Search NASA⌕ Search

SEARCH · Search NASA

Results for “BPM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ultraviolet carbon lines in the spectrum of the white dwarf BPM 11668

The southern hemisphere DC white dwarf BPM 11668 has been found to show strong ultraviolet lines of neutral carbon using observations from the IUE satellite. This star seems typical of the growing number of DC white dwarfs found to be of this type and appears to have a carbon abundance near C:He = 0.0001, with an effective temperature of 8500 K.

Wegner, G.↗

Operationally Efficient Propulsion System Study (OEPSS) Data Book: Integrated Booster Propulsion Module (BPM) Engine Start Dynamics - Volume 8

A fluid-dynamic, digital-transient computer model of an integrated, parallel propulsion system was developed for the CDC mainframe and the SUN workstation computers. Since all STME component designs were used for the integrated system, computer subroutines were written characterizing the performance and geometry of all the components used in the system, including the manifolds. Three transient analysis reports were completed. The first report evaluated the feasibility of integrated engine systems in regards to the start and cutoff transient behavior. The second report evaluated turbopump out and combined thrust chamber/turbopump out conditions. The third report presented sensitivity study results in staggered gas generator spin start and in pump performance characteristics.

Kemp, Victoria R.↗

Operationally efficient propulsion system study (OEPSS) data book: Preliminary Development Plan for an Integrated Booster Propulsion Module (BPM) - Volume 9

A preliminary development plan for an integrated propulsion module (IPM) is described. The IPM, similar to the Space Transportation Main engine (STME) engine, is applicable to the Advanced Launch System (ALS) baseline vehicle. The same STME development program ground rules and time schedule were assumed for the IPM. However, the unique advantages of testing an integrated engine element, in terms of reduced number of hardware and number of system and reliability tests, compared to single standalone engine and MPTA, are highlighted. The potential ability of the IPM to meet the ALS program goals for robustness, operability and reliability is emphasized.

DiBlasi, Angelo G.↗

Pilot Field Test: Use of a Compression Garment During a Stand Test After Long-Duration Space Flight

Orthostatic intolerance (OI) is a concern for astronauts returning from long-duration space flight. One countermeasure that has been used to protect against OI after short-duration bed rest and space flight is the use of lower body and abdominal compression garments. However, since the end of the Space Shuttle era we have not been able to test crewmembers during the first 24 hours after landing on Earth. NASA's Pilot Field Test provided us the opportunity to test cardiovascular responses of crewmembers wearing the Russian Kentavr compression garment during a stand test at multiple time points throughout the first 24 hours after landing. HYPOTHESIS We hypothesized that the Kentavr compression garment would prevent an increase in heart rate (HR) >15 bpm during a 3.5-min stand test. METHODS: The Pilot Field Test was conducted up to 3 times during the first 24 hours after crewmembers returned to Earth: (1) either in a tent adjacent to the Soyuz landing site in Kazakhstan (approx.1 hr) or after transportation to the Karaganda airport (approx. 4 hr); (2) during a refueling stop in Scotland (approx.12 hr); and (3) upon return to NASA Johnson Space Center (JSC) (approx.24 hr). We measured HR and arterial pressure (finger photoplethysmography) for 2 min while the crewmember was prone and throughout 3.5 min of quiet standing. Eleven crewmembers consented to participate; however, 2 felt too ill to start the test and 1 stopped 30 sec into the stand portion of the test. Of the remaining 8 crewmembers, 2 did not wear the Russian Kentavr compression garment. Because of inclement weather at the landing site, 5 crewmembers were flown by helicopter to the Karaganda airport before initial testing and received intravenous saline before completing the stand test. One of these crewmembers wore only the portion of the Russian Kentavr compression garment that covered the lower leg and thus lacked thigh and abdominal compression. All crewmembers continued wearing the Russian Kentavr compression garment during the second testing session in Scotland, but none wore it during testing at JSC. RESULTS: The mean Delta HR from the supine to standing position in the 8 crewmembers measured pre-flight or 60 days after return from long-duration space flight was 9.8 bpm. During the first few hours after landing from long-duration space flight, the mean Delta HR of the 6 crewmembers who wore the Russian Kentavr compression garment in Kazakhstan or Karaganda was +14 bpm and the change in mean arterial pressure (Delta MAP) was +0.8 mmHg, while the 2 crewmembers who did not wear the Russian Kentavr compression garment had a Delta HR of +38 bpm and a Delta MAP of +1.1 mmHg. In Scotland, 4 crewmembers wore the Russian Kentavr compression garment and had a Delta HR of +7.4 bpm while the 3 crewmembers who did not wear it had a Delta HR of +25.0 bpm. Seven crewmembers were tested upon return to JSC approx. 24 hr after landing, but none wore the Russian Kentavr compression garment and their Delta HR was 16.0 bpm. CONCLUSIONS: These are the first stand-test data to be collected from long-duration crewmembers during the first 24 hr of re-adaptation to gravity on Earth. The Delta HR measured in crewmembers who completed the stand-test while wearing Kentavr within the first approx.4 hours after returning to Earth was only slightly elevated from pre-flight Delta HR, while the few subjects who did not wear the Russian Kentavr compression garment had a much larger increase in HR in order to maintain arterial pressure throughout 3.5-min of standing. These data demonstrate the effectiveness of a compression garment in preventing large increases in HR during a 3.5 min stand test after long-duration space flight. However, the fact that three crewmembers were too ill to complete the test or was not able to complete 3.5 min of standing despite wearing the Russian Kentavr compression garment indicates that wearing a compression garment does not resolve all problems crewmembers face during the period of re-adaptation immediately after return to Earth's gravity.

