Production Facility Prototype Blower 1000 Hour Test Results V

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Thirteen long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All thirteen long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the thirteenth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, III, and IV.

36 MATERIALS SCIENCE↗

Energy efficiency of blower heater non-purge compressed air dryers

This research focuses on twin tower regenerative closed loop desiccant dryers, specifically: blower heater non-purge (BHNP) with and without cooling water pumps, compressed-air heater purge (CHP), blower heater purge (BHP) and pressure swing heaterless (PSH). The research was conducted by collecting and analysing real time current draw data on air compressors and associated dryers at eight different facilities (13 air compressors) in terms of energy, power and cost. A decision tool was developed to depict the operational characteristics (power, energy and cost) of each type of dryer if used in conjunction with the selected compressor system. Finally, this research, on an equivalent normalised basis, compared and contrasted the different types of dryers in terms of performance and cost. Here, the research concluded that of the five types of desiccant dryer types observed the most energy efficient was the BHNP (with cooling water pump), subject to the operational conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEVELOPMENT OF OIL FREE CENTRIFUGAL BLOWER AS ENABLING TECHNOLOGY FOR SOLID OXIDE FUEL CELL ANODE GAS RECYCLING

Broad commercialization of solid oxide fuel cells (SOFCs), requires anode offgas recycle blowers (AORB) that are specifically designed for handling the challenging operating conditions presented by the SOFC process gases. Otherwise, they can be susceptible to frequent maintenance, low reliability, and short life. This work presents details of the development and testing of an oil-free, low cost centrifugal AORB based on compliant foil bearing (CFB) technology for support of a 100 kW solid oxide fuel cell power plant. The advantages of this novel technology are discussed, particularly its long life and maintenance-free operation, which are derived from the use of CFBs. Also included are preliminary techno-economic analysis considerations for cost-effective deployment of the technology.

03 NATURAL GAS↗

High Temperature Anode Recycle Blower for Solid Oxide Fuel Cell, Phase II (Final Report)

Broad commercialization of solid oxide fuel cells (SOFCs) requires anode offgas recycle blowers (ARCB) that are specifically designed for handling the challenging operating conditions presented by the SOFC process gases. Otherwise, they can be susceptible to frequent maintenance, low reliability, and short life. This report presents details of a DOE-funded Phase II effort conducted by Mohawk Innovative Technology, Inc. (MiTi®) for the development and testing of an oil-free, low cost, high-temperature centrifugal ARCB based on compliant foil bearing (CFB) technology for support of a 100 kW solid oxide fuel cell power plant. This Phase II builds on the results of a successful Phase I development project that resulted in the demonstration of a low TRL-6 prototype, shown in Figure 1. This Phase II final report presents design improvements over the Phase I prototype, presents the assembled test ARCBs, and discusses the advantages of this novel technology, particularly its long life and maintenance-free operation, which are derived from the use of CFBs. Also included are preliminary techno-economic analysis considerations for cost-effective deployment of the technology. The specific objectives of this project, as stated in the statement of program objectives (SOPO) were 1) to follow the methodology of design for manufacturing (or manufacturability) and assembly for implementing improvements identified as part of the Phase I effort with the purpose of reducing cost, enabling mass production, and facilitating the commercialization of a revised ARCB design, and 2) to fabricate four complete ARCB units based on the revised design and demonstrating their performance in both a laboratory setting and in an actual SOFC power plant. Execution of this SOPO would be supported by a number of technical tasks resulting in the fabrication and testing of the prototypes. To this end, MiTi continued the teaming relationship started during Phase I of the program with subcontracting partner FuelCell Energy, Inc. (FCE), which integrated (under a parallel effort funded by DOE Award DE-FE0026199) a modular 200 kWe SOFC power plant. MiTi and FCE coordinated to ultimately incorporate one of MiTi’s ARCB prototypes into one of the 100 kWe SOFC Modular Power Blocks (MPB) that constitute the core of FCE’s SOFC power plant for in-situ long-duration testing. Additionally, MiTi would explore the scalability and extendibility of the technology to other applications, as well as conduct a basic techno-economic analysis.

