Search NASA⌕ Search

SEARCH · Search NASA

Results for “BUFFER STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of a high-performance storage buffer with 3D XPoint devices for the DUNE data acquisition system

The DUNE detector is a neutrino physics experiment that is expected to take data starting from 2028. The data acquisition (DAQ) system of the experiment is designed to sustain several TB/s of incoming data which will be temporarily buffered while being processed by a software based data selection system. In DUNE, some rare physics processes (e.g. Supernovae Burst events) require storing the full complement of data produced over 1-2 minute window. These are recognised by the data selection system which fires a specific trigger decision. Upon reception of this decision data are moved from the temporary buffers to local, high performance, persistent storage devices. In this paper we characterize the performance of novel 3DXPoint SSD devices under different workloads suitable for high-performance storage applications. We then illustrate how such devices may be applied to the DUNE use-case: to store, upon a specific signal, 100 seconds of incoming data at 1.5 TB/s distributed among 150 identical units each operating at approximately 10GB/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-cost buffer storage for solar industrial steam applications

Motivation and importance: Many industrial process heat consumers operate throughout the day, and deep decarbonization with solar energy requires thermal energy storage. Thermal energy storage provides an additional operational benefit of firm delivery of steam – essential to reducing the risk of costly production interruptions. The group of process heat consumers that use steam for biofuels production for the California transportation fuels market is incentivized through the Low Carbon Fuel Standard (LCFS) to reduce their carbon intensity through the use of solar steam. Examples include ethanol and dimethyl ether production. The production of these and other fuels involves distillation driven by steam reboilers with steam pressures in the range 100-280 psig. These pressures can be delivered from the type of thermal energy storage that has been the focus of this project – a steam accumulator Sunvapor, Inc. (SVI) calls a “Bullet Steam Accumulator” or “BSA TM ”. Our project adds to the understanding of the design and integration of steam accumulators charged by solar thermal energy in a biofuels production facility, and similar facilities that consume process steam. The fuel application requires a demanding level of Process Safety Management not found in other steam applications. The type of steam accumulator SVI engineered and built integrates steam generation and storage in one vessel to reduce cost. Achieving a first of a kind permit to operate such a first device has also added to the understanding of the industrial application of such systems. Goals: The overall goal of the project has been to demonstrate the advantages that a “Bullet Steam Accumulator” (BSA™) can provide to solar steam integration with a manufacturing process. The industrial host has already been convinced of the potential of the available solar steam to lower than carbon intensity score. They have been interviewed for a number of publications such as that tout the advantages SVI’s system brings to their operations. Accomplishments: At the end of 2023 Sunvapor placed in service the country’s first industrial solar boiler with thermal energy storage. At the same time, this placement in service represents the first pilot commercial system to decarbonize biofuels production through the use of solar thermal energy. While the full technical effectiveness will be shown as soon as the customer’s plant is able to consume the available steam, the economic feasibility was indicated early in the project when the combination of costs and steam pricing required to meet investor expectations was determined. The project represents a reference pilot from which a full-scale commercial system may be expanded. This pilot is a necessary first step in providing the full potential benefits to the public, including decarbonization of transportation fuels. The decarbonization of the separation steps in fuels production may be the most cost-effective and nearest term solar fuel. Co-benefits include a reduction of air pollutants such as NOx and particulate matter, and job creation for the construction, operation and maintenance of industrial solar facilities.

14 SOLAR ENERGY↗

Parallel storage system with burst buffer appliance for storage of partitioned key-value store across a plurality of storage tiers

Parallel storage systems are provided with a burst buffer appliance for storage of a partitioned key-value store across a plurality of storage tiers. The burst buffer appliance is configured to store key-value data on first and second storage tiers comprising respective disjoint subsets of storage. One or more servers in the partitioned key-value store provide (i) an interface between one or more local key-value stores and one or more additional storage architectures, and/or (ii) a key value interface that provides access to at least one hardware key-value store. The local key-values are optionally sorted both locally by the local store and globally by the overall MDHIM framework. The local and global sorting can be leveraged to provide batch input/output (IO) operations that aggregate multiple requests into batch operations on one or more sorted ranges.