Laurie, S. S.↗

Sympathetic activation in exercise is not dependent on muscle acidosis. Direct evidence from studies in metabolic myopathies

Muscle acidosis has been implicated as a major determinant of reflex sympathetic activation during exercise. To test this hypothesis we studied sympathetic exercise responses in metabolic myopathies in which muscle acidosis is impaired or augmented during exercise. As an index of reflex sympathetic activation to muscle, microneurographic measurements of muscle sympathetic nerve activity (MSNA) were obtained from the peroneal nerve. MSNA was measured during static handgrip exercise at 30% of maximal voluntary contraction force to exhaustion in patients in whom exercise-induced muscle acidosis is absent (seven myophosphorylase deficient patients; MD [McArdle's disease], and one patient with muscle phosphofructokinase deficiency [PFKD]), augmented (one patient with mitochondrial myopathy [MM]), or normal (five healthy controls). Muscle pH was monitored by 31P-magnetic resonance spectroscopy during handgrip exercise in the five control subjects, four MD patients, and the MM and PFKD patients. With handgrip to exhaustion, the increase in MSNA over baseline (bursts per minute [bpm] and total activity [%]) was not impaired in patients with MD (17+/-2 bpm, 124+/-42%) or PFKD (65 bpm, 307%), and was not enhanced in the MM patient (24 bpm, 131%) compared with controls (17+/-4 bpm, 115+/-17%). Post-handgrip ischemia studied in one McArdle patient, caused sustained elevation of MSNA above basal suggesting a chemoreflex activation of MSNA. Handgrip exercise elicited an enhanced drop in muscle pH of 0.51 U in the MM patient compared with the decrease in controls of 0.13+/-0.02 U. In contrast, muscle pH increased with exercise in MD by 0.12+/-0.05 U and in PFKD by 0.01 U. In conclusion, patients with glycogenolytic, glycolytic, and oxidative phosphorylation defects show normal muscle sympathetic nerve responses to static exercise. These findings indicate that muscle acidosis is not a prerequisite for sympathetic activation in exercise.

NASA Discipline Cardiopulmonary↗

CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW)

