A Novel Ultrasonic Fully Reversible Bending Fatigue Test Specimen for Simulated Gear Tooth Bending Fatigue
Gears in vertical lift applications will typically experience greater than 107bending fatigue cycles over their design lifetime. Currently, fatigue life prediction of gears exceeding 107cycles are based on empirical correlations, since collection of fatigue data beyond 107 cycles is impractical with traditional fatigue testing methods. Ultrasonic fatigue testing enables fatigue testing in excess of 109cycles in as few as 14 hours. In this paper, a novel specimen design for ultrasonic fatigue testing to accurately represent the geometry, stress profile, and residual stress of gear teeth in reversible bending fatigue is presented. The specimen design is discussed in detail, testing is performed to validate operating principles, and an initial fatigue data set of 8 specimens is presented.