Bent, John M.↗

Multimodal CO2 Transportation Cost Model

This model provides a cost estimate for transporting CO2 via truck or rail in the United States using commercially available equipment and technologies. The model includes an analysis of direct and indirect CO2 emissions to determine costs per net tonne of CO2 transported. Publicly available data and methods published in the peer-reviewed literature are used to the extent possible; references are available at the bottom of the "Calculations" sheet. Upstream (i.e., liquefaction, buffer storage) and downstream (i.e., buffer storage, reconditioning) activities are included in the model of emissions and costs. All capital and operating expenditures are estimated in the "Calculations" sheet. The cost of financing the project is determined in the "FINEX" sheet. All user inputs are done via drop down menus in on the "User Interface" sheet. Summary results are also provided on the "User Interface" sheet.

Myers, CoreyA↗

Decontamination and Decommissioning Program of a Radiopharmaceuticals Production Facility - 17103

On May 2012, Best Medical Belgium (BMB) S.A., a manufacturer of pharmaceutical products located on the nuclear site of Fleurus, was declared bankrupt. According to the Belgian law, ONDRAF/NIRAS (Belgian Radioactive Waste Management Agency) was entrusted with the clean-up and the decommissioning operations of the former BMB facilities, nowadays known as 'ONDRAF/NIRAS Site Fleurus' (ONSF). In June 2015, ONSF launched a Decontamination and Decommissioning (D and D) program, for which Tractebel supports the definition of the clean-up and decommissioning strategies; the drafting of the Final Decommissioning Plan (FDP) and License Application for decommissioning; and the follow-up of the clean-up and upcoming D and D works on site. Four nuclear buildings are part of the clean-up and D and D activities. One of them, Building 14 (B14), represents the most challenging task with the clean-up of highly contaminated areas and their further decommissioning up to greenfield. Beside its two cyclotrons successively used for the production of radioisotopes, this building features hot cells and glove boxes used for the purification of radioisotopes and the conditioning of the final pharmaceutical product. The present paper aims at presenting the development of the D and D program in terms of modifications of existing facilities to allow carrying out the clean-up and D and D activities and the management of dismantled radioactive materials in a safe, efficient and cost-effective way as well as in terms of strategic options to be developed for the FDP. To support the clean-up and D and D activities, several workshops have been designed in order to treat radioactive materials removed from the building rooms. Those workshops feature an input buffer storage area, a common output buffer storage area and installations for the treatment of radioactive materials and waste (handling devices, cutting means, decontamination means, free release measurements means, etc.). Some modifications to the existing auxiliary systems will be required in order to dispose of appropriate systems to operate those workshops in a safe way. Activated concrete structures will constitute the most important part of radioactive materials that will arise from the decommissioning activities. To limit the total decommissioning costs, and especially the costs associated to radioactive waste management, two strategies have been developed in order to manage a part of activated concrete as candidate for free release with a certain decay period or as candidate for conventional landfill. Both strategies will have to be further detailed and discussed with the competent Authorities to ensure they can actually be implemented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Strategic Benefit of Self Shielded Boxes for Storage and Disposal of Metallic Uranic Material-18141