This software provides essential startup and initialization routines for the CoNNeCT baseband processor module (BPM) hardware upon power-up. A command and data handling (C&DH) interface is provided via 1553 and diagnostic serial interfaces to invoke operational, reconfiguration, and test commands within the code. The BCSW has features unique to the hardware it is responsible for managing. In this case, the CoNNeCT BPM is configured with an updated CPU (Atmel AT697 SPARC processor) and a unique set of memory and I/O peripherals that require customized software to operate. These features include configuration of new AT697 registers, interfacing to a new HouseKeeper with a flash controller interface, a new dual Xilinx configuration/scrub interface, and an updated 1553 remote terminal (RT) core. The BCSW is intended to provide a "safe" mode for the BPM when initially powered on or when an unexpected trap occurs, causing the processor to reset. The BCSW allows the 1553 bus controller in the spacecraft or payload controller to operate the BPM over 1553 to upload code; upload Xilinx bit files; perform rudimentary tests; read, write, and copy the non-volatile flash memory; and configure the Xilinx interface. Commands also exist over 1553 to cause the CPU to jump or call a specified address to begin execution of user-supplied code. This may be in the form of a real-time operating system, test routine, or specific application code to run on the BPM.

Yamamoto, Clifford K.↗

Raised cerebrovascular resistance in idiopathic orthostatic intolerance: evidence for sympathetic vasoconstriction

Patients with idiopathic orthostatic intolerance (IOI) exhibit symptoms suggestive of cerebral hypoperfusion and an excessive decrease in cerebral blood flow associated with standing despite sustained systemic blood pressure. In 9 patients (8 women and 1 man aged 22 to 48 years) with IOI, we tested the hypothesis that volume loading (2000 cc normal saline) and alpha-adrenoreceptor agonism improve systemic hemodynamics and cerebral perfusion and that the decrease in cerebral blood flow with head-up tilt (HUT) could be attenuated by alpha-adrenoreceptor blockade with phentolamine. At 5 minutes of HUT, volume loading (-20+/-3.2 bpm) and phenylephrine (-18+/-3.4 bpm) significantly reduced upright heart rate compared with placebo; the effect was diminished at the end of HUT. Phentolamine substantially increased upright heart rate at 5 minutes (20+/-3.7 bpm) and at the end of HUT (14+/-5 bpm). With placebo, mean cerebral blood flow velocity decreased by 33+/-6% at the end of HUT. This decrease in cerebral blood flow with HUT was attenuated by all 3 interventions. We conclude that in patients with IOI, HUT causes a substantial decrease in cerebrovascular blood flow velocity. The decrease in blood flow velocity with HUT can be attenuated with interventions that improve systemic hemodynamics and therefore decrease reflex sympathetic activation. Moreover, alpha-adrenoreceptor blockade also blunts the decrease in cerebral blood flow with HUT but at the price of deteriorated systemic hemodynamics. These observations may suggest that in patients with IOI, excessive sympathetic activity contributes to the paradoxical decrease in cerebral blood flow with upright posture.

Non-NASA Center↗

A diminished aortic-cardiac reflex during hypotension in aerobically fit young men

We compared the aortic-cardiac baroreflex sensitivity in eight average fit (AF: VO2max = 44.7 +/- 1.3 ml.kg-1 x min-1) and seven high fit (HF: VO2max = 64.1 +/- 1.7 ml.min-1 x kg-1) healthy young men during hypotension elicited by steady state sodium nitroprusside (SN) infusion. During SN mean arterial pressure (MAP) was similarly decreased in AF (-12.6 +/- 1.0 mm Hg) and HF (-12.1 +/- 1.1 mm Hg). However, the increases in heart rate (HR) were less (P < 0.023) in HF (15 +/- 3 bpm) than AF (25 +/- 1 bpm). When sustained neck suction (NS, -22 +/- 1 torr in AF and -20 +/- 1 torr in HF, P > 0.05) was applied to counteract the decreased carotid sinus transmural pressure during SN, thereby isolating the aortic baroreceptors, the increased HR remained less (P < 0.021) in HF (8 +/- 2 bpm) than AF (16 +/- 2 bpm). During both SN infusion and SN+NS, the calculated gains (i.e., delta HR/delta MAP) were significantly greater in AF (2.1 +/- 0.3 and 1.3 +/- 0.2 bpm.mm Hg-1) than HF (1.2 +/- 0.2 and 0.6 +/- 0.2 bpm.mm Hg-1). However, the estimated carotid-cardiac baroreflex sensitivity (i.e., the gain difference between the stage SN and SN + NS) was not different between AF (0.7 +/- 0.2 bpm.mm Hg-1) and HF (0.6 +/- 0.1 bpm.mm Hg-1). These data indicated that the aortic-cardiac baroreflex sensitivity during hypotension was significantly diminished with endurance exercise training.

