Search NASA⌕ Search

SEARCH · Search NASA

Results for “BETA DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of influence of plastic scintillators thicknesses to detect Beta particles and Gamma radiation by means of spectral analysis of {sup 90}Sr, {sup 90}Y and {sup 137}Cs sources

The Nuclear and Energy Research Institute - IPEN, offers post-graduate programs, namely: Nuclear Technology - Applications (TNA), Nuclear Technology - Materials (TNM), Nuclear Technology - Reactors (TNR). The Institute programs mission is to form expert technicians, physicists and engineers with a strong knowledge in their discipline to work in the nuclear area. The course: 'Theoretical Fundamentals and Practices of the Instrumentation used in Nuclear Data Acquisition' covers the use of laboratory nuclear instrumentation and the accomplishment of experiments to obtain nuclear parameters. One of these experimental exercises is object of this work: 'Study of influence of plastic scintillators to detect Beta particles and Gamma radiation by means of spectral analysis of {sup 90}Sr, {sup 90}Y and {sup 137}Cs sources'. The use of scintillators plastic for the detection has the advantage of low cost, high mechanical strength, is not hygroscopic and can be manufactured in large volumes. This work aims to present the analysis of relative efficiency of detection of plastic scintillators of various thicknesses for beta particles and gamma radiation by the spectrum of {sup 137}Cs and {sup 90}Sr. Due to lack of resolution of the detectors plastic scintillators we worked with relative efficiency. The evaluation was done by reading deposited energy, using the software MAESTRO, for each detector thickness. For beta particles was observed an ideal thickness around 3 mm and the better photon efficiency was observed with increasing the thickness of the detector. The present experiment does not intend to establish a new technique for this subject: it solely aims student's practical exercises in nuclear properties of elements and detectors being part of the nuclear experimental course. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method, apparatus and system for low-energy beta particle detection

An apparatus, method, and system relating to radiation detection of low-energy beta particles are disclosed. An embodiment includes a radiation detector with a first scintillator and a second scintillator operably coupled to each other. The first scintillator and the second scintillator are each structured to generate a light pulse responsive to interaction with beta particles. The first scintillator is structured to experience full energy deposition of low-energy beta particles, and permit a higher-energy beta particle to pass therethrough and interact with the second scintillator. The radiation detector further includes a light-to-electrical converter operably coupled to the second scintillator and configured to convert light pulses generated by the first scintillator and the second scintillator into electrical signals. The first scintillator and the second scintillator have at least one mutually different characteristic to enable an electronic system to determine whether a given light pulse is generated in the first scintillator or the second scintillator.

36 MATERIALS SCIENCE↗

keV scale {nu}{sub R} dark matter and its detection in {beta} decay experiments

We study dark matter (DM) in the model with one keV scale right-handed neutrino {nu}{sub R1} and two GeV scale right-handed neutrinos {nu}{sub R2,3}, the {nu}SM. We find that one of the GeV scale right-handed neutrinos can have a much longer lifetime than the other when two GeV scale right-handed neutrinos are degenerate. We show that the mass and mixing of light neutrinos can be explained in this case. Significant entropy release can be generated in a reheating produced by the decay of one of the GeV scale {nu}{sub R}. The density of {nu}{sub R1} DM can be diluted by 2 orders of magnitude, and the mixing of {nu}{sub R1} with active neutrinos is allowed to be much larger, reaching the bound from x-ray observation. This mixing can lead to a sizable rate of {nu}{sub R1} capture by radioactive nuclei. The {nu}{sub R1} capture events are mono-energetic electrons with keV scale energy away from the beta decay spectrum. This is a new way to detect DM in the Universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid Crystal Enabled Early Stage Detection of Beta Amyloid Formation on Lipid Monolayers

Liquid crystals (LCs) can serve as sensitive reporters of interfacial events, and this property has been used for sensing of synthetic or biological toxins. Here it is demonstrated that LCs can distinguish distinct molecular motifs and exhibit a specific response to beta-sheet structures. That property is used to detect the formation of highly toxic protofibrils involved in neurodegenerative diseases, where it is crucial to develop methods that probe the early-stage aggregation of amyloidogenic peptides in the vicinity of biological membranes. In the proposed method, the amyloid fibrils formed at the lipid-decorated LC interface can change the orientation of LCs and form elongated and branched structures that are amplified by the mesogenic medium; however, nonamyloidogenic peptides form ellipsoidal domains of tilted LCs. Moreover, a theoretical and computational analysis is used to reveal the underlying structure of the LC, thereby providing a detailed molecular-level view of the interactions and mechanisms responsible for such motifs. The corresponding signatures can be detected at nanomolar concentrations of peptide by polarized light microscopy and much earlier than the ones that can be identified by fluorescence-based techniques. As such, it offers the potential for early diagnoses of neurodegenerative diseases and for facile testing of inhibitors of amyloid formation.

