Search NASA⌕ Search

SEARCH · Search NASA

Results for “BESSY II”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The EMIL project at BESSY II: Beamline design and performance

The Energy Materials In-Situ Laboratory Berlin (EMIL) at BESSY-II is currently under construction. Two canted undulators for soft- and hard X-rays will be installed into the BESSY II storage ring in one straight section, complex beamlines with more than twenty optical elements will be set up and a new laboratory building attached to BESSY II will host three endstations and a large UHV-transfer system connecting various HV- and UHV-deposition systems. The undulators, UE48 and U17, provide a broad energy spectrum of 80 - 10000 eV, of which the harder radiation (>700 eV) is provided by a cryogenic in-vacuum device. Three monochromators (two plane grating monochromators (PGM) and one LN{sub 2}-cooled double crystal monochromator (DCM)) disperse the radiation into separate pathways of 65 m length, while downstream of the monochromators split-mirror chambers distribute the photon beam to one (or simultaneously to two) of five upcoming endstations. Three of these endstations are designed for the full energy range with spatial overlap of the soft and hard foci, whereas one endstation (PEEM) uses only the soft and another one (PINK) only the hard branch, respectively.

43 PARTICLE ACCELERATORS↗

A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II

We present multitone harmonic-balance (MTHB) simulations of a Ti-Au x-ray transition-edge sensor (TES) microcalorimeter in a 5x5 pixel spectrometer array. The dynamic response of the TES microcalorimeter under simulation has been extremely well characterized at the BESSY II Synchrotron Radiation Facility in Berlin. We compare our simulated results directly with these measurements, and show that the MTHB algorithm is able to simulate to great accuracy the dynamic behavior of the TES, even when saturated by 6 keV photons. In this paper, we provide a detailed account of the MTHB simulations, and discuss the impact of this work on future missions such as the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compensation of Beam Line Polarizing Effects at UE112 of BESSY II

Reflections in synchrotron radiation beam lines tend to change the state of polarization of the radiation. This effect is more pronounced for steep angle of incidence, i.e. at low photon energy (say below 100 eV) beam lines. The APPLE II undulator UE112 at BESSY has all four magnetic rows shiftable and thus generates any state of polarization. To provide any intended polarization state at the sample we perform polarization measurements based on simple and fast linear polarization analysis that together with calculations of the undulator radiation predicts undulator settings that cancel beam line polarization effects.

43 PARTICLE ACCELERATORS↗

Development of a new generation of optical slope measuring profiler

We overview the results of a broad US collaboration, including all DOE synchrotron labs (ALS, APS, BNL, NSLS-II, LLNL, LCLS), major industrial vendors of x-ray optics (InSync, Inc., SSG Precision Optronics-Tinsley, Inc., Optimax Systems, Inc.), and with active participation of HBZ-BESSY-II optics group, on development of a new generation slope measuring profiler -- the optical slope measuring system (OSMS). The desired surface slope measurement accuracy of the instrument is<50 nrad (absolute) that is adequate to the current and foreseeable future needs for metrology of x-ray optics for the next generation of light sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALICE—An advanced reflectometer for static and dynamic experiments in magnetism at synchrotron radiation facilities

We report on significant developments of a high vacuum reflectometer (diffractometer) and spectrometer for soft x-ray synchrotron experiments which allows conducting a wide range of static and dynamic experiments. Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. The versatility of the instrument was testified by a series of pilot experiments. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses to excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. We demonstrate here the capabilities of the system to host a variety of experiments, featuring ALICE as one of the most versatile and demanded instruments at the Helmholtz Center in Berlin-BESSY II synchrotron center in Berlin, Germany.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deflection gating for time-resolved x-ray magnetic circular dichroism-photoemission electron microscopy using synchrotron radiation

In this paper, we present a newly developed gating technique for a time-resolving photoemission microscope. The technique makes use of an electrostatic deflector within the microscope's electron optical system for fast switching between two electron-optical paths, one of which is used for imaging, while the other is blocked by an aperture stop. The system can be operated with a switching time of 20 ns and shows superior dark current rejection. We report on the application of this new gating technique to exploit the time structure in the injection bunch pattern of the synchrotron radiation source BESSY II at Helmholtz-Zentrum Berlin for time-resolved measurements in the picosecond regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response