NASA Discipline Number 14-10↗

WISE-2005: Integrative Cardiovascular Responses with LBNP during 60-Day Bed Rest in Women

During 2005, 24 women will take part in the Women International Space-simulation for Exploration (WISE). In this paper we report on the first phase that studied 4 Exercise (EX+LBNP), 4 nutrition (NUT), and 4 no countermeasure control (CON) subjects. The EX+LBNP group completed regular exercise on a treadmill inside LBNP, flywheel resistive exercise and static periods of LBNP, and had recovery days. The NUT group received daily protein supplements. Integrative cardiovascular responses were obtained and here we report data for heart rate during LBNP, blood volume and angiotensin 11. LBNP was applied at 0, -10, -20 and -30 mmHg for 2-minutes for each stage. Blood was sampled prebed rest and on HDT-60. After 60-days head down bed rest, HR in the CON group increased by 6.1+/-2.8 bpm at rest and by 20.7+/-5.0 bpm at -30 mmHg LBNP. The EX+LBNP group had increases of 3.6+/-5.6 and 11.6+/-5.4 bpm, while the NUT group HR increased 2.6+/-3.1 and 9.4+/-3.6 bpm. The EX+LBNP group had almost no change in blood volume or plasma angiotensin II from pre-bed rest to HDT60, while both the CON and NUT groups had larger increases in plasma volume and almost double concentrations of angiotensin II. These data show a positive effect in the EX+LBNP group on the heart rate response as well as an unexpected possible benefit in the NUT group. Further studies are required to confirm possible cardiovascular benefits of the protein supplement.

Hughson, R. L.↗

Hypovolemia Induced Orthostatic Hypotension in Presyncopal Astronauts and Normal Subjects Relates to Hypo-Sympathetic Responsiveness

Circulating blood volume is reduced during spaceflight, leaving astronauts hemodynamically compromised after landing. Because of this hypovolemia, crew members are able to withstand a postflight 10 minute upright tilt test only if they are able to mount a hyper-sympathetic response. Previous work from this laboratory has shown that about 30% of astronauts, primarily female, have postflight sympathetic responses to tilt that are equal to or less than their preflight responses and thus, they become presyncopal. Part of the mission of the cardiovascular lab at the Johnson Space Center is to identify susceptible crewmembers before flight so that individualized countermeasures can be prescribed. The goal of this study was to develop a ground based model of hypovolemia that could be used for this purpose We tested the hypothesis that hypovolemia alone, in the absence of spaceflight, would reproduce the landing day rate of presyncope during upright tilt in normal volunteers. Further, we hypothesized that, during hypovolemia, subjects who had sympathetic responses that were equal to or less than their normovolemic responses would become presyncopal during upright tilt tests. We studied 20 subjects, 13 male and 7 female, on two separate occasions: during normovolemia and hypovolemia. We induced hypovolemia with intravenous furosemide 40 hours prior to the experiment day, followed by a 10MEq Na diet. On the normovolemia and hypovolemia test days, plasma volume, tilt tolerance and supine and standing arterial pressure, heart rate and plasma norepinephrine levels were measured. A two factor, repeated measures analysis of variance was performed to examine the differences between group (presyncopal vs. non-presyncopal) and day (normovolemia vs. hypovolemia) effects. There were no differences in baseline arterial pressure between normovolemia and hypovolemia or between presyncopal and non-presyncopal groups, but heart rates were higher with hypovolemia in both groups (presyncopal: 70 5 bpm vs. 63 3 bpm, P = 0.003, non-presyncopal: 59 2 bpm vs. 52 2 bpm, P = 0.003). Similar to patterns reported after flight, non-presyncopal subjects had greater norepinephrine responses to tilt during hypovolemia compared to normovolemia (580 79 vs. 298 37 pg/ml, P < 0.05), but presyncopal subjects did not (180 44 vs. 145 32 pg/ml, P = NS). This new model has the potential to accelerate the development of countermeasures and save flight resources. It can be used to identify astronauts who will become presyncopal on landing day, so that prospective, individualized countermeasures can be developed. In addition, it can also be used to screen candidate countermeasures prior to requests for bed rest or inflight resources.

