ECAR 4951 BSU-8242 3 DPA As-Run Physics Analysis

The purpose of this report is to document the as-run physics analysis for the Boise State University (BSU-8242) experiment in the A6, A7 and A8 positions, correlating with the 3 DPA specimens irradiated in Cycles 164A, 164B, and 166A. In this paper the heat rate, flux, fluence, and DPA for all specimens are scaled to the appropriate as-run lobe powers for an accurate assessment and description of the irradiated materials. Source terms per capsule are provided, and a bounded source term per specimen type is given on a per gram basis. Verified and validated MCNP full-core models were used for the neutronics analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

BSU-8242 As-Run Thermal Analysis

This report contains the Engineering Calculations and Analysis Report (ECAR)-5510 documenting the thermal as-run analysis of the 1 and 3 DPA capsules that comprised the BSU-8242 Nuclear Science User Facilities Experiment.

36 MATERIALS SCIENCE↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of As-read and As-run Dosimetry Data

The Nuclear Science Users Facilities (NSUF) is responsible for the coordination of experiments conducted in Advanced Test Reactor (ATR) by Universities and other outside organizations. Completion of the experiment and data reporting process is long and expensive. As such, it is expected that targets for temperature and neutron dosage are met. Simulations of expected reactor performance under specific conditions to meet these targets are critical for this process. However, it is not often that these reports are correlated with the data produced by monitors in ATR. This project aims to correlate simulation and read data from experiments in ATR to gauge uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