CEA implemented an absolutely calibrated broadband soft X-ray spectrometer called DMX on the Omega laser facility at the Laboratory for Laser Energetics (LLE) in 1999 to measure radiant power and spectral distribution of the radiation of the Au plasma. The DMX spectrometer is composed of 20 channels covering the spectral range from 50 eV to 20 keV. The channels for energies below 1.5 keV combine a mirror and a filter with a coaxial photo-emissive detector. For the channels above 5 keV the photoemissive detector is replaced by a conductive detector. The intermediate energy channels (1.5 keV < photon energy < 5 keV) use only a filter and a coaxial detector. A further improvement of DMX consists in flat-response X-ray channels for a precise absolute measurement of the photon flux in the photon energy range from 0.1 keV to 6 keV. Such channels are equipped with a filter, a Multilayer Mirror (MLM), and a coaxial detector. We present as an example the development of channel for the gold M emission lines in the photon energy range from 2 keV to 4 keV which has been successfully used on the OMEGA laser facility. The results of the radiant power measurements with the new MLM channel and with the usual channel composed of a thin titanium filter and a coaxial detector (without mirror) are compared. All elements of the channel have been calibrated in the laboratory of the Physikalisch-Technische Bundesanstalt, Germany's National Metrology Institute, at the synchrotron radiation facility BESSY II in Berlin using dedicated well established and validated methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EPU correction scheme study at the CLS

The Canadian Light Source (CLS) Quantum Materials Spectroscopy Center (QMSC) beamline will employ a novel double period (55 mm, 180 mm) elliptically polarizing undulator (EPU) to produce photons of arbitrary polarization in the soft X-ray regime. The long period and high field of the 180 mm period EPU will have a strong dynamic focusing effect on the storage ring electron beam. We have considered two partial correction schemes, a 4 m long planar array of BESSY-II style current strips, and soft iron L-shims. In this paper we briefly consider the implementation of these correction schemes.

43 PARTICLE ACCELERATORS↗

A KB-Focusing Mirror Pair for a VUV-Raman Spectrometer at FLASH - Mirror Metrology and Ray Tracing Results

A plane mirror and two strongly curved plane elliptical mirrors comprising the refocusing system downstream the plane grating monochromator at FLASH in DESY have been characterized with the Nanometer Optical Component Measuring Machine at the BESSY-II Optics Laboratory of the Helmholtz Zentrum Berlin. Based on the measurement results the two elliptical cylinders were optimized by deterministic surface finishing technology (Ion Beam Finishing). The expected focusing performance was verified by ray tracings after each ion beam finish iteration using the measured topography results.

43 PARTICLE ACCELERATORS↗

Calibration of a two-color soft x-ray diagnostic for electron temperature measurement

The two-color soft x-ray (SXR) tomography diagnostic on the Madison Symmetric Torus is capable of making electron temperature measurements via the double-filter technique; however, there has been a 15% systematic discrepancy between the SXR double-filter (SXR{sub DF}) temperature and Thomson scattering (TS) temperature. Here we discuss calibration of the Be filters used in the SXR{sub DF} measurement using empirical measurements of the transmission function versus energy at the BESSY II electron storage ring, electron microprobe analysis of filter contaminants, and measurement of the effective density. The calibration does not account for the TS and SXR{sub DF} discrepancy, and evidence from experiments indicates that this discrepancy is due to physics missing from the SXR{sub DF} analysis rather than instrumentation effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by using an analytical model for the relatively simple sample geometry and applying it to numerical forward simulations of the optical Fresnel propagation, we show that quantitative measurements of the microgap width down to 0.1 {mu}m are possible. Image data recorded at the BAMline (BESSY-II light source, Germany) are presented, with the resolving power of the imaging system being 4 {mu}m in absorption mode and {approx}14 {mu}m in phase contrast mode (z{sub 2}=0.74 m). Thus, phase contrast radiography, combined with numerical forward simulations, is capable of measuring the widths of gaps that are two orders of magnitude thinner than the conventional detection limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Hemisphere Fermi Surface Mapping Using A Novel Toroidal Electron Spectrometer