Meck, Janice V.↗

Broadband Predictions of Optimized Proprotors in Axial Forward Flight

A low-fidelity toolchain was used to predict broadband self-noise trends for three proprotors in axial flight: a baseline (C24ND) and two acoustically constrained proprotors (OPT-III and COPR-3). Rotor loads were predicted with the ANOPP Propeller Analysis System (PAS) and self-noise was predicted with the semiempirical method of Brooks, Pope, and Marcolini (BPM) implemented in the ANOPP2 Self-Noise Internal Functional Module (ASNIFM). Comparisons to experimental data revealed that trends for turbulent boundary layer trailing edge (TBL-TE) noise could be modeled across several flight conditions by increasing the boundary layer thicknesses via the trip setting. Since the Mach number range of the BPM method is exceeded in these predictions, a dependence of boundary layer displacement thickness on blade station Mach number was suggested as a possible reason for needing to model thicker boundary layers, suggesting that the TBL-TE model needs to be developed further. Bluntness vortex shedding noise (BVS) predictions required tuning the trailing edge thickness and trailing edge closure angle for each flight condition to match experimental trends, demonstrating that the BVS noise model is incomplete and that BVS noise may vary with the angle of attack. This study indicates that the BPM self-noise method needs to be improved, which will lead to more accurate broadband predictions.

Broadband self-noise↗

Broadband Predictions of Optimized Proprotors in Axial Forward Flight

A low-fidelity toolchain was used to predict broadband self-noise trends for three proprotors in axial flight: a baseline (C24ND) and two acoustically constrained proprotors (OPT-III and COPR-3). Rotor loads were predicted with the ANOPP Propeller Analysis System (PAS) and self-noise was predicted with the semiempirical method of Brooks, Pope, and Marcolini (BPM) implemented in the ANOPP2 Self-Noise Internal Functional Module (ASNIFM). Comparisons to experimental data revealed that trends for turbulent boundary layer trailing edge (TBL-TE) noise could be modeled across several flight conditions by increasing the boundary layer thicknesses via the trip setting. Since the Mach number range of the BPM method is exceeded in these predictions, a dependence of boundary layer displacement thickness on blade station Mach number was suggested as a possible reason for needing to model thicker boundary layers, suggesting that the TBL-TE model needs to be developed further. Bluntness vortex shedding noise (BVS) predictions required tuning the trailing edge thickness and trailing edge closure angle for each flight condition to match experimental trends, demonstrating that the BVS noise model is incomplete and that BVS noise may vary with the angle of attack. This study indicates that the BPM self-noise method needs to be improved, which will lead to more accurate broadband predictions.

Broadband self-noise↗

Fundamentals of Mold Free Casting: Experimental and Computational Studies

Researchers are developing the technology of 'Ballistic Particle Manufacturing' (BPM) in which individual drops are precisely layered onto a substrate, and the drops are deposited so as to prevent splatting. These individual drops will ultimately be combined to form a net-shape, three-dimensional object. Our understanding of controlled drop deposition as applied to BPM is far from complete. Process parameters include the size and temperature of the liquid metal drop, its impact velocity and trajectory, and the condition and temperature of the substrate. Quantitative knowledge of the fluid mechanics and heat transfer of drop deposition and solidification are necessary to fully optimize the manufacturing process and to control the material microstructure of the final part. The object of this study is to examine the dynamics of liquid metal drops as they impinge upon a solid surface and solidify under conditions consistent with BPM (i.e. conditions which produce non-splatting drops). A program of both numerical simulations and experiments will be conducted. Questions this study will address include the following: How do the deformation and solidification of the drop depend on the properties of the fluid drop and the solid substrate? How does the presence of previously deposited drops affect the impingement and solidification process? How does the impingement of the new drop affect already deposited material? How does the cooling rate and solidification of the drops influence the material microstructure?

