Search NASA⌕ Search

SEARCH · Search NASA

Results for “BESTEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) 2023 [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf The purpose of this repository is to generate BESTEST test case models, run simulations, and populate data for ASHRAE Standard 140 reporting spreadsheets for EnergyPlus® based whole building simulation tools. It was originally setup for 2014 version of Standard 140. In May of 2022 it was updated to the 2020 version of Standard 140. This update included updates and additions to existing test suites, the bulk of which was in Section 5.2 (Building Thermal Envelope and Fabric Load Tests). We did not add Section 5.5 Airside HVAC Equipment Performance, but we hope to add that later in 2022. At some point we also hope to add Section 5.2.4 ground modeling, which is currently excluded. Supported Tools The default IDF generation is based on the OpenStudio® CLI, but the workflow supports a 'Bring your own IDF' use case. Additionally, for non-EnergyPlus® based tools the post processing scripts can be used if simulation results are provided as a CSV file.The scripts on this repository should work on Mac, Windows, and Linux. Dependencies Install OpenStudio® 3.4.0 make sure command line can recognize the 'openstudio' command This includes EnergyPlus® 22.1 Install Ruby on your system if it isn't already setup. 2.7 is used for development but other versions may work Since OpenStudio has its own embedded Ruby, which is used for running measures, you don't necessarily have to use a version of Ruby supported by OpenStudio. Install RubyXL Ruby gem This is used to modify Microsoft Excel spreadsheets Install Parallel Ruby gem This allows the CLI to run simulations in parallel

Goldwasser, David↗

Update of ASHRAE Standard 140 Section 5.2 and Related Sections (BESTEST Building Thermal Fabric Test Cases)

This report documents new work intended to update the current building thermal fabric software-to-software comparative test specifications and example results of ANSI/ASHRAE Standard 140-2017, Sections 5.2.1, 5.2.2, 5.2.3, and related supporting sections. The Building Energy Simulation Test and Diagnostic Method (BESTEST) test specification and example results that provide the basis for these Standard 140 sections were originally published in 1995. The state of the art in building energy simulation modeling has advanced since then. Additionally, comments on the test specification over the years highlighted ambiguities, further necessitating the update to the original work. This new work was conducted for the U.S. Department of Energy (DOE) by Argonne National Laboratory (Argonne) and National Renewable Energy Laboratory (NREL), in collaboration with a working group of international experts associated with the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standing Standard Project Committee (SSPC) 140. SSPC 140 is responsible for ANSI/ASHRAE Standard 140. The new work, presented in this report, defined the test cases and specifications such that building energy simulation programs with time steps of one hour or less can perform the tests. Revisions to the test specification and update of example results follow the vetting process of iterative field trials established for previous BESTEST work that has been adapted for ASHRAE Standard 140.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of window scheduler algorithm exploiting natural ventilation and thermal mass for building energy simulation and smart home controls

Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.

42 ENGINEERING↗

Developing Equivalent Surface Heat Transfer Input Parameters for Updated Standard 140/BESTEST Thermal Fabric Test Cases

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, is widely cited for evaluating software for use with performance-path energy efficiency analysis in conjunction with well-known energy-efficiency standards, including: ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. This paper summarizes recent work to develop improved equivalent surface heat transfer input parameters for the building thermal fabric comparative test cases that comprise a portion of Standard 140. The software-to-software comparative test method allows comparison of simulation results from a wide variety of building energy simulation programs to each other. In this type of test method, it is of great importance to specify inputs that are as well-equivalenced as possible to accommodate a wide variety of input schemes for the tested programs, and thereby reduce the potential for disagreements among them in the tests. Results include new alternative constant surface coefficients that are appropriate to the test cases and demonstrate their ability to approximate the more detailed surface heat transfer models from which they are derived.

BESTEST↗