Sadati, Monirosadat↗

Validation of MCNPX-PoliMi code for simulations of radioxenon beta-gamma coincidence detection

Radioxenon detection is an important component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty. We developed and validated a new model in MCNPX-PoliMi to simulate the decay of various radioxenon isotopes and the detector response of a variety of detector types. The model was validated using calibration data from a plastic and NaI(Tl) beta-gamma coincidence detector and the results are presented. The results of this validation show that this model can also be used as a tool to produce training spectra and as a method to calibrate radioxenon detection systems.

Radioxenon analysis, MCNP, beta-gamma coincidence↗

Line-shape analysis of Doppler-broadened {gamma} lines following the {beta} decay of {sup 11}Li

The {beta} decay of {sup 11}Li is studied at the TRIUMF Isotope Separation and Acceleration (ISAC) facility using the 8{pi} {gamma}-ray spectrometer coupled with an inner array of 20 plastic scintillators for {beta} detection. Doppler-broadened line shapes resulting from the decay of the excited states in {sup 10}Be populated by {beta}-delayed one-neutron emission are analyzed using Monte Carlo simulations. New {beta}-delayed neutron decay branches are shown to contribute to the complex decay of {sup 11}Li. The half-lives of all but one bound excited state in {sup 10}Be are also deduced from this work. Among them, the half-life of the 2{sup -} state in {sup 10}Be is shown to be much shorter than previously thought, yielding a new experimental B(E1) now well within the range of theoretical predictions and providing further evidence that the 2{sup -} state in {sup 10}Be is an excited halo state. The nature of the 8.82-MeV state in {sup 11}Be and its decay paths to excited states in {sup 10}Be are found to be consistent with the {beta} decay of the core proceeding through this particular state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DEPLOYING TECHNOLOGY ADVANCEMENTS FOR CHARACTERIZING THE VADOSE ZONE IN SINGLE-SHELL TANK WASTE MANAGEMENT AREAS

As much as one million gallons of waste is believed to have leaked from tanks, pipelines or other equipment in the single-shell tank farm waste management areas (WMAs) within the 200 East and West areas of the U.S. Department of Energy's Hanford Site near Richland, Washington. Although some contamination has reached groundwater, most contamination still resides in the vadose zone. The magnitude ofthis problem requires new approaches for soil characterization if we are to understand the nature and extent of the contamination and take action to protect the enviromnent. Because of the complexity and expense of drilling traditional boreholes in contaminated soil, direct push characterization using a hydraulic hammer has been extensively employed. Direct push probe holes <3-inch diameter have been pushed to a maximum depth of 240 feet below ground surface in 200 East area. Previously gross gamma and moisture logging of these narrow probe holes was perfonned to identify the location of cesium-137 ({sup 137}Cs) (which has limited mobility in Hanford soil) and moisture peaks. Recently a bismuth germinate detector has been deployed for detecting and quantifying the spectrum of cobalt-60 ({sup 60}Co) (a more mobile contaminant), which provides additional information. The direct push system is configured to allow the collection ofmultiple soil core samples throughout the depth ofthe probe hole. The direct push unit has been used to place individual electrodes at a variety of depths as the probe hole is being decommissioned. These deep electrodes enable the use of soil resistivity measurement methods between surface and deep electrodes as-well-as between sets of deep electrodes. Initial testing of surface-to-deep electrode resistivity measurements in WMA C demonstrated significant improvement in defining the three dimensional extent of a contamination plume. A multiple-electrode string is presently being developed to further enhance the resolution of resistivity data. The combined use of direct push logging/sampling and soil resistivity measurement allows more extensive characterization of the large tank farm WMAs with less cost and time commitment than required by traditional methods. An additional tool is in the laboratory testing stage to support these investigations. A beta detection tool is being evaluated to determine if it might be deployed with the direct push unit to identify technetium-99 ({sup 99}Tc) contamination. {sup 99}Tc is a mobile, long-lived contaminant that is the major risk driver from tank waste contamination. A screening tool to locate {sup 99}Tc contamination is anticipated to further increase the cost-effectiveness ofvadose zone characterization efforts.

54 ENVIRONMENTAL SCIENCES↗

Development of an alpha/beta/gamma detector for radiation monitoring

For radiation monitoring at the site of nuclear power plant accidents such as Fukushima Daiichi, radiation detectors not only for gamma photons but also for alpha and beta particles are needed because some nuclear fission products emit beta particles and gamma photons and some nuclear fuels contain plutonium that emits alpha particles. We developed a radiation detector that can simultaneously monitor alpha and beta particles and gamma photons for radiation monitoring. The detector consists of three-layered scintillators optically coupled to each other and coupled to a photomultiplier tube. The first layer, which is made of a thin plastic scintillator (decay time: 2.4 ns), detects alpha particles. The second layer, which is made of a thin Gd{sub 2}SiO{sub 5} (GSO) scintillator with 1.5 mol.% Ce (decay time: 35 ns), detects beta particles. The third layer made of a thin GSO scintillator with 0.4 mol.% Ce (decay time: 70 ns) detects gamma photons. By using pulse shape discrimination, the count rates of these layers can be separated. With individual irradiation of alpha and beta particles and gamma photons, the count rate of the first layer represented the alpha particles, the second layer represented the beta particles, and the third layer represented the gamma photons. Even with simultaneous irradiation of the alpha and beta particles and the gamma photons, these three types of radiation can be individually monitored using correction for the gamma detection efficiency of the second and third layers. Our developed alpha, beta, and gamma detector is simple and will be useful for radiation monitoring, especially at nuclear power plant accident sites or other applications where the simultaneous measurements of alpha and beta particles and gamma photons are required.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plasma Panel Based Radiation Detectors

The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels (PDPs). It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in PDPs, it uses non-reactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (< 50 m RMS) and low cost. In this paper we report here on prototype PPS experimental results in detecting betas, protons and cosmic muons, and we extrapolate on the PPS potential for applications including detection of alphas, heavy-ions at low to medium energy, thermal neutrons and X-rays.

Friedman, Dr. Peter S.↗

Simultaneous beta and gamma spectroscopy

A phoswich radiation detector for simultaneous spectroscopy of beta rays and gamma rays includes three scintillators with different decay time characteristics. Two of the three scintillators are used for beta detection and the third scintillator is used for gamma detection. A pulse induced by an interaction of radiation with the detector is digitally analyzed to classify the type of event as beta, gamma, or unknown. A pulse is classified as a beta event if the pulse originated from just the first scintillator alone or from just the first and the second scintillator. A pulse from just the third scintillator is recorded as gamma event. Other pulses are rejected as unknown events.

Farsoni, Abdollah T↗

ORBITAL CONSTRAINTS ON THE beta Pic INNER PLANET CANDIDATE WITH KECK ADAPTIVE OPTICS

A point source observed 8 AU in projection from beta Pictoris in L' (3.8 mum) imaging in 2003 has been recently presented as a planet candidate. Here we show the results of L'-band adaptive optics imaging obtained at Keck Observatory in 2008. We do not detect beta Pic b beyond a limiting radius of 0.''29, or 5.5 AU in projection, from the star. If beta Pic b is an orbiting planet, then it has moved >=0.''12 (2.4 AU in projection) closer to the star in the five years separating the two epochs of observation. We examine the range of orbital parameters consistent with the observations, including likely bounds from the locations of previously inferred planetesimal belts. We find a family of low-eccentricity orbits with semimajor axes approx8-9 AU that are completely allowed, as well as a broad region of orbits with e approx< 0.2, a approx> 10 AU that are allowed if the apparent motion of the planet was toward the star in 2003. We compare this allowed space with predictions of the planetary orbital elements from the literature. Additionally, we show how similar observations in the next several years can further constrain the space of allowed orbits. Non-detections of the source through 2013 will exclude the interpretation of the candidate as a planet orbiting between the 6.4 and 16 AU planetesimal belts.

79 ASTRONOMY AND ASTROPHYSICS↗

Orbital Constraints on the (beta) Pic Inner Planet Candidate with Keck Adaptive Optics

A point source observed 8AU in projection from {beta} Pictoris in L{prime} (3.8 {micro}m) imaging in 2003 has been recently presented as a planet candidate. Here we show the results of L{prime}-band adaptive optics imaging obtained at Keck Observatory in 2008. We do not detect {beta} Pic b beyond a limiting radius of 0.29-inch, or 5.5AU in projection, from the star. If {beta} Pic b is an orbiting planet, then it has moved {ge} 0.12-inch (2.4AU in projection) closer to the star in the five years separating the two epochs of observation. We examine the range of orbital parameters consistent with the observations, including likely bounds from the locations of previously inferred planetesimal belts. We find a family of low-eccentricity orbits with semimajor axes {approx} 8-9AU that are completely allowed, as well as a broad region of orbits with e {approx}< 0.2, a {approx}> 10AU that are allowed if the apparent motion of the planet was towards the star in 2003. We compare this allowed space with predictions of the planetary orbital elements from the literature. Additionally, we show how similar observations in the next several years can further constrain the space of allowed orbits. Non-detections of the source through 2013 will exclude the interpretation of the candidate as a planet orbiting between the 6.4 and 16AU planetesimal belts.

99 GENERAL AND MISCELLANEOUS↗

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