Search NASA⌕ Search

SEARCH · Search NASA

Results for “Balloon Radiation Exploration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose escalation may be an option in any future exploration of potential benefits of pelvic radiation therapy in high-risk prostate cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cosmic microwave background with Brans-Dicke gravity. II. Constraints with the WMAP and SDSS data

Using the covariant formalism developed in a companion paper [F.-Q. Wu, L. E. Qiang, X. Wang, and X. Chen, preceding Article, Phys. Rev. D 82, 083002 (2010)] (paper I), we derive observational constraints on the Brans-Dicke model in a flat Friedmann-Lemaitre-Robertson-Walker universe with a cosmological constant and cold dark matter. The CMB observations we use include the Wilkinson Microwave Anisotropy Probe 5 yr data, the Arcminute Cosmology Bolometer Array Receiver 2007 data, the Cosmic Background Imager polarization data, and the Balloon Observations of Millimetric Extragalactic Radiation and Geophysics 2003 flight data. For the large scale structure we use the matter power spectrum data measured with the luminous red galaxy survey of the Sloan Digital Sky Survey Data Release 4. We parametrize the Brans-Dicke parameter {omega} with a new parameter {zeta}=ln(1/{omega}+1), and use the Markov-Chain Monte Carlo method to explore the parameter space. We find that using CMB data alone, one could place some constraints on positive {zeta} or {omega}, but negative {zeta} or {omega} could not be constrained effectively. However, with additional large scale structure data, one could break the degeneracy at {zeta}<0. The 2{sigma} (95.5%) bound on {zeta} is -0.008 37<{zeta}<0.010 18 (corresponding to {omega}<-120.0 or {omega}>97.8). We also obtained constraints on G/G, the rate of change of G at present, as -1.75x10{sup -12} yr{sup -1}<G/G<1.05x10{sup -12} yr{sup -1}, and {delta}G/G, the total variation of G since the epoch of recombination, as -0.083<{delta}G/G<0.095 at the 2{sigma} confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NSA Site Science: Use of ARM Observations from Northern Alaska to Evaluate and Improve Prediction Capabilities

The Arctic is warming at a rate nearly double that of the rest of the planet, leading to profound changes in atmospheric, oceanic, and ice processes. The U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) user facility has played a significant role in Arctic research, operating observatories in Alaska's North Slope for over 25 years. These observatories provide a rich, and wide-reaching dataset that offers insight into atmospheric processes in northern Alaska. This report details the results of a nine-year research project (2015–2024) supported by the DOE Atmospheric Systems Research (ASR) program, that leverages data from ARM’s deployment of observing facilities at Utqiaġvik (known as the North Slope of Alaska, or NSA, site) and Oliktok Point, Alaska. The project was conducted in two phases: - Phase 1 (2015–2019): Focused on understanding key atmospheric processes at Oliktok Point, including cloud formation, high-latitude precipitation, aerosol-cloud interactions, and cloud properties. - Phase 2 (2019–2024): Extended the research to the broader North Slope region, using data from both Oliktok Point and Utqiaġvik. Topics explored included surface energy budgets, atmospheric stability, ice nucleation processes, and microphysics in Arctic clouds. The project resulted in numerous research products, including 50 peer-reviewed publications and dissertations, 169 presentations, and 10 data products. These products cover a variety of topics, including: - Cloud Macro- and Microphysical Properties: Arctic clouds play a crucial role in energy transfer, and accurate representation in models is critical. The study explored cloud transitions, ice crystal shapes, and dual-wavelength radar data to understand ice crystal habits and size distributions. - Aerosol Properties and Processes: The team examined aerosol sources in the Arctic, including industrial emissions and natural sources. Observations showed significant spatial gradients in aerosol concentrations due to human activities and wildfire smoke. The influence of aerosols on cloud formation and the surface energy budget was also assessed. - Aerosol-Cloud Interactions: Research revealed that aerosols might suppress cloud ice production, affecting cloud radiative forcing and precipitation. The impact of local industrial emissions on cloud properties was also investigated. - Contextualizing the North Slope of Alaska in the context of the broader Arctic: To understand broader trends, the project evaluated large-scale circulation patterns and the influence of weather systems on the Arctic. Studies indicated that large-scale processes play a significant role in temperature patterns and the timing of snowmelt. - Advancing ARM Observational and Modeling Capabilities: The project developed new radar data products and advanced measurement techniques, including clutter mitigation and drizzle detection. Uncrewed aerial systems (UAS) and tethered balloon systems (TBS) were deployed to gather detailed atmospheric data. Additionally, the project supported 10 early career scientists, providing training and mentorship to undergraduate interns, graduate students, postdoctoral researchers, and early career researchers. These efforts contributed to the advancement of ARM research capabilities and fostered a new generation of scientists skilled in Arctic atmospheric research. Ultimately, this ASR-supported project has provided valuable insights into Arctic atmospheric processes and their broader climate implications. Recommendations for future work include continuing support for long-term observing at Arctic locations to foster additional research, further exploration of aerosol-cloud interactions and the potential impacts of enhanced industrialization of the Arctic, and expanded use of uncrewed systems to gather data in this remote and harsh environment. Additionally, the data products developed by this work, and the data products developed through the ARM infrastructure, leave a treasure-trove of additional information that should be explored for many years to come to gain additional insight into physical processes in the Arctic atmosphere that drive the rapid changes occurring in at high latitudes and their global impact.