Tryggvason, Gretar↗

Effect of In-Flight Exercise and Extravehicular Activity on Postflight Stand Tests

The purpose of this study was to determine whether exercise performed by Space Shuttle crewmembers during short-duration spaceflights (9-16 days) affects the heart rate (HR) and blood pressure (BP) responses to standing within 2-4 hr of landing. Thirty crewmembers performed self-selected in-flight exercise and maintained exercise logs to monitor their exercise intensity and duration. A 10min stand test, preceded by at least 6 min of quiet supine rest, was completed 10- 15 d before launch (PRE) and within four hours of landing (POST). Based upon their in-flight exercise records, subjects were grouped as either high (HIex: = 3x/week, HR = 70% ,HRMax, = 20 min/session, n = 11), medium (MEDex: = 3x/week, HR = 70% HRmax, = 20 min/session, n = 10), or low (LOex: = 3x/week, HR and duration variable, n = 11) exercisers. HR and BP responses to standing were compared between groups (ANOVA, or analysis of variance, P < 0.05). There were no PRE differences between the groups in supine or standing HR and BP. Although POST supine HR was similar to PRE, all groups had an increased standing HR compared to PRE. The increase in HR upon standing was significantly greater after flight in the LOex group (36+/-5 bpm) compared to HIex or MEDex groups (25+/-1bpm; 22+/-2 bpm). Similarly, the decrease in pulse pressure (PP) from supine to standing was unchanged after spaceflight in the MEDex and HIex groups, but was significantly less in the LOex group (PRE: -9+/- 3, POST: -19+/- 4 mmHg). Thus, moderate to high levels of in-flight exercise attenuated HR and PP responses to standing after spaceflight compared.

Lee, Stuart M. C.↗

Effects of repeated Valsalva maneuver straining on cardiac and vasoconstrictive baroreflex responses

INTRODUCTION: We hypothesized that repeated respiratory straining maneuvers (repeated SM) designed to elevate arterial BPs (arterial baroreceptor loading) would acutely increase baroreflex responses. METHODS: We tested this hypothesis by measuring cardiac baroreflex responses to carotid baroreceptor stimulation (neck pressures), and changes in heart rate and diastolic BP after reductions in BP induced by a 15-s Valsalva maneuver in 10 female and 10 male subjects at 1, 3, 6, and 24 h after performing repeated SM. Baroreflex responses were also measured in each subject at 1, 3, 6, and 24 h at the same time on a separate day without repeated SM (control) in a randomized, counter-balanced cross-over experimental design. RESULTS: There was no statistical difference in carotid-cardiac and peripheral vascular baroreflex responses measured across time following repeated SM compared with the control condition. Integrated cardiac baroreflex response (deltaHR/ deltaSBP) measured during performance of a Valsalva maneuver was increased by approximately 50% to 1.1 +/- 0.2 bpm x mm Hg(-1) at 1 h and 1.0 +/- 0.1 bpm x mm Hg(-1) at 3 h following repeated SM compared with the control condition (0.7 +/- 0.1 bpm x mm Hg(-1) at both 1 and 3 h, respectively). However, integrated cardiac baroreflex response after repeated SM returned to control levels at 6 and 24 h after training. These responses did not differ between men and women. CONCLUSIONS: Our results are consistent with the notion that arterial baroreceptor loading induced by repeated SM increased aortic, but not carotid, cardiac baroreflex responses for as long as 3 h after repeated SM. We conclude that repeated SM increases cardiac baroreflex responsiveness which may provide patients, astronauts, and high-performance aircraft pilots with protection from development of orthostatic hypotension.

NASA Discipline Cardiopulmonary↗

Selective norepinephrine reuptake inhibition as a human model of orthostatic intolerance