03 NATURAL GAS↗

The Effect of Air Separations on Fast Pyrolysis Products for Forest Residue Feedstocks

This study investigates the intricate relationship between biomass preprocessing and pyrolysis product yields, employing the air classification technique for the treatment of loblolly pine residues with varying moisture content. A comprehensive exploration of the physicochemical properties of air-classified loblolly pine informs a sophisticated pyrolysis simulation model. Given the complex and multifaceted nature of biomass pyrolysis, operating across diverse temporal and spatial scales, a pyrolysis kinetics-based CFD–DEM simulation method is employed to predict product yields. Results showed that the elevated moisture content amplifies particle adhesiveness, necessitating augmented air velocities for effective separation, thereby influencing the efficiency of the separation process. While carbon and hydrogen contents exhibit relative stability across diverse moisture contents and blower frequencies, the oxygen content undergoes noticeable changes. For example, the oxygen contents were measured as 29.2 and 38.6 wt% in the light fraction of 30% moisture content sample at blower frequencies of 10 and 20 Hz, respectively. An intriguing finding emerges from pyrolysis simulation, indicating that a lower blower frequency in air classification moderately enhances bio-oil yield and significantly improves its quality, particularly in terms of water content. For instance, the water content in the bio-oil was about 1.5% and 10% in the heavy and light fractions, respectively from 10% moisture sample under 15 Hz blower frequency. In summary, a detailed understanding and strategic manipulation of critical material attributes in biomass through efficient fractionation techniques are imperative for advancing fast pyrolysis as a sustainable avenue for renewable energy and chemical production.

09 BIOMASS FUELS↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Classification of Forestry Residues for Fast Pyrolysis

Understanding critical biomass attributes through efficient fractionation is crucial for advancing sustainable pyrolysis for renewable energy and chemical production. This study investigates the intricate relationship between biomass preprocessing and pyrolysis product yields, employing the air classification technique for the treatment of loblolly pine residues with varying moisture content. A comprehensive exploration of the physicochemical properties of air-classified loblolly pine informs a sophisticated pyrolysis simulation model. Given the complex and multifaceted nature of biomass pyrolysis, operating across diverse temporal and spatial scales, a pyrolysis kinetics-based CFD–DEM simulation method is employed to predict product yields. Results showed that the elevated moisture content amplifies particle adhesiveness, necessitating augmented air velocities for effective separation, thereby influencing the efficiency of the separation process. While carbon and hydrogen contents exhibit relative stability across diverse moisture contents and blower frequencies, the oxygen content undergoes noticeable changes. For example, the oxygen contents were measured as 29.2 and 38.6 wt% in the light fraction of 30% moisture content sample at blower frequencies of 10 and 20 Hz, respectively. An intriguing finding emerges from pyrolysis simulation, indicating that a lower blower frequency in air classification moderately enhances bio-oil yield and significantly improves its quality, particularly in terms of water content. For instance, the water content in the bio-oil was about 1.5% and 10% in the heavy and light fractions, respectively from 10% moisture sample under 15 Hz blower frequency.

