Search NASA⌕ Search

SEARCH · Search NASA

Results for “BRACHYTHERAPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of High-Dose-Rate and Low-Dose-Rate Brachytherapy Boost on Toxicity, Functional and Cancer Outcomes in Patients Receiving External Beam Radiation Therapy for Prostate Cancer: A National Population-Based Study

External beam radiation therapy (EBRT) with brachytherapy boost reduces cancer recurrence in patients with prostate cancer compared with EBRT monotherapy. However, randomized controlled trials or large-scale observational studies have not compared brachytherapy boost types directly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gantry-Based 5-Fraction Elective Nodal Irradiation in Unfavorable-Risk Prostate Cancer: Outcomes From 2 Prospective Studies Comparing SABR Boost With MR Dose-Painted HDR Brachytherapy Boost

Guidelines from the American Society of Clinical Oncology and Cancer Care Ontario recommend brachytherapy boost for patients with intermediate-risk or high-risk prostate cancer. SABR is an emerging technique for prostate cancer, but its use in high-risk disease is limited. Efficacy, toxic effects, and quality of life (QoL) were compared in patients treated on 2 prospective protocols that used SABR boost or magnetic resonance–guided high-dose-rate brachytherapy (HDR-BT) boost with 6 to 18 months of androgen deprivation therapy (ADT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Persistence of Late Substantial Patient-Reported Symptoms (LAPERS) After Radiochemotherapy Including Image Guided Adaptive Brachytherapy for Locally Advanced Cervical Cancer: A Report From the EMBRACE Study

This report describes the persistence of late substantial treatment-related patient-reported symptoms (LAPERS) in the multi-institutional EMBRACE study on magnetic resonance image guided adaptive brachytherapy in locally advanced cervical cancer (LACC).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biochemical Control and Toxicity Outcomes of Stereotactic Body Radiation Therapy Versus Low-Dose-Rate Brachytherapy in the Treatment of Low- and Intermediate-Risk Prostate Cancer

Low-dose-rate (LDR) brachytherapy and stereotactic body radiation therapy (SBRT) have both shown acceptable outcomes in the treatment of low- and intermediate-risk prostate cancer. Minimal data have been published directly comparing rates of biochemical control and toxicity with these 2 modalities. We hypothesize that LDR and SBRT will provide similar rates of biochemical control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative Electron Beam Radiation Therapy (IOERT) Versus High-Dose-Rate Intraoperative Brachytherapy (HDR-IORT) in Patients With an R1 Resection for Locally Advanced or Locally Recurrent Rectal Cancer

Intraoperative radiation therapy (IORT), delivered by intraoperative electron beam radiation therapy (IOERT) or high-dose-rate intraoperative brachytherapy (HDR-IORT), may reduce the local recurrence rate in patients with locally advanced and locally recurrent rectal cancer (LARC and LRRC, respectively). The aim of this study was to compare the oncological outcomes between both IORT modalities in patients with LARC or LRRC who underwent a microscopic irradical (R1) resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Long-Term Outcomes and Toxicity After Stereotactic Phosphorus-32–Based Intracavitary Brachytherapy in Patients With Cystic Craniopharyngioma

Interstitial brachytherapy based on phosphorus-32 (P-32) has an established role as a minimally invasive treatment modality for patients with cystic craniopharyngioma. However, reporting on long-term outcomes with toxicity profiles for large cohorts is lacking in the literature. The purpose of this study is therefore to evaluate the long-term visual, endocrinal, and neurocognitive functions in what is the largest patient series having received this treatment to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pr(H 3 BNMe 2 BH 3 ) 3 and Pr(thd) 3 as Volatile Carriers for Actinium-225. Deposition of Actinium-Doped Praseodymium Boride Thin Films for Potential Use in Brachytherapy

Here we show that the praseodymium N,N-dimethylaminodiboranate complex Pr(H 3 BNMe 2 BH 3 ) 3 and the 2,2,6,6-tetramethylheptane-3,5-dionate complex Pr(thd) 3 can serve as volatile carriers for 225 Ac. The actinium coordination complexes Ac(H 3 BNMe 2 BH 3 ) 3 and Ac(thd) 3 are the likely species subliming with the carrier material. A sample of 225 Ac-doped Pr(H 3 BNMe 2 BH 3 ) 3 was used to deposit amorphous 225 Ac-doped praseodymium boride films on glass and Si(100) at 300 °C. Furthermore, the α emission spectra of the refractory films are well-resolved, suggesting that they could be used as radioactive implants for brachytherapy and related treatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