58 GEOSCIENCES↗

OBSERVATION OF DIFFUSE COSMIC AND ATMOSPHERIC GAMMA RAYS AT BALLOON ALTITUDES WITH AN ELECTRON-TRACKING COMPTON CAMERA

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronautical Science/Japan Aerospace Exploration Agency on 2006 September 1, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 deg. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm{sup -2} we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be 10 times better than that of other experiments at around 1 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview of the TCV tokamak program: Scientific progress and facility upgrades

The TCV tokamak is augmenting its unique historical capabilities (strong shaping, strong electron heating) with ion heating, additional electron heating compatible with high densities, and variable divertor geometry, in a multifaceted upgrade program designed to broaden its operational range without sacrificing its fundamental flexibility. The TCV program is rooted in a three-pronged approach aimed at ITER support, explorations towards DEMO, and fundamental research. A 1 MW, tangential neutral beam injector (NBI) was recently installed and promptly extended the TCV parameter range, with record ion temperatures and toroidal rotation velocities and measurable neutral-beam current drive. ITER-relevant scenario development has received particular attention, with strategies aimed at maximizing performance through optimized discharge trajectories to avoid MHD instabilities, such as peeling-ballooning and neoclassical tearing modes. Experiments on exhaust physics have focused particularly on detachment, a necessary step to a DEMO reactor, in a comprehensive set of conventional and advanced divertor concepts. The specific theoretical prediction of an enhanced radiation region between the two X-points in the low-field-side snowflake-minus configuration was experimentally confirmed. Fundamental investigations of the power decay length in the scrape-off layer (SOL) are progressing rapidly, again in widely varying configurations and in both D and He plasmas; in particular, the double decay length in L-mode limited plasmas was found to be replaced by a single length at high SOL resistivity. Experiments on disruption mitigation by massive gas injection and electron-cyclotron resonance heating (ECRH) have begun in earnest, in parallel with studies of runaway electron generation and control, in both stable and disruptive conditions; a quiescent runaway beam carrying the entire electrical current appears to develop in some cases. Developments in plasma control have benefited from progress in individual controller design and have evolved steadily towards controller integration, mostly within an environment supervised by a tokamak profile control simulator. TCV has demonstrated effective wall conditioning with ECRH in He in support of the preparations for JT-60SA operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the divergence-free component of the polarization field, the B-mode component, reveals the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial divergence-free component of the polarization field, the B-mode, could reveal the presence of gravitational waves in the early Universe. The detection of such a component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: LSPE-Strip, a radiometer-based telescope on the ground in Tenerife-Teide observatory, and LSPE-SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2022/23 for LSPE-SWIPE, with a flight duration up to 15 days, and in Summer 2022 with two years observations for LSPE-Strip. In this work, we describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact on the performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE will reach a sensitivity in tensor-to-scalar ratio of σr < 0.01, set an upper limit r < 0.015 at 95% confidence level, and improve constraints on other cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

Observational Possibility of the Early GRBs using a Gaseous Electron Tracking Compton Camera in sub-MeV and MeV regions

