a determination of the local electron density. The electron density in the diamagnetic cavity produced by the ion cloud reached a peak of more than 5 x 10 to the 5th per cu cm, then decayed smoothly as the cloud expanded, varying approximately as t exp-2. As the cloud began to move due to interactions with the solar wind, a region of compressed plasma was encountered on the upstream side of the diamagnetic cavity. The peak electron density in the compression region was about 1.5 x 10 to the 4th per cu cm. Later, a very intense (140 mVolt/m) broadband burst of electrostatic noise was encountered on the sunward side of the compression region. This noise has characteristics very similar to noise observed in the earth's bow shock, and is believed to be a shocklike interaction produced by an ion beam-plasma instability between the nearly stationary barium ions and the streaming solar wind protons.

Gurnett, D. A.↗

Large electromechanical strain and unconventional domain switching near phase convergence in a Pb-free ferroelectric

In many ferroelectrics, large electromechanical strains are observed near regions of composition- or temperature- driven phase coexistence. Phenomenologically, this is attributed to easy re-orientation of the polarization vector and/or phase transition, although their effects are highly convoluted and difficult to distinguish experimentally. Here, we used synchrotron X-ray scattering and digital image correlation to differentiate between the microscopic mechanisms leading to large electrostrains in an exemplary Pb-free piezoceramic Sn-doped barium calcium zirconate titanate. Large electrostrains of ~0.2% measured at room-temperature are attributed to an unconventional effect, wherein polarization switching is aided by a reversible phase transition near the tetragonal-orthorhombic phase boundary. Additionally, electrostrains of ~0.1% or more could be maintained from room temperature to 140°C due to a succession of different microscopic mechanisms. In situ X-ray diffraction elucidates that while 90° domain reorientation is pertinent below the Curie temperature ( T C ), isotropic distortion of polar clusters is the dominant mechanism above T C .

36 MATERIALS SCIENCE↗

Overview of the SPARC tokamak

The SPARC tokamak is a critical next step towards commercial fusion energy. SPARC is designed as a high-field ( $B_0 = 12.2$ T), compact ( $R_0 = 1.85$ m, $a = 0.57$ m), superconducting, D-T tokamak with the goal of producing fusion gain $Q>2$ from a magnetically confined fusion plasma for the first time. Currently under design, SPARC will continue the high-field path of the Alcator series of tokamaks, utilizing new magnets based on rare earth barium copper oxide high-temperature superconductors to achieve high performance in a compact device. The goal of $Q>2$ is achievable with conservative physics assumptions ( $H_{98,y2} = 0.7$ ) and, with the nominal assumption of $H_{98,y2} = 1$ , SPARC is projected to attain $Q \approx 11$ and $P_{\textrm {fusion}} \approx 140$ MW. SPARC will therefore constitute a unique platform for burning plasma physics research with high density ( $\langle n_{e} \rangle \approx 3 \times 10^{20}\ \textrm {m}^{-3}$ ), high temperature ( $\langle T_e \rangle \approx 7$ keV) and high power density ( $P_{\textrm {fusion}}/V_{\textrm {plasma}} \approx 7\ \textrm {MW}\,\textrm {m}^{-3}$ ) relevant to fusion power plants. SPARC's place in the path to commercial fusion energy, its parameters and the current status of SPARC design work are presented. This work also describes the basis for global performance projections and summarizes some of the physics analysis that is presented in greater detail in the companion articles of this collection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ba{sub 3}GeS{sub 5} and Ba{sub 3}InS{sub 4}Cl: Interesting size effects originated from the tetrahedral anions

Two new barium chalcogenides, Ba{sub 3}GeS{sub 5} and Ba{sub 3}InS{sub 4}Cl, were synthesized by using high temperature solid-state reactions and their structures were determined by single-crystal X-ray diffraction technique. Despite the similar chemical formula, the structures of Ba{sub 3}GeS{sub 5} and Ba{sub 3}InS{sub 4}Cl are subtly different due to the size effects originated from the tetrahedral anions. Ba{sub 3}GeS{sub 5} crystallizes in the orthorhombic space group Pnma (no. 62) with cell parameters of a=12.0528(9) Å, b=9.5497(7) Å and c=8.5979(6) Å, while Ba{sub 3}InS{sub 4}Cl adopts a different tetragonal system (space group: I4/mcm, no. 140, a=b=8.3613(6) Å, c=14.3806(18) Å). The measured optical band gap of Ba{sub 3}GeS{sub 5} is 3.0 eV, a little smaller than the value of 3.42 eV in Ba{sub 3}InS{sub 4}Cl. Theoretical calculations by Wien2k are provided as well in order to better understand these results. - Graphical abstract: The polyhedral structure view for Ba{sub 3}GeS{sub 5} and Ba{sub 3}InS{sub 4}Cl in which Ba, S and Cl atoms are plotted in purple, red and green spheres. - Highlights: • Two new barium chalcogenides, Ba{sub 3}GeS{sub 5} and Ba{sub 3}InS{sub 4}Cl, were synthesized from the BaCl{sub 2}-flux reactions. • Their crystal structures feature discrete [MS{sub 4}] tetrahedra which embody interesting size effects. • Both compounds exhibit a band gap around 3.0 eV. • They are thermally stable up to 1073 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FY-15 Progress Report on Cleanup of irradiated SHINE Target Solutions Containing 140g-U/L Uranyl Sulfate

