Search NASA⌕ Search

SEARCH · Search NASA

Results for “BLADDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamics of liquid sloshing in upright and inverted bladdered tanks

A system identification methodology was used to examine the dynamics of liquid sloshing in the upright and inverted bladdered hydrazine tanks of the Tracking and Data Relay Satellite, (TDRS) and to evaluate the effects of bladder stiffness on the sloshing parameters. Mechanical models of the two systems were developed using the numerical values derived from static stability tests and from slosh frequency response tests of a full-size model tank fitted with a prototype bladder. For the upright tank (liquid below the bladder) a modified conventional pendulum was used. In the inverted tank (liquid above the bladder) where sloshing is unconventional due to the highly nonsymmetrical orientation of the liquid held by the bladder, a mechanical model using an inverted pendulum which is able to undergo small oscillations as well as large reorientations was necessary. Both thrusting and low-gravity conditions are considered.

Dodge, F. T.↗

A microangiographic study of the effect of hyperthermia on the rabbit bladder

A model was used to study the effect of hyperthermia on a normal tissue. The model selected was the rabbit bladder and the end point measured was the changes in the micro-vasculature of the bladder wall. It was already demonstrated clinically that hot water bladder infusions produce regression in bladder tumors.

Hietala, S. O.↗

Rapidly quantifying the relative distention of a human bladder

A device and method of rapidly quantifying the relative distention of the bladder in a human subject are disclosed. The ultrasonic transducer which is positioned on the subject in proximity to the bladder is excited by a pulser under the command of a microprocessor to launch an acoustic wave into the patient. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer, when it is received, amplified and processed by the receiver. The resulting signal is digitized by an analog-to-digital converter under the command of the microprocessor and is stored in the data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy; and based on programmed scientific measurements and individual, anatomical, and behavioral characterists of the specific subject as contained in the program memory, sends out a signal to turn on any or all of the audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.

Companion, John A.↗

Rapidly quantifying the relative distention of a human bladder

A device and method was developed to rapidly quantify the relative distention of the bladder of a human subject. An ultrasonic transducer is positioned on the human subject near the bladder. A microprocessor controlled pulser excites the transducer by sending an acoustic wave into the human subject. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer where it is received, amplified, and processed by the receiver. The resulting signal is digitized by an analog to digital converter, controlled by the microprocessor again, and is stored in data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy. Based on programmed scientific measurements and the human subject's past history as contained in program memory, the microprocessor sends out a signal to turn on any or all of the available alarms. The alarm system includes and audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.

Companion, John A.↗

Robotic Bladder Joint

Reliable, lightweight robotic joint suitable for variety of applications, actuated hydraulically, without need for heavy mechanical cylinders or gears on joint itself. Includes two members; first member rotates about pin at end of second member. Includes cam, over which tension line stretched. Ends of tension line anchored at end of second member opposite end that holds pin. Bladder placed on each side of second member, squeezed between second member and tension line. Pressures and/or amounts of fluid in bladders controlled by use of conventional equipment like pumps, valves, and reservoirs. Bladder on one side inflated more than on other side; greater inflation on one side causes greater stretching of tension line on that side. Greater tension pulls on cam, turning first member toward that side. Angle of joint controlled by controlling differential inflation of two bladders.

Robertson, Glen A.↗

Bladder Monitor

Diagnostic Ultrasound Corporation's Bladder Scan Monitor continuously records and monitors bladder fullness and alerts the wearer or caretaker when voiding is required. The sensor is held against the lower abdomen by a belt and connected to the monitor by a cable. The sensor obtains bladder volume data from sound waves reflecting off the bladder wall. The device was developed by Langley Research Center, the Ames Research Center and the NASA Technology Applications Team. It utilizes Langley's advanced ultrasound technology. It is licensed to the ARC for medical applications, and sublicensed to Diagnostics Ultrasound. Central monitoring systems are planned for the future.

Source record↗

Life prediction of expulsion bladders through fatigue test and fold strain analysis.

Consideration of the problem of reducing the probability of mechanical failure of bladder systems used for the expulsion of propellants into liquid rocket engines. It is shown that individual local folds in collapsing bladders can be classified into single and double folds, specifiable by nondimensional geometrical parameters which directly define the maximum strains at these folds. From these maximum strains the number of collapse/inflation cycles to failure can be obtained from low-cycle fatigue data experimentally determined for the bladder material of interest. Cycle life data are presented in terms of true maximum strain for four metals, two plastics, and two elastomers. It is found that double folds give rise to much more severe folding strains than do simple folds.

Chu, H. N.↗

Ultrasonic Device Monitors Fullness Of The Bladder

Ultrasonic device monitors fullness of bladder is self-contained, lightweight, portable, powered by battery, and tailored for specific patient through software modified as patient's behavior changes. Essentially quantifies amount of urine in bladder by measuring relative distension of bladder and gives suitable alarm telling patient to eliminate. Intended for use in training people who are incontinent and cannot identify when elimination necessary.

Heyman, Joseph S.↗

Bladder operated robotic joint

This invention is a robotic joint which is operated by inflatable bladders and which can be used in applications where it is desired to move or hold an object. A support block supports an elongated plate to which is pivotally attached a finger. A tension strip passes over a lever attached to the finger and is attached at its ends to the support block on opposite sides of the plate. Bladders positioned between the plate and the tension strip on opposite sides of the plate can be inflated by pumps to pivot the finger, with one of the bladders being inflated while the other is being deflated.

Robertson, Glen A.↗

Polymeric Bladder for Storing Liquid Oxygen

A proposed system for storing oxygen in liquid form and dispensing it in gaseous form is based on (1) initial subcooling of the liquid oxygen; (2) containing the liquid oxygen in a flexible vessel; (3) applying a gas spring to the flexible vessel to keep the oxygen compressed above the saturation pressure and, thus, in the liquid state; and (4) using heat leakage into the system for vaporizing the oxygen to be dispensed. In a typical prior system based on these principles, the flexible vessel is a metal bellows housed in a rigid tank, and the gas spring consists of pressurized helium in the tank volume surrounding the bellows. Unfortunately, the welds in the bellows corrugations are subject to fatigue, and, because bellows have large ullage, a correspondingly large fraction of the oxygen content cannot be expelled. In the proposed system, the flexible vessel would be a bladder made of a liquid- crystal polymer (LCP). (LCPs are strong and compatible with liquid oxygen.) In comparison with a metal bellows, a polymeric bladder would have less ullage and would weigh less. In experiments involving fatigue cycling at liquid-nitrogen temperatures, two LCPs were found to be suitable for this application.

Walker, David H.↗

Testing of Alternative Materials for Advanced Suit Bladders

Several candidate advanced pressure bladder membrane materials have been developed for NASA Johnson Space Center by DSM Biomedical for selective permeability of carbon dioxide and water vapor. These materials were elasthane and two other formulations of thermoplastic polyether polyurethane. Each material was tested in two thicknesses for permeability to carbon dioxide, oxygen and water vapor. Although oxygen leaks through the suit bladder would amount to only about 60 cc/hr in a full size suit, significant amounts of carbon dioxide would not be rejected by the system to justify its use. While the ratio of carbon dioxide to oxygen permeability is about 48 to 1, this is offset by the small partial pressure of carbon dioxide in acceptable breathing atmospheres of the suit. Humidity management remains a possible use of the membranes depending on the degree to which the water permeability is inhibited by cations in the sweat. Tests are underway to explore cation fouling from sweat.

Bue, Grant↗