09 - BIOMASS FUELS↗

Experimental Plan for the Vermiculite Study

Homes in which vermiculite, which can contain asbestos, is present are often deferred under the DOE Weatherization Assistance Program (WAP) because of uncertainty in how to safely weatherize such homes from a client and worker perspective and the potential costs associated with alternative approaches. Recognizing this situation, the Department of Energy (DOE) tasked the Oak Ridge National Laboratory (ORNL) to perform a research project that scientifically identifies the asbestos exposure risks in weatherizing homes with existing vermiculite insulation. Current approaches being used by Grantees and Subgrantees to weatherize homes with existing vermiculite insulation were identified as part of the development of this experimental plan based on a review of Grantee Health and Safety Plans and communications with weatherization program staff from seven states. Other than deferral, these approaches include the following:1.) Abating (i.e., removing) the existing vermiculite using funding sources other than WAP (e.g., state funds, utility funds, the Zonolite Attic Insulation Trust Fund, and possibly homeowner contributions) because abatement is not allowed using WAP funds per Weatherization Program Notice (WPN) 17-7. 2.) Weatherizing the house as normal after testing reveals that the vermiculite contains less than 1% asbestos. 3.) Avoiding areas of the house where vermiculite is installed and weatherizing the remaining areas of the house as normal. 4.) Encapsulating the existing vermiculite insulation in an attic by blowing cellulose or other insulation over it. 5.) Weatherizing the areas of the house where vermiculite is installed using unique/alternative approaches developed specifically for that house. Blower door testing is also impacted by the presence of vermiculite due to the concern of bringing asbestos fibers into the space. Some states address this by performing pressurized blower door tests, whereas other states prohibit blower door testing entirely when vermiculite is present. This research project will focus on gathering data on home occupant and weatherization worker exposures to asbestos before, during, and/or after the weatherization of the homes containing vermiculite insulation using five of the six approaches identified above. Abatement of the existing vermiculite insulation will not be studied because it is not allowed using WAP funding per WPN 17-7 and, thus, is not a sustainable approach for WAP.

36 MATERIALS SCIENCE↗

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Development and experimental evaluation of new building air leakage measurement methods: measurement of interior air leaks and comparison to conventional methods

Building air leaks (both through exterior and interior surfaces) can have a significant impact on energy consumption, indoor air quality, fire safety, and moisture accumulation affecting structural durability. Blower door testing has been used to measure leaks in buildings, but commonly used testing methods do not directly measure interior leaks. In this paper, new testing methods (guarded interior test and zonal multipoint pressure testing method) are presented that directly measure these interior leaks, utilizing common blower door equipment for both single and multi-point testing. Furthermore, these new methods are compared to conventional methods in terms of the information provided, limitations and time/effort needed. In addition, building leak measurement results are analyzed to reveal a) coupling between power law model values (exponent and coefficient) for an ensemble of buildings, b) the error in using single point testing when estimating low pressure leakage, and c) how building power law models vary from low to high pressure ranges.

99 GENERAL AND MISCELLANEOUS↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Air Sealing Demonstration: Denver Federal Center Building 40

This project aimed to demonstrate building airtightness achieved by automated air sealing in a commercial building setting. The automated air sealing demonstrated in this project uses a modified blower door to pressurize and distribute the sealing aerosol to achieve the required building airtightness. To demonstrate this technology, Building 40 at the Denver Federal Center, a federally owned campus under the jurisdiction, custody and control of the U.S. General Services Administration (GSA), was selected for testing (Figure 2). This building is currently undergoing several retrofit projects, including increasing insulation, installing high-performance windows, and adding advanced equipment, control systems, and automated air sealing. This demonstration project involved installing automated air sealing and measuring the improvements in the building's airtightness. The automated air sealing was installed over two days by AeroBarrier, the vendor. An external blower door test contractor measured the airtightness of the demonstration space before and after air sealing. The new airtightness value and the percentage increase in airtightness were used to evaluate the energy savings potential of automated air sealing. These airtightness values were used to compute the energy savings and CO 2 emissions reduction for different climate zones, building types, and initial airtightness conditions. In addition, the heating, ventilation and air conditioning (HVAC) load reduction attributable to the reduced building air leakage was studied. This study included research to determine the cost and time reduction of automated air sealing. Finally, the automated air sealing performance was evaluated qualitatively using a focus group discussion that included GSA and Bristol, the general contractor. The installation has shown the demonstration site, with a floor size of 4,462 ft 2 , air leakage has reduced by more than 50% in less than 7 hours, including preparation, site sealing, and cleanup. The performance objectives were classified as quantitative or qualitative based on the evaluation metrics used to assess the project’s success. The key performance objectives for this project were the level of airtightness achieved, the time and cost required to perform the sealing, and the HVAC load reduction attributable to air sealing. Table 1 shows the quantitative performance objectives.

42 ENGINEERING↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