BACKGROUND: Observations in patients with functional mutations of the norepinephrine transporter (NET) gene suggest that impaired norepinephrine uptake may contribute to idiopathic orthostatic intolerance. METHODS AND RESULTS: We studied the effect of the selective NET blocker reboxetine and placebo in a randomized, double-blind, crossover fashion on cardiovascular responses to cold pressor testing, handgrip testing, and a graded head-up tilt test (HUT) in 18 healthy subjects. In a subset, we determined isoproterenol and phenylephrine sensitivities. Subjects ingested 8 mg reboxetine or placebo 12 hours and 1 hour before testing. In the supine position, heart rate was 65+/-2 bpm with placebo and 71+/-3 bpm with reboxetine. At 75 degrees HUT, heart rate was 84+/-3 and 119+/-4 bpm with placebo and with reboxetine (P<0.0001). Mean arterial pressure was 85+/-2 with placebo and 91+/-2 mm Hg with reboxetine while supine (P<0.01) and 88+/-2 mm Hg and 90+/-3 mm Hg at 75 degrees HUT. Blood pressure responses to cold pressor and handgrip testing were attenuated with reboxetine. Reboxetine increased the sensitivity to the chronotropic effect of isoproterenol and the pressor effect of phenylephrine. Vasovagal reactions occurred in 9 subjects on placebo and in 1 subject on reboxetine. CONCLUSIONS: Selective NET blockade creates a phenotype that resembles idiopathic orthostatic intolerance. This observation supports the hypothesis that disordered norepinephrine uptake mechanisms can contribute to human cardiovascular disease. Our study also suggests that NET inhibition might be useful in preventing vasovagal reactions.

Non-NASA Center↗

Inflight exercise affects stand test responses after space flight

PURPOSE: The purpose of this study was to determine whether exercise performed by Space Shuttle crew members during short-duration space flights (9-16 d) affects the heart rate (HR) and blood pressure (BP) responses to standing within 2-4 h of landing. METHODS: Thirty crew members performed self-selected inflight exercise and maintained exercise logs to monitor their exercise intensity and duration. Two subjects participated in this investigation during two different flights. A 10-min stand test, preceded by at least 6 min of quiet supine rest, was completed 10-15 d before launch (PRE) and within 4 h of landing (POST). Based upon their inflight exercise records, subjects were grouped as either high (HIex: > or = 3 times/week, HR > or = 70% HRmax, > or = 20 min/session, N = 11), medium (MEDex: > or = 3 times/week, HR < 70% HRmax, > or = 20 min/session, N = 10), or low (LOex: < or = 3 times/week, HR and duration variable, N = 11) exercisers. HR and BP responses to standing were compared between groups (ANOVA, P < or = 0.05). RESULTS: There were no PRE differences between the groups in supine or standing HR and BP. Although POST supine HR was similar to PRE, all groups had an increased standing HR compared with PRE. The increase in HR upon standing was significantly greater after flight in the LOex group (36 +/- 5 bpm) compared with HIex or MEDex groups (25 +/- 1 bpm; 22 +/- 2 bpm). Similarly, the decrease in pulse pressure (PP) from supine to standing was unchanged after space flight in the MEDex and HIex groups but was significantly greater in the LOex group (PRE: -9 +/- 3; POST: -19 +/- 4 mm Hg). CONCLUSIONS: Thus, moderate to high levels of inflight exercise attenuated HR and PP responses to standing after space flight.

manned↗

CoNNeCT Baseband Processor Module

A document describes the CoNNeCT Baseband Processor Module (BPM) based on an updated processor, memory technology, and field-programmable gate arrays (FPGAs). The BPM was developed from a requirement to provide sufficient computing power and memory storage to conduct experiments for a Software Defined Radio (SDR) to be implemented. The flight SDR uses the AT697 SPARC processor with on-chip data and instruction cache. The non-volatile memory has been increased from a 20-Mbit EEPROM (electrically erasable programmable read only memory) to a 4-Gbit Flash, managed by the RTAX2000 Housekeeper, allowing more programs and FPGA bit-files to be stored. The volatile memory has been increased from a 20-Mbit SRAM (static random access memory) to a 1.25-Gbit SDRAM (synchronous dynamic random access memory), providing additional memory space for more complex operating systems and programs to be executed on the SPARC. All memory is EDAC (error detection and correction) protected, while the SPARC processor implements fault protection via TMR (triple modular redundancy) architecture. Further capability over prior BPM designs includes the addition of a second FPGA to implement features beyond the resources of a single FPGA. Both FPGAs are implemented with Xilinx Virtex-II and are interconnected by a 96-bit bus to facilitate data exchange. Dedicated 1.25- Gbit SDRAMs are wired to each Xilinx FPGA to accommodate high rate data buffering for SDR applications as well as independent SpaceWire interfaces. The RTAX2000 manages scrub and configuration of each Xilinx.

Yamamoto, Clifford K↗