Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gas Filled RF Resonator Hadron Beam Monitor for Intense Neutrino Beam Experiments

MW-class beam facilities are being considered all over the world to produce an intense neutrino beam for fundamental particle physics experiments. A radiation-robust beam monitor system is required to diagnose the primary and secondary beam qualities in high-radiation environments. We have proposed a novel gas-filled RF-resonator hadron beam monitor in which charged particles passing through the resonator produce ionized plasma that changes the permittivity of the gas. The sensitivity of the monitor has been evaluated in numerical simulation. A signal manipulation algorithm has been designed. A prototype system will be constructed and tested by using a proton beam at the MuCool Test Area at Fermilab.

43 PARTICLE ACCELERATORS↗

SU-E-T-251: Developing a Daily Proton Beam Monitoring System

Purpose: To develop a daily monitoring system for proton beam output check and beam uniformity check. Methods: Designed for continuously irradiated photon and electron beams with a field size of 20 cm x 20 cm, the daily output checker (Sun Nuclear, Inc.) is not suitable for monitoring proton beams with inter-pulse beam-off and a field size smaller than 14–16 cm in diameter. To allow such proton beam monitoring, the following tests were performed. 1. Absolute dose and array calibrations which accept continuous irradiation only, were performed using photon beams. 2. Five ion chambers within the central area of 8 cm x 8 cm were utilized to check constancy of output at the center of beam modulation and at distal edge and to check beam symmetry and flatness. 3. To simplify our evaluation, the array calibration was manually modified, such that all five chambers report equal values in spite of their differences in build-up thicknesses. 4. The chamber at the lower-right corner is placed under a buildup thickness that can offer dose measurement at the distal edge. This buildup thickness was determined by proton beam range measurements, which established buildup thickness for beam output measurement at the central chamber and range measurement at the corner chamber. 5. The beam-off delay which allows receipt of pulsed irradiation was activated and optimal delay times were determined for each proton beam at 149.6, 185.6, and 249.5 MeV. Results: The above system was tested by miss-steering proton beams and altering phantom thickness by 1 mm at a time. The system reliably monitored the beam with: 3% tolerance for beam flatness, symmetry and output. The range difference of 0.5 mm could be detected at all energies by setting a tolerance of 20%. Conclusion: A quick daily proton beam monitoring system was feasible.

07 ISOTOPE AND RADIATION SOURCES↗

Plastic scintillator block as photon beam monitor for EGRET calibration

The EGRET (Energetic Gamma Ray Experiment Telescope) detector has been calibrated at SLAC (Stanford Linear Accelerator) and, to a lesser degree, at the MIT Bates Linear Accelerator Center. To monitor the photon beams for the calibration, a plastic scintillator block, 5 cm x 5 cm in cross section, 15 cm in length, and viewed by a single photomultiplier tube, was used for the entire beam energy range of 15 MeV to 10 GeV. The design operation, and method of analysis of the beam intensity are presented. A mathematical framework has been developed to treat the general case of a beam with multiphoton beam pulses and with a background component. A procedure to deal with the fluctuations of the beam intensity over a data-taking period was also developed. The photon beam monitor is physically sturdy, electronically steady, simple to construct, and easy to operate. Its major merits lie in its sheer simplicity of construction and operation and in the wide energy range it can cover.

Lin, Y. C.↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

X-ray beam monitoring and wavelength calibration using four-beam diffraction

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Development of a synchrotron radiation beam monitor for the Integrable Optics Test Accelerator

Nonlinear integrable optics applied to beam dynamics may mitigate multi-particle instabilities, but proof of principle experiments have never been carried out. The Integrable Optics Test Accelerator (IOTA) is an electron and proton storage ring currently being built at Fermilab, which addresses tests of nonlinear lattice elements in a real machine in addition to experiments on optical stochastic cooling and on the single-electron wave function. These experiments require an outstanding control over the lattice parameters, achievable with fast and precise beam monitoring systems. This work describes the steps for designing and building a beam monitor for IOTA based on synchrotron radiation, able to measure intensity, position and transverse cross-section beam.

43 PARTICLE ACCELERATORS↗

MO-F-CAMPUS-T-05: Design of An Innovative Beam Monitor for Particle Therapy for the Simultaneous Measurement of Beam Fluence and Energy

Purpose: Monitoring the prescribed dose in particle therapy is typically carried out by using parallel plate ionization chambers working in transmission mode. The use of gas detectors has several drawbacks: they need to be calibrated daily against standard dosimeters and their dependence on beam quality factors need to be fully characterized and controlled with high accuracy. A detector capable of single particle counting is proposed which would overcome all these limitations. Combined with a gas ionization chamber, it will allow determining the average particle stopping power, thus providing an effective method for the online verification of the selected particle energy and range. Methods: Low-Gain Avalanche Detectors (LGADs) are innovative n-in-p silicon sensors with moderate internal charge multiplication occurring in the strong field generated by an additional p+ doping layer implanted at a depth of a few µm in the bulk of the sensor. The increased signal-to-noise ratio allows designing very thin, few tens of microns, segmented LGADs, called Ultra Fast Silicon Detectors (UFSD), optimized for very fast signal, which would be suitable for charged particle counting at high rates. A prototype UFSD is being designed for this purpose. Results: Different LGAD diodes have been characterized both in laboratory and beam tests, and the results compared both with those obtained with similar diodes without the gain layer and with a program simulating the signal in the sensors. The signal is found to be enhanced in LGADs, while the leakage current and the noise is not affected by the gain. Possible alternative designs and implementations are also presented and discussed. Conclusion: Thanks to their excellent counting capabilities, UFSD detectors are a promising technology for future beam monitor devices in hadron-therapy applications. Studies are ongoing to better understand their properties and optimize the design in view of this application.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

Preliminary Designs for Modifications to the X-Ray Source and Beam Monitor of the Marshall Space Flight Center's X-Ray Calibration Facility

Preliminary designs for modifications to the X-ray source and beam monitor of the MSFC X-Ray Calibration Facility to meet requirements for the calibration of the Advanced X-Ray Astrophysics Facility are considered. A rhodium plated copper target and rhodium foil filter are proposed as a source of X-rays of approximately 2.6 keV energy. Bragg scattering of the unpolarized X-ray beam from the present source through an angle of 90 deg by a single crystal placed on the axis of the guide tube is proposed as a source of approximately monoenergetic plane polarized X-rays. A sealed xenon proportional counter with a Beryllium window is proposed as a beam monitor for use between 2.5 and 8 keV to obtain improved detection efficiency.

Croft, W. L.↗

Laser wakefield accelerated electron beam monitoring and control

We will discuss our participation in the ImPACT project, which has as one of its goals the development of an ultra-compact electron accelerator using lasers (< 1 GeV, < 10 m) and the generation of an x-ray beam from the accelerated electrons. Within this context we will discuss our investigation into electron beam monitoring and control. Since laser accelerated electrons will be used for x-ray beam generation combined with an undulator, we will present investigation into the possibilities of the improvement of electron beam emittance through cooling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extracting source parameters from beam monitors on a chopper spectrometer

The intensity distributions of beam monitors in direct-geometry time-of-flight neutron spectrometers provide important information about the instrument resolution. For short-pulse spallation neutron sources in particular, the asymmetry of the source pulse may be extracted and compared to Monte Carlo source simulations. An explicit formula using a Gaussian-convolved Ikeda-Carpenter distribution is given and compared to data from the ARCS instrument at the Spallation Neutron Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of a proton phase beam monitor for range verification in proton therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and are directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a phase beam monitor can be performed. A first prototype of phase beam monitor was tested at GSI Darmstadt, where measurements of the energy profile of the ion bunches were performed. At the ELBE accelerator Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Oncoray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionizing-radiation beam monitoring system

Embodiments are directed generally to an ionizing-radiation beam monitoring system that includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam. Embodiments further include at least one scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and at least one ultraviolet illumination source within the enclosure structure and facing the scintillator. At least one pixelated imaging system within the enclosure structure is located out of an incident ionizing-radiation beam path and includes at least one pixelated photosensor device optically coupled to an imaging lens.

Friedman, Peter S.↗

Correcting Magnetic-Field Diffusion Effects in Beam Position Monitors

Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.

43 PARTICLE ACCELERATORS↗