An overview is provided of a next-generation toroidal angle-resolving photoemission spectrometer, currently in operation at BESSY II. The instrument features exceptional multi-detection in energy and angle, facilitating rapid full-hemisphere photoemission measurements. The instrument is ideal for band structure and Fermi Surface (FS) mapping using Angle Resolved Photoemission Spectroscopy (ARPES). Recent full-hemisphere FS measurements of a prototypical material, copper, reveal previously unseen fine structure due to lifetime broadening, demonstrating the high angular resolution and dense {kappa}-space sampling capabilities of the instrument.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The X-ray microscopy beamline UE46-PGM2 at BESSY

The Max Planck Institute for Metal Physics in Stuttgart and the Helmholtz Center Berlin operate a soft X-ray microscopy beamline at the storage ring BESSY II. A collimated PGM serves as monochromator for a scanning X-ray microscope and a full field X-ray microscope at the helical undulator UE46. The selection between both instruments is accomplished via two switchable focusing mirrors. The scanning microscope (SM) is based on the ALS STXM microscope and fabricated by the ACCEL company. The full field microscope (FFM) is currently in operation at the U41-SGM beamline and will be relocated to its final location this year.

43 PARTICLE ACCELERATORS↗

Multi-MHz time-of-flight electronic bandstructure imaging of graphene on Ir(111)

In the quest for detailed spectroscopic insight into the electronic structure at solid surfaces in a large momentum range, we have developed an advanced experimental approach. It combines the 3D detection scheme of a time-of-flight momentum microscope with an optimized filling pattern of the BESSY II storage ring. Here, comprehensive data sets covering the full surface Brillouin zone have been used to study faint substrate-film hybridization effects in the electronic structure of graphene on Ir(111), revealed by a pronounced linear dichroism in angular distribution. The method paves the way to 3D electronic bandmapping with unprecedented data recording efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser-induced modification of potassium-magnesium silicate glasses: An analysis of structural changes by near edge x-ray absorption spectroscopy

The effects of femtosecond laser pulse irradiation on the glass structure of alkaline silicate glasses were investigated by x-ray absorption near edge structure spectroscopy using the beamline of the Physikalisch-Technische Bundesanstalt at the electron synchrotron BESSY II in Berlin (Germany) by analyzing the magnesium K-edge absorption peak for different laser fluences. The application of fluences above the material modification threshold (2.1 J/cm{sup 2}) leads to a characteristic shift of {approx}1.0 eV in the K-edge revealing a reduced ({approx}3%) mean magnesium bond length to the ligated oxygen ions (Mg-O) along with a reduced average coordination number of the Mg ions.

36 MATERIALS SCIENCE↗

Ultrafast x-ray photoelectron spectroscopy in the microsecond time domain

We introduce a new approach for ultrafast in situ high-resolution X-ray photoelectron spectroscopy (XPS) to study surface processes and reaction kinetics on the microsecond timescale. The main idea is to follow the intensity at a fixed binding energy using a commercial 7 channeltron electron analyzer with a modified signal processing setup. This concept allows for flexible switching between measuring conventional XP spectra and ultrafast XPS. The experimental modifications are described in detail. As an example, we present measurements for the adsorption and desorption of CO on Pt(111), performed at the synchrotron radiation facility BESSY II, with a time resolution of 500 μs. Due to the ultrafast measurements, we are able to follow adsorption and desorption in situ at pressures of 2 × 10{sup −6} mbar and temperatures up to 500 K. The data are consistently analyzed using a simple model in line with data obtained with conventional fast XPS at temperatures below 460 K. Technically, our new approach allows measurement on even shorter timescales, down to 20 μs.

36 MATERIALS SCIENCE↗