GRBs have been recently known as a unique probe to catch the highest z galaxies and stars. Here I propose the new trigger method to catch high-z GRBs with z>10 efficiently by imaging sub-MeV gamma rays from GRBs. We have developed the Electron Tracking Compton Camera (ETCC) with reconstructing tracks of the recoil electron in Compton process to explore the MeV gamma-ray astronomy. By measuring the track of a recoil electron, the direction of the incident gamma ray is determined for each photon, which enables us to reconstruct the direction of GRBs by detecting only several ten photons (>100 keV). Ability of the large ETCC (100 cm{sup 2} effective area) to detect GRBs with z{approx}20 is revealed, based on the results of the balloon experiment and laboratory imaging test using the small ETCC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Needlet Internal Linear Combination performance on B -mode data from sub-orbital experiments

The observation of primordial B modes in cosmic microwave background (CMB) polarisation data represents the main scientific goal of most of the future CMB experiments. This signal is predicted to be much lower than polarised Galactic emission (foregrounds) in any region of the sky, pointing to the need for effective component separation methods. Aims. Among all the techniques, the blind Needlet Internal Linear Combination (NILC) is of great relevance given our current limited knowledge of the B-mode foregrounds. In this work, we explore the possibility of employing NILC for the analysis of B modes reconstructed from partial-sky data, specifically addressing the complications that such an application yields such as E–B leakage, needlet filtering, and beam convolution. We consider two complementary simulated datasets of future experiments: the balloon-borne Short Wavelength Instrument for the Polarisation Explorer (SWIPE) of the Large Scale Polarisation Explorer, which targets the observation of both reionisation and recombination peaks of the primordial CMB B-mode angular power spectrum, and the ground-based Small Aperture Telescope of Simons Observatory, which, instead, is designed to observe only the recombination bump at ℓ ~ 80. We assessed the performance of the following two alternative techniques to correct for the CMB E–B leakage: the recycling technique and the Zhao-Baskaran method. We find that both techniques reduce the E–B leakage residuals at a negligible level given the sensitivity of the considered experiments, except for the recycling method in the SWIPE footprint at ℓ < 20. Thus, we implemented two extensions of the pipeline, the iterative B decomposition and the diffusive inpainting, which enabled us to recover the input CMB B-mode power for ℓ ≥ 5. For the considered experiments, we demonstrate that needlet filtering and beam convolution do not affect the CMB B-mode reconstruction. Finally, with an appropriate masking strategy, we find that NILC foregrounds subtraction allows one to achieve sensitivities on the tensor-to-scalar ratio in agreement with the targets of the considered CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

PRIMORDIAL GRAVITATIONAL WAVE DETECTABILITY WITH DEEP SMALL-SKY COSMIC MICROWAVE BACKGROUND EXPERIMENTS

We use the Bayesian estimation on direct T - Q - U cosmic microwave background (CMB) polarization maps to forecast errors on the tensor-to-scalar power ratio r, and hence on primordial gravitational waves, as a function of sky coverage f{sub sky}. This map-based likelihood filters the information in the pixel-pixel space into the optimal combinations needed for r detection for cut skies, providing enhanced information over a first-step linear separation into a combination of E, B, and mixed modes, and ignoring the latter. With current computational power and for typical resolutions appropriate for r detection, the large matrix inversions required are accurate and fast. Our simulations explore two classes of experiments, with differing bolometric detector numbers, sensitivities, and observational strategies. One is motivated by a long duration balloon experiment like Spider, with pixel noise {proportional_to}{radical}(f{sub sky}) for a specified observing period. This analysis also applies to ground-based array experiments. We find that, in the absence of systematic effects and foregrounds, an experiment with Spider-like noise concentrating on f{sub sky} {approx} 0.02-0.2 could place a 2{sigma}{sub r} Almost-Equal-To 0.014 boundary ({approx}95% confidence level), which rises to 0.02 with an l-dependent foreground residual left over from an assumed efficient component separation. We contrast this with a Planck-like fixed instrumental noise as f{sub sky} varies, which gives a Galaxy-masked (f{sub sky} = 0.75) 2{sigma}{sub r} Almost-Equal-To 0.015, rising to Almost-Equal-To 0.05 with the foreground residuals. Using as the figure of merit the (marginalized) one-dimensional Shannon entropy of r, taken relative to the first 2003 WMAP CMB-only constraint, gives -2.7 bits from the 2012 WMAP9+ACT+SPT+LSS data, and forecasts of -6 bits from Spider (+ Planck); this compares with up to -11 bits for CMBPol, COrE, and PIXIE post-Planck satellites and -13 bits for a perfectly noiseless cosmic variance limited experiment. We thus confirm the wisdom of the current strategy for r detection of deeply probed patches covering the f{sub sky} minimum-error trough with balloon and ground experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-97: Pretreatment Test and Post-Treatment Evaluation for Iso-NTCP Dose Guided Adapive Radiotherapy (DGART), Experience with Prostate Cancer Patients Treated with Rectal Balloons

Purpose: To explore the feasibility of pretreatment test for iso-NTCP DGART and to compare the pretreatment test results with post-treatment evaluations. Methods: NTCP here refers to late rectal wall toxicity only and is calculated with the ring rectal wall DVH. Simulation for one time iso- NTCP DGART starts after half of the total dose was done for 10 patients to investigate if TCP gains could be achieved. Six patients were treated using a 12-fraction 4.3Gy technique and four using 16-fraction 3.63Gy technique. For each of the 12-fraction cases a VMAT plan was generated in Pinnacle3™ using the daily CT obtained prior to the 6th fraction. A pretreatment simulation was performed using only the first 6 daily CTs. The idea is to add the 6 original plan delivered doses with 6 DGART plan delivered doses by deformable dose accumulation (DDA) on each of the first 6 CTs, resulting in 6 rectal wall doses (RWDs) and NTCPs. The 95% confidence interval (95%CI) for the 6 NTCPs were computed.The posttreatment evaluation was done by: a) copy the DGART plan to 6 CTs for fraction 7–12 and calculate the 6 actual DGART delivered fractional doses; b) sum the 6 actual DGART doses with the 6 original plan delivered doses by DDA on each of the 12 CTs resulting in 12 post-treatment RWDs and NTCPs; c) boxplot the 12 post-treatment NTCPs. Results: Target dose gain is 0.76–1.93 Gy. The 95%CI widths of the pretreatment tests NTCPs were 1.1–2.7%. For 5 patients, the planned NTCP fell within the 95%CI. For 4 patients, the planned NTCP was lower than the 95%CI lines. Post-treatment results show that for 7 patients, the upper quartile was within the 95%CI; for 2 patients, the upper quartile were higher than the 95%CI. Conclusion: The pretreatment test yields conservative prediction of the actual delivered NTCP.

60 APPLIED LIFE SCIENCES↗

A Constraint on Primordial B-modes from the First Flight of the Spider Balloon-borne Telescope

We present the first linear polarization measurements from the 2015 long-duration balloon flight of Spider, which is an experiment that is designed to map the polarization of the cosmic microwave background (CMB) on degree angular scales. The results from these measurements include maps and angular power spectra from observations of 4.8% of the sky at 95 and 150 GHz, along with the results of internal consistency tests on these data. While the polarized CMB anisotropy from primordial density perturbations is the dominant signal in this region of sky, Galactic dust emission is also detected with high significance. Galactic synchrotron emission is found to be negligible in the Spider bands. We employ two independent foreground-removal techniques to explore the sensitivity of the cosmological result to the assumptions made by each. The primary method uses a dust template derived from Planck data to subtract the Galactic dust signal. A second approach, which constitutes a joint analysis of Spider and Planck data in the harmonic domain, assumes a modified-blackbody model for the spectral energy distribution of the dust with no constraint on its spatial morphology. Using a likelihood that jointly samples the template amplitude and r parameter space, we derive 95% upper limits on the primordial tensor-to-scalar ratio from Feldman–Cousins and Bayesian constructions, finding r < 0.11 and r < 0.19, respectively. Roughly half the uncertainty in r derives from noise associated with the template subtraction. New data at 280 GHz from Spider's second flight will complement the Planck polarization maps, providing powerful measurements of the polarized Galactic dust emission.

79 ASTRONOMY AND ASTROPHYSICS↗