Sellafield Ltd, on behalf of the Nuclear Decommissioning Authority (NDA), is responsible for the management of a number of facilities whose inventories include a range of metallic uranic material. Additional fuel and fuel bearing materials exist in the NDA estate, some of which are similar to the Sellafield-managed inventory and others present different management challenges. Whilst UK Government policy directs that some of these materials are assets and are therefore managed with eventual future use in mind, there remains a large quantity of material, principally either out-of-scope for reprocessing or which derives from legacy facilities, which is likely to be disposed of to a future Geological Disposal Facility (GDF). The majority of this material is stored under wet conditions to facilitate dose shielding and heat dissipation and will therefore require removal from wet storage, consolidation and conditioning, prior to transfer to GDF. In order to accelerate high hazard and risk reduction by sooner retrieval of legacy material from wetted storage, one of the legacy storage facilities has led technical work to develop the design of Self Shielded Boxes (SSBs) and to substantiate their use for interim storage of the materials in question. Use of the SSBs would represent a change of strategy on the Sellafield Site: historically, timescales for retrieval of material have been reliant upon a waste treatment and storage/disposal route being available. SSBs provide the opportunity to retrieve uranic materials from aging legacy storage facilities for immediate buffer storage, by decoupling the timing of retrieval from the availability of an onward route. An understanding was required of the scope for defining optimal routes for each metallic uranic fuel and fuel bearing material group for safe transport and storage commensurate with current final disposal assumptions and risks, taking into account international best practice. A study is underway to understand options for transfer of material into SSBs, buffer/interim storage locations, treatment/conditioning processes and transport to the GDF. This work forms the basis of a prioritised road-map for the development of routes for study material groups aligned with ongoing and existing planned technical work, which is a pre-requisite to strategy development. The ultimate output of the study will be identification of full life cycle management strategies for metallic uranic material from an enterprise perspective. The combination of this strategic work and ongoing technical work will underpin a series of decisions to divert sub-groups of uranic material away from currently assumed baseline routes in support of earliest practicable hazard and risk reduction. Hence, each decision will reduce the scope of a placeholder future uranic fuel treatment capability, which will diminish the associated British Pound 1 bn capital cost. To date, a technical case for interim storage of uranic material in SSBs has been substantiated for around two thirds of the study materials. The requirement for a new strategy at Sellafield was driven by technical development of SSBs in response to the needs of one programme, but this prompted the study into the potential utilisation of SSBs in order to derive benefit for the wider enterprise and across the NDA estate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

User Guide for VISION 3.4.7 (Verifiable Fuel Cycle Simulation) Model

The purpose of this document is to provide a guide for using the current version of the Verifiable Fuel Cycle Simulation (VISION) model. This is a complex model with many parameters and options; the user is strongly encouraged to read this user guide before attempting to run the model. This model is an R&D work in progress and may contain errors and omissions. It is based upon numerous assumptions. This model is intended to assist in evaluating 'what if' scenarios and in comparing fuel, reactor, and fuel processing alternatives at a systems level. The model is not intended as a tool for process flow and design modeling of specific facilities nor for tracking individual units of fuel or other material through the system. The model is intended to examine the interactions among the components of a fuel system as a function of time varying system parameters; this model represents a dynamic rather than steady-state approximation of the nuclear fuel system. VISION models the nuclear cycle at the system level, not individual facilities, e.g., 'reactor types' not individual reactors and 'separation types' not individual separation plants. Natural uranium can be enriched, which produces enriched uranium, which goes into fuel fabrication, and depleted uranium (DU), which goes into storage. Fuel is transformed (transmuted) in reactors and then goes into a storage buffer. Used fuel can be pulled from storage into either separation or disposal. If sent to separations, fuel is transformed (partitioned) into fuel products, recovered uranium, and various categories of waste. Recycled material is stored until used by its assigned reactor type. VISION is comprised of several Microsoft Excel input files, a Powersim Studio core, and several Microsoft Excel output files. All must be co-located in the same folder on a PC to function. You must use Powersim Studio 8 or better. We have tested VISION with the Studio 8 Expert, Executive, and Education versions. The Expert and Education versions work with the number of reactor types of 3 or less. For more reactor types, the Executive version is currently required. The input files are Excel2003 format (xls). The output files are macro-enabled Excel2007 format (xlsm). VISION 3.4 was designed with more flexibility than previous versions, which were structured for only three reactor types - LWRs that can use only uranium oxide (UOX) fuel, LWRs that can use multiple fuel types (LWR MF), and fast reactors. One could not have, for example, two types of fast reactors concurrently. The new version allows 10 reactor types and any user-defined uranium-plutonium fuel is allowed. (Thorium-based fuels can be input but several features of the model would not work.) The user identifies (by year) the primary fuel to be used for each reactor type. The user can identify for each primary fuel a contingent fuel to use if the primary fuel is not available, e.g., a reactor designated as using mixed oxide fuel (MOX) would have UOX as the contingent fuel. Another example is that a fast reactor using recycled transuranic (TRU) material can be designated as either having or not having appropriately enriched uranium oxide as a contingent fuel. Because of the need to study evolution in recycling and separation strategies, the user can now select the recycling strategy and separation technology, by year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

VISION User Guide - VISION (Verifiable Fuel Cycle Simulation) Model

The purpose of this document is to provide a guide for using the current version of the Verifiable Fuel Cycle Simulation (VISION) model. This is a complex model with many parameters; the user is strongly encouraged to read this user guide before attempting to run the model. This model is an R&D work in progress and may contain errors and omissions. It is based upon numerous assumptions. This model is intended to assist in evaluating “what if” scenarios and in comparing fuel, reactor, and fuel processing alternatives at a systems level for U.S. nuclear power. The model is not intended as a tool for process flow and design modeling of specific facilities nor for tracking individual units of fuel or other material through the system. The model is intended to examine the interactions among the components of a fuel system as a function of time varying system parameters; this model represents a dynamic rather than steady-state approximation of the nuclear fuel system. VISION models the nuclear cycle at the system level, not individual facilities, e.g., “reactor types” not individual reactors and “separation types” not individual separation plants. Natural uranium can be enriched, which produces enriched uranium, which goes into fuel fabrication, and depleted uranium (DU), which goes into storage. Fuel is transformed (transmuted) in reactors and then goes into a storage buffer. Used fuel can be pulled from storage into either separation of disposal. If sent to separations, fuel is transformed (partitioned) into fuel products, recovered uranium, and various categories of waste. Recycled material is stored until used by its assigned reactor type. Note that recovered uranium is itself often partitioned: some RU flows with recycled transuranic elements, some flows with wastes, and the rest is designated RU. RU comes out of storage if needed to correct the U/TRU ratio in new recycled fuel. Neither RU nor DU are designated as wastes. VISION is comprised of several Microsoft Excel input files, a Powersim Studio core, and several Microsoft Excel output files. All must be co-located in the same folder on a PC to function. We use Microsoft Excel 2003 and have not tested VISION with Microsoft Excel 2007. The VISION team uses both Powersim Studio 2005 and 2009 and it should work with either.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ATLAS Data Carousel

The ATLAS experiment at CERN's LHC stores detector and simulation data in raw and derived data formats across more than 150 Grid sites world-wide, currently in total about 200PB on disk and 250PB on tape. Data have different access characteristics due to various computational workflows, and can be accessed from different media, such as remote I/O, disk cache on hard disk drives or SSDs. Also, larger data centers provide the majority of offline storage capability via tape systems. For the High-Luminosity LHC (HL-LHC), the estimated data storage requirements are several factors bigger than the present forecast of available resources, based on a flat budget assumption. On the computing side, ATLAS Distributed Computing was very successful in the last years with high performance and high throughput computing integration and in using opportunistic computing resources for the Monte Carlo simulation. On the other hand, equivalent opportunistic storage does not exist. ATLAS started the "Data Carousel" project to increase the usage of less expensive storage, i.e. tapes or even commercial storage, so it is not limited to tape technologies exclusively. Data Carousel orchestrates data processing between workload management, data management, and storage services with the bulk data resident on offline storage. The processing is executed by staging and promptly processing a sliding window of inputs onto faster buffer storage, such that only a small percentage of input data are available at any one time. With this project, we aim to demonstrate that this is the natural way to dramatically reduce our storage cost. The first phase of the project was started in the fall of 2018 and was related to I/O tests of the sites archiving systems. Phase II now requires a tight integration of the workload and data management systems. Additionally, the Data Carousel studies the feasibility to run multiple computing workflows from tape. The project is progressing very well and the results presented in this document will be used before the LHC Run 3.

97 MATHEMATICS AND COMPUTING↗

Techno-economic optimization of renewable urea production for sustainable agriculture and CO 2 utilization

Abstract Urea is the most used nitrogen fertilizer due to its ease of storage, transportation, and application. It is made by combining ammonia and carbon dioxide (CO 2 ), both of which are produced predominantly from fossil fuels at present. The recent momentum behind ammonia production using renewable-powered electrolysis offers an opportunity to both make urea in a more sustainable way and utilize CO 2 from external sources. In this work, we present a techno-economic optimization model to minimize the cost of making urea in this way. The model allows for time-varying chemical production in response to renewable variability by simultaneously optimizing production facility design and hourly operation. We performed a case study for Minnesota considering the use of byproduct CO 2 from bioethanol production. We found that the present-day levelized cost of renewable urea is between $268 mt −1 and $413 mt −1 at likely implementable production scales up to 250 000 mt yr −1 . This is within the range of historical conventional urea prices while offering at least 78% carbon intensity reduction. Projecting to 2030, there is a clear economic case for renewable urea production with levelized cost as low as $135 mt −1 due to technology improvement and electrolysis manufacturing expansion, facilitating a urea production scale increase to 525 000 mt yr −1 . Optimal facilities use wind energy, with hydrogen and ammonia production operating in a flexible, time-varying way to minimize battery and hydrogen storage capacities. Urea production operates near steady state due to the relatively low cost of intermediate ammonia buffer storage. A mix of imported methane and locally produced hydrogen are used to provide heat for steam consumed in the urea synthesis.

Chemistry↗

Geologic Modeling and Simulation Report for the Aquistore Project

The Plains CO 2 Reduction (PCOR) Partnership, through the Energy & Environmental Research Center (EERC), is collaborating with the Petroleum Technology Research Centre (PTRC) on site characterization; modeling and simulation; risk assessment; public outreach; and monitoring, verification, and accounting (MVA) activities for the Aquistore project. The Aquistore project is a carbon capture, utilization, and storage (CCUS) project situated near the town of Estevan, Saskatchewan, Canada, and the U.S.–Canada border. This project is managed by PTRC and will serve as buffer storage of carbon dioxide (CO 2 ) from the SaskPower Boundary Dam CCUS project, the world’s first commercial-scale postcombustion CCUS project from a coal-fired electric generating facility. To date, an injection well and an observation research well (~500 ft apart) have been drilled and completed at the Aquistore site, with injection anticipated to begin in 2014. Using a combination of site characterization data provided by PTRC and independently acquired information, the PCOR Partnership has constructed a static geologic model to assess the potential storage capacity of the Aquistore site and provide the foundation for dynamic simulation. The geologic model and the results of the predictive simulations will be used in the risk assessment process to help define an overall monitoring plan for the project and to assure stakeholders that the injected CO 2 will remain safely stored at the Aquistore site.

54 ENVIRONMENTAL SCIENCES↗

Two-tier tube-trailer operation method and system to reduce hydrogen refueling cost

A method and system are provided for operating refueling station tube-trailers and compressors to reduce hydrogen refueling cost. A hydrogen refueling station includes a two-tier fuel supply of pressure vessels on a refueling station tube-trailer, with a first tier and a second tier of pressure vessels including at least one or more pressure vessels connected together. A separate control unit is coupled to the first tier and the second tier of pressure vessels with each of the control units coupled to a compressor. The compressor is coupled to a high pressure buffer storage by a separate control unit. In operation, pressure is monitored in the each tier. Hydrogen is consolidated selectively between the first tier of pressure vessel banks, the second tier pressure vessels, and the high pressure buffer. Based upon monitored pressures, one of the first tier of pressure vessels, the second tier pressure vessel banks, and the high pressure buffer is used to refuel vehicles.

Reddi, Krishna↗

Comparative I/O workload characterization of two leadership class storage clusters. In: PDSW '15 Proceedings of the 10th Parallel Data Storage Workshop

The Oak Ridge Leadership Computing Facility (OLCF) is a leader in large-scale parallel file system development, design, deployment and continuous operation. For the last decade, the OLCF has designed and deployed two large center-wide parallel file systems. The first instantiation, Spider 1, served the Jaguar supercomputer and its predecessor, Spider 2, now serves the Titan supercomputer, among many other OLCF computational resources. The OLCF has been rigorously collecting file and storage system statistics from these Spider systems since their transition to production state. In this paper we present the collected I/O workload statistics from the Spider 2 system and compare it to the Spider 1 data. Our analysis show that the Spider 2 workload is more more write-heavy I/O compared to Spider 1 (75% vs. 60%, respectively). The data also show the OLCF storage policies such as periodic purges are effectively managing the capacity resource of Spider 2. Furthermore, due to improvements in tdm_multipath and ib_srp software, we are utilizing the Spider 2 system bandwidth and latency resources more effectively. The Spider 2 bandwidth usage statistics shows that our system is working within the design specifications. However, it is also evident that our scientific applications can be more effectively served by a burst buffer storage layer. All the data has been collected by monitoring tools developed for the Spider ecosystem. We believe the observed data set and insights will help us better design the next-generation Spider file and storage system. It will also be helpful to the larger community for building more effective large-scale file and storage systems.

Gunasekaran, Raghul↗

Tuning HDF5 subfiling performance on parallel file systems

Subfiling is a technique used on parallel file systems to reduce locking and contention issues when multiple compute nodes interact with the same storage target node. Subfiling provides a compromise between the single shared file approach that instigates the lock contention problems on parallel file systems and having one file per process, which results in generating a massive and unmanageable number of files. In this paper, we evaluate and tune the performance of recently implemented subfiling feature in HDF5. In specific, we explain the implementation strategy of subfiling feature in HDF5, provide examples of using the feature, and evaluate and tune parallel I/O performance of this feature with parallel file systems of the Cray XC40 system at NERSC (Cori) that include a burst buffer storage and a Lustre disk-based storage. We also evaluate I/O performance on the Cray XC30 system, Edison, at NERSC. Our results show performance benefits of 1.2X to 6X performance advantage with subfiling compared to writing a single shared HDF5 file. We present our exploration of configurations, such as the number of subfiles and the number of Lustre storage targets to storing files, as optimization parameters to obtain superior I/O performance. Based on this exploration, we discuss recommendations for achieving good I/O performance as well as limitations with using the subfiling feature.

97 MATHEMATICS AND COMPUTING↗

Reference Station Design for Heavy-Duty Vehicles

Five alternative design configurations for a heavy-duty hydrogen refueling truck stop are detailed in this work. Each of the station concepts provides fast, 5-minute, 50 kg fills of up to 4 vehicles simultaneously, with a station capacity of 4200 kg/day. Two on-site production stations using PEM electrolysis are considered: one with off-peak production of the daily capacity; and one with on-demand production of hydrogen during vehicle refueling. Three delivered liquid hydrogen station concepts are considered: one with the same, high-pressure cascade storage system for dispensing as the electrolysis supplied stations, with low-pressure vaporization of the liquid hydrogen and pressurization via a compressor; and two with on-demand pressurization: one by low-pressure vaporization and compressors; and one with a cryogenic pump and high-pressure vaporization. Design, economic, and operational considerations for each of the components needed in these station concepts is provided. Of all the station concepts, the delivered liquid station with a low-pressure vaporizer and a cascade dispensing system has the lowest capital costs and equipment footprint, but the second highest operating costs primarily due to high costs for liquid hydrogen delivery. The lowest operating cost station is that with on-site production via PEM electrolysis at off-peak hours with a cascade delivery system. The low-pressure buffer storage system and electrolyzers have a large footprint and considerable capital costs, but could result in a low total cost of ownership, depending on the design timeline. The liquid hydrogen station with a cryo-pump has moderate capital costs, the lowest operating costs of the three delivered hydrogen stations, and the same small equipment footprint as the delivered liquid, cascade dispensing system. As cryogenic pumping technology improves and the capital costs for these pumps decreases, this station concept will become even more favorable. Three-dimensional renderings of the five station concepts provide station designers with a starting point for the development of heavy-duty refueling stations.

08 HYDROGEN↗

CMS Data transfer operations after the first years of LHC collisions

CMS experiment utilizes distributed computing infrastructure and its performance heavily depends on the fast and smooth distribution of data between different CMS sites. Data must be transferred from the Tier-0 (CERN) to the Tier-1s for processing, storing and archiving, and time and good quality are vital to avoid overflowing CERN storage buffers. At the same time, processed data has to be distributed from Tier-1 sites to all Tier-2 sites for physics analysis while Monte Carlo simulations sent back to Tier-1 sites for further archival. At the core of all transferring machinery is PhEDEx (Physics Experiment Data Export) data transfer system. It is very important to ensure reliable operation of the system, and the operational tasks comprise monitoring and debugging all transfer issues. Based on transfer quality information Site Readiness tool is used to create plans for resources utilization in the future. We review the operational procedures created to enforce reliable data delivery to CMS distributed sites all over the world. Additionally, we need to keep data and meta-data consistent at all sites and both on disk and on tape. In this presentation, we describe the principles and actions taken to keep data consistent on sites storage systems and central CMS Data Replication Database (TMDB/DBS) while ensuring fast and reliable data samples delivery of hundreds of terabytes to the entire CMS physics community.

Kaselis, Rapolas↗