During FY 2012 and 2013, a process was developed to convert the SHINE Target Solution (STS) of irradiated uranyl sulfate (140 g U/L) to uranyl nitrate. This process is necessary so that the uranium solution can be processed by the UREX (Uranium Extraction) separation process, which will remove impurities from the uranium so that it can be recycled. The uranyl sulfate solution must contain <0.02 M SO 4 2- so that the uranium will be extractable into the UREXsolvent. In addition, it is desired that the barium content be below 0.0007 M, as this is the limit in the Resource Conservation and Recovery Act (RCRA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical clocks: using otolith geochemistry to enhance estimation of age and growth of white hake (Urophycis tenuis)

The white hake (Urophycis tenuis) is a groundfish distributed throughout the Gulf of Maine. Catch advice is based on stock assessments done with age-based population dynamics models; however, otolith aging is challenging because of unclear growth increments. To address this concern, we compared the consistency of aging with counts of visual annuli to that of aging with cycles of elemental concentrations measured by using laser ablation inductively coupled plasma mass spectrometry. We tested the hypothesis that oscillations in both environmental conditions and internal physiology through time influence uptake of elements during otolith mineralization. Concentrations of manganese, in comparison with those of the other investigated trace elements (magnesium, strontium, and barium), had the most promising correlation with visual growth increments (~100% age agreement, ±1 year), offering an additional tool to enhance increment identification. In our examination of 550 otoliths collected during 2007–2021, we found that white hake lived a maximum of 10.3 years and exhibited sexual dimorphism in maximum length and age. By using generated von Bertalanffy growth functions, L(t)=110(1–e–0.113(t+0.45)) for males and L(t)=140(1–e–0.113(t–0.30)) for females (where L(t) is length at time t), size and age at maturity were calculated for males (37.4 cm in total length (TL), 3.3 years) and females (47.4 cm TL, 4.2 years). These results demonstrate that otolith geochemistry can be used to improve the accuracy and precision of the estimation of fish age and maturity, even for challenging species.

59 BASIC BIOLOGICAL SCIENCES↗

Anomalous magneto-elastic and charge doping effects in thallium-doped BaFe 2 As 2

Within the BaFe 2 As 2 crystal lattice, we partially substitute thallium for barium and report the effects of interlayer coupling in Ba 1-x Tl x Fe 2 As 2 crystals. We demonstrate the unusual effects of magneto-elastic coupling and charge doping in this iron-arsenide material, whereby Néel temperature rises with small x, and then falls with additional x. Specifically, we find that Néel and structural transitions in BaFe 2 As 2 (TN = T s = 133 K) increase for x = 0.05 (T N = 138 K, T s = 140 K) from magnetization, heat capacity, resistivity, and neutron diffraction measurements. Evidence from single crystal X-ray diffraction and first principles calculations attributes the stronger magnetism in x = 0.05 to magneto-elastic coupling related to the shorter intraplanar Fe-Fe bond distance. With further thallium substitution, the transition temperatures decrease for x = 0.09 (T N = T s = 131 K), and this is due to charge doping. Finally, we illustrate that small changes related to 3d transition-metal state can have profound effects on magnetism.

36 MATERIALS SCIENCE↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterizing the Distribution of Microwave Surface Resistance of HTS Film Based on Metal Ring

This paper presents a novel method for measuring the microwave surface resistance distribution of high-temperature superconducting thin films by a dielectric resonator with a metal ring. After calibration, the effect of metal ring loss on measurement accuracy is negligible. The measurement resolution is determined by the internal diameter of the metal ring, which makes the design of the device more flexible. Therefore, measurement with high resolution and convenience can be achieved simultaneously by using a metal ring with proper size and operating at a relatively low frequency. A test device working at 32 GHz with TE{sub 01(1 + δ)} mode was developed. Its resolution is a circular area with a diameter of 5 mm and an area of 19.6 mm{sup 2}. The unloaded quality factor of the test device is more than 140,000, when it is loaded by the calibration cavity. The test device has a relative uncertainty of less than 6%, which complies with the uncertainty (20%) specified by the international standard for the microwave surface resistance measurement of high-temperature superconducting (HTS) thin film. The surface resistance distribution of a 2-in. YBCO/LAO/YBCO superconducting film sample was measured